Questionnaire to Design AKIMist "E" Humidification System

Please return by email to or fax to


Electric Power Supply:

pherman@ikeuchiusa.com
513-942-3064
Date: 2012.12.13

Requirements and Facilities


Location Company Address Phone Contact Purpose of Humidification mail

To Compressor To Dry Fog Controller To Water Treatment System Any specific control circuit voltage?

V & V & V & Specific

Hz Hz Hz (

1 Phase 1 Phase 1 Phase V)

3 Phases 3 Phases 3 Phases No preference

Product in Manufacturing Process in Concern About the Room Humidification is to be Installed: Measurement (Volume) mx or ft = F F ) & & ft3 % RH mx m= m3

Supply Water: Water Pressure Water Treatment Water Analysis Point of Water Source MPa or Equipment to supply purified water
Analysis report of untreated water

psi Available Available NA NA

ft x ft x (Attach the floor plan to consider the humidification system layout) Worst Conditions (Temp.& Humidity) C or Desired Conditions (Temp.& Humidity) Is it a cleanroom? Is it a explosion-proof room? Layout of your manufacturing site Yes Yes Drawing or Illustration C (*Class: or

As specified in the attachment Not indoor Water available but the point not determined yet. Pipe size ( ) inch

Compressed Air: % RH Air Pressure No Quality No Attached NA Compressor Dryer Air Filter Oil Filter Air Heater Oil free? Available Available Available ( ( ( Yes Available microns ) microns ) C or F ) No No No No No MPa or psi

About the Air-conditioner and Outside Air: Point of Air Source Supply Air Outside Air Induction Worst Outside Air Conditions m3/ hr at m3/ hr at C C C or or or F ft3/ min at ft3/ min at & % RH Position of plumbing Up in the ceiling Exposed in the room Not determined yet ( to be informed ) F F Consumption limited? Limted to maximum ( ) m3 /min No limit As specified in attachment Not indoor Compresor air available but the point not determined yet. Pipe size ( ) inch

Please mark positions of pillars on the manufacturing site, on a drawign or illustration. Do you have your own general purchasing specification? Your Standard Terms and Conditions Schedule: (MM/DD/YY) Quote required by Assessment completion by Purchase order issue by Delivery date Installation completion by Start-up : : : : : : / / / / / /
Issued by

Yes

No

/ / / / / /
Checked by Approved by

8110 Beckett Center Drive, West Chester, OH 45069 USA / Phone: 513-942-3060 Fax: 513-942-3064 www.ikeuchiusa.com

Humidity Quantification (Standard)


Air Conditions and Humidity Quantification
Outside Air Induction or ft3 / min Supply Air or ft3 / min or F degrees
Air Conditioner

m3 /hr

m3 /hr C degrees

% RH

Return Air

Exhaust Air

Present Conditions C degrees or F degrees Desired Conditions C degrees or F degrees % RH % RH % RH % RH

Temperature (C degrees)

Relative Humidity (%RH) Absolute Humidity (Kg/Kg')

Indoor Conditions Outside Air Conditions Class Standard


Supply Air (m3/hr)

0.0000 0.0000
Outside Air Induction (m3/hr) Required Humidity (kg/hr)

# of Nozzles

Humidity Quantification (Standard)


Air Conditions and Humidity Quantification
ft3 / min F degrees % RH

Outside Air Induction Supply Air ft3 / min

Air Conditioner

Inside of facility

Return Air

Exhaust Air

Present Conditions

F degrees Desired Conditions

% RH

F degrees

% RH

* Data is assumed