Code
F6 32 F6 43 F1 F2 F3 F4 F4 1-33 F4 34 F4 35 F4 40 F4 41 F4 44 F4 46 F4 47 F4 48 F4 49 F4 50 F4 51 F4 65 F4 66 F4 67 F5 F5 00 F5 01 F5 02 F5 03 F5 09 F5 10 F5 11 F5 13 F5 14 F5 20 F5 22 F5 24 F5 26 F5 27 F5 28

Description
Original density high peak of auto original density level. Range is -99 to +99. Paper buckle for lower paper cassette. Range is -50 to +50. Will light up display. "1", then "Print". Single sheet aging. "2", "Print". Continous aging. "3", "Print". Output mode. "4". Enter following digits, "Print". Stop all functions by "clear/stop". Not listed in service manual. Should be same as earlier models (6th edition). Fans: Ozone suction, dust collecting & on 7728/7735, developer unit fan. Reycling solenoid. Optics fan motor 2 (not 7718) Exhauset fan motor (not 7718), lift motor. Paper feed solenoid on 7718 Paper feed clutch on 7718. Exit solenoid on others. Lift motor 1 (not 7718) Paper feed clutch 1 (not 7718) Paper feed solenoid 1 (Not 7718) Lift motor 2 (not 7718) Paper feed clutch 2 (not 7718) Paper feed solenoid 2 (not 7718) 7728/7735 LCT feed solenoid. 7728/7735 LCT feed tray up. 7728/7735 LCT feed tray down. Programming. "5", "Print". Enter digits listed, "Print".Use number keys to enter correct digit for result you want. Turn power off then on to lock in. Country. 0 is Japan. 1 is North America. 2 is Europe. Frequency. 0 is 50 hertz. 1 is 60 hertz Auto reset. 0 is none. 1 is 30 sec. 2 is one min. 3 is two min. Standby. 0 is no standby. 1 is two min. 2 is four min. standby. Fuser lamp start. 0 is zero cross control. 1 is phase control. Optics fan timer. 0 is standard. 1 is timer based on exposure lamp. Copy reservation. 0 is non-detect. 1 is detect. Power saving 0 is none. 1 is thirty min., 2 is sixty min., 3 in ninety min., 4 is three hours. 5 is four hours. Power save or dehumidifier selection. 0 is power save. 1 is dehumidifier mode. ADF selction. 0 is no ADF. 1 is machine is aware of ADF when connected to the copier (7115 only) Paper feed console selection. 0 is no console. 1 is machine aware of console when connected (7115 only) Exposure lamp voltage for measuring constant light quantity. 0 is non-detect. 1 is on. Duplex unit. 0 is no duplex unit. 1 is duplex auto. Enabled when connected. ( not 7718) 0 means does not count up. 1 does count up. For jam on second side of duplex job, except on 7718. Compares copies fed to originals to find double feeding possibilities. 0 does not count up, 1 counts up. (not 7718)

F5 33 F5 34 F5 38 F5 40 F5 50 F5 51 F5 53 F5 59 F5 60 F5 63 F5 65 F5 70 F5 71 F5 80 F5 81 F5 83 F5 84 F5 88 F5 89 F6 F6 00 F6 01 F6 02 F6 03 F6 04 F6 05 F6 06 F6 07 F6 08 F6 09 F6 10 F6 11

ADF operation w/o original. 0 is no operation w/o original. 1 is operation w/o original in F2 mode. Drum compensation background. 0 is none. 1;exposure voltage increase .2 volts for every 1600 copies, up to 38 times. 2; volts increase .2 every 2000 copies, up to 30 times. 3; volts increase .2 every 2400 copies, up to 26 times. Duplex intial mode. 0 is no selection. 1 is 1 sided to 2 sided. 2 is 2 sided to 2 sided. 3 is book copy to 2 sided. (not 7718). Dbl. Count on total counter. 0 will be sgl. Count on all sizes. 1 will be dbl. Count on 11 x 17 and A3. 2 will be dbl. Count on 11 x 17, 8 1/2 x 14, A3 & B4. Auto Exposure. If 0, manual, will not turn on when power is on. 1, auto will turn on. 2, "document" mode will turn on. 2 in 1 mode. 0 is 100%, 1 is reduction. (not 7718) Auto shift in duplexing if set to 1. (not 7718) Operation with empty toner hopper. 0 cause machine not operate at all. 1 will allow opeation. Factory standard is 0. Auto. Cassette selection. Only for 7715, with optional feed console. If 0 no auto selection. If 1, and cassette in use is empty, machine will auto. Switch to new cass. If loaded with and set for same size paper. To clear U13. If set to 0, any key can be used. 1, Press "paper tray" and "10" key. 7715, press "paper tray" and "0" key. 7728/7735 ETP operation cycle. Number of copies in refresh mode. 0 is 500. 1 is 1,000. 2 is 1,500. 3 is 2000. PM cycle. If set to 0, no PM . 1 is 1000 copies, 2 is 2000 copies. 3 ia 4,000, 4 ia 16,000, 5 is 30,000. Factory setting is 5. 7728/7735 Duplex unit PM cycle. 0 is no indicator, 1 is on. Paper priority. Size paper to default to. 0 is 11 x 8 1/2. 1 is 8 1/2 x 11 R. 2 is 8 1/2 x 14. 3 is 1 x 17. 4 is 5 1/2 x 8 1/2. Size selection for European copiers. 0 is B4. 1 is 8 x 13. 2 is 8 1/2 x 13. Based on the first sheet. If 0, copied with the largest avail. Paper size. 1 is actual size of sheet. 2 is A3, 4 is B4. 5 is A4, 6 is A5. Paper feed console, only on 7115. Same as 83, above. Paper size setting by user for 7715. 0 is yes, 1 is no. Opics fan motor error detecting is off, if 1.Turned on if optional fan is installed. Off if its not. Adj. And programming. Press 6, in service mode, press two digits listed here, then print. Number keys to change value. "reset key" to change neg. values. Mag. Between 99.1% and 100.9% in .1% increments, using -9 to +9 Similar tio 00. Cannot really explain, without trying it on a machine. 100% focus. Range is -50 to +50. 100% ratio of image to paper. (+) is enlargement. (-) is reduction. Range is -20 to +20. Regi. Adj. in reduc. And enlarge.. Range is -20 to +20. Each incr. + .2MM. Note-if C02 in F8 mode is chgd. This auto. changes. Reg. adj. in normal mode (100%) Range is -30 to +20. This might change if F04 is chgd.. It will also chg. If C02 in F8 mode is adjusted. Trimming adj. (LED array) Range is -20 to +20. Lead edge void timing. (+) is more than (-) Will be affected by C05 and C06. Trail edge void timing in reduction. Range is -9 to +30. Trail edge void timing in enlargement. Range is -9 to +9. Blacking prevention film home position relative to erase position. Range is -99 to +99. Exposure. Stand. Is 62 volts for 120 volt machs. 224 for 220 volt machs. Each incr. is .2 or .4 volts. Range is -99 to +99.

F6 12 F6 13 F6 14 F6 15 F6 16 F6 17 F6 18 F6 19 F6 21 F6 26 F6 28 F6 31 F6 33 F6 34 F6 36 F6 41 F6 42 F6 44 F6 45 F6 46 F6 47 F6 48 F6 50 F6 52 F6 53 F6 54 F6 56 F6 57 F6 60 F6 61 F6 62 F6 99 F7 F7 00 F7 21 F7 22 F7 23 F7 26

Photo mode exposure.*.2 volts for 120 volt machs. 16.4 for 220-240. Adj. range is -9 to +9. Each incr. is .4 volts. Zoom exposure in reduction. Similar to 11 & 12. Range is -9 to +9. Zoom exposure in enlargement. Similar toi 13. Exposure voltage correction. Range is -99 to +99. Automatically set if F8-C03 is adjusted. Auto original density sensor is normally calibrated when mach. Is turned on. Adj. in a range of -99 to +99.Auto set to 0 if F8-03 is adjusted. Grid voltage in standard mode. Standard is -810 volts. Range is -44 to +16. Each incr. is -8.3 volts. (+) is darker. (-) is lighter. Grid voltage in photo mode. Same explanation as 17 above. Bias volltage. Standard is -250 volts. Range is -36 to +24. (+) is darker. (-) is lighter. Toner density sensor gain voltage. Factory standard is 6 volts and the service manual warns you not to touch it. Toner density sensor judgement voltage level. This adjusts the toner supply starting voltage and also comes with a warning not to touch it. Exposure adjustment. Enter value with number keys. Use "Reset" key for (-) values. Or possibly the dark and light keys are used. (+) for lighter,(-) for darker. Press "OK" key. Then press "Print" . Press "Clear/Stop" twice. Fuser temperature adj. Each incr. is .7 degrees, probabloy centigrade.(1) is lower, )+) is higher. Range is -15 to +15. Original density average. Range is -99 to +99. Original density (light/dark). Range is -99 to +99. ADF original registration. Range is -32 to +32. Bypass paper buckle. Range is -40 to + 50. Paper buckle for 2nd side in duplex. Range is -50 to + 50. Paper buckle for ystem console. Range is -50 to +50. Paper buckle for LCT for 7728/7735. Range is -50 to +50. Registration adjustment. Range is -50 to + 50. Lower cassette registration adjustment. Range is -50 to +50. Upper system console registration adjustment. Range is -50 to +50. 7728/7735 Registration adjustment. Range is -50 to +50. Reduction focus. Range is -9 to +9. Enlargement focus. Range is -9 to +9. Registration void with ADF. Range is 0-99. Trail edge void from cassette. Range is -20 to +40. Trail void from bypass. Range is -20 to +40. Fuser temperature for dehumidifying. Range is -9 to +9. Drum background compensation. Enter "0" when installing new drum . Range is -9 to 38. Toner density. If (+) do not touch. If (-) set to lighter. Range is -2 to (+) 1. Backup memory. Press "Print" twice to clear all F6 codes back to a setting of "0". Electronic counter. Enter mode and press "7'". Press "Print". Enter code you want to use. Press "Print" You will see the present count in the display. Enter first three digits of your new value. Press "Print". This will lock the new value in. Press "Clear/Stop" and "User Preset" to escape mode.. Specific department manager code number. Total count. PM count. This is the number of copies since last PM. When you enter (000000) the wrench will display and the PM count will be cleared. Developer count. Copies since last developer change. Fuser web count. This appears to be the copies remaining on the fuser web.

F7 33 F7 34 F7 35 F7 36 F7 37 F7 38 F7 39 F7 40 F7 41 F8 F8 00 F8 01 F8 02 F8 03 F8 06 F8 07 F8 08 F8 14

F9

Fmode

Number of originals that have been fed through the ADF. Number of copies that have been duplexed on the 7728/7735. Number of copies that have fed through the bypass. Copies made by lower drawer. Copies made by upper tray of system console. Copies made by middle tray of system console. Copies made by lower tray of system console. Copies made by LCT. Copies made by upper drawer of copies (if no duplex unit installed). Operation adjustment.. Enter serv. Mode. Enter "8'. Press Print. Enter code you want. Change the value with the num. keys. Press "Clear/Stop" and "User Preset" to escape. Move exposure unit to center to adjust aperture plate. Adjust original registration. Measure input for original registration. Exposure lamp voltage if auto original density sensor has been replaced. Each time you Press "Print", 30p machine trouble codes or jam codes will display. Clear codes stored in 06 by pressing "Print". Might have to press it twice. Toner density (developer calibration) Enter service mode. Press "8" to enter F8. Press "Print" Press "0". Press "9". Press "Print". Machine will cycle for 2 minutes. When it stops, record the reading. Dev. Cal,. Is complete. Black density sensor output gain. After "14", press "Print". Record reading in F6-65. Tele.# (7728/7735) You can set the mach. To display your ph. No. when it calls for serv. Enter service mode. Press "9". Press "Print". Enter your tele. No. Use the recall key for the hyphen (-). Use the "Photo/auto" key for a space. To move around on the display, use the light & dark keys. When finished, press "Print" to lock in. Press "Clear/Stop" & "User Preset' to escape. To enter mode, press 3 keys simutaneously. "User preset", "Ledger/A3", "3". To exit, press 2 keys simutan. "User preset", "Clear/stop". After entering service mode, enter digit to get desired mode.