Escolar Documentos
Profissional Documentos
Cultura Documentos
Agenda
Microsteam Power System:
What is it? How it works Typical Applications
In the past
Previous barriers for the use of small Steam Turbine Generators: Marginal Payback Large Physical Size Complex Operation Steam Quality Maintenance Noise Vibration not anymore
What is it?
Microsteam Power System: Self contained power system Utilizes steam to generate electricity where a microsteam turbine is the key element Ideal solution for application which utilizes a Pressure Reducing Valve (PRV) for steam applications
2011 Carrier Corporation
Control Panel
Steam Discharge
Power Panel
Turbine
Generator
Requirements
Energy Source:
Steam Flow Range: 4,000 20,000 lbs/hr Pressures:
Inlet: 100 250 psig (300 psig available under special order) Temperature: up to 500F Outlet: > 0 psig
Output
Up to 275 kW 480 volt / 3 phase / 60 Hz 380 volt / 3 phase / 50 Hz System Efficiency = 70%
Sound
85 dBa at 3 ft from unit at height of 5 feet
Performance
High Efficiency Radial Outflow Turbine: 80% at Pressure Ratio 2.5:1 70% at Pressure Ratio 5:1 Typical output between 150 275 kW
10
Robustness
Solid titanium alloy rotor with rugged blades machined into the disc:
Very rugged compared to the usual steam turbine with sheet metal blades Forgiving design for impure steam
11
Easy installation
Small footprint due to vertical construction:
34(W) X 40(L) X 78(H) Unique Vertical Design:
Fits Through Standard Door
Easy Installation:
No special foundation No alignment required
12
Typical Applications
Commercial/Institutional: 275 kW Generation or more: (possibility for multiple unit installation)
Office Buildings
Universities
Hospitals
Hotel / Resort
Petrochemical
Utilities
Ship
13
Pre-evaluation form
2011 Carrier Corporation 14
16
Steam System
(125 psig) (400 degF) Absorption Chiller (or other summer load)
(30 psig)
Steam System
Absorption Chiller (or other summer load)
(30 psig)
Return on Investment*
Estimated Operating Cost Work Sheet
Annual Operation #hours Regular Hours 8000 Peak hours 0 Electric Demand (note1) Carbon Credits Maintenance Total
Extra Steam Flow Required Annual Operating Cost (lb/hr) 1045 1045
$91,960
$264,000
$91,960
$264,000
* This is a demonstration only. Real values and real achievable payback periods will depend on a specific evaluation of the application/site in question.
19
2011 Carrier Corporation
Note 1: Assuming the electric demand can be lowered by the full amount of kW being generated
"Steam Cost"
AK 1.17
OR 0.48
RI 1.18
NJ 0.93
NV 1.88
KS 2.23
AZ 1.67 HI 1.91
NM 2.43
OK 2.08
Below 0.50 lbs of CO2e per kWh generated 0.50 to 1.00 lbs of CO2e per kWh generated 1.00 to 1.50 lbs of CO2e per kWh generated 1.50 to 2.00 lbs of CO2e per kWh generated 2.00 to 2.50 lbs of CO2e per kWh generated
*based on the National Renewable Energy Laboratory report on Source Energy and Emission Factors for Energy Use in Buildings (dated June 2007).
20
In this example, it was used the CO2 generation for the state of Tennessee based on the National Renewable Energy Laboratory report on Source Energy and Emission Factors for Energy Use in Buildings (dated June 2007). The applicable state/country information must be customized for each case.
7,398 tons of CO2e savings in 5 years of operation (not released to the atmosphere)
*This is a demonstration only. Real values will depend on a specific evaluation of the application/site 21 in question
Innovation/Differentiation PureCycle
Developed for:
Geothermal Waste heat applications
Innovation/Differentiation PureCycle
Carrier - Confidential
23
Innovation/Differentiation
Microsteam + ORC (PureCycle)
Typical applications: Biomass Solar Plants Co-gen plants Industrial (excess steam)
PureCycle
Steam @ high pressure
Steam @ low pressure
Microsteam
Up to 255 kWe
Maximized usage of the steam enthalpy (energy) Maximized kW output (30 40% more kW) Unique solution / unique opportunity
24
25
26
Summary
Applicable for applications where steam is being pressure reduced Unique opportunity for wasted steam pressure energy Savings opportunity for small steam systems: municipal and industrial
27
28
Thank you!
29