Você está na página 1de 2

08I 09

This is how a ridge end sho uld always be: protecting, aesthetic and efficient.
Aesthetic appeal and durability define the ideal
Ridge connection ventilation tile together with FIRSTFIX: the inno-vative duo for a high-class ridge.

ridge end. A true CREATON roof relies entirely on ceramics. The fullceramic ridge ventilation system guarantees not only for a l asting roof with regard to functional and technical aspects, but for a continuous aesthetic appeal, as well. With their ceramic ending (spoiler), the ridge connection ventilation tiles of CREATON create a line that runs parallel between ridge tiles and tile surface. This combination of visual value advantage of your roof and of lasting value retention of your house offers a considerable benefit compared to other solutions: The wave through of the tile must no longer be compensated with plastic components or closed with mortar. Follow-up operations involving non-ceramic alternative materials are thus excluded. Safely and systematically anchored, without ridge lath. Besides the outstanding ventilation at the ridge, which allows for a dry sub-construction, the ridge connection ventilation tile reduces the surface that would be exposed in case of storms.

Roof cross-section* Ventilation via ventilation tile. Ridge tile cemented. Ventilation cross-section approx. 27.3 cm2/ventilation tile Ventilation tile

Ridge tile PD X

Smooth tile DOMINO

Eaves batten distance variable

Counter-battening

FIRSTFIX

Gutter

Eaves flashing Drip plate

We achieve this by using a continuous, ceramic ending (spoiler) at the transition from surface tiles to ridge tiles. In connection with the ridge fixation system FIRSTFIX, each ridge tile is secured by corrosion-resistant stainless steel wire in addition to a common clamping. It is possible to realize the conventional fixation with ridge lath and aluminium ridge clamp as well as the quick and efficient installation with FIRSTFIX. With its ridge fixation system FIRSTFIX, CREATON offers an installation solution the can be realized without any further ridge
X

High safety without ridge lath. The quick and simple ridge installation.

Roof cross-section* Ventilation via ridge connection ventilation tile. Ridge tile laid dry. Ventilation cross-section 230 cm2/m ridge. According to DIN 4108, sufficient up to 23 m rafter length.

Ridge tile PD Ridge connection ventilation tile X

sub-construction (ridge lath support, ridge lath).


Y

Smooth tile DOMINO

Ridge tile fixation with ridge lath: The table below will allow for the determination of the
30 30

individual correct distance of the uppermost lath resp. ridge lath. The X/Y measurement is always measured on the counter-battening. The table values result from ridge connection ventilation tile, counter-battening and supporting battening 30/50 resp. 40/60. Other battening cross-sections must be determined separately or can be provided by CREATON AG on request.

Eaves batten distance variable

Counter-battening

X =d  istance between laths and ridge intersection (in mm) Y = distance between ridge laths (in mm) DN = roof pitch DN X Y 15 95 85 20 90 80 25 85 70 30 85 60 35 85 50 40 85 40 45 85 30 50 85 25 55 85 15

Gutter

DN X Y

15 95 95

20 90 90

25 80 80

30 80 70

35 80 60

40 80 50

45 75 40

50 70 35

55 70 25 Eaves flashing Drip plate * Above illustrated technical drawing to be understood as a construction example.

Support battening 30/50, ridge tile type PD (requirement: 2.5 pcs/m)

Support battening 40/60, ridge tile type PD (requirement: 2.5 pcs/m)

10I 11

CREATON Technology for custom-tail ored roofing.


Technical data: Size: Covering width: min. on av. max. Covering length: min. on av. max. Tile requirement: min. on av. max. Tile weight: Small pack: 4 tiles approx. 257 x 437 mm approx. 223 mm approx. 224 mm approx. 225 mm approx. 343 mm approx. 348 mm approx. 354 mm approx. 12.4 tiles/m2 approx. 12.7 tiles/m2 approx. 13.1 tiles/m2 approx. 4.0 kg Pallet: 240 tiles

Extensive fluidic tests have confirmed the superior protection against the intrusion of rain of our model DOMINO. The sophisticated interlockings allow for the protection against the intrusion of rain in case of roof pitches of 20 by means of a trussing sheet (CREATON UNO), of 18 using a heat-sealed or bonded sub-coverage sheet (CREATON DUO), of 16 with a rainproof sub-roof (CREATON TRIO) necessary according to our conditions of warranty**. We would be pleased to advise you with regard to the execution of the sub-roof area. In case of lath distances in the minimum/maximum limit range, it is absolutely necessary to indicate the lath distances in your order! Minor colour and size deviations are possible due to the natural variations of the raw clay.

Wall connection (top) with ventilation tile at ridge start*

Pent roof execution*


In case of customized designs, CREATON will provide the covering length on request.
Until inner edge of interlocking nose approx.

Design of verge flashing with verge tile left


< ) 90

Design of verge flashing with verge tile right with verge board*

with verge board* Half-width tile Smooth tile DOMINO

Smooth tile DOMINO

Kinked tile*

Mansard tile*

Design of verge flashing left with verge sheet and double bulge*

Design of verge flashing right with verge sheet and surface tile*

Half-width tile

Smooth tile DOMINO

Smooth tile DOMINO

* Above illustrated technical drawing to be understood as a construction example. **  The above indications pertaining to the lower deviation of the roof inclination and the execution of the subroof resulting from it are based on the guidelines of the ZVDH in Germany (German Roofing Trade). Other guidelines or standards (such as NORMEN) might be applicable outside Germany. They must be observed in each individual case and can be inquired through your local expert.

* Above illustrated technical drawing to be understood as a construction example.

Você também pode gostar