Vapor Pressure Calculation by Antoine Equation (Ethanol)

Page 1 of 2

Navigation

berspringen

DDBST GmbH

Navigation

berspringen

Saturated Vapor Pressure


Calculation by Antoine Equation

Component Temperature Unit Property Unit Temperatures

Ethanol C kPa 80
(optional)

Calculate
Search Dortmund Data Bank for Ethanol: Create Overview or Search for Pure Component Properties Need parameters for other components? Contact DDBST

Antoine Equation Parameters (P in mmHg, T in C) No. A B C Tmin [C] Tmax [C] -57 77 80 243 1 8.20417 1642.89 230.3 2 7.68117 1332.04 199.2

Note: mmHg are used here with constant conversion factor 760 mmHg=101.325 kPa=14.696 psi, conversion exactly valid only for 273.15 K

Calculation for Given Temperatures Temperature [C] Pressure(1) [kPa] Pressure (2) [kPa] 80 108.281 108.432

Calculation Over Validity Range

http://ddbonline.ddbst.com/AntoineCalculation/AntoineCalculationCGI.exe

9/22/2013

Vapor Pressure Calculation by Antoine Equation (Ethanol)


Temperature [C] Pressure(1) [kPa] Pressure(2) [kPa] -57 -45 -33 -21 -9 3 15 27 39 51 63 75 87 99 111 123 135 147 159 171 183 195 207 219 231 243
Direct link to this calculation page

Page 2 of 2

0.0070638 0.0290378 0.10051 0.301733 0.804006 1.93691 4.28155 8.78938 16.9231 30.8123 53.4165 88.6832 T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax T > Tmax

T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin T < Tmin 141.855 218.342 325.043 469.754 661.174 908.805 1222.84 1614.02 2093.54 2672.86 3363.58 4177.33 5125.61 6219.72

Important Note
The results of this calculation page do not describe the properties exactly. The parameters have been adjusted to a number of experimental data points which can be erroneous. A parameter regression minimizes the deviations between calculated and experimental data. This procedure can add a significant deviation between calculated and experimental data in addition to the experimental errors. The parameters are valid only inside the given temperature ranges.

Disclaimer
This calculation service, including the parameters, is provided "as is". Although DDBST has made efforts that the parameters and the calculations are correct and accurate, DDBST makes no warranties of any kind, either expressed, implied, or statutory, including but not limited to warranties of usability for a particular purpose, or non-infringement. DDBST including its employees does not warrant that the parameters or the calculation will be error-free. DDBST including its employees is not liable for any direct, indirect, special, incidental or consequential damages arising out of the use - or the inability to use - any material on this site.

http://ddbonline.ddbst.com/AntoineCalculation/AntoineCalculationCGI.exe