ALAM FLORA SDN BHD (Company No. 367713-X) 22 JUNE 2012 ENVIRONMENTAL NOISE MONITORING REPORT 1.

0 OBJECTIVE The objective of this monitoring is 1.1 1.2 To measure noise exposure level from air compressor and welder generator at Jalan 6 Depot. To enforce the use of hearing protection devices for workers who are working near to or air compressor or engine driven with in order to prevent them from hearing loss. 2.0 BACKGROUND 2.1 As stated in Section 9, Factories and Machineries (Noise Exposure) Regulations, the noise monitoring should be carried out according to Department Occupational Safety and Health Requirement. 2.2 2.3 2.4 Therefore, noise monitoring has been conducted at Jalan 6 Depot on 21 June 2012. The monitoring has covered all possible noise source (Machines), and Area (Working Sections). Monitoring was conducted at two high noise level areas which are air compressor and welder generator. 3.0 LEGAL REQUIREMENT According to the Factories and Machinery (Noise Exposure) Regulations 1989, states that 3.1 No employee shall be exposed to noise level exceeding equivalent continuous sound level of 90 dB (A) or exceeding the limits specified in the First Schedule or exceeding the daily noise dose of unity. 3.2 Where an initial workers exposure monitoring shows the possibility of any workers exposure to noise level at or above the action level, the employer shall provide approved hearing protection devices to their exposed workers. 3.3 Warning signs shall be posted at defined work areas in which workers may be exposed at or above the limits. 3.4 The warning signs shall clearly indicate that the area is a high noise area and that hearing protection devices shall be worn. 3.5 Any person who contravenes any provision of these Regulations shall be guilty of an offence and shall, on conviction, be liable to a fine not exceeding one thousand ringgit.

4.0

Result 4.1 Air compressor noise level No. Decibel level at distance from noise source (dB) Time Duration (minutes) LAeqt LAFmin LAFmax Permissible Exposure Limits of Factories And Machinery (Noise Exposure)Reg. 1989 1. 2. 3. 4. 5. Noise source 1 meter 2 meter 3 meter 4 meter 11.49 11.51 11.54 11.56 11.58 2.00 2.00 2.00 2.00 2.00 91 82.9 75.9 89.0 83.2 81.1 78.8 73 74.1 74.7 95.7 86.4 85 105.9 97.7 90 dB 90 dB 90 dB 90 dB 90 dB

* Noise level exceed permissible exposure limit 4.2 Welder generator noise level No. Location Time Duration (minutes) LAeqt LAFmin LAFmax Permissible Exposure Limits of Factories And Machinery (Noise Exposure)Reg. 1989 1. 2. 3. 4. 5. Noise source 1 meter 2 meter 3 meter 4 meter 12.08 12.10 12.12 12.19 12.20 2.00 2.00 2.00 2.00 2.00 96.9 93.5 90.1 87.7 86.9 95.9 91.1 89.0 86.1 86.0 97.4 94.8 92.5 91.3 87.5 90 dB 90 dB 90 dB 90 dB 90 dB

* Noise level exceed permissible exposure limit 5.0 RECOMMENDATION Based on Factories and Machinery (Noise Exposure) Regulations 1989, Regulation 15, the employer shall reduce and maintain employee exposure to noise level below the limits by (a) Personal protective equipment (PPE)

Provide an approved hearing protection device (i.e., earplugs, earmuffs) to, and ensure its use by an employee exposed to noise level at or above the limits

Earplugs can reduce the noise by 15 to 30 dB. Below are the example of earplug with cord

(b) Place noise warning sign at noise source area (air compressor and engine driven generator noise).

(Noise warning sign)

(Ear plug)

Prepared by:

Approved by:

......................................... (Aisahatikah Mustafa) Practical Student

.................................... (Ramizu Abdul Rahim) (Manager Environment Health & Safety)

(Schedule 1)

Noise Level (dB (A)-slow) 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115

Duration of Exposure Permitted per day (hours-minute) 16-0 13-56 12-8 10-34 9-11 8-0 6-58 6-4 5-17 4-36 4-0 3-29 3-2 2-50 2-15 2-0 1-44 1-31 1-19 1-9 1-0 0-52 0-46 0-40 0-34 0-30 0-26 0-23 0-20 0-17 0-15

Source : Permissible Exposure Limits of Factories And Machinery (Noise Exposure) Regulations 1989