Você está na página 1de 58

Aerofoil Climafan Plate Mounted & Short Cased Axials 50 Hz

AEROFOIL CLIMAFAN CONTENTS


Page: Woods Worldwide 4-5

Quality Assurance

Specification

Test Methods

How To Specify

Guide To Fan Selection

10-11

Performance Data

12-53

Dimensions and Weights

54-55

Ancillaries

56

Useful Information

57-58

WOODS WORLDWIDE
Woods Air Movement are the acknowledged leaders in the specialised world of air movement technology. Over 90 year's experience in designing and manufacturing air moving equipment has kept Woods in the forefront of innovation, enabling the company to maintain their leadership in a sophisticated and competitive market. This experience enables Woods to engineer a product as right for the market as the AEROFOIL CLIMAFAN. A fan whose specification has been particularly defined by the needs of the Original Equipment Manufacturing Industry (OEM). Designed after extensive market research to meet every requirement for volume air flow whilst being quiet, light, efficient and competitively priced. AEROFOIL CLIMAFANS contain many features which ensure simple installation, optimum performance, maximum safety in operation and minimum maintenance.

By setting and achieving far-sighted objectives for the AEROFOIL CLIMAFAN, Woods of Colchester have produced a range of fans to satisfy the most exacting demands of OEM users world-wide. The AEROFOIL CLIMAFAN Series are supplied fully assembled, either plate mounted or short cased, and ready for installation in air movement applications.

Low installed noise levels allows the customer to achieve stringent environmental noise requirements with their equipment. Lightweight Construction and Low Levels of Vibration the combination of state of the art manufacturing techniques and the use of modern materials results in a product which can be readily installed on lightweight heat transfer structures, statically balanced to minimise vibration levels. A Unique Aerodynamic Blade Section based on the latest aerospace technology, the impeller optimises the air performance that can be achieved from a non-ducted installation, and is designed specifically for the intended application. High Efficiency Performance the adjustable pitch angle impeller allows the optimum aerodynamic performance to be achieved for a given motor output, therefore minimising running costs. 500 to 1000 mm Size Range Fans are available in sizes 500 mm to 1000 mm diameter and most are available for either single or three phase operation. Flexibility of Design The alternative mounting configurations allows the customer to match the product best suited to the individual application. Product Reliability and Safety All rotating aluminium components are inspected using our dedicated real time radiography suite to ensure acceptable quality of castings. Reliability of Catalogue Performance The fans are tested to the latest British and International standards, the Aerofoil Climafan is catalogued showing a Type A, non-ducted performance to match the customers installed configuration. All Fans Weatherproof IP55 All fans are weatherproof IP55, and have integral overheat protection as standard on most single phase motors. 2 Year Guarantee Aerofoil Climafans are guaranteed for a period of 2 years, when installed in accordance with Woods operating and maintenance instructions.

AEROFOIL CLIMAFAN
AIR MOVEMENT

QUALITY SYSTEMS

Woods Air Movement Limited certifies that the Aerofoil shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

Quality Systems
Woods Air Movement Limited is committed to Quality Assurance. Registration to BS EN ISO 9001.94, means that Woods design is quality assured as well as the manufacture. Our commitment to Quality Assurance doesn't stop with the hardware. The performance data comes from standard tests carried out in Woods own laboratory which is British Standard and AMCA accredited. Those fans which are AMCA licensed for aerodynamic performance are identified by the AMCA Seal on the appropriate characteristic curve(s). A Aerofoil can be bought with the confidence as with all Woods products, that it will achieve the published performance data and match the assured quality. All the Woods JM Aerofoils are fitted with IP55 motors as standard, and come with a 2 year ex works warranty.

AEROFOIL CLIMAFAN SPECIFICATION


Motors
Constructed from aluminium as standard with special "T" slot and pad mounted fixings. Suitable for horizontal through to vertical shaft operation. Supplied IP55, with removable drain plugs. Bearings lubricated with wide temperature range grease, relubricatable or sealed for life depending on size. Continuous operating range -40 C to +50 C, (for other operating temperatures please enquire). Insulation class F as standard. 2 speed operation by Delta/Star ( / ) reconnection available on most three phase motors. Integral pre-wired capacitor on most single phase fans. Ratings comply with BS5000 Part 99 and IEC 34-1.

Impellers
Aluminium hub and clamp-plate, with either three or six equally spaced, fully adjustable, moulded, black, ultra violet stabilised, glass coupled polypropylene aerofoil section blades. All rotating aluminium components are X-ray examined prior to machining to ensure quality. Balanced to BS6861 Part 1 1987 (ISO 1940-1986) Grade G6.3. Corrosion resistant and suitable for continuous outside use from -40C to +50C, (for other operating temperatures please enquire).

Electrical Supply
220-240 V 50 Hz single phase (1) 380-420 V 50 Hz three phase (3) (60 Hz variants and other voltages are available on request) Speed control can be provided by Woods of Colchester's range of electronic and auto-transformer type speed controllers. Speed control details are based on the adoption of the more usual and technically superior three-wire circuit. The single phase controller rating may be less than the full load current, as only the "U" phase voltage is varied. Many of the regulatable, three phase motors may be offered for 2 speed applications by Delta/Star ( / ) reconnection. Each performance chart states the impeller Pitch Angle where approximately 80% of the full speed can be obtained by this method. Other Pitch Angles may offer other than 80% of full speed when the motor is reconnected in Star ( ).
Y

Short Cased Fans Motor and Impeller side guards to comply with BS848 Pt 5., and draft ISO standard. Choice of auto-transformer or electronic speed controllers. 2 speed switch for Delta/Star ( / )reconnection. Silencers.

Finish
Plate Mounted Mounting plates, mounting arms and guards are all hot dipped galvanised after manufacture, (in accordance with BS729:1971). Motors, aluminium alloy self finish. Short Cased Fans Fan casings, mounting arms, mounting feet and guards are all hot dipped galvanised after manufacture, (in accordance with BS729:1971). Motors, aluminium self finish.

Ancillaries
Plate Mounted Motor and impeller side guards to comply with BS848 Pt 5, and draft ISO standard. Choice of auto-transformer or electronic speed controllers. 2 speed switch for Delta/Star ( / )reconnection.

AEROFOIL CLIMAFAN TEST METHODS


Testing
The air and sound performance data has been measured by the latest version of British and International Standards:BS848 Pt 1 1980, (ISO CD5801) methods of testing air performance. BS848 Pt 2 1985, method of noise testing. It is essential, when comparing fan performances, that the same installation category and test standards are used at all times.

Acoustic Data
The sound levels quoted are based on tests carried out under the Woods certified laboratory conditions. Using the spectrum corrections stated on each performance chart, an unweighted or "A" weighted sound power spectrum can be obtained for both the inlet and outlet side of the fan.

Anechoic Test Suite at the Colchester site.

Flow Rate Testing.

Speed Regulatable Versions


If a speed regulatable version is required, (or Delta/ Star ( / ) reconnect on 3 phase versions) the duty volume flow required should be multiplied by 1.05 prior to fan selection being made.
Y

Motor Ratings
The motor ratings, starting, full load currents and speeds refer to the maximum output of the motor. When the impeller does not require the full output, the power and current will be less than the maximum quoted.

Computer-automated fan test room.

Air Performance
The catalogue performances for plate mounted fans are certified in accordance with the BSI C.A.M.E scheme, type A installation ( Non-ducted).

AEROFOIL CLIMAFAN HOW TO SPECIFY


Specifying The Fan
Having chosen the fan most suitable for your individual application. Please specify as follows:1. The fan shall be manufactured by Woods of Colchester model type Aerofoil Climafan, plate mounted or short cased (S-type). Motors, squirrel cage type, insulated to class F, bearings lubricated with high temperature grease, keyed shaft. To comply with BS5000 Pt 99 and IEC 34-1. Weatherproof to IP55. (Overheat protection provided on most single phase motors). Impellers, aluminium hub and clamp-plate, with either three or six equally spaced, fully adjustable moulded, black, ultra violet stabilised, glasscoupled polypropylene aerofoil section blades. All rotating aluminium components to be X-ray examined prior to machining to ensure quality. Mounting plates, manufactured from mild steel with hot dipped galvanised finish. Mounting Arms, manufactured from mild steel with hot dipped galvanised finish. Guards, manufactured to BS848 Pt 5 1986 from mild steel, wtih hot dipped galvanised finish Performance shall be established in accordance with BS848 Pt 1 1980, type A ,method of testing air performance (equivalent to ISO DP5801 Pt 1), and BS848 Pt 2 1985 method of noise testing. All plate mounted air performance figures shall have been independently verified in accordance with the BSI C.A.M.E. Scheme.

Ordering The Fan


After identifying the best fan for your application please order as follows:-

1.

Fan type: Plate mounted (above or below plate), or Short Cased (S-type) Form A or Form B. (See pages 54 and 55). Fan Code: eg: 63AC /8 /6 /24 where: 63 denotes the Fan impeller diameter in centimetres. AC denotes "AEROFOIL CLIMAFAN" /8 denotes a nominal 8 pole speed. /6 denotes the number of blades. /20 denotes the Pitch Angle for the required duty. Quantity required. Duty required at standard air and temperature e.g. 1.4 m3/s @ 60 Pa. Motor. eg: CT9 Electrical Supply: 220-240 V / 50 Hz / 1 380-420 V / 50 Hz / 3

2.

2.

3.

3. 4.

4.

5. 6.

5.

6.

7.

Ancillary items required. Plate Mounted: Impeller and Motor Side Guards, Speed Controller (electronic or auto-transformer) or 2 speed switch type MDS3.10. Short Cased (S-type): Impeller and Motor Side Guards, Silencers with or without pod, Speed Controller (electronic or auto-transformer) or 2 speed switch type MDS3.10.

7.

AEROFOIL CLIMAFAN GUIDE TO FAN SELECTION


Procedure
1. Guide to Chart Numbers of Possible Selections The charts are arranged in order of fan diameter, starting at 500 mm, up to 1000 mm diameter, and in order of fan speed for each diameter, 6 and 3 bladed fan impeller. NOTE: The chart numbers lead to a variety of fan sizes, impeller configurations and speeds. The fan selected from the alternatives available will depend on the most critical factor for the particular application Volume Flow and Pressure required, Size, Power Consumption, Sound Level or First Cost. 2. Required Duty Establish the volume flow and static pressure required of an individual fan at Standard Air (1.2 kg/m3).

Selection Example
D. m3). Duty Point Required - @ Standard Air (1.2 kg/ 1.4 m3/s @ 60 Pa static pressure. 1. 2. 3. 4. Volume Flow = 1.4 m3/s Fan Static Pressure = 60 Pa Overall inlet Sound Power Level = 63 LWA Pitch Angle required to achieve Duty Point = 24 Corrections to overall Sound Power level for 24 Pitch Angle.

5.

Frequency Hz 63 125 250 500 1K 2K 4K 8K Sound Power Level Inlet 64 64 63 61 58 53 49 47 Lw (Un-weighted) Outlet 71 70 67 64 60 55 51 51 Lw

3. Selection on Individual Fan Charts The data provided on each performance chart is specifically for non-ducted - Type A (non-ducted) installations for both plate mounted or short cased (Stype) fans. Providing reasonable Type A conditions are maintained in installation of the fans, no additional factors to volume flow or pressure need be incorporated for a suitable selection to be made. Plot the duty on the selected fan charts to establish blade angle, sound level, absorbed power, motor size and rating, for the particular arrangement on the application.

6.

Absorbed Power @ Duty Point @ 24 Pitch Angle = 0.153 kW. Suitable Motor for fixed speed application, 3 phase supply = CT9 Motor Data: Motor Rating (kW) Full Load (A) Starting Current (A) = = = 0.3 1.4 2.6

7.

10

AEROFOIL CLIMAFAN Fan Code: 63AC/8/6/... 630 mm 680 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 100


8 Pa 84

2000 2000
rt 1

4000 6000 8000

6000 10000
BS848:Pt 1:80

4000

mm in wg 0.4 10

SA

V Type A Air Density 1.2 kg/m3

BS

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 63 -29 -3 -25 +1 -17 -1 -15 +1 Frequency Hz 125 250 500 -8 +1 -9 0 -4 -1 -5 -2 1K 2K 4K 8K -23 -22 -17 -16 -6 -9 -17 -6 -10 -18 -5 -9 -13 -5 -10 -14

CAME Plate Mounted Fans Only

80

M PL
63 65 65

8 0.3

2
psF - FAN STATIC PRESSURE (Pa)

60

6 0.2

E
pdF

64 40 63 65 20 63 65 64 65 2 0.1 63 65 4

[
5

LWA LW

Outlet Levels
Pitch Angle LWA 8 - 18 8 - 18 20 - 36 20 - 36 Lw LWA LW Frequency Hz 63 -21 +5 -18 +8 125 250 500 1K -10 -4 -2 -4 +6 -9 +7 +5 -5 +4 +1 -2 +1 -4 -3 -3 2K 4K -7 -14 -8 -15 -7 -11 -8 -12 8K -20 -19 -13 -12 pr - ABSORBED POWER (kW)

0.5

8 12 1.0

16 1.5

20

24 2.0

28 32 36 2.5

3.0

1
0.3 0.2

Extra performance only from plate mounted fans. 6 Three blade performance available. See chart number (Sample -1).

36 32 28

0.1 0 8 0 0.5 1.0 12 16 1.5 20

24

2.0

2.5

3.0

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 10 - 16 18 - 22 28 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 0.3 1.1 1.5 2.7 Starting Current (A) 1.9 2.5 3.5 Pitch Angle () 10 - 12 16 - 18 28 - 32 Motor Rating (kW) 0.09 0.13 0.25

qv - VOLUME FLOW (m3/s)

Chart No.SAMPLE
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1 1.7 ME1.3 1.3 2.3 2.1 3.4 ME1.3 ME1.6 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT9 CT5 Pitch Angle () 8 - 16 18 - 22 24 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 0.3 0.6 0.8 1.4
Y

1.1 1.5 2.6

10 - 12 14 - 18 26 - 32

0.09 0.13 0.25

0.7 1.2

1.5 2.6

ME3.2D ME3.2D

18 32

CT9

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55

11

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.5 0.9 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 50AC/6/3/... 500 mm 915 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 1000


Pa rt 1

1000 2000

2000 3000 4000

3000 5000

mm in wg 6000 7000 0.4 10 BS848:Pt 1:80


V Type A Air Density 1.2 kg/m3

4000

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Frequency Hz 2K 4K 8K -8 -13 -23 -9 -14 -22 -6 -9 -18 -7 -10 -17 Angle 63 125 250 500 1K 8 - 18 -28 -15 -8 -6 -6 8 - 18 -2 +1 +1 -3 -6 20 - 36 -25 20 - 36 +1 -15 +1 -9 0 -7 -4 -6 -6

CAME Plate Mounted Fans Only

80 70
psF - FAN STATIC PRESSURE (Pa)

BS

90

84

9 8 0.3 7

60 50 40 30 66 20 10 63

66

68

6 5 4 0.2

pdF 65 64 63 67

3 0.1 2 63 66 66 28 32 36 2 1 0 0

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 8 Frequency Hz 63 125 250 500 -13 +3 -13 +3 -7 +2 -8 +1 -5 -2 -6 -3 1K -4 -4 -4 -4 2K 4K 8K -6 -11 -20 -7 -12 -19 -3 -4 -6 -15 -7 -14 - 18 -25 - 18 +1

63 8 0 12

0 0.2
pr - ABSORBED POWER (kW)

16 20 24 1

20 - 36 -22 20 - 36 +4

36 0.1 24 28 32 20

8 0

12

16 1

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 14 - 30 32 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 1 1.5 Starting Current (A) 1.6 2.8 Pitch Angle () 18 - 24 32 - 34 36 Motor Rating (kW) 0.09 0.14 0.19

qv - VOLUME FLOW (m3/s)

Chart No. 1
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.1 0.8 1.6 ME1.1 1.2 1.8 2.8 3 ME1.3 ME1.3 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 Pitch Angle () 8 - 30 32 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.5 0.7 Y

1.2 1.8 -

20 - 24 26 - 34 -

0.09 0.14 -

0.6 -

1.8 -

ME3.2D -

34 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

12

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.4 1.2 ME3.2D 24

AEROFOIL CLIMAFAN Fan Code: 50AC/6/6/... 500 mm 915 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min m3/hr
120 1000
rt 1

1000

2000

3000

4000

2000

3000

4000

5000

6000

7000

mm in wg
12

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level:

100 90 80
psF - FAN STATIC PRESSURE (Pa)

CAME Plate Mounted Fans Only

BS

84

110

Pa

Air Density 1.2 kg/m3

10

0.4

67 70 67 60 50 40 30 20 10 68 8 0 0.2 0.4 0.6 65 68 67 68 67

69

0.3

pdF
69

6 0.2 4

Inlet Levels
Pitch Angle LWA LW LWA LW 63 125 Frequency Hz 250 500 1K 2K 4K 8K

8 8 20 20

18 18 36 36

-29 -3 -28 -2

-16 0 -17 -1

-6 +3 -7 +2

-5 -2 -6 -3

-6 -6 -6 -6

-9 -10 -7 -8

-16 -17 -12 -13

-25 -24 -21 -20

0.1 2 68 69 36 1.8

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 1K 2K 4K -27 -13 -5 -4 -4 -6 -13 -1 +3 +4 -1 -4 -7 -14 -26 -13 -6 -5 -4 -4 -9 0 +3 +3 -2 -4 -5 -10 8K -21 -20 -18 -17 pr - ABSORBED POWER (kW)

8 8 20 20

18 18 36 36

0 0.3

12 16 20 24 28 32 0.8 1.0 1.2 1.4 1.6

2.0

0.2 36 0.1 8 0.6 12 0.8 16 1.0 20 1.2 24 1.4 28 32

Three blade performance available. See chart number 1.

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 10 - 22 24 - 32 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 1 1.5 2.9

0.2

0.4

1.6

1.8

2.0

qv - VOLUME FLOW (m3/s)

Chart No. 2

Starting Current (A) 1.6 2.8 4

Pitch Angle () 12 - 18 24 - 26 28 - 32

Motor Rating (kW) 0.09 0.14 0.19

Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.1 0.8 1.6 ME1.1 1.2 1.8 2.8 3 ME1.3 ME1.3 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 22 24 - 32 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 0.5 0.7 1.3
Y

1.2 1.8 3.3

14 - 18 20 - 26 36

0.09 0.14 0.3

0.6 1.1

1.8 3.3

ME3.2D ME3.2D

26 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

13

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.4 1.2 ME3.2D 18

AEROFOIL CLIMAFAN Fan Code: 50AC/4/3/... 500 mm 1420 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m /hr 0 250


8
3

1000 2000
Pa rt 1

2000 4000

3000 6000

4000

5000 8000

6000 10000
BS848:Pt 1:80 V Type A

mm in wg 1.0 25 0.9 0.8 0.7

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -31 -20 -10 -5 -7 -5 -4 -1 -2 -7 -26 0 -17 -10 -1 -1 -7 -4 -7 -7 2K 4K -8 -11 -9 -12 -7 -8 -8 -9 8K -20 -19 -15 -14

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

200

20

psF - FAN STATIC PRESSURE (Pa)

150 78 75 100

80

15

0.6 0.5 0.4 0.3

pdF 10 76 75 79

79

80 50 76 8 0 0 1 12 78 78 28 32 36 2 3 0 0 5 0.2 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 8 20 20 18 18 36 36 Frequency Hz 63 125 250 500 -9 0 -9 0 -4 -1 -6 -3 1K -5 -5 -5 -5 2K 4K 8K -17 -16 -12 -11 -28 -18 -2 -2 -24 -16 +2 0 -6 -9 -7 -10 -5 -5 -6 -6

76

16 20 24

pr - ABSORBED POWER (kW)

0.6 36 0.4 28 0.2 0 8 0 1 12 16 20 24 32

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 16 - 20 22 - 38 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.23 0.39 0.7 1.6 2.7 4.4 Starting Current (A) 2.7 5.3 9.5 Pitch Angle () 16 - 18 20 - 22 32 - 34 Motor Rating (kW) 0.2 0.3 0.55

qv - VOLUME FLOW (m3/s)

Chart No. 3
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1.5 2.7 ME1.3 2.1 3.7 5.3 9.5 ME1.3 ME1.6 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 18 20 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.23 0.39 0.71 0.7 1.1 1.9
Y

2.4 4.6 6.5

12 - 16 18 - 24 30 - 36

0.2 0.3 0.58

0.9 1.7

4.6 6.5

ME3.2D ME3.2D

24 36

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

14

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.7 2.4 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 50AC/4/6/... 500 mm 1420 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 300


84 8

1000 2000
Pa rt 1

2000 4000

3000 6000

4000

5000 8000

6000 10000
BS848:Pt 1:80 V Type A

mm in wg 30 1.2 1.1 25 1.0 0.9

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Frequency Hz 2K 4K 8K -8 -12 -23 -9 -13 -22
-7 -9 -18 -8 -10 -17

250

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

200
psF - FAN STATIC PRESSURE (Pa)

20 80 80 15 80 80 79 82 81 10 pdF 81

0.8 0.7 0.6 0.5 0.4 0.3

150

100

Angle 63 125 250 500 1K 8 - 18 -34 -20 -11 -4 -6 8 - 18 -8 -4 -2 -1 -6


20 - 36 -32 20 - 36 -6 -18 -11 -2 -2 -5 -2 -6 -6

50 81 78 12 1.0 16 1.5 20 80 24 2.0 28 81

0.2 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 2K 4K 8K -6 -10 -20 -7 -11 -19
-5 -6 -7 -15 -8 -14

63 125 250 500 1K 8 - 18 -32 -16 -9 -3 -5 8 - 18 -6 0 0 0 -5


-14 +2 -8 +1 -5 -2 -5 -5

0 0 1
pr - ABSORBED POWER (kW)

8 0.5

32 2.5

36 3.0 0 0

20 - 36 -30 20 - 36 -4

0.8 0.6 0.4 0.2 0 8 0 0.5 1.0 12 16 1.5 20 24 28 32 36

Three blade performance available. See chart number 3

2.0

2.5

3.0

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 16 - 20 22 - 30 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.39 0.7 1.3 2.7 4.4 8.2 Starting Current (A) 5.3 9.5 23 Pitch Angle () 12 - 16 24 - 26 32 - 36 Motor Rating (kW) 0.3 0.55 0.9

qv - VOLUME FLOW (m3/s)

Chart No. 4
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.1 5.3 ME1.3 3.7 5.8 9.5 19 ME1.6 ME1.6 MT1.5 MT1.8

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 14 - 18 20 - 32 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.39 0.71 1.4 1.1 1.9 3.5
Y

4.6 6.2 14

12 - 16 22 - 26 28 - 36

0.3 0.58 0.9

1.7 2.3

6.5 9

ME3.2D ME3.2D

26 36

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

15

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.9 4.6 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 50AC/2/3/... 500 mm 2910 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m /hr 0 1000


8 Pa rt 1
3

5000 5000 10000 15000

10000 20000
BS848:Pt 1:80 V Type A

mm in wg 4.0 100

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 -41 -24 -16 -6 -15 -8 -7 -3 -39 -13 -19 -12 -3 -3 -5 -2 1K -4 -4 -5 -5 2K -7 -8 -7 -8 4K 8K -13 -19 -14 -18 -11 -14 -12 -13

BS

900 800 700 600 500

84

3.5 80 3.0

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

2.5 93 96 99 pdF 40 92 96 91 98 20 92 12 2 93 16 20 24 3 4 97 28 32 36 5 6 0.5 1.0 2.0 95 60

psF - FAN STATIC PRESSURE (Pa)

400 300 200 100

1.5

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 63 -39 -13 -37 -11 Frequency Hz 125 250 500 1K -19 -14 -3 -5 -14 -10 +2 -1 -4 -1 -3 0 -1 -1 -3 -3 2K -5 -6 -5 -6 4K 8K -10 -15 -11 -14 -9 -10 -10 -9

94 8 0 1

5
pr - ABSORBED POWER (kW)

4 3 2 1 0 8 0 1 2 12 16 3 20 24 28 32

36

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2225 F2229 Pitch Angle () 12 - 14 18 - 24 26 - 34 Fixed Speed Motor Full Rating Load (kW) (A) 1.4 2.7 4 8.3 14 21 Starting Current (A) 27 50 85 Pitch Angle () Motor Rating (kW) -

qv - VOLUME FLOW (m3/s)

Chart No. 5
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) -

380-420 V / 50 Hz / 3
Motor CT9 F2225 F2229 Pitch Angle () 10 - 16 18 - 32 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 1.7 3.8 6.2 3.5 7.1 11
Y

20 44 90

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

16

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle -

AEROFOIL CLIMAFAN Fan Code: 50AC/2/6/... 500 mm 2910 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min m /hr 1100


3

0 0

2000 5000
Pa rt 1

4000

6000 10000

8000 15000

10000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 4.5

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Frequency Hz 1K 2K 4K 8K -3 -6 -11 -17 -3 -7 -12 -16 -4 -4 -6 -11 -16 -7 -12 -15 Angle 63 125 250 500 8 - 18 -45 -29 -17 -9 8 - 18 -19 -13 -8 -6 20 - 36 -37 -28 20 - 36 -11 -12 -11 -2 -8 -5

BS

84 8

1000 900 800


psF - FAN STATIC PRESSURE (Pa)

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

100

4.0

3.5 80 95 98 96 3.0 98 2.5 60 pdF 99 96 97 98 40 1.5 2.0

700 600 500 400 300

1.0 200 97 100 96 12 2 16 20 3 97 24 4 98 28 32 5 6 20 0.5

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 8 Frequency Hz 63 125 250 500 -12 -3 -6 +3 -6 -3 -5 -2 1K -1 -1 -2 -2 2K -4 -5 -4 -5 4K 8K -8 -14 -9 -13 -8 -12 -9 -11
pr - ABSORBED POWER (kW)

- 18 -41 -29 - 18 -15 -13

0 0 6 5 4 3 2 1 0 0

8 1

20 - 36 -32 -28 20 - 36 -6 -12

32 24 28

Three blade performance available. See chart number 5.

8 1 2

12

16 3

20

Electrical Data
220-240 V / 50 Hz / 1
Motor F2225 F2229 Pitch Angle () 12 - 16 18 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 2.7 4 14 21 Starting Current (A) 50 85 Pitch Angle () Motor Rating (kW) -

qv - VOLUME FLOW (m3/s)

Chart No. 6
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) -

380-420 V / 50 Hz / 3
Motor CT9 F2225 F2229 Pitch Angle () 8 10 - 22 24 - 34 Fixed Speed Motor Full Rating Load (kW) (A) 1.7 3.8 6.2 3.5 7.1 11
Y

20 44 90

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

17

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle -

AEROFOIL CLIMAFAN Fan Code: 56AC/8/3/... 560 mm 670 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 60 1000


Pa rt 1

1000 2000

2000 3000 4000

3000 5000 6000

4000 7000 mm in wg 6

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K 8K -27 -15 -7 -5 -6 -9 -14 -22 -1 +1 -24 -15 +2 +1 +2 -9 0 -2 -6 -3 -6 -10 -6 -7 -6 -8 -15 -21 -11 -18 -12 -17

50

CAME Plate Mounted Fans Only

BS

84 8

Air Density 1.2 kg/m3

0.2

40 63
psF - FAN STATIC PRESSURE (Pa)

61 30 61 60 20 60 10 59 59 12 60 62 28 32 36 1.5 2 1 58 62 2 59 pdF

3 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 -5 +4 -7 +2 -3 0 -5 -2 1K -4 -4 -4 -4 2K -6 -7 -5 -6 4K 8K -23 -13 +3 +3 -20 -12 +6 +4 -11 -19 -12 -18 -8 -15 -9 -14
pr - ABSORBED POWER (kW)

8 0 .12 0 0.5

16 20 24 1.0

.08 32 .04 8 0 0.5 12 16 1.0


qv - VOLUME FLOW (m3/s)

36 28 20 24

1.5

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 20 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.7 0.11 0.8 1.1 Starting Current (A) 1.2 1.9 Pitch Angle () 20 - 26 28 - 34 36 Motor Rating (kW) 0.065 0.09 0.13

Chart No. 7
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.1 0.9 1.3 ME1.1 1 1.3 1.7 2.1 ME1.3 ME1.3 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.07 0.11 0.5 0.6 Y

0.8 1.1 -

22 - 28 30 - 34 36

0.065 0.09 0.13

0.5 0.7

0.9 1.5

ME3.2D ME3.2D

34 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

18

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.5 0.8 ME3.2S -

AEROFOIL CLIMAFAN Fan Code: 56AC/8/6/... 560 mm 670 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 80
Pa rt 1 8 84

1000 2000

2000 4000

3000 6000

4000 mm in wg 8 0.3

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K 8K -26 -14 -7 -5 -5 -10 -18 -24 0 +2 -24 -14 +2 +2 +2 -9 0 -2 -5 -2 -5 -11 -19 -23 -5 -8 -14 -20 -5 -9 -15 -19

70

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

60

psF - FAN STATIC PRESSURE (Pa)

50 60 60 40 60

62

0.2

4 pdF

30 60 61 20 61

62 0.1 2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 -5 +4 -6 +3 -3 0 -3 0 1K -3 -3 -3 -3 2K 4K 8K -21 -11 +5 +5 -19 -10 +7 +6 -7 -15 -20 -8 -16 -19 -6 -11 -17 -7 -12 -16

10 61 0 0.2
pr - ABSORBED POWER (kW)

59 12 0.8 16 1.0 20 1.2

61 24 1.4 28

61 32 36 1.8 2.0

8 0 0.2 0.4 0.6

1.6

0.1 24 1.4 28 32

36

Three blade performance available. See chart number 7.

8 0 0.2 0.4 0.6

16 12 0.8 1.0 1.2

20

1.6

1.8

2.0

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 20 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 1.1 1.5 Starting Current (A) 1.9 2.5 Pitch Angle () 20 - 24 26 - 32 34 - 36 Motor Rating (kW) 0.09 0.13 0.18

qv - VOLUME FLOW (m3/s)

Chart No. 8
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1 1.7 ME1.3 1.3 1.6 2.1 2.6 ME1.3 ME1.3 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 18 20 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.07 0.11 0.16 0.5 0.6 0.8
Y

0.8 1.1 1.5

14 - 18 20 - 24 26 - 32

0.065 0.09 0.13

0.5 0.7

0.9 1.5

ME3.2D ME3.2D

24 32

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

19

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.5 0.8 ME3.2S -

AEROFOIL CLIMAFAN Fan Code: 56AC/6/3/... 560 mm 915 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 120


8 Pa

1000 2000
rt 1

2000 4000

3000 6000

4000

5000 8000
BS848:Pt 1:80 V Type A

mm in wg 12

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K 8K -27 -16 -7 -5 -6 -9 -14 -22 -1 -25 +1 0 -15 +1 +2 -9 0 -2 -6 -3 -6 -10 -6 -7 -6 -8 -15 -21 -11 -18 -12 -17

100

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

10

0.4

80
psF - FAN STATIC PRESSURE (Pa)

8 0.3 71 68

60 69 40

66

pdF

6 0.2

67 65 68

70 4

0.1 20 66 66 8 0 0.3
pr - ABSORBED POWER (kW)

2 68 69 5

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 -23 +3 -20 +6 125 250 500 -13 +3 -12 +4 -5 +4 -7 +2 -4 -1 -5 -2 1K -4 -4 -4 -4 2K -7 -8 -5 -6 4K 8K -12 -19 -13 -18 -8 -14 -9 -13

12

16

20 24 28 32 36 1.5 2.0 2.5 0 0

0.5

1.0

0.2 32 0.1 8 12 1.0 16 1.5 20 28 24

36

0.5

2.0

2.5

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 10 - 22 24 - 30 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 1 1.5 2.9 Starting Current (A) 1.6 2.8 4 Pitch Angle () 12 - 16 22 - 24 Motor Rating (kW) 0.09 0.14 -

qv - VOLUME FLOW (m3/s)

Chart No. 9
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.1 0.8 1.6 ME1.1 1.2 2.8 ME1.3 MT1.5 -

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 22 24 - 30 32 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 0.5 0.7 1.3
Y

1.2 1.8 3.3

14 - 16 18 - 24 34 - 36

0.09 0.14 0.3

0.6 1.1

1.8 3.3

ME3.2D ME3.2D

24 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

20

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.4 1.2 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 56AC/6/6/... 560 mm 900 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 140


8

1000 2000
Pa rt 1

2000 4000

3000 6000

4000

5000 8000

6000 10000
BS848:Pt 1:80 V

mm in wg 14 0.5

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -31 -18 -8 -5 -5 -5 -2 +1 -2 -5 -29 -17 -8 -6 -5 -3 -1 +1 -3 -5 2K 4K 8K -8 -15 -23 -9 -16 -22 -7 -13 -20 -8 -14 -19

BS

84

120

Type A
CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

12

100 71
psF - FAN STATIC PRESSURE (Pa)

10

0.4

80 69 60

69 70 pdF 8 0.3

6 71 69 70 4 0.1 0.2

40

71

20 70 68 8 0 1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -28 -13 -5 -3 -3 -2 +3 +4 0 -3 -26 -11 0 +5 -5 +4 -3 0 -3 -3 2K 4K 8K -6 -12 -20 -7 -13 -19 -5 -10 -17 -6 -11 -16

70

71 28 32 36 2 3

0 0.5
pr - ABSORBED POWER (kW)

12 16 20 24

0.4 0.3 0.2 0.1 0 8 0 1 12 16 20 24 2


qv - VOLUME FLOW (m3/s)

36 28 32

Three blade performance available. See chart number 9.

Electrical Data
220-240 V / 50 Hz / 1
Motor BT5 BT9 CT5 Pitch Angle () 8 - 14 16 - 22 26 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 1 1.5 2.9 Starting Current (A) 1.6 2.8 4 14 28 - 30 Pitch Angle () Motor Rating (kW) 0.14 0.3

Chart No. 10
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 1.2 2.4 2.8 4 ME1.3 ME1.3 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT5 BT9 CT5 Pitch Angle () 8 - 12 14 - 20 22 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.12 0.19 0.37 0.5 0.7 1.3
Y

1.2 1.8 3.3

12 - 16 26 - 30

0.14 0.3

0.6 1.1

1.8 3.3

ME3.2D ME3.2D

16 30

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

21

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle -

AEROFOIL CLIMAFAN Fan Code: 56AC/4/3/... 560 mm 1420 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 250


8 Pa rt 1 84

2000 4000

4000 8000

6000 12000

8000 mm in wg 1.0 25 0.9 0.8 0.7 0.6 0.5

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 -30 -20 -10 -4 -4 -4 -1 -1 -27 -18 -1 -2 -9 0 -5 -2 1K -6 -6 -6 -6 2K -8 -9 -8 -9 4K 8K -12 -21 -13 -20 -10 -16 -11 -15

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

200

20 83 80

psF - FAN STATIC PRESSURE (Pa)

150 79 82 100 78 80 82 pdF

15

10

0.4 0.3

81 50 79 12 16 2 80 82 0.1 20 24 28 32 36 3 4 0 0 5 79 0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -25 -17 -8 -3 -4 +1 -1 +1 0 -4 -22 -15 -8 -4 -4 +4 +1 +1 -1 -4 2K -6 -7 -6 -7 4K -10 -11 -7 8K -18 -17 -13

8 0 1.0
pr - ABSORBED POWER (kW)

-8 -12

36 0.5 20 24 32 28 12 16 2
qv - VOLUME FLOW (m3/s)

8 0 1

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 16 - 18 22 - 30 Fixed Speed Motor Full Rating Load (kW) (A) 0.39 0.7 2.7 4.4 Starting Current (A) 5.3 9.5 Pitch Angle () 12 - 16 24 32 - 36 Motor Rating (kW) 0.3 0.55 0.9

Chart No. 11
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.1 5.3 ME1.3 3.7 5.8 9.5 19 ME1.6 ME1.6 MT1.5 MT1.8

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 14 - 18 20 - 30 32 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.39 0.71 1.4 1.1 1.9 3.5
Y

4.6 6.5 14

12 - 16 22 - 26 -

0.3 0.58 -

1.7 -

6.5 -

ME3.2D -

26 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

22

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.9 4.6 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 56AC/4/6/... 560 mm 1420 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 350 2000


Pa rt 1

2000 4000

4000 6000 8000

6000 10000 12000

8000 14000 mm in wg 1.4 35

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 63 8 - 18 -35 8 - 18 -9 20 - 36 -32 20 - 36 -6 Frequency Hz 125 250 500 1K -21 -13 -5 -5 -5 -4 -18 -11 -2 -2 -2 -6 -3 -5 -5 -5 2K -8 -9 -6 -7 4K 8K -12 -21 -13 -20 -10 -18 -11 -17

BS

84

300

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

30

1.2

250 83
psF - FAN STATIC PRESSURE (Pa)

25

1.0

200 83 150

82 83 pdF

20

0.8

15 83 82 82 10

0.6

100

83

0.4

50 83 80 12 16 2 20

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 -16 0 -13 +3 -9 0 -7 +2 -2 +1 -3 0 1K -3 -3 -3 -3 2K -6 -7 -5 -6 4K 8K -10 -18 -11 -17 -8 -16 -9 -15 8 - 18 -33 8 - 18 -7 20 - 36 -29 20 - 36 -3

83 24 3 28

84 32 36 4

0.2

0 0 2
pr - ABSORBED POWER (kW)

8 1

1 28

36 32

Three blade performance available. See chart number 11.

8 0 1

12 2

16

20

24 3

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 F2245 Pitch Angle () 14 - 20 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.7 1.3 4.4 8.2 Starting Current (A) 9.5 23 Pitch Angle () 16 28 - 30 36 Motor Rating (kW) 0.55 1.1 1.7

qv - VOLUME FLOW (m3/s)

Chart No. 12
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 3.7 9.5 ME1.6 7.2 10 23 33 ME1.10 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2245 Pitch Angle () 12 - 20 22 - 34 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.71 1.4 2.7 1.9 3.5 5.8
Y

6.5 14 30

14 - 16 26 - 30 32 - 36

0.58 1.15 1.6

3 3.7

11.4 24

ME3.2D -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

23

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 6.5 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 63AC/8/3/... 630 mm 670 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 80
Pa rt

1000 2000
1

2000 4000

3000 6000

4000

5000 8000
BS848:Pt 1:80 V Type A

mm in wg 8 0.3

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18
20 - 36 20 - 36

70

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

60

50
psF - FAN STATIC PRESSURE (Pa)

0.2 64 67 4 pdF 64 61 66 0.1 2

40 66 30

64

Frequency Hz 63 125 250 500 1K 2K 4K -27 -16 -7 -4 -6 -10 -15 -1 0 +2 -1 -6 -11 -16
-25 +1 -15 +1 -8 +1 -5 -2 -6 -9 -13 -6 -10 -14

8K -22 -21
-17 -16

20

63

Outlet Levels
Pitch Angle LWA Lw LWA LW
8 - 18 8 - 18 20 - 36 20 - 36

10 62 8 0 0.5 1.0 12

62 16 1.5

64 20 24

66 28 32 36 2.0 2.5

Frequency Hz 63
-20 +6 -18 +8

125 250 500


-13 +3 -11 +5 -5 +4 -5 +4 -2 +1 -3 0

1K
-4 -4 -4 -4

2K

4K

8K
-19 -18 -14 -13

-8 -13 -9 -14 -7 -11 -8 -12

0.16
pr - ABSORBED POWER (kW)

0.12 0.08 0.04 0 8 1.0 12 20 24 28

36 32

Extra performance only from plate mounted fans.

16 1.5
3

0.5

2.0

2.5

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 Pitch Angle () 20 - 28 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 1.1 1.5 Starting Current (A) 1.9 2.1 Pitch Angle () 20 - 24 26 - 30 Motor Rating (kW) 0.09 0.13 -

qv - VOLUME FLOW (m /s)

Chart No. 13
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1 1.7 ME1.3 1.3 2.1 ME1.3 MT1.5 -

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 8 - 28 30 - 34 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 0.3 0.6 0.8 1.4
Y

1.1 1.5 2.6

20 - 24 26 - 30 -

0.09 0.13 -

0.7 -

1.5 -

ME3.2D -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

24

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.5 0.9 ME3.2D 24

AEROFOIL CLIMAFAN Fan Code: 63AC/8/6/... 630 mm 680 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 100


8 Pa 84

2000 2000
rt 1

4000 6000 8000

6000 10000
BS848:Pt 1:80 V Type A

4000

mm in wg 0.4 10

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 63 -29 -3 -25 +1 -17 -1 -15 +1 Frequency Hz 125 250 500 -8 +1 -9 0 -4 -1 -5 -2 1K 2K 4K 8K -23 -22 -17 -16 -6 -9 -17 -6 -10 -18 -5 -9 -13 -5 -10 -14

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

80

8 0.3 63 65 6 0.2

psF - FAN STATIC PRESSURE (Pa)

60

65

pdF 64 40 63 65 20 63 65 64 65 2 63 65 4

0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 -21 +5 -18 +8 125 250 500 1K -10 -4 -2 -4 +6 -9 +7 +5 -5 +4 +1 -2 +1 -4 -3 -3 2K 4K -7 -14 -8 -15 -7 -11 -8 -12 8K -20 -19 -13 -12 pr - ABSORBED POWER (kW)

0.5

8 12 1.0

16 1.5

20

24 2.0

28 32 36 2.5

3.0

0.3 0.2 32 0.1 0 8 0 0.5 1.0 12 16 1.5 20 24 28 36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 13.

2.0

2.5

3.0

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 10 - 16 18 - 22 28 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 0.3 1.1 1.5 2.7 Starting Current (A) 1.9 2.5 3.5 Pitch Angle () 10 - 12 16 - 18 28 - 32 Motor Rating (kW) 0.09 0.13 0.25

qv - VOLUME FLOW (m3/s)

Chart No. 14
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1 1.7 ME1.3 1.3 2.3 2.1 3.4 ME1.3 ME1.6 MT1.5 MT1.5

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 8 - 16 18 - 22 24 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.11 0.16 0.3 0.6 0.8 1.4
Y

1.1 1.5 2.6

10 - 12 14 - 18 26 - 32

0.09 0.13 0.25

0.7 1.2

1.5 2.6

ME3.2D ME3.2D

18 32

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

25

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.5 0.9 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 63AC/6/3/... 630 mm 900 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 140


8 84

2000 2000
Pa rt 1

4000 6000 8000

6000 10000 12000


BS848:Pt 1:80 V Type A

4000

mm in wg

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K 8K -27 -16 -7 -4 -6 -10 -15 -22 -1 0 +2 -1 -6 -11 -16 -21 -25 +1 -15 +1 -8 +1 -5 -2 -6 -9 -13 -6 -10 -14 -17 -16

120

BS

0.5
kg/m3

CAME Plate Mounted Fans Only

Air Density 1.2

12

100

10 74 8

0.4

psF - FAN STATIC PRESSURE (Pa)

80 71 73 60

71

0.3 pdF 6 71 74 4 0.1 0.2

40

68 70

20 69 69 12 1.5 16 2.0

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 -20 +6 -18 +8 125 250 500 -13 +3 -11 +5 -5 +4 -5 +4 -2 +1 -3 0 1K -4 -4 -4 -4 2K 4K 8K -19 -18 -14 -13 pr - ABSORBED POWER (kW) -8 -13 -9 -14 -7 -11 -8 -12

71

73

0 0.4 0.3 0.2 0.1 0

8 0 0.5 1.0

20 24 28 32 36 2.5 3.0

3.5

36 32 28 16 2.0 20 24

Extra performance only from plate mounted fans.

8 0 0.5 1.0 1.5

12

2.5

3.0

3.5

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 Pitch Angle () 16 - 20 26 - 34 Fixed Speed Motor Full Rating Load (kW) (A) 0.19 0.37 1.5 2.9 Starting Current (A) 2.8 4 Pitch Angle () 10 - 12 28 - 30 Motor Rating (kW) 0.14 0.3 -

qv - VOLUME FLOW (m3/s)

Chart No. 15
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1.2 2.8 ME1.3 2.4 4 ME1.3 MT1.5 -

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 8 - 20 22 - 34 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.19 0.37 0.68 0.7 1.3 2.2
Y

1.8 3.3 7.5

12 - 16 26 - 30 -

0.14 0.3 -

1.1 -

3.3 -

ME3.2D -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

26

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.6 1.8 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 63AC/6/6/... 630 mm 900 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 200


8 Pa rt 1

2000 4000

4000 8000

6000 12000

8000 mm in wg 0.8 20

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K -34 -21 -11 -5 -5 -9 -14 -8 -5 -2 -2 -5 -10 -15 -29 -17 -3 -1 -10 -1 -5 -2 -5 -5 -8 -13 -9 -14 8K -22 -21 -18 -17

CAME Plate Mounted Fans Only

BS

180 160

84

Air Density 1.2 kg/m3

15 140 120 100 80 60 74 40 20 72 12 16 2 20 73 24 74 28 32 36 3 4 74 pdF 74 72 71 5 74

0.6

psF - FAN STATIC PRESSURE (Pa)

72

74 10 0.4

0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 8 20 20 18 18 36 36 Frequency Hz 63 125 250 500 -5 +4 -3 +6 -2 +1 -2 +1 1K -3 -3 -3 -3 2K -7 -8 -6 -7 4K -12 -13 -11 -12 8K -19 -18 -15 -14 -30 -13 -4 +3 -25 -10 +1 +6

74 8 0 1

0 0.8
pr - ABSORBED POWER (kW)

0.6 0.4 0.2 0 8 0 1 12 16 2 24 28 36 32 20

Extra performance only from plate mounted fans. Three blade performance available. See chart number 15.

Electrical Data
220-240 V / 50 Hz / 1
Motor BT9 CT5 CT9 Pitch Angle () 8 - 10 16 - 22 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.19 0.37 0.68 1.5 2.9 5.2 Starting Current (A) 2.8 4 6.5 30 Pitch Angle () 16 - 18 Motor Rating (kW) 0.3 0.52

qv - VOLUME FLOW (m3/s)

Chart No. 16
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 2.4 4 4 9.2 ME1.3 ME1.6 MT1.5 MT1.8

380-420 V / 50 Hz / 3
Motor BT9 CT5 CT9 Pitch Angle () 8 10 - 22 24 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.19 0.37 0.68 0.7 1.3 2.2
Y

1.8 3.3 7.5

14 - 18 26 - 30

0.3 0.52

1.1 1.7

3.3 7.5

ME3.2D ME3.2D

18 30

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

27

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle -

AEROFOIL CLIMAFAN Fan Code: 63AC/4/3/... 630 mm 1420 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 350


84 8

2000 5000
Pa rt 1

4000

6000 10000

8000 15000

10000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 1.4

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 -30 -21 -12 -4 -4 -5 -3 -1 -27 -1 -18 -2 -10 -1 -5 -2 1K 2K 4K -5 -9 -13 -5 -10 -14 -5 -5 -8 -12 -9 -13 8K -21 -20 -18 -17

300

BS

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

30

1.2

250

1.0

psF - FAN STATIC PRESSURE (Pa)

200 85 150 87

84

86 20 pdF 0.6 84 86 10 0.4 0.8

100

81 83

50 82 82 16 3

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 -23 +3 -20 +6 125 250 500 -18 -9 -2 -2 -15 +1 0 -7 +2 +1 -2 +1 1K -3 -3 -3 -3 2K 4K -7 -11 -8 -12 -6 -10 -7 -11 8K -19 -18 -16 -15
pr - ABSORBED POWER (kW)

84 20 24 4

86 28 32 36 5 6

0.2

0 0 1.6 1.2 1

8 12 2

36 32 28 16 3 20 24

Extra performance only from plate mounted fans.

0.8 0.4 0 8 0 1 2 12

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 F2245 Pitch Angle () 14 - 20 26 - 32 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.7 1.3 2 4.4 8.2 11 Starting Current (A) 9.5 23 35 Pitch Angle () 16 28 36 Motor Rating (kW) 0.55 1.1 1.7

qv - VOLUME FLOW (m3/s)

Chart No. 17
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 3.7 9.5 ME1.6 7.2 10 23 33 ME1.10 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2245 Pitch Angle () 12 - 20 22 - 34 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.71 1.4 2.7 1.9 3.5 5.8
Y

6.5 14 30

12 - 16 26 - 30 -

0.58 1.15 -

3 -

11.4 -

ME3.2D -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

28

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 6.5 ME3.2D 16

AEROFOIL CLIMAFAN Fan Code: 63AC/4/6/... 630 mm 1420 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 500


8

2000 4000
Pa rt 1

4000 8000

6000 12000

8000

10000 16000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 2.0 50

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Frequency Hz 2K -7 -8 -6 -7 4K 8K -11 -20 -12 -19 -11 -18 -12 -17 Angle 63 125 250 500 1K 8 - 18 -37 -23 -15 -6 -4 8 - 18 -11 -7 -6 -3 -4 20 - 36 -32 20 - 36 -6 -18 -2 -12 -3 -6 -3 -4 -4

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

400

40

1.6

psF - FAN STATIC PRESSURE (Pa)

300 87

84

86

30

1.2

200

87 84 84 86 86

pdF

20

0.8

100 84 12 16 3 20 85 24 4 87 28 32 5 36 6

10

0.4

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 -15 +1 -11 +5 -9 0 -6 +3 -1 +2 -2 +1 1K -1 -1 -1 -1 2K -5 -6 -5 -6 4K 8K -9 -18 -10 -17 -9 -15 -10 -14 8 - 18 -34 8 - 18 -8 20 - 36 -29 20 - 36 -3

86 0 0 3
pr - ABSORBED POWER (kW)

8 1 2

2 32 1 8 0 1 2 12 3 16 20 4 24 28

Extra performance only from plate mounted fans. Three blade performance available. See chart number 17

36

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2245 F2249 Pitch Angle () 16 - 20 24 - 30 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 1.3 2 3.2 8.2 11 18 Starting Current (A) 23 35 62 Pitch Angle () 12 24 - 26 Motor Rating (kW) 1.1 1.7 -

qv - VOLUME FLOW (m3/s)

Chart No. 18
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 7.2 23 ME1.10 10 33 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2245 Pitch Angle () 8 10 - 22 24 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.71 1.4 2.7 1.9 3.5 5.8
Y

6.5 14 30

16 - 18 26 - 30

1.15 2.1

3 4.7

11.4 30

ME3.2D -

18 30

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

29

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle -

AEROFOIL CLIMAFAN Fan Code: 71AC/8/3/... 710 mm 680 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 90

1000 2000
Pa rt 1

2000 4000

3000

4000 6000

5000 8000

6000 10000

7000 12000
BS848:Pt 1:80 V Type A

mm in wg 9

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K -28 -16 -7 -5 -6 -9 -14 -2 0 +2 -2 -6 -10 -15 -24 +2 -15 +1 -8 +1 -6 -3 -6 -6 -8 -11 -9 -12 8K -21 -20 -16 -15

BS

80

84

8 0.3 7

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

70

60
psF - FAN STATIC PRESSURE (Pa)

6 69 69 0.2

50

72

40 70 30 67 66 68 72 pdF

3 0.1

20

2 69

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -21 -13 -5 -3 -4 +5 -18 +8 +3 -11 +5 +4 -6 +3 0 -4 -1 -4 -4 -4 2K 4K -7 -11 8K -18

10 66 0 .25
pr - ABSORBED POWER (kW)

67 8 1.5 12 16 2.0

71

0.5

1.0

20 24 28 32 2.5 3.0

3.5

-8 -12 -17 -6 -8 -13 -7 -9 -12

.20 .15 .10 .05 0 0 0.5 1.0 8 1.5 12 2.0 16 24 20 28

32

Extra performance only from plate mounted fans.

2.5

3.0

3.5

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 Pitch Angle () 20 - 24 30 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.16 0.3 1.5 2.7 Starting Current (A) 2.5 3.5 Pitch Angle () 16 - 20 30 - 32 Motor Rating (kW) 0.13 0.25 -

qv - VOLUME FLOW (m3/s)

Chart No. 19
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 1.3 2.1 ME1.3 MT1.5 2.3 3.4 ME1.6 MT1.5 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 Pitch Angle () 8 - 24 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.16 0.3 0.8 1.4 Y

1.5 2.6 -

16 - 20 28 - 32 -

0.13 0.25 -

1.2 -

2.6 -

ME3.2D -

34 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

30

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.7 1.5 ME3.2D 20

AEROFOIL CLIMAFAN Fan Code: 71AC/8/6/... 710 mm 680 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 140


84 8

2000 4000
Pa rt 1

4000 8000

6000 12000

8000

10000 16000
BS848:Pt 1:80 V

mm in wg 14 0.5

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 63 125 8 - 18 -30 -17 8 - 18 -4 -1 20 - 36 -26 -16 20 - 36 0 0 Frequency Hz 250 500 1K -9 0 -9 0 -4 -1 -5 -2 -5 -5 -5 -5 2K 4K 8K -24 -23 -16 -15 -9 -16 -10 -17 -8 -12 -9 -13

BS

120

Type A
CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

12

100

10 68 71 pdF 8

0.4

psF - FAN STATIC PRESSURE (Pa)

80 69 60

0.3

68 67 68 70

6 0.2 4 69 0.1

40

20 69 68

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 1K -4 +5 -5 +4 -2 +1 -3 0 -3 -3 -3 -3 2K 4K 8K -20 -19 -13 -12
pr - ABSORBED POWER (kW)

68

70

8 - 18 -22 -11 8 - 18 +4 +5 20 - 36 -18 20 - 36 +8 -9 +7

-7 -13 -8 -14 -6 -9 -7 -10

0 .5 .4 .3 .2 .1 0

8 0 1

12 16 20 24 28 32 36 2 3 4

36 28 32

Extra performance only from plate mounted fans. Three blade performance available. See chart number 19

8 12 2

16

20

24

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 F2265 Pitch Angle () 10 - 14 18 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.16 0.3 1.5 2.7 Starting Current (A) 2.5 3.5 Pitch Angle () 8 - 10 18 - 22 34 - 36 Motor Rating (kW) 0.13 0.25 0.65

qv - VOLUME FLOW (m3/s)

Chart No. 20
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 1.3 2.1 ME1.3 MT1.5 2.3 4.9 3.4 12 ME1.6 ME1.6 MT1.5 MT1.8

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2265 Pitch Angle () 8 - 12 14 - 24 26 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.16 0.3 0.8 0.8 1.4 2.8
Y

1.5 2.6 8

8 - 10 18 - 22 34 - 36

0.13 0.25 0.65

1.2 2.4

2.6 8

ME3.2D ME3.2D

22 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

31

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.7 1.5 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 71AC/6/3/... 710 mm 900 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 160


rt

2000 4000
1 Pa

4000 8000

6000 12000

8000

10000 16000
BS848:Pt 1:80 V Type A

mm in wg 0.6

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K -27 -16 -8 -5 -6 -9 -1 0 +1 -2 -6 -10 -25 +1 -15 +1 -8 +1 -6 -3 -6 -6 -8 -9 4K 8K -13 -21 -14 -20 -11 -16 -12 -15

140

CAME Plate Mounted Fans Only

BS

84

15

Air Density 1.2 kg/m3

0.5 120

100
psF - FAN STATIC PRESSURE (Pa)

10 75 76 79 pdF

0.4

80 0.3 60 76 73 40 74 0.1 20 73 8 12 2 73 16 3 75 78 75 78 5 0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 -21 +5 -18 +8 125 250 500 -12 +4 -11 +5 -5 +4 -6 +3 -3 0 -4 -1 1K -4 -4 -4 -4 2K -7 -8 -6 -7 4K 8K -11 -18 -12 -17 -8 -13 -9 -12

20 24 28 32 4

0.6
pr - ABSORBED POWER (kW)

32 0.4 24 0.2 8 0 0 1 2 12 16 3 20 28

Extra performance only from plate mounted fans.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 Pitch Angle () 18 - 24 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.37 0.68 2.9 5.2 Starting Current (A) 4 6.5 Pitch Angle () 20 32 Motor Rating (kW) 0.3 0.52 -

qv - VOLUME FLOW (m3/s)

Chart No. 21
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.4 4 ME1.3 4 9.2 ME1.6 MT1.8 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 Pitch Angle () 8 - 24 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.37 0.68 1.3 2.2 Y

3.3 7.5 -

18 - 20 28 - 32 -

0.3 0.52 -

1.7 -

7.5 -

ME3.2D -

32 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

32

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.1 3.3 ME3.2D 20

AEROFOIL CLIMAFAN Fan Code: 71AC/6/6/... 710 mm 900 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 250


8

2000 4000
Pa rt 1

4000 8000

6000 12000

8000

10000 16000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 1.0 25

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 8 8 63 125 Frequency Hz 250 500 1K -5 -2 -6 -3 -4 -4 -5 -5 2K 4K 8K -22 -21 -17 -16 -8 -13 -9 -14 -7 -12 -8 -13 - 18 -35 -21 -12 - 18 -9 -5 -3

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

200

20

0.8

psF - FAN STATIC PRESSURE (Pa)

150 78

76

79

15

0.6

pdF 100 78 76 76 78 50 76 12 16 20 3 77 78 5 0.2 79 10 0.4

20 - 36 -29 -18 -10 20 - 36 -3 -2 -1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 Frequency Hz 125 250 500 1K 2K 4K -14 -5 -1 -2 -6 -11 +4 -4 +5 +2 -2 +1 -2 -3 -3 8K -19 63 - 18 -31

78 0 1.2
pr - ABSORBED POWER (kW)

8 2

24 28 32 36 4 5

8 - 18 -5 +2 20 - 36 -25 -10 20 - 36 +1 +6

-7 -12 -18 -6 -9 -14 -7 -10 -13

1.0 0.8 0.6 0.4 0.2 0 0 1 8 2 12 16 3 20 24 28 32 36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 21

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 F2265 Pitch Angle () 10 - 14 20 - 24 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.37 0.68 1.55 2.9 5.2 9.8 Starting Current (A) 4 6.5 27 Pitch Angle () 10 20 36 Motor Rating (kW) 0.3 0.52 1.35

qv - VOLUME FLOW (m3/s)

Chart No. 22
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.4 4 ME1.3 4 8.7 9.2 27 ME1.6 ME1.10 MT1.8 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2265 Pitch Angle () 8 - 12 14 - 24 26 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.37 0.68 1.55 1.3 2.2 4
Y

3.3 7.5 15

10 16 - 20 36

0.3 0.52 1.35

1.7 3.6

7.5 15

ME3.2D -

20 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

33

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.1 3.3 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 71AC/4/3/... 710 mm 1420 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 400


8 Pa rt 1 84

4000 5000 10000

8000 15000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 1.6 40

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -30 -21 -11 -4 -5 -4 -5 -2 -1 -5 -27 -1 -18 -10 -2 -1 -5 -2 -6 -6 2K 4K -8 -12 -9 -13 -8 -10 -9 -11 8K -19 -18 -16 -15

350

BS

1.4

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

300

30

1.2

psF - FAN STATIC PRESSURE (Pa)

250 88 90 200 pdF 150 89 86 100 87 88 91 10 91 20

1.0

0.8

0.6

0.4

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -24 -18 -7 -2 -3 +2 -21 +5 -2 -15 +1 +2 -7 +2 +1 -3 0 -3 -4 -4 2K 4K -6 -10 8K -17

50 86 0 2.5
pr - ABSORBED POWER (kW)

87 8 0 1 2 3 12 4 16 20 5

88

91 24 28 32 6 7

0.2

-7 -11 -16 -6 -8 -13 -7 -9 -12

2.0 1.5 1.0 0.5 0 0 1 2 3 8 12 4 16 20 24 28

32

Extra performance only from plate mounted fans.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT5 CT9 F2245 Pitch Angle () 8 - 12 18 - 22 26 - 30 Fixed Speed Motor Full Rating Load (kW) (A) 0.7 1.3 2 4.4 8.2 11 Starting Current (A) 9.5 23 35 Pitch Angle () 20 26 - 28 Motor Rating (kW) 1.1 1.7

qv - VOLUME FLOW (m3/s)

Chart No. 23
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 7.2 10 23 33 ME1.10 -

380-420 V / 50 Hz / 3
Motor CT5 CT9 F2265 Pitch Angle () 8 - 12 14 - 24 26 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.71 1.4 2.7 1.9 3.5 5.8
Y

6.5 14 30

8 - 10 18 - 20 28 - 32

0.58 1.15 2.1

3 4.7

11.4 30

ME3.2D -

20 32

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

34

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 6.5 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 71AC/4/6/... 710 mm 1440 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 600

4000 5000
Pa rt 1

8000 10000 15000

12000 20000

16000 25000 30000

20000 35000 mm in wg 2.4 60 2.2 50 2.0 1.8

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 63 125 -24 8 - 18 -38 8 - 18 -12 20 - 36 -34 20 - 36 -8 Frequency Hz 250 500 1K -16 -6 -3 -7 -4 -4 -4 -5 -5 2K -6 -7 -6 -7 4K 8K -11 -19 -12 -18 -10 -16 -11 -15

500

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

400 89
psF - FAN STATIC PRESSURE (Pa)

40 91

1.6 1.4

91 300 91 89 200 91 100 91 89 12 4 89 91 89 91

pdF 30

1.2 1.0

20

0.8 0.6

-8 -7 -19 -13 -3 -4

10

0.4 0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 1K -16 0 -11 +5 -9 0 -6 +3 -2 +1 -2 +1 -1 -1 -2 -2 2K -4 -5 -4 -5 4K 8K -9 -17 -10 -16 -8 -13 -9 -12 8 - 18 -34 8 - 18 -8 20 - 36 -30 20 - 36 -4

0 0 5
pr - ABSORBED POWER (kW)

8 2

16 20 24 6

28 32 36 8

10

4 3 2 1 0 8 0 2 12 4 16 20 6 24 28 32

36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 23.

10

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2245 F2249 Pitch Angle () 10 - 12 16 - 18 22 - 28 Fixed Speed Motor Full Rating Load (kW) (A) 1.3 2 3.2 8.2 11 18 Starting Current (A) 23 35 62 Pitch Angle () 10 14 - 16 Motor Rating (kW) 1.1 1.7 -

qv - VOLUME FLOW (m3/s)

Chart No. 24
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 7.2 23 ME1.10 10 33 -

380-420 V / 50 Hz / 3
Motor CT9 F2245 F2249 Pitch Angle () 8 - 12 14 - 24 26 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 1.4 2.7 4.4 3.5 5.8 9.3
Y

14 30 52

10 16 - 18 -

1.15 2.1 -

4.7 -

30 -

18 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

35

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 3 11.4 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 80AC/8/3/... 800 mm 680 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 90 2000


Pa rt

2000 4000

4000 6000 8000

6000

8000

10000 mm in wg 9 0.35

10000 12000 14000 16000


BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -29 -16 -8 -6 -6 -3 0 +1 -3 -6 -24 +2 -15 +1 -9 0 -7 -4 -6 -6 2K -8 -9 -7 -8 4K 8K -12 -20 -13 -19 -9 -14 -10 -13

BS

80

84

8 0.30 7 0.25

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

70

60
psF - FAN STATIC PRESSURE (Pa)

75 50

74 78 pdF

6 0.20

40

73 73 74 78 71

0.15

30

3 0.10 2

20 72 70 8 2 12 16 3 74

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 -23 +3 -19 +7 125 250 500 1K -12 +4 -11 +5 -6 +3 -6 +3 -4 -1 -5 -2 -4 -4 -4 -4 2K -6 -7 -5 -6 4K 8K -10 -17 -11 -16 -6 -11 -7 -10 pr - ABSORBED POWER (kW)

10

0.05 78 1

0 0.4 0.3 0.2

20 24 28 32 4

32 28 24 20 16 3 4 5

Extra performance only from plate mounted fans.

0.1 0 8 0 1 2 12

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 20 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 2.7 Starting Current (A) 3.5 Pitch Angle () 20 - 22 32 Motor Rating (kW) 0.25 0.65 -

qv - VOLUME FLOW (m3/s)

Chart No. 25
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.3 3.4 ME1.6 4.9 12 ME1.6 MT1.8 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 Pitch Angle () 8 - 24 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 1.4 2.8 Y

2.6 8 -

18 - 22 32 -

0.25 0.65 -

2.4 -

8 -

ME3.2D -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

36

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.2 2.6 ME3.2D 22

AEROFOIL CLIMAFAN Fan Code: 80AC/8/6/... 800 mm 695 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 160

2000 5000
Pa rt 1

4000

6000 10000

8000 15000

10000

12000 20000
BS848:Pt 1:80 V Type A

mm in wg 16 0.6 14 0.5

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 63 -32 -6 -27 -1 125 -18 -2 -17 -1 Frequency Hz 250 500 1K -9 0 -10 -1 -4 -1 -6 -3 2K 4K 8K -5 -9 -5 -10 -5 -5 -7 -8 -15 -24 -16 -23 -10 -16 -11 -15

140

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

120

12

100
psF - FAN STATIC PRESSURE (Pa)

10 73 74 77 pdF 8

0.4

80 74 60 72 74 40 75 76

0.3

6 0.2 4 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -24 -11 -5 -2 -3 +2 -19 +7 +5 -9 +7 +4 -5 +4 +1 -4 -1 -3 -4 -4 2K -8 -9 -5 -6 4K 8K -13 -21 -14 -20 -8 -13 -9 -12

20 75 0 0 0.8
pr - ABSORBED POWER (kW)

74 12 3 16 20

72

76

8 1 2

24 28 32 36 4 5 6

0.6 32 0.4 0.2 0 8 0 1 2 12 16 3


qv - VOLUME FLOW (m3/s)

36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 25.

28 20 4 24

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 12 - 16 28 - 34 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 2.7 5.9 Starting Current (A) 3.5 12 Pitch Angle () 12 22 - 30 Motor Rating (kW) 0.25 0.65 -

Chart No. 26
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.3 3.4 ME1.6 4.9 12 ME1.6 MT1.8 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 F2269 Pitch Angle () 8 - 14 16 - 34 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 1.4 1.4 2.8 4.7
Y

2.6 8 14

10 - 12 22 - 30 -

0.25 0.65 -

2.4 -

8 -

ME3.2D -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

37

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.2 2.6 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 80AC/6/3/... 800 mm 900 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 160

2000 4000
rt 1 Pa

4000 8000

6000

8000

10000 16000

12000 20000

14000 24000
BS848:Pt 1:80 V Type A

12000

mm in wg 16 0.6 14 0.5

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -29 -16 -8 -6 -5 -3 0 +1 -3 -5 -24 +2 -15 +1 -9 0 -7 -4 -6 -6 2K -8 -9 -7 -8 4K 8K -12 -20 -13 -19 -9 -15 -10 -14

140

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

120 pdF 100


psF - FAN STATIC PRESSURE (Pa)

12

82

81 85

10

0.4

80 80 60 79 78 80 84 40

0.3

6 0.2 4 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -22 -12 -5 -4 -3 +4 -19 +7 +4 -11 +5 +4 -6 +3 -1 -5 -2 -3 -4 -4 2K -6 -7 -5 -6 4K 8K -10 -17 -11 -16 -6 -12 -7 -11

20 77 0 8 0 1 2 3 12

78 16 4

80

84

20 24 28 32 5 6

pr - ABSORBED POWER (kW)

0.8 0.6 0.4 0.2 0 8 0 1 2 3 12 16 4


3

32 28 24 20

Extra performance only from plate mounted fans.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 20 - 24 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 5.2 9.8 Starting Current (A) 6.5 27 Pitch Angle () 20 Motor Rating (kW) 0.52 -

qv - VOLUME FLOW (m /s)

Chart No. 27
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.8 4 9.2 ME1.6 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 Pitch Angle () 8 - 24 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 2.2 4 Y

7.5 15 -

18 - 20 -

0.52 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

38

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 7.5 ME3.2D 20

AEROFOIL CLIMAFAN Fan Code: 80AC/6/6/... 800 mm 935 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 250

2000

4000

6000 10000

8000

10000

12000 20000

14000 16000 25000


BS848:Pt 1:80 V Type A

5000
Pa rt 1

15000

mm in wg 1.0 25
0.9 0.8 0.7

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 63 125 -36 -22 -10 -6 Frequency Hz 250 500 1K -12 -5 -4 -3 -2 -4 2K -8 -9 4K 8K -13 -22 -14 -21

200

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

20

82
psF - FAN STATIC PRESSURE (Pa)

150 83

83

85

pdF

15

0.6 0.5

100 83 84

81

85

10

0.4 0.3 0.2 0.1

50 84 82 12 4 16 20 5 82 85

20 - 36 20 - 36

-29 -19 -3 -3

-11 -2

-6 -3

-5 -5

-7 -8

-10 -15 -11 -14

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 1K 2K 4K 8K

8 - 18 8 - 18 20 - 36 20 - 36

-31 -15 -5 +1 -24 -11 +2 +5

-6 +3 -4 +5

-2 +1 -3 0

-2 -2 -3 -3

-6 -7 -5 -6

-11 -19 -12 -18 -8 -12 -9 -11

0 2.0
pr - ABSORBED POWER (kW)

8 3

24 28 32 36 6 7

36 1.5 1.0 24 0.5 0 8 0 1 2 3 12 4 16 5 20 28 32

Extra performance only from plate mounted fans. Three blade performance available. See chart number 27.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 F2269 Pitch Angle () 12 - 14 20 - 30 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 2.5 5.2 9.8 16 Starting Current (A) 6.5 27 48 Pitch Angle () 22 - 26 34 - 36 Motor Rating (kW) 1.35 2.1

qv - VOLUME FLOW (m3/s)

Chart No. 28
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 8.7 13 27 39 ME1.10 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 F2269 Pitch Angle () 8 - 14 16 - 30 32 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 2.5 2.2 4 6.3
Y

7.5 15 26

10 22 - 26 32 - 36

0.52 1.35 2.1

3.6 5.5

15 26

26 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

39

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 7.5 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 80AC/4/3/... 800 mm 1440 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 400

4000 5000
Pa rt 1

8000 10000 15000

12000 20000

16000 25000 30000

20000 35000 mm in wg 1.6 40

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -31 -21 -10 -5 -6 -5 -5 -1 -2 -6 -26 0 -17 -10 -1 -1 -6 -3 -6 -6 2K 4K 8K -8 -11 -18 -9 -12 -17 -8 -9 -9 -13 -10 -12

350

BS

84

CAME Plate Mounted Fans Only

35

1.4

Air Density 1.2 kg/m3

300

30 93 97 pdF 20 93

1.2

250
psF - FAN STATIC PRESSURE (Pa)

96

25

1.0

200

0.8

150 91

92

93 97

15

0.6

100

10

0.4

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -25 -18 -7 -3 -4 +1 -21 +5 -2 -15 +1 +2 -6 +3 0 -4 -1 -4 -4 -4 2K 4K 8K -6 -9 -15 -7 -6 -7 -10 -14 -7 -11 -8 -10

50 90 0 3.5
pr - ABSORBED POWER (kW)

92 8 0 2 4 12 6 16

94

96

0.2

20 24 28 32 0 10 8

3.0 2.5 2.0 1.5 1.0 0.5 0 0 2 4 8 12 6 16 20 24 28

32

Extra performance only from plate mounted fans.

10

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2245 F2249 Pitch Angle () 10 - 12 16 - 18 22 - 28 Fixed Speed Motor Full Rating Load (kW) (A) 1.3 2 3.2 8.2 11 18 Starting Current (A) 23 35 62 Pitch Angle () 16 Motor Rating (kW) 1.7 -

qv - VOLUME FLOW (m3/s)

Chart No. 29
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 10 33 -

380-420 V / 50 Hz / 3
Motor CT9 F2245 F2249 Pitch Angle () 8 - 12 14 - 24 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 1.4 2.7 4.4 3.5 5.8 9.3
Y

14 30 54

10 18 - 20 -

1.15 2.1 -

4.7 -

30 -

20 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

40

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 3 11.4 ME3.2D 10

AEROFOIL CLIMAFAN Fan Code: 80AC/4/6/... 800 mm 1440 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 700


Pa rt 1 8

5000 10000

10000 20000

15000 30000

20000

25000 40000
BS848:Pt 1:80 V Type A

mm in wg

2.6 60 2.4 2.2

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 63 125 8 - 18 -38 -26 8 - 18 -12 -10 20 - 36 -36 20 - 36 -10 -19 -3 Frequency Hz 250 500 1K -16 -7 -4 -7 -4 -4 -13 -4 -7 -4 -5 -5 2K -6 -7 -6 -7 4K 8K -11 -19 -12 -18 -9 -14 -10 -13

600

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

500

50

2.0 1.8

psF - FAN STATIC PRESSURE (Pa)

400 95 300 95

93 96 pdF

40

1.6 1.4

30 93 94 96 20

1.2 1.0 0.8 0.6

200

96

100 96 94 12 6 16 20 8 93 96

10

0.4 0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW Frequency Hz 63 125 250 500 1K -18 -2 -12 +4 -9 0 -6 +3 -2 +1 -2 +1 -1 -1 -2 -2 2K -4 -5 -4 -5 4K 8K -9 -16 -10 -15 -7 -12 -8 -11 pr - ABSORBED POWER (kW) 8 - 18 -34 8 - 18 -8 20 - 36 -31 20 - 36 -5

0 0 7 6 5 4 3 2 1 0 0

8 2 4

24 28 32 36 0 10 12

36 32 28 24 8 2 4 12 6
qv - VOLUME FLOW (m3/s)

Extra performance only from plate mounted fans. Three blade performance available. See chart number 29.

16

20

10

12

Electrical Data
220-240 V / 50 Hz / 1
Motor F2245 F2249 Pitch Angle () 10 14 - 18 Fixed Speed Motor Full Rating Load (kW) (A) 2 3.2 11 18 Starting Current (A) 35 62 Pitch Angle () Motor Rating (kW) -

Chart No. 30
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) -

380-420 V / 50 Hz / 3
Motor F2245 F2249 Pitch Angle () 8 - 14 16 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 2.7 4.4 5.8 9.3 Y

30 52 -

10 - 12 -

2.1 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

41

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 4.7 30 12

AEROFOIL CLIMAFAN Fan Code: 90AC/10/3/... 900 mm 550 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 70
8 Pa

2000 4000
rt 1

4000 8000

6000 12000

8000

10000 16000
BS848:Pt 1:80 V

mm in wg 7 0.25

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K 8K -28 -16 -8 -5 -5 -9 -13 -21 -2 0 +1 -2 -5 -10 -14 -20 -25 +1 -14 +2 -9 0 -5 -2 -6 -6 -8 -10 -16 -9 -11 -15

BS

84

60

Type A
CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

50 73 40 73 75 pdF 30 71 72 70 20 69 75

0.20

psF - FAN STATIC PRESSURE (Pa)

0.15

3 0.10 2 0.05

10 68 69 8 0 1 2 12 3 16

72

1 75

Outlet Levels
LWA Lw LWA LW Pitch Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K 8K -24 -13 -6 -3 -3 -7 -11 -18 +2 -21 +5 +3 -12 +4 +3 -6 +3 0 -3 0 -3 -4 -4 -8 -12 -17 -5 -8 -14 -6 -9 -13

20 24 28 32 0 5 4

pr - ABSORBED POWER (kW)

0.3 0.2 0.1 0 8 0 1 2 12 3 20 16 4

32 28 24

Extra performance only from plate mounted fans.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 12 - 16 30 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.14 0.4 1.7 3.4 Starting Current (A) 2.6 4.6 Pitch Angle () 10 - 12 30 - 32 Motor Rating (kW) 0.1 0.33 -

qv - VOLUME FLOW (m3/s)

Chart No. 31
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 1.3 1.8 ME1.3 2.9 4.1 ME1.3 MT1.5 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 Pitch Angle () 8 - 16 18 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.14 0.4 0.9 1.9 Y

1.6 3.8 -

10 - 12 28 - 32 -

0.1 0.33 -

1.7 -

3.8 -

ME3.2D -

32 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

42

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 0.7 1.3 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 90AC/10/6/... 900 mm 550 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 120

2000 5000
Pa rt 1

4000

6000 10000

8000

10000

12000 20000

14000

15000

mm in wg in mm 25000 wg 12

BS848:Pt 1:80 V Type A

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K -28 -16 -8 -4 -5 -10 -2 0 +1 -1 -5 -11 -25 +1 -14 +2 -9 0 -5 -2 -5 -5 -7 -8 4K 8K -16 -25 -17 -24 -11 -18 -12 -17

100

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

10

0.4

80
psF - FAN STATIC PRESSURE (Pa)

8 0.3 72 75 pdF 6 0.2 71 71 71 0.1 74 4

60 71 40

72

20 71 71 12 3 16 20 4 71 74

Outlet Levels
LWA Lw LWA LW Pitch Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -21 -11 -5 -2 -3 +5 -18 +8 +5 -9 +7 +4 -6 +3 +1 -3 0 -3 -3 -3 2K -8 -9 -5 -6 4K 8K -14 -21 -15 -20 -9 -14 -10 -13

8 0 1 2

24 28 32 36 5 6

pr - ABSORBED POWER (kW)

0.6 32 0.4 0.2 0 8 0 1 2 12 3 16 4 20 24 28

36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 31.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 14 - 18 30 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 2.7 5.9 Starting Current (A) 3.5 12 Pitch Angle () 14 24 - 32 Motor Rating (kW) 0.25 0.65 -

qv - VOLUME FLOW (m3/s)

Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.3 3.4 ME1.6 4.9 12 ME1.6 MT1.8 -

Chart No. 32

380-420 V / 50 Hz / 3
Motor CT9 F2265 Pitch Angle () 8 - 18 20 - 32 -

0.3 0.8 -

1.4 2.8 Y

2.6 8 -

12 - 14 24 - 32 -

0.25 0.65 -

2.4 -

8 -

ME3.2D -

32 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

43

Fixed Speed Motor Full Rating Load (kW) (A)

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.2 2.6 ME3.2D 14

AEROFOIL CLIMAFAN Fan Code: 90AC/8/3/... 900 mm 695 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 120

2000 5000
Pa rt 1

4000

6000 10000

8000

10000

12000 20000

14000 25000
BS848:Pt 1:80 V Type A

15000

mm in wg

12

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K -28 -16 -9 -5 -5 -9 -2 0 0 -2 -5 -10 -25 +1 -14 +2 -9 0 -6 -3 -6 -6 -8 -9 4K 8K -13 -21 -14 -20 -10 -16 -11 -15

100

CAME Plate Mounted Fans Only

BS

84 8

Air Density 1.2 kg/m3

10

0.4

80
psF - FAN STATIC PRESSURE (Pa)

8 0.3 78 pdF 81 76 6 0.2 78 76 75 0.1 81 4

60

78

40

20 74 75 8 0 1 2 3 12 16 4 78 80

Outlet Levels
LWA Lw LWA LW Pitch Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 -24 +2 -21 +5 125 250 500 1K -13 -6 -3 -3 +3 -11 +5 +3 -6 +3 0 -4 -1 -3 -4 -4 2K -7 -8 -6 -7 4K 8K -11 -18 -12 -17 -8 -14 -9 -13 pr - ABSORBED POWER (kW)

20 24 28 32 5 6

0.6 28 0.4 0.2 0 8 0 1 2 3 12 4 20 16 5 6 24

32

Extra performance only from plate mounted fans.

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 14 - 18 30 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 2.7 5.9 Starting Current (A) 3.5 12 Pitch Angle () 20 - 22 24 - 32 Motor Rating (kW) 0.25 0.65 -

qv - VOLUME FLOW (m3/s)

Chart No. 33
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.3 3.4 ME1.6 4.9 12 ME1.6 MT1.8 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 Pitch Angle () 8 - 18 20 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.3 0.8 1.4 2.8 Y

2.6 8 -

12 - 14 24 - 32 -

0.25 0.65 -

2.4 -

8 -

ME3.2D -

32 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

44

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.2 2.6 ME3.2D 14

AEROFOIL CLIMAFAN Fan Code: 90AC/8/6/... 900 mm 695 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 200


84 8

4000 5000
Pa rt 1

8000 10000 15000

12000 20000

16000 25000
BS848:Pt 1:80 V Type A

mm in wg 0.8 20

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K -30 -18 -10 -4 -5 -9 -4 -2 -1 -1 -5 -10 -25 +1 -15 -10 +1 -1 -6 -3 -5 -5 -7 -8 4K 8K -15 -24 -16 -23 -11 -17 -12 -16

BS

180 160

0.7

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

15 140 120 79 100 80 60 78 40 20 77 24 6 81 28 32 36 0 8 7 79 82 pdF 10

0.6

0.5

psF - FAN STATIC PRESSURE (Pa)

0.4

78 78 78 5 81

0.3

0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -23 -13 -6 -2 -3 +3 -19 +7 +3 -11 +5 +3 -6 +3 +1 -3 0 -3 -3 -3 2K -7 -8 -5 -6 4K 8K -13 -20 -14 -19 -9 -14 -10 -13
pr - ABSORBED POWER (kW)

0.1

78 1 2 8 3

78 12 16 20 4 5

0 0

1.2 32 0.8 0.4 0 8 0 1 2 3 12 4 16 5 24 20 6 7 28

36

Extra performance only from plate mounted fans. Three blade performance available. See chart number 33.

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 18 - 24 30 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 5.9 10 Starting Current (A) 12 20 Pitch Angle () 14 - 20 28 - 30 Motor Rating (kW) 0.65 1.1 -

qv - VOLUME FLOW (m3/s)

Chart No. 34
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 4.9 12 ME1.6 MT1.8 8.2 19.5 ME1.10 MT1.8 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 22 24 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 2.8 4.7 Y

8 14 -

14 - 20 26 - 30 -

0.65 1.1 -

3.8 -

14 -

30 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

45

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 2.4 8 ME3.2D 20

AEROFOIL CLIMAFAN Fan Code: 90AC/6/3/... 900 mm 935 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 200


84 8

4000 5000
Pa rt 1

8000 10000 15000

12000 20000

16000 25000 30000


BS848:Pt 1:80 V Type A

mm in wg 0.8 20

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K 8K -28 -16 -9 -5 -5 -9 -13 -21 -2 0 0 -2 -5 -10 -14 -20 -25 +1 -14 +2 -9 0 -6 -3 -6 -6 -8 -9 -10 -16 -11 -15

BS

180 160

0.7

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

15 140
psF - FAN STATIC PRESSURE (Pa)

0.6

120 85 100 83 80

85 pdF 88 10

0.5

0.4

85 83 60 82 40 20 82 8 4 12 5 16 6 85 87 88 5

0.3

0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K 8K -24 -13 -6 -3 -3 -7 -11 -18 +2 -21 +5 +3 -11 +5 +3 -6 +3 0 -4 -1 -3 -4 -4 -8 -6 -7 -12 -17 -8 -14 -9 -13
pr - ABSORBED POWER (kW)

0.1

81

0 2.0 1.5 1.0 0.5 0

20 24 28 32 7 8

32 28 24 12 5 16 6 20

Extra performance only from plate mounted fans.

8 0 1 2 3 4

Electrical Data
220-240 V / 50 Hz / 1
Motor CT9 F2265 Pitch Angle () 14 - 16 22 - 30 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 5.2 9.8 Starting Current (A) 6.5 27 Pitch Angle () 24 - 28 Motor Rating (kW) 1.35 -

qv - VOLUME FLOW (m3/s)

Chart No. 35
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 8.7 27 ME1.10 -

380-420 V / 50 Hz / 3
Motor CT9 F2265 F2269 Pitch Angle () 8 - 16 18 - 30 32 Fixed Speed Motor Full Rating Load (kW) (A) 0.68 1.55 2.5 2.2 4 6.3
Y

7.5 15 26

12 24 - 28 -

0.52 1.35 -

3.6 -

15 -

28 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

46

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 7.5 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 90AC/6/6/... 900 mm 935 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 350


8 Pa rt

5000 10000
1

10000 20000

15000 30000

20000

25000 40000
BS848:Pt 1:80 V Type A

mm in wg 1.4 35

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -35 -21 -12 -6 -4 -9 -5 -3 -3 -4 -28 -18 -10 -2 -2 -1 -6 -3 -5 -5 2K -7 -8 -7 -8 4K 8K -13 -21 -14 -20 -10 -16 -11 -15

BS

84

300

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

30

1.2

250

25

1.0

psF - FAN STATIC PRESSURE (Pa)

200 88 150 87

88

90 pdF

20

0.8

15 87 90 10 87

0.6

100

87

0.4

50 87 86 12 16 6 20 87 89

0.2

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -32 -15 -7 -2 -2 -6 +1 -26 -11 0 +5 +2 -5 +4 +1 -3 0 -2 -3 -3 2K -5 -6 -5 -6 4K 8K -11 -19 -12 -18 -8 -14 -9 -13

0 0

8 4

24 28 32 36 8 10

12

pr - ABSORBED POWER (kW)

3.0 2.0 1.0 0 8 0 2 4 12 16 6


qv - VOLUME FLOW (m3/s)

36 32 28 20 24

Extra performance only from plate mounted fans. Three blade performance available. See chart number 35.

10

12

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 12 - 18 22 - 28 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 9.8 16 Starting Current (A) 27 48 Pitch Angle () 14 - 16 22 - 24 Motor Rating (kW) 1.35 2.1 -

Chart No. 36
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 8.7 27 ME1.10 13 39 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 18 20 - 28 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 4 6.3 Y

15 26 -

14 - 16 22 - 24 -

1.35 2.1 -

5.5 -

26 -

24 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

47

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 3.6 15 16

AEROFOIL CLIMAFAN Fan Code: 100AC/10/3/... 1000 mm 550 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 80

2000 5000
Pa rt 1

4000

6000 10000

8000

10000

12000 20000

14000 25000
BS848:Pt 1:80 V Type A

15000

mm in wg 8 0.3 7

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K -26 -16 -9 -5 -5 -9 -15 0 0 0 -2 -5 -10 -16 -25 -13 +1 +3 -10 -1 -4 -1 -6 -9 -12 -6 -10 -13 8K -23 -22 -19 -18

70

CAME Plate Mounted Fans Only

BS

84

Air Density 1.2 kg/m3

60

50
psF - FAN STATIC PRESSURE (Pa)

5 pdF 75

0.2

40

76

30

73 74 76 78

3 0.1 2 73 78

20

10 72 8 3 12

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -22 -13 -7 -3 -3 +4 +3 -21 -11 +5 +5 +2 -7 +2 0 -2 +1 -3 -4 -4 2K 4K -7 -12 -8 -13 -7 -10 -8 -11 8K -20 -19 -16 -15

71

76

0 0.6
pr - ABSORBED POWER (kW)

78 16 20 24 28 32 4 5 6

32 0.4 24 0.2 8 0 1 2 3 12 4 16 20 28

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 22 - 26 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.4 0.7 3.4 5.7 Starting Current (A) 4.6 8 Pitch Angle () 20 - 22 28 - 34 Motor Rating (kW) 0.33 0.55 -

qv - VOLUME FLOW (m3/s)

Chart No. 37
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.9 4.1 ME1.3 4.7 6.6 ME1.6 MT1.5 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 26 28 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.4 0.7 1.9 3.3 Y

3.8 8 -

20 - 22 28 - 34 -

0.33 0.55 -

2.7 -

6 -

ME3.2D -

34 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

48

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 3.8 ME3.2D 22

AEROFOIL CLIMAFAN Fan Code: 100AC/10/6/... 1000 mm 550 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 120


84

4000 5000
rt 1 Pa

8000 10000 15000

12000 20000

16000 25000 30000


BS848:Pt 1:80 V Type A

mm in wg 12 0.45 0.4

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K -25 -15 -9 -4 -5 -10 -16 +1 +1 0 -1 -5 -11 -17 -23 +3 -13 +3 -9 0 -5 -2 -6 -6 -8 -12 -9 -13 8K -24 -23 -18 -17

100

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

10

80
psF - FAN STATIC PRESSURE (Pa)

77 60 75

78

pdF

8 0.3

80

6 0.2

40 75

75

77 4 79 0.1

20 74 75 12 4 16 5 76 78

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -19 -12 -6 -3 -3 +7 -17 +9 +4 -10 +6 +3 -6 +3 0 -4 -1 -3 -4 -4 2K 4K -8 -13 -9 -14 -6 -10 -7 -11 8K -21 -20 -16 -15

0 1.2
pr - ABSORBED POWER (kW)

8 0 1 2 3

20 24 28 32 36 6 7 8

36 0.8 24 8 0 1 2 3 4 12 16 5 20 32 28

0.4

Three blade performance available. See chart number 37.

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 14 20 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.4 0.7 3.4 5.7 Starting Current (A) 4.6 8 Pitch Angle () 10 - 12 18 - 20 Motor Rating (kW) 0.33 0.55 -

qv - VOLUME FLOW (m3/s)

Chart No. 38
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.5 2.9 4.1 ME1.3 4.7 6.6 ME1.6 MT1.5 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 14 16 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.4 0.7 1.9 3.3 Y

3.8 8 -

10 - 12 18 - 20 -

0.33 0.55 -

2.7 -

6 -

ME3.2D -

20 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

49

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 1.7 3.8 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 100AC/8/3/... 1000 mm 695 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 120


8 84

4000 5000
rt 1 Pa

8000 10000 15000

12000 20000

16000 25000 30000


BS848:Pt 1:80 V Type A

mm in wg 12 0.45

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch Angle LWA LW LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 63 125 -26 -16 0 0 -26 -14 0 +2 Frequency Hz 250 500 1K -9 0 -10 -1 -5 -2 -5 -2 2K 4K 8K -23 -22 -19 -18 -5 -10 -15 -5 -11 -16 -6 -9 -12 -6 -10 -13

100

CAME Plate Mounted Fans Only

BS

Air Density 1.2 kg/m3

10

0.4

80
psF - FAN STATIC PRESSURE (Pa)

8 0.3 81 82 pdF 6 79 0.2 79 82 84 4

60

40 78

83 20 77 82 84 12 4 5 16 6 20 24 28 32 7 8 9 0 77 2

0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -7 +2 -7 +2 -3 0 -3 0 -3 -3 -4 -4 2K 4K 8K -20 -19 -16 -15 -22 -13 +4 +3 -21 -11 +5 +5 -7 -12 -8 -13 -7 -10 -8 -11

0 1.2
pr - ABSORBED POWER (kW)

8 0 1 2 3

32 0.8 24 0.4 8 4 12 5 16 6 20 28

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 22 - 26 34 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 5.9 10 Starting Current (A) 12 20 Pitch Angle () 16 - 22 30 - 34 Motor Rating (kW) 0.65 1.1 -

qv - VOLUME FLOW (m3/s)

Chart No. 39
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.8 4.9 12 ME1.6 8.2 19.5 ME1.10 MT1.8 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 26 28 - 36 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 2.8 4.7 Y

8 14 -

16 - 22 30 - 34 -

0.65 1.1 -

3.8 -

14 -

34 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

50

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 2.4 8 ME3.2D 22

AEROFOIL CLIMAFAN Fan Code: 100AC/8/6/... 1000 mm 695 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 200


8 Pa rt

5000 10000
1

10000 20000

15000 30000

20000

25000 40000
BS848:Pt 1:80 V Type A

mm in wg 0.8 20 18 16 0.6 14 0.5 12 10 8 0.4

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K 2K 4K -27 -16 -10 -5 -4 -10 -15 -1 0 -1 -2 -4 -11 -16 -24 +2 -14 -10 +2 -1 -5 -2 -5 -9 -12 -5 -10 -13 8K -23 -22 -18 -17

BS

180 160 140


psF - FAN STATIC PRESSURE (Pa)

84

0.7

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

120 84 100 82 80 82 60 81 40 20

85 87

pdF

0.3

84 86 6 0.2 4 82 82 84 2 0 0.1

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 -20 +6 -18 +8 125 250 500 1K -15 -6 -3 -2 +1 -12 +4 +3 -5 +4 0 -3 0 -2 -3 -3 2K 4K -7 -13 -8 -14 -6 -10 -7 -11 8K -20 -19 -15 -14

81 8 0 2 4 12

0 2.5
pr - ABSORBED POWER (kW)

16 6

20 24 28 32 36 8 10 12

2.0 1.5 1.0 0.5 0 8 0 2 4 12 6 16 20 8 28 24 32

36

Three blade performance available. See chart number 39.

10

12

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 12 - 14 20 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 5.9 10 Starting Current (A) 12 20 Pitch Angle () 10 - 12 18 - 20 Motor Rating (kW) 0.65 1.1 -

qv - VOLUME FLOW (m3/s)

Chart No. 40
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) MT1.8 4.9 12 ME1.6 8.2 19.5 ME1.10 MT1.8 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 14 16 - 24 Fixed Speed Motor Full Rating Load (kW) (A) 0.8 1.4 2.8 4.7 Y

8 14 -

10 - 12 18 - 20 -

0.65 1.1 -

3.8 -

14 -

20 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

51

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 2.4 8 ME3.2D 12

AEROFOIL CLIMAFAN Fan Code: 100AC/6/3/... 1000 mm 935 rev/min 3 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 200


8 Pa rt 1

5000 10000

10000 20000

15000 30000

20000

25000 40000
BS848:Pt 1:80 V

mm in wg 0.8 20
18

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K 2K 4K 8K -26 -16 -9 -5 -5 -10 -14 -23 0 0 -26 -14 0 +2 0 -10 -1 -2 -4 -1 -5 -11 -15 -22 -6 -9 -12 -19 -6 -10 -13 -18

BS

180 160 140 120 100 80 60

84

Type A
CAME Plate Mounted Fans Only

0.7

Air Density 1.2 kg/m3

16 0.6 14 88 89

pdF
12 10

0.5

psF - FAN STATIC PRESSURE (Pa)

0.4

86 86 89 91 8 6 85 0.2 91 84 85 8 0 2 4 6 12 16 8 89 91 20 24 28 32 10 12 4 0.1 2 0 0 0.3

40 20

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 32 20 - 32 Frequency Hz 63 125 250 500 1K -7 +2 -7 +2 -3 0 -2 +1 -3 -3 -4 -4 2K 4K 8K -22 -13 +4 +3 -21 -11 +5 +5 -7 -12 -20 -8 -13 -19 -7 -10 -16 -8 -11 -15

0 3
pr - ABSORBED POWER (kW)

32 2 24 1 8 0 2 4 6
qv - VOLUME FLOW (m3/s)

28 20 12 16 8 10 12

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 16 - 22 26 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 9.8 16 Starting Current (A) 27 48 Pitch Angle () 16 - 20 26 - 28 Motor Rating (kW) 1.35 2.1 -

Chart No. 41
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 8.7 27 ME1.10 13 39 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 22 24 - 32 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 4 6.3 Y

15 26 -

16 - 20 26 - 28 -

1.35 2.1 -

5.5 -

26 -

28 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

52

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 3.6 15 20

AEROFOIL CLIMAFAN Fan Code: 100AC/6/6/... 1000 mm 935 rev/min 6 Blades 50 Hz


BS 5750 Pt 1 EN 29001 ISO 9001

Performance Data BS 848 Pt 1 1980


Performance shown is specifically for non-ducted installations.

ft3/min 0 m3/hr 0 350

5000 10000
Pa rt 1

10000 20000

15000

20000

25000 40000

30000 50000
BS848:Pt 1:80 V Type A

30000

mm in wg 1.4 35

Sound Data BS 848 Pt 2 1985


Single figures on performance curves are overall inlet sound power levels, "A" weighted ( LWA re: 1 pW ), derived from measurements taken in Woods laboratory specifically under non-ducted free field conditions. For sound power levels in eight octave bands, apply the following corrections to the overall level: Inlet Levels
Pitch LWA LW LWA LW Angle 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -35 -18 -11 -6 -4 -9 -2 -2 -3 -4 -28 -17 -2 -1 -9 0 -6 -3 -5 -5 2K -7 -8 -8 -9 4K 8K -13 -21 -14 -20 -11 -18 -12 -17

BS

84

300

CAME Plate Mounted Fans Only

Air Density 1.2 kg/m3

30

1.2

250 pdF
psF - FAN STATIC PRESSURE (Pa)

25

1.0

200

93

94 20 96

0.8

150

91 91 90 93 95

15

0.6

100

10

0.4

50 90 91 12 6 16 8

Outlet Levels
Pitch Angle LWA Lw LWA LW 8 - 18 8 - 18 20 - 36 20 - 36 Frequency Hz 63 125 250 500 1K -33 -12 -9 -3 -3 -7 +4 -26 -11 0 +5 0 -7 +2 0 -2 +1 -3 -4 -4 2K -5 -6 -6 -7 4K 8K -11 -18 -12 -17 -9 -15 -10 -14

92

5 94 0

0.2

0 6
pr - ABSORBED POWER (kW)

8 0 2 4

20 2428 32 36 10 12 14

16

36 4 28 2 8 6 12 8 16 24 20 10 12 14 16 32

Three blade performance available. See chart number 41.

Electrical Data
220-240 V / 50 Hz / 1
Motor F2265 F2269 Pitch Angle () 8 - 10 16 - 18 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 9.8 16 Starting Current (A) 27 48 Pitch Angle () 10 16 Motor Rating (kW) 1.35 2.1 -

qv - VOLUME FLOW (m3/s)

Chart No. 42
Speed Controllable Full Starting Speed Controller Load Current AutoElectronic Transformer (A) (A) 8.7 27 ME1.10 13 39 -

380-420 V / 50 Hz / 3
Motor F2265 F2269 Pitch Angle () 8 - 10 12 - 18 Fixed Speed Motor Full Rating Load (kW) (A) 1.55 2.5 4 6.3 Y

15 26 -

10 16 -

1.35 2.1 -

5.5 -

26 -

16 -

* By connecting these 3 phase motors in star ( ), a second speed will be obtained approximately 80% of the full speed at the angle shown. (A Woods two speed switch type MDS3.10 is available). For dimensions and weights of this fan please refer to pages 54 and 55.

53

Starting Current (A)

Pitch Angle ()

Motor Rating (kW)

Speed Controllable Full Starting Speed Control Load Current / * Electronic (A) (A) Pitch Angle 3.6 15 10

AEROFOIL CLIMAFAN DIMENSIONS AND WEIGHTS


PLATE MOUNTED
2 HOLES 6 mm IN ARMS TO ATTACH LEADS IF REQUIRED.

CA 137 31
MAX

CB D 137 31
MAX

E K S No. OF HOLES T.

FF OVER BELLMOUTH

F OVER BELLMOUTH

A SQ. CRS

G CRS

AIRFLOW FORM A

GUARD WHEN FITTED BT/CT MOTORS 3 SUPPLY: 2 COMPRESSION GLANDS CM16 & CM20. 1 SUPPLY: 1 GLAND CM20 . CM20 COMPRESSION GLAND SUITABLE FOR CABLE 8-13 mm. CM16 SUITABLE FOR CABLE 4-7 mm.

ROTATION

F22 MOTORS ENTRY FOR CM25 CONDUIT SUITABLE FOR CABLE 8-13 mm.

Code 500

Motor Frame BT4/5 BT9 CT5 CT9 F2225 F2229 CT5 CT9 CT5 CT9 F2245/65 F2249/69 CT5 CT9 F2245/65 F2249/69 CT9 F2245/65 F2249/69 CT9 F2245/65 F2249/69 F2245/65 F2249/69

A 638 638 638 638 638 638 698 698 768 768 768 768 848 848 848 848 966 966 966 1062 1062 1062 1207 1207

B 678 678 678 678 678 678 738 738 808 808 808 808 888 888 888 888 1000 1000 1000 1100 1100 1100 1245 1245

CA 430 465 440 480 537 591 440 480 410 450 507 561 410 450 507 561 450 507 561 450 507 561 507 561

CB 403 438 413 453 510 564 413 453 413 453 510 564 413 453 510 564 453 510 564 453 510 564 510 564

D 170 205 180 220 277 331 180 220 180 220 277 331 180 220 277 331 220 377 331 220 277 331 277 331

E 266 301 276 316 373 427 276 316 276 316 373 427 276 316 373 427 316 373 427 316 373 427 373 427

F 598 598 598 598 598 598 658 658 728 728 728 728 808 808 808 808 898 898 898 998 998 998 1098 1098

FF 594 594 594 594 594 594 654 654 724 724 724 724 804 804 804 804 894 894 894 994 994 994 1094 1094

G 322 322 322 354 354 354 381 381

K 123 123 123 123 123 123 123 123 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93 93

S 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 12 12 12 12 12 12 12 12

T 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 14 14

Weight kg 20 21 22 26 33 44 24 28 26 30 38 49 28 32 39 50 35 43 54 38 46 57 53 64

560 630

710

800

900

1000

All dimensions in millimetres

54

B SQ.

AEROFOIL CLIMAFAN DIMENSIONS AND WEIGHTS


SHORT CASED
BT/CT MOTORS 3 SUPPLY: 2 COMPRESSION GLANDS CM16 & CM20. 1 SUPPLY: 1 GLAND CM20. CM20 COMPRESSION GLAND SUITABLE FOR CABLE 8-13 mm . CM16 SUITABLE FOR CABLE 4-7 mm. WHERE IMPELLER SIDE GUARD IS FITTED ON THE MOTOR SIDE, THE GUARD ENCLOSES THE MOTOR.

C F 225 F

F22 MOTORS ENTRY FOR CM25 CONDUIT SUITABLE FOR CABLE 8-13 mm.

S No. OF HOLES T . EQUISPACED ON H PCD.

B OVER FLANGES

FORM A AIRFLOW FORM B

A INSIDE

AIRFLOW

HOLE 15 mm PROVIDED IN THE DUCT FOR SUPPLY LEADS.

GUARDS WHEN FITTED

Code 500

Motor Frame BT4/5 BT9 CT5 CT9 F2225 F2229 CT5 CT9 CT5 CT9 F2245/65 F2249/69 CT5 CT9 F2245/65 F2249/69 CT9 F2245/65 F2249/69 CT9 F2245/65 F2249/69 F2245/65 F2249/69

A 500 500 500 500 500 500 560 560 630 630 630 630 710 710 710 710 800 800 800 900 900 900 1000 1000

B 594 594 594 594 594 594 654 654 724 724 724 724 804 804 804 804 894 894 894 994 994 994 1106 1106

C 301 333 308 348 404 459 308 348 308 348 404 459 308 348 404 459 348 404 459 348 404 459 404 459

E 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3

F 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137

H 560 560 560 560 560 560 620 620 690 690 690 690 770 770 770 770 860 860 860 970 970 970 1070 1070

S 12 12 12 12 12 12 12 12 12 12 12 12 16 16 16 16 16 16 16 16 16 16 16 16

T 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12 15 15

U* 541 541 541 541 541 541 601 601 671 671 671 671 751 751 751 751 841 841 841 941 941 941 1041 1041

Weight kg 17 18 23 26 33 44 24 27 27 30 37 48 29 32 41 51 37 44 55 40 47 58 52 63

560 630

710

800

900

1000

* Recommended customer plate opening diameter All dimensions in millimetres

55

AEROFOIL CLIMAFAN ANCILLARIES


SILENCER - B TYPE
Suitable for fan Code 500
B A

A 500 560 630 710 800 900 1000

B 650 710 780 860 1000 1100

C 500 560 630 710 800 900

Weight (kg) B type 25 30 35 44 55 70 82

560 630 710 800


C DRILLINGS TO MATCH FAN FLANGES

900 1000

1200 1000

The above silencers give the following approximate dB(A) reductions:B Type 1 diameter length - 7 to 10 dB(A) For full acoustic details see publication AF1.3c or contact our Woods Acoustic Department. Tel: +44 (0) 1206 544122.

MATCHING FLEXIBLE DAMPER FLANGE CONNECTION


D 2 E G F 2

Suitable for fan Code 500 560 630 710 800 900 1000

Weight (kg) D E F G Matching Flexible Flange Connection 2.0 2.3 3.0 3.2 3.6 4.1 4.6 4.8 5.5 7.5 8.1 9.1 10.4 11.6 Damper 14 15 17 19 21 24 27

32 32 50 50 50 50 50

110 110 160 160 160 160 160

225 225 225 225 225 225 225

75 125 176 210 266 301 345

SPEED CONTROLLER
Type ME1.1
A C D

A 104 148 148 124 160 160 160 160 160 160

B 83 87 87 124 270 270 270 270 270 270

C 55 62 62 60 196 196 196 196 196 196

D 40 47 47 52 161 161 161 161 161 161

ME1.3 ME1.6 MT1.1 MT1.2

SPEED CONTROLLER

MT1.5 MT1.8
B

MT3.0.5 MT3.1 MT3.2D

56

AEROFOIL CLIMAFAN USEFUL INFORMATION

FAN LAWS

SPEED CHANGE - CONSTANT SIZE - CONSTANT DENSITY Volume Flow Rotational Speed Pressure (Static, Velocity and Total) (Rotational Speed)2 Power Absorbed (Rotational Speed)3 SIZE CHANGE - CONSTANT SPEED - CONSTANT DENSITY (For geometrically similar fans only) Volume Flow (Impeller Diameter)3 Pressure (Static, Velocity and Total) (Impeller Diameter)2 Power Absorbed (Impeller Diameter)5 DENSITY CHANGE - CONSTANT SPEED - CONSTANT SIZE Volume Flow = No change Pressure (Static, Velocity and Total) Density Power Absorbed Density The laws can be combined where simultaneous changes in size speed and density are required.

AIR DENSITY

Standard density is 1.2 kg/m3

One condition which gives standard air is:16C, 100 kPa barometric pressure, 65% relative humidity
CHANGE DUE TO TEMPERATURE Density 2 = Density 1 x

( (

273 + Temperature 1 C 273 + Temperature 2C


4.256

kg/m3

CHANGE DUE TO ALTITUDE Density 2 = Density 1 x 288 - 0.00649 H 288

kg/m3

Where H = Height above sea level in metres

PRESSURE

Pd Where

= 0.5V2 Pa = Air Density kg/m3

V Pf

= =

Air Velocity m/s Ps + Pd qv (m3/s) x Pf (Pa)

ABSORBED POWER

Absorbed Power = Total Efficiency % x10

kW

57

AEROFOIL CLIMAFAN USEFUL INFORMATION


CONVERSIONS
ft2 100 90 8 80 7 70 6 60 5 50 4 40 4000 5000 5 500 50 6000 7000 3.0 6 600 3.0 60 4 5 5 2.0 4 1000 900 1 3 30 3000 3 700 2 600 2 20 2000 0.9 0.8 400 0.7 0.7 1 0.6 300 1 10 1 ft2 = 0.0929 m2 1000 0.5 1 100 1 ft/min. = 0.00508 m/s 10 1 gpm (UK) = 0.0757 I/s 1 in. wg 1 ft3/min = 0.00047 m3/s = 249 Pa 0.6 0.9 0.8 1 1 BTU = 1.055 kJ 1 0.3 0.3 -50 1000 1 10 1 mm wg 1 m3/h = 0.000278 m3/s = 9.806 Pa 0.4 0 0.8 0 0.4 1.0 2 500 200 1.0 0.9 0.5 50 20 2 2 0.5 2 800 300 30 3 3 3 0.9 0.8 0.7 0.6 100 2000 150 0.7 50 0.6 2 20 400 2.0 40 3 4 4 200 4 100 4000 1 0.9 3000 0.8 3 30 4 5 250 40 5000 5 50 6 6 7 700 8000 m2 9 ft3/min m3/s in. wg 10000 9000 4.0 8 2000 800 4.0 80 70 5 6 8 8 7 7 6 7 2 300 150 10 9 Pa ft/min 1000 900 m/s 5.0 gpm (UK) I/s 100 90 7 BTU 10 10 9 9 8 350 7000 6000 2 7 70 60 8000 8 80 9 kJ BTU/h 10 400 200 J/s F C m3/h m3/s mm wg 10000 9000 10 9 90 Pa

1 BTU/hr = 0.293 J/s

1st Numeral Designation Protection against contact and ingress of foreign bodies. Protection against contact with live or moving parts of tools,wires or other objects of thickness greater than 1mm. Protection against the ingress of solid foreign bodies with a diameter greater than 1mm. Complete protection against contact with live or moving parts inside the enclosure. Protection against harmful deposits of dust. The ingress of dust is not totally prevented, but dust cannot enter in an amount sufficient to interfere with satisfactory operation of the machine.

2nd Numeral Protection against water. Water splashed against the motor from any direction shall have no harmful effect.

MOTOR ENCLOSURES DEGREES OF PROTECTION


IP44

IP54

Water splashed against the motor from any direction shall have no harmful effect.

IP55

Water projected by a nozzle against the motor from any direction shall have no harmful effect.

IP56

Motor protected against conditions on a ship'sdeck.

58

We Bring Air to Life

Flkt Woods Group provides a full range of products and solutions for buildings ventilation, air treatment and industrial air movement

Southern Sales Office


Flkt Woods Ltd Unit 6240, Bishops Court Solihull Parkway Birmingham B37 7YB +44 (0)121 717 4680 Tel: Fax: +44 (0)121 717 4699

Northern Sales Office


Flkt Woods Ltd First Floor, Entrance 6, Crossford Court Dane Road, Sale, Cheshire M33 7BZ +44 (0)161 969 1992 Tel: Fax: +44 (0)161 969 4612

Head Office
Flkt Woods Ltd Axial Way Colchester Essex C04 5ZD +44 (0)1206 222 555 Tel: Fax: +44 (0)1206 222 777

Sales Offices available World Wide - See our website for details

www.flaktwoods.com/uk

Due to a policy of continuous development and improvement the right is reserved to supply products which may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order. Copyright, Flkt Woods Ltd, 2006. All rights reserved. No part of this publication may be produced in any material form by any means without the written permission of Flkt Woods Ltd. Any unauthorised use of this data may result in legal proceedings.

FWDD/1006/C18a

Você também pode gostar