NPS-101
1:N Protection Switching Device

Automatic protection switching for E1/T1 and T3 streams

1:N protection switching for Gmux-2000 TDM pseudowire and voice compression modules Traffic protection capacity of up to 224 TDM streams (16 or 8 protected modules) Transparent hardware-only switching Control and monitoring via Gmux-2000

NPS-101 is a compact, high-density carrier-class 1:N protection switching device. It protects the traffic carried by a group of N modules installed in Gmux-2000 by automatically switching traffic from a failed to a backup module in the chassis.

The unit has a capacity of 16 protection switching modules and 2 backup modules, each capable of handling 14 E1/T1 or 1 T3 streams, resulting in a maximum traffic protection capacity of 224 streams.

The Access Company

NPS-101 1:N Protection Switching Device

The following Gmux-2000 modules can be protected: Voice compression modules with E1 or T1 ports, VCA-E1/12, VCA-E1/16 and VCA-T1/12, VCA-T1/16 Pseudowire emulation modules with external E1 or T1 ports, E1-PW/28/BAL, E1-PW/28/UNBAL and T1-PW/28 Pseudowire channelized T3 module, CT3-PW/1.

As a purely hardware switching device, NPS-101 does not detect or evaluate any criteria for protection switching. Gmux-2000 determines when switching is required, and sends appropriate control signals to NPS-101. MANAGEMENT Gmux-2000 communicates with a supervision terminal via double RS-232 port on NPS-101 (DCE and DTE). This allows controlling and monitoring the unit even when Gmux-2000 is managed by one of the other supported management alternatives (Telnet/SSH, SNMP).

WIDE RANGE POWER SUPPLIES NPS-101 uses a wide range power supply, which operates on both AC and DC. The power supply is located together with the NPS-101 common logic functions in a single module. Although a single control/PS module is required, two modules can be installed in the device for redundancy.

When operating opposite voice compression modules, NPS-101 protects either 12/16 external or two main E1/T1 links.

Figure 1. Protecting E1/T1 Traffic

Data Sheet

Specifications
CHASSIS Number of Slots 20: 2 for power supply and common logic modules, PSCL 16 for protection switching modules, NPS-62 2 for backup modules, BU-62 Number of Protection Buses 2, 14 E1/T1, 1 T3 streams capacity each PROTECTION SWITCHING MODULE Capacity 14 E1/T1, 1 T3 Connectors 2 62-pin, D-type, female for incoming and outgoing traffic BACKUP MODULE Capacity 14 E1/T1, 1 T3 Connectors 62-pin, D-type, female for outgoing traffic

GENERAL Management Interface 1 RS-232 DCE 9-pin female, 115.2 kbps 1 RS-232 DTE 9-pin male, 115.5 kbps Indicators Chassis: POWER A, B Chassis power status ALARM System alarm status PCSL module: PWR Module power status ALM Module alarm status NPS-62, BU-62 module: Bus A, Bus B Corresponding bus use Power AC/DC: 100240 VAC, 50/60 Hz or 48/60VDC nominal (40 to 72 VDC) Power Consumption 15W max Physical Height: 178 mm (7.0 in) Width: 482 mm (19.0 in) Depth: 327 mm (12.8 in) Weight: 7.5 kg (16.5 lb) Environment Temperature: 0 to 45C (32 to 113F) Humidity: Up to 90%, non-condensing

Data Sheet
NPS-101 1:N Protection Switching Device

358-108-03/09 Specifications are subject to change without prior notice. 19882009 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.

Ordering
NPS-101/?/* Chassis, module and cable assembly

OPTIONAL ACCESSORIES NPS-101-M/? Spare common logic, protection and backup modules

GMUX-PPANEL-28-PW/# Patch panel and cable assembly, 28 connectors

Legend
? Protected module: CT3 CT3-PW/1 PW E1-PW-28 or T1-PW-28 VC12 VCA-E1/12 or VCA-T1/12 (12 E1/T1) VC16 VCA-E1/16 or VCA-T1/16 (16 E1/T1) VC2 VCA-E1/12, VCA-T1/12, VCA-E1/16 or VCA-T1/16 (2 E1/T1) * Protection scheme: 1 1:1 2 1:2 3 1:3 4 1:4 5 1:5 6 1:6

Legend
# Interface: BAL Balanced interface, RJ-45 UNBAL Unbalanced interface, BNC

Legend
? Spare module: PCSL Power supply and common logic module NPS-62 Protection switching module BU-62 Backup module CBL-TERMINAL-Y-CABLE Y-cable for terminal connection CBL-TERMINAL-X-CABLE X-cable for terminal connection CBL-GMUX-VC12/NPS Adapter cable for connecting VCA-E1/12 or VCA-T1/12 module to BU-62 and NPS-62 modules CBL-GMUX-VC16/NPS Adapter cable for connecting VCA-E1/16 or VCA-T1/16 module to BU-62 and NPS-62 modules CBL-NPS/14 Adapter cable for connecting user equipment to external ports of VCA-E1/12 or VCA-T1/12 modules (via NPS-101) CBL-NPS/18 Adapter cable for connecting user equipment to external ports of VCA-E1/16 or VCA-T1/16 modules (via NPS-101)

CBL-G703-14-PATCH Cable for connecting the NPS-62 module to a patch panel

International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com

North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@rad.com

www.rad.com

Order this publication by Catalog No. 803862

The Access Company

Você também pode gostar