ENGI 8673 Subsea Pipeline Engineering

Lecture 14: Wall Thickness Design Example

Shawn Kenny, Ph.D., P.Eng. Assistant Professor Faculty of Engineering and Applied Science Memorial University of Newfoundland spkenny@engr.mun.ca

Lecture 14 Objective

to illustrate design example for calculating minimum wall thickness requirements for pressure containment and local buckling (system collapse)

2008 S. Kenny, Ph.D., P.Eng.

ENGI 8673 Subsea Pipeline Engineering Lecture 14

Example 14-01

Calculate the minimum wall thickness to meet (i) pressure containment and (ii) system collapse requirements using DNV OS-F101 (2007) for a subsea oil pipeline beyond the 500m platform excursion

2008 S. Kenny, Ph.D., P.Eng.

ENGI 8673 Subsea Pipeline Engineering Lecture 14

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

Example 14-01 Calculate the minimum wall thickness to meet pressure containment requirements using DNV OS-F101 (2007) for a subsea oil pipeline beyond the 500m platform excursion limit. DEFINED UNITS MPa := 10 Pa
6

kPa := 10 Pa

GPa := 10 Pa

C := K

kN := 10 N

PIPELINE SYSTEM PARAMETERS Nominal Outside Diameter Diameter Out-of-Roundness (Sec.7 G200 Table 7-17) Initial Selection Nominal Wall Thickness (Sec.5 C203 Table 5-3) Fabrication Process (Sec.7 B300 Table 7-1) [SMLS, HFW, SAW] Corrosion Allowance (Sec.6 D203) Elastic Modulus Specified Minimum Yield Stress (Sec.7 B300 Table 7-5) Speciifed Minimum Tensile Stress (Sec.7 B300 Table 7-5) Coefficient of Thermal Expansion Poisson's Ratio Pipeline Route Length Linepipe Density Concrete Coating Thickness Concrete Coating Density OPERATATIONAL PARAMETERS API Gravity Product Contents Density cont := 1000 kg m
3

Do := 406.4mm Do := 1.6mm tnom := 15.9mm FAB := "SMLS" tcorr := 5mm E := 205GPa SMYS := 450MPa SMTS := 535MPa T := 1.15 10 := 0.3 Lp := 10km tc := 0mm s := 7850kg m c := 3050kg m
3 5 1

API := 30

141.5 131.5 + API

cont = 876 m Pd := 15MPa SC := "M" h ref := 15m T := 75 C

kg

Design Pressure (Gauge) Safety Class (Sec.2 C200-C400) [L, M, H] Design Pressure Reference Level Temperature Differential Maximum Water Depth Seawater Density Hydrotest Fluid Density

h l := 1000m

w := 1025kg m t := 1025kg m

2/24/2008

Page 1 of 6

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

DNV OS-F101 PARTIAL FACTORS AND DESIGN PARAMETERS System Operations Incidental/Design Pressure Factor (Sec.3 B304) System Test Incidental/Design Pressure Factor (Sec.3 B304) Material Resistance Factor (Sec.5 C205 Table 5-4) Safety Class Resistance Factor (Sec.5 C206 Table 5-5) Material Strength Factor (Sec.5 C306 Table 5-6) Maximum Fabrication Factor (Sec.5 C307 Table 5-7) fab := 1.00 if FAB = "SMLS" 0.93 if FAB = "HFW" 0.85 if FAB = "SAW" Wall Thickness Fabrication Tolerance(SEC.7 G307 TABLE 7-18) tfab := 0.5mm if FAB = "SMLS" tnom 4mm 0.125 tnom if FAB = "SMLS" tnom > 4mm 0.125 tnom if FAB = "SMLS" tnom 10mm 0.100 tnom if FAB = "SMLS" tnom 25mm 3mm if FAB = "SMLS" tnom 30mm 0.4mm if FAB = "HFW" tnom 6mm 0.7mm if FAB = "HFW" tnom > 6mm 1.0mm if FAB = "HFW" tnom > 15mm 0.5mm if FAB = "SAW" tnom 6mm 0.7mm if FAB = "SAW" tnom > 6mm 1.0mm if FAB = "SAW" tnom > 10mm 1.0mm if FAB = "SAW" tnom > 20mm Material Derating (SEC.5 C300 FIGURE 2) SMYS := tfab = 1.988 mm fab = 1.00 inc_o := 1.10 inc_t := 1.00 m := 1.15 SC := 1.138 U := 0.96

( T 50 C) 30MPa if 50 C < T < 100C 50 C 30MPa + ( T 100 C) 40MPa otherwise 100 C ( T 50 C) 30MPa if 50 C < T < 100C 50 C 30MPa + ( T 100 C) 40MPa otherwise 100 C

SMYS = 15.00 MPa

SMTS :=

SMTS = 15.00 MPa

fy := ( SMYS SMYS ) U fu := ( SMTS SMTS) U

fy = 418 MPa fu = 499 MPa

2/24/2008

Page 2 of 6

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

ENGINEERING ANALYSIS PRESSURE CONTAINMENT (Sec.5 D200) Local Incidental Pressure During Operations (Sec.4 B202; Sec.5 D203) Pli := inc_o Pd + cont g ( h ref h l) Local Incidental Pressure System Test (Sec.4 B202; Sec.5 B203 & D203) Plt := inc_t Pd + t g ( h ref h l) if inc_t Pd + t g ( h ref h l) Pli 1.03 Pli if SC = "L" 1.05 Pli if SC = "M" 1.05 Pli if SC = "H" External Hydrostatic Pressure Pe := w g h l Characteristic Yield Resistance - Operations (Sec.5 D203) fcb_o := min fy , Pe = 10.05 MPa Plt = 26.48 MPa Pli = 25.22 MPa

1.15
fu

fcb_o = 417.60 MPa

Characteristic Yield Resistance - System Test (Sec.5 D203) fcb_t := min SMYS , SMTS 1.15

fcb_t = 450.00 MPa

Wall Thickness Requirement - Operations (Sec.5 D202 Eqn.5.7) t1_o := 1+ Do SC m ( Pli Pe) 2 2 3 fcb_o t1_o = 8.20 mm

Minimum Wall Thickness -Operations (Sec.5 C202 Table 5-2) tmin_o := t1_o + tfab + tcorr Wall Thickness Requirement - System Test (Sec.5 D202 Eqn.5.7) t1_t := 1+ Do SC m ( Plt Pe) 2 2 3 fcb_t t1_t = 8.24 mm tmin_o = 15.18 mm

Minimum Wall Thickness - System Test (Sec.5 C202 Table 5-2) tmin_t := t1_o + tfab Minimum Wall Thickness Requirement for Pressure Containment tmin := max( tmin_o , tmin_t) tmin = 15.18 mm tmin_t = 10.18 mm

2/24/2008

Page 3 of 6

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

Wall Thickness Check - Pressure Containment tmin_chk := "WT PRESSURE CONTAINMENT OK" if t nom > tmin "INCREASE WALL THICKNESS" otherwise tmin_chk = "WT PRESSURE CONTAINMENT OK" Design Wall Thickness Parameters (Sec.5 C202 Table 5-2) t1_po := tnom tfab t1_o := tnom tfab tcorr t2_po := tnom t2_o := tnom tcorr LOCAL BUCKLING (SYSTEM COLLAPSE) (Sec.5 D400) Elastic Collapse Pressure (Sec.5 D401) t1_po = 13.91 mm t1_o = 8.91 mm t2_po = 15.90 mm t2_o = 10.90 mm

t1_po 2E Do Pel :=
1
2

Pel = 18.08 MPa

Plastic Collapse Pressure (Sec.5 D401) Pp := SMYS fab 2 t1_po Do Pp = 30.81 MPa

Pipeline Ovality (Sec.5 D401) fo := max 0.005 ,

2 Do Do

fo = 0.0079

Plastic Collapse Pressure (Sec.5 D401) b pc := Pel cpc := Pp + Pp Pel fo b pc = 18.08 MPa
2

t1_po
Do

cpc = 1077 MPa

d pc := Pel Pp

d pc = 17159 MPa + cpc

u pc :=

1 3 1

bpc2
3

u pc = 395 MPa

2 b pc3 b pc cpc v pc := + d pc 3 2 27

v pc = 5115 MPa

2/24/2008

Page 4 of 6

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

pc := acos

v pc 180 u pc3 pc 60 + 180 3 180

pc = 130.579

y pc := 2 u pc cos b pc 3

y pc = 9.302 MPa

Pc := y pc

Pc = 15.33 MPa

Allowable External Pressure Check (Sec.5 D401) Pe_all := Pc m SC Pe_all = 11.71 MPa

Wall Thickness Check - Local Buckling System Collapse Pe_chk := "WT SYSTEM COLLAPSE OK" if Pe Pc m SC

"INCREASE WT SYSTEM COLLAPSE" otherwise Pe_chk = "WT SYSTEM COLLAPSE OK" PROPAGATION BUCKLING (Sec.5 D500) Propagation Pressure (Sec.5 D501)

t2_po Ppr := 35 fy fab Do

2.5

Ppr = 4.43 MPa

Check on Requirements for Buckle Arrestors PBA_Rqd_Chk := "NO BA REQUIRED" if Pe < "BA REQUIRED" otherwise PBA_Rqd_Chk = "BA REQUIRED" Estimate Nominal Wall Thickness Buckle Arrestor (Sec.5 D502) t2_po_BA := 26mm Calculate Buckle Arrestor Propagation Pressure (Sec.5 D501) t2_po_BA = 26.00 mm Ppr m SC

Ppr_BA := 35 fy fab

t2_po_BA Do

2.5

Ppr_BA = 15.13 MPa

2/24/2008

Page 5 of 6

EN 8673 Subsea Pipeline Engineering

Lecture 14

Winter 2008

35 fy fab PBA_WT_chk := "BA WT OK" if Pe <

t2_po_BA Do

2.5

1.1m SC

"INCREASE BA WT" otherwise PBA_WT_chk = "BA WT OK"

2/24/2008

Page 6 of 6

References

DNV (2007). Submarine Pipeline Systems. Offshore Standard, DNV OS-F101, October 2007, 240p.

2008 S. Kenny, Ph.D., P.Eng.