Você está na página 1de 92

Excellence

Passion

Integrity

Responsibility

GEA-versity

GEA Refrigeration Technologies


GEA Bock GmbH
Benzstrae 7, 72636 Frickenhausen, Germany
Phone: +49 7022 9454-0, Fax: +49 7022 9454-137
bock@gea.com, www.bock.de, www.gea.com

GEA Group AG. All rights reserved. 09689-08.2012-Gb, Subject to change wothout notice, Copyright GEA Bock

GEA Group is a global engineering company with multi-billion euro sales and operations in more
than 50 countries. Founded in 1881, the company is one of the largest providers of innovative
equipment and process technology. GEA Group is listed in the STOXX Europe 600 Index.

Bock Compressors for Mobile Applications


Vehicle compressors for bus-, railway air-conditioning and transport refrigeration

engineering for a better world

GEA Refrigeration Technologies

Bock Vehicle Compressors

In touch with our customers

GEA Refrigeration Technologies:


Your partner for low temperatures

Service - Made by GEA Bock

Worldwide, Up-to-Date, Comprehensive GEA Bock on the Internet - www.bock.de


Products
--Comprehensive product brochure

GEA Refrigeration Technologies, part of the internationally active GEA Group, is a syn-

--Data on all products

onym for industrial refrigeration technology. Since the end of the 19th century, it has been

--Dimensions and exploded views

our business to cool processes and products, and to control the temperature of goods in

--Spare parts lists

transport.
You will find our solutions in the food and beverage sector; in the petrochemical, chemical, and pharmaceutical industries; on fishing ships; in natural gas liquefaction; in

Sales network

infrastructure facilities; and in ice factories. We are also at the top with know-how when

--Contact persons in over 60 countries

it comes to refrigeration at leisure facilities. After all, we have been excited about refrige-

--Direct link to your trading partner

ration for decades now. As a result, our staff enthusiastically goes about its development
and production projects to include preventive and remedial maintenance of your refri-

geration systems.

Company

This enthusiasm is highly apparent in the daily work of all companies in our Segment.

--Current company information

Whether its complete systems or individual valves: we have the experience in every sec-

--Company film

tion of our company to optimally design, manufacture, and install refrigeration systems.

--Subsidiaries

And to take full advantage of this experience, we not only carry out development in our

--History

own company: we also manufacture, assemble, and test the core components. A chain is,

--References

2
3
4
5

after all, only as strong as its weakest link: and this also applies equally well to refrigeration technology, cooling processes, and cooling chains.

News

This makes it all the more important that you have a partner in GEA Refrigeration

--Company news

Technologies that has learned to master refrigeration from A to Z. And all of this since

--Product news

1896, when Willem Grasso founded his refrigeration division. From this history of GEA

--Current dates

Refrigeration Technologies, you will profit in the form of technical expertise and top
sector know-how.
But we all live in the present and think about the future. We ponder a future in which

Toolbocks - The Refrigeration App

more and more processes need energy around the world, and fewer natural resources are

--Power Converter

available. As a result, we have taken it as our goal to create solutions that are not only long-

--Length Converter

life and cost-effective, but also energy-saving and environment-protecting. We feel obliga-

--Pressure Converter

ted to sustainability in many respects. Our objective is to produce longlife and material-

--Converter Tube Diameter

saving products over the long run as well as products that use environmentally benign

--Refrigerant Calculator

refrigerants. And we aim to produce efficiently. But our responsibility does not end at

--Location Finder

the factory gate. As a result, we take great pains to ensure that our systems are energy-

--Error Analysis/Troubleshooter

efficient and that they protect the climate. With GEA Refrigeration Technologies, you can
also count on optimal economy: saving energy indeed means reducing money spent for
energy. At the same time, you protect the environment. Thanks to our refrigeration tech-

Wordbock - Translation Tool

nology, your processes will run more economically and more ecologically. To maintain our

--Available as an app and

standard of living and to assure quality of life for future generations as well.

--As an online version on www.bock.de

Our claim of combining economy with saving natural resources is reflected in all components of our company, such as the following: compressors, chillers, heat pumps, ice
machines, fittings and valves, control systems, and many, many more. You can find proof

Know-how

of the above throughout the world. Our international corporate network and above all

--Error analysis tool

our reference projects are spread all over the globe.

--VAP software
--Comprehensive information

2 | www.bock.de

09689-08.2012-Gb Subject to change without notice

09689-08.2012-Gb Subject to change without notice

www.bock.de | 91

Bock Compressors

Characteristics vehicle compressors FK I 1


Vehicle compressors FK for bus- and railway air-conditioning N, K I 2
Vehicle compressors FK for transport refrigeration TK I 3
Characteristics semi-hermetic compressors HG I 4
Semi-hermetic compressors HG for bus- and railway air-conditioning I 5
Semi-hermetic compressors HG for R407C up to 35 bar I 6
Service - Made by GEA Bock I 7

Disclaimer
This brochure has been produced for you with the greatest of care. Nevertheless it
is not possible to rule out mistakes completely. In such cases we cannot assume any
liability. The contents correspond to the status on going to print. Deviations cannot
be ruled out because of the ongoing development process for our products.

09689-08.2012-Gb Subject to change without notice

The details are provided as unbinding general information and cannot substitute detailed, individual consultation. Reprints even only of excerpts only allowed with the
explicit approval of GEA Bock GmbH. GEA Bock GmbH 2012

www.bock.de | 3

GEA Bock - More than a compressor


Over 75 years ago, when the refrigeration and air-conditioning
industry was still in its infancy, our company's founder, Wilhelm
Bock, had a vision: He wanted to build first-class and reliable refrigeration machines. In the following decades Bock developed into
one of the world's leading manufacturers of refrigeration and airconditioning compressors.
As part of GEA Refrigeration Technologies, Bock today offers the
right compressor for every application in the areas of bus-, railway
air-conditioning and transport refrigeration.
Besides the vehicle compressors of the FK-series for classical Diesel
engines, new technologies have moved into GEA Bock's focus. For
example special compressors for the use in hybrid systems.
These electric powered, semi-hermetic compressors offer numerous
advantages for mobile applications. The aluminum version is for
example about 40 % lighter than comparable standard compressors and contributes to the innovative lightweight construction of
vehicles.
Based on the current semi-hermetic program there is now a compressor series available for the use with the refrigerant R407C with
expanded fields of application.
No matter what your application is GEA Bock offers you the ideal
compressor for your individual demand.
Be inspired. By our new products, our established product series
and the entire passion that goes into each of our products.

4 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Compressors

Production Program

Semi-hermetic compressors HG (HA)


The Bock HG (Hermetic Gas-cooled) range of semi-hermetic compressors offers traditional
suction gas-cooled compressor state of the art technology. These compressors of the highest
quality standard excel in their running comfort, easy maintenance, efficiency and reliability. Suitable as standard for conventional or chlorine-free HFC refrigerants.
The HA (Hermetic Air-cooled) range, specially engineered by GEA Bock, is available for
deep-freezing applications, in particular for use with the refrigerants R22 and R404A.
-- Single-stage

-- R410A compressors

-- Two-stage compressors

-- CO2 compressors subcritical

-- ATEX compressors

-- Duplex compressors

-- CO2 compressors transcritcal -- HC compressors

-- Compressor units with receiver

-- R134a compressors

-- Aluminium compressors -- Condenser units air-cooled

-- R407C compressors

-- 2-pole compressors

Vehicle compressors FK
Bock vehicle compressors of the FK range are the result of many years of experience in the
domain of mobile cooling systems.
The unsurpassed light, compact, robust design and wide r.p.m. range are only some of the
outstanding features of this unique product range of two, four and six cylinder compressors.
A wide variety of designs can be tailored to suit individual requirements.
The so-called K version is a special innovation with a unique valve plate system for
maximum requirements in bus and coach air-conditioning systems.
-- Compressors for bus and train air-conditioning
-- Compressors for transport refrigeration and other applications

Open type compressors F


The F model series provides modern open type compressors for separate drive systems
(using V belts or direct couplings). Load transfer through a V pair.
Virtually all drive capacity requirements can be met.
Very compact compressor design, robust and easy to handle. Oil pump lubrication as
standard.
-- Single-stage compressors
-- NH3 compressors
-- Compressor units for direct drive
-- NH3 compressor units for direct drive

09689-08.2012-Gb Subject to change without notice

www.bock.de | 5

The difference is in the detail Characteristics Bock FK


Vehicle compressors
Special features

Bock Vehicle Compressors FK

Open type 2-, 4- and 6-cylinder compressors


in full-aluminium lightweight construction

Special features
Three design variations are available for different areas of application:

--For air-conditioning - the K Design


--For air-conditioning or normal cooling - the N Design
Whether in bus- or railway air-conditioning, transport refrigeration or

--For deep freezing - the TK Design

other applications of mobile cooling - Bock FK compressors are specialists


around the world.

The differences are mostly associated with the valve plate version
which is adapted to each application range where operational safety

--Unsurpassed light and compact design

and efficiency are concerned.

--Highly robust design

Additionally we have different solutions for the flexible adaptation of the

--Wide speed range

compressors to your individual requirements.

--Efficient operating performance

Talk to us. Our competent team will be pleased to advise you.

--Universal application

Low-wearing long-lifed mechanism


--Solid construction and design
--Classic crankshaft construction with hardened surface
--Double-sided roller bearing mounting design for maximum
radial forces

--Aluminium pistons with two-ring assembly


--Aluminium connection rod in divided, screwed design
--Quiet with low vibrations
--Four cylinder construction from 385 cm
--Six cylinder already from 662 cm
--Minimum oscillating mass, connecting rods and pistons made out of
aluminium

--Dynamic mass balance of the whole drive-mechanism


--High volume pressure area to dampen pulsations

Reliable and safe oil supply


--Self-contained lubrication through an internal rotor pump
high performance, independent of rotating direction, compact

--Oil overpressure valve to regulate the oil pressure


--High volume oil sump
--Two sight glasses for checking the oil level (FK40/50),
(FK30 one sight glass)

8 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK

Special features

The K Design
--A special GEA Bock innovation. The unique valve plate system for highest standards - specially developed for bus air-conditioning systems.

--Service valves made out of high quality, impact resistant spring steel.
Extremely robust and reliable, not only at constant variations in speed
and in pressure, but also where there are liquids. The base plate of this
systems is made - of aluminium. The valves are constructed as ringfin packages and are guided loosely. This means that they are neither
exposed to lateral nor torsional powers and thanks to their special
construction they cannot fall into the cylinder area or hit the the piston
head. The no compromise solution for mobile air conditioning.

--Highest safety and efficiency in all areas of application

1
2
3
The N Design

4
--The cost-effective alternative to the K Design.
--The universal valve plate system. Suitable for both air-conditioning
in buses and for other applications. The base plate is designed in
steel. The valve units N and TK design are structed as one-sided fixed
tongue fins which makes them form a simple and cost-effective
construction. In comparison to the K design, the valves are exposed
to lateral and torsional powers, which means that the load carrying
ability decreases in particular in air-conditioning where there is fluctuating speed or liquid influence.

The TK Design
--A special variant for deep freezing.
--Build on the N valve plate basic concept with additional measures to
optimise the charging efficiency at low evaporation temperatures.
The piston heads have suction fin contour grooves, which further reduces the dead space and leads to increased performance in the deepfreeze area.

09689-08.2012-Gb Subject to change without notice

www.bock.de | 9

5
6
7
8

Bock Vehicle Compressors FK

Special features

Integrated oil collection system with a large storage volume


FK30/FK40/FK50:

--Practical drain option through a feely accessible flexible tube


--No dismantling of the clutch necessary

Simply constructed shaft seal


--Tried and tested construction for decades

Example:

--Only one O-ring seal, counter ring designed as the screw-on cover

Shaft seal construction FK40

--With oil washing for cooling and lubricating the whole unit
--Easy to change the shaft seal for maintenance purposes

Integrated oil
collection system
Only one O-ring
seal

Practical drain-option via


freely-accessible flexible tube

Various drive options


--Conical shaft end for safe force transmission and exact installation of the drive elements
--V-belt drive with electromagnetic clutch or flywheel
--Additional drive types on request

10 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK

Special features

Economic performance regulation (option)

Full load operation

Partial load operation

--Blocking of the intake of a cylinder bank with an electromagnetic pilot valve


--Possible residual capacity:
4-cylinder compressor: 50 %

6-cylinder compressor: 66 %/ 33 %

3
4

Variable connection and fixing options

5
6
7
8

Special design, example:


Suction shut-off valve mounted on cylinderbank
with intermediate adapter

Special design, example:


Suction shut-off valve mounted between the cylinder covers

--Variable position of the suction shut-off valve (FK30/40/50)

--More variants for fixing the compressor

--Rotate options for the suction and discharge shut-off valve

--Customer-made designs on request

--Fixing options for supplementary attachments

09689-08.2012-Gb Subject to change without notice

www.bock.de | 11

12 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Vehicle Compressors FK for busand railway air-conditioning N, K


At a glance
Operating limits and performance data
Technical data
Dimensions and connections
Scope of supply and accessories

09689-08.2012-Gb Subject to change without notice

14
15
21
22
28

www.bock.de | 13

Bock Vehicle Compressors FK...N, K

At a glance

Type key

FK X 50 / 980 K
Design 2)
Swept volume
Size
Ester oil filling1)
Series

1)

X - Ester oil filling (HFC refrigerant e.g. R134a, R407C)

2)

K - specially for air-conditioning

N - for air-conditioning or normal cooling

The current program


...4 model sizes with 14 capacity stages from 10,3 to 84,9 m/h (1450 rpm)

FK50

FK40

FK30
FK20

14 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

Operating limits

R134a Operating limits

FKX20 / FKX30 / FKX40 / FKX50

tc (C)

90
82

80

Reduced suction gas temperature

? toh < 20 K

70
60
50
40

-10

10

20

30 to (C)

Max. permissible operating pressure (LP/HP)1): 19/28 bar


1)

Evaporating temperature (C)


Condensing temperature (C)

tOh

30
-20

tO
tC

tOh Suction gas superheat (K)

toh + 25 C

20
-30

Unlimited application range

LP = low pressure HP = high pressure

Suction gas temperature (C)

Permissible rotation speed:


N Design: 500 - 3000 rpm

(max. rotation speed 3500 rpm)

1
2

K Design: 500 - 3500 rpm

3
R134a Notes

Operating limits

Compressor operation is possible within the limits shown on the ap-

plication diagrams. Please note the coloured areas. Compressor appli-

cation limits should not be chosen for design purposes or continuous

operation.

Performance data
Performance specifications for the R134a are based on 25 C suction
gas temperatures without liquid subcooling (FKX50/830 and FKX50/980
on 20 C suction gas temperature). Compressor speed 1450 rpm.
The values can be stated to judge the overall performance at other

Cooling capacity Q0
Power required P

speed with the help of the calculation factors below.


Performance data for other operating points, see GEA Bock software.

09689-08.2012-Gb Subject to change without notice

www.bock.de | 15

Bock Vehicle Compressors FK...N, K

R134a
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30
40

FKX20/120 N
FKX20/120 K

50
60
70
30
40

FKX20/145 N
FKX20/145 K

50
60
70
30
40

FKX20/170 N
FKX20/170 K

50
60
70
30
40

FKX30/235 N
FKX30/235 K

50
60
70
30
40

FKX30/275 N
FKX30/275 K

50
60
70
30
40

FKX30/325 N
FKX30/325 K

50
60
70
30
40

FKX40/390 N
FKX40/390 K

50
60
70

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

15

12,5

10

-5

-10

-15

9827
0,91
8789
1,30
7720
1,65
6629
1,95
5522
2,20
11890
1,10
10635
1,58
9342
2,00
8021
2,36
6681
2,66
14150
1,31
12656
1,87
11117

8983
0,95
8020
1,31
7027
1,63
6012
1,90
4982
2,12
10870
1,15
9704
1,59
8502
1,97
7274
2,30
6029
2,57
12936
1,37
11549
1,89
10118

8194
0,99
7302
1,32
6380
1,60
5438
1,85
4483
2,05
9915
1,20
8835
1,59
7720
1,94
6580
2,23
5425
2,47
11800
1,42
10514
1,90
9188

6771
1,03
6009
1,29
5221
1,52
4415
1,72
3598
1,88
8193
1,24
7271
1,56
6318
1,85
5342
2,08
4353
2,27
9751
1,48
8654
1,86
7519

5540
1,02
4895
1,24
4226
1,42
3540
1,58
2847
1,70
6704
1,24
5923
1,50
5113
1,72
4284
1,91
3445
2,05
7978
1,47
7048
1,78
6085

4484
0,99
3940
1,16
3376
1,31
2798
1,43
2214
1,52
5425
1,20
4768
1,40
4085
1,58
3386
1,73
2679
1,84
6456
1,42
5674
1,67
4861

3584
0,93
3129
1,06
2655
1,18
2170
1,27
1682
1,35
4336
1,12
3786
1,29
3213
1,43
2626
1,54
2035
1,63
5160
1,34
4505
1,53
3823

2823
0,85
2443
0,96
2045
1,05
1639
1,13
1232
1,19
3416
1,03
2956
1,16
2475
1,27
1984
1,37
1491
1,44
4066
1,23
3517
1,38
2945

9545
2,81
7951
3,17
19421
1,79
17370
2,57
15258
3,26
13100
3,86
10912
4,35
23112
2,13
20672
3,06
18158
3,88
15590
4,59
12987
5,17
27125
2,50
24260
3,59
21311
4,56
18297
5,38
15241
6,07
32100
2,96
28711
4,25
25220
5,39
21653
6,37
18037
7,19

8657
2,74
7175
3,06
17754
1,89
15850
2,60
13887
3,22
11881
3,76
9847
4,20
21129
2,24
18863
3,09
16527
3,84
14139
4,47
11718
5,00
24797
2,63
22137
3,63
19396
4,50
16594
5,25
13753
5,87
29345
3,12
26198
4,29
22954
5,33
19638
6,21
16276
6,94

7831
2,66
6456
2,94
16195
1,96
14431
2,60
12610
3,17
10748
3,65
8861
4,04
19273
2,33
17173
3,10
15007
3,77
12791
4,34
10545
4,81
22619
2,73
20155
3,63
17612
4,43
15012
5,10
12376
5,65
26769
3,23
23852
4,30
20842
5,24
17765
6,03
14646
6,68

6357
2,48
5181
2,70
13383
2,03
11877
2,56
10319
3,01
8725
3,40
7110
3,71
15927
2,41
14134
3,04
12280
3,59
10383
4,04
8462
4,41
18692
2,83
16588
3,57
14412
4,21
12186
4,75
9931
5,18
22120
3,35
19631
4,22
17056
4,98
14421
5,62
11752
6,13

5098
2,27
4100
2,44
10949
2,02
9674
2,45
8351
2,81
6997
3,12
5627
3,36
13031
2,41
11513
2,91
9938
3,35
8327
3,71
6697
3,99
15293
2,82
13511
3,42
11664
3,93
9773
4,35
7859
4,69
18098
3,34
15990
4,04
13803
4,65
11565
5,15
9301
5,55

4029
2,05
3189
2,19
8861
1,95
7787
2,29
6672
2,58
5530
2,82
4376
3,00
10545
2,32
9268
2,72
7940
3,07
6581
3,35
5208
3,57
12376
2,73
10877
3,20
9319
3,60
7723
3,94
6112
4,20
14646
3,23
12872
3,78
11028
4,26
9140
4,66
7234
4,96

3125
1,84
2422
1,94
7083
1,84
6183
2,10
5247
2,33
4289
2,52
3324
2,67
8429
2,18
7359
2,50
6244
2,77
5104
3,00
3956
3,17
9892
2,56
8636
2,93
7329
3,25
5990
3,52
4643
3,72
11707
3,03
10221
3,47
8673
3,85
7089
4,16
5494
4,41

2361
1,62
1775
1,72
5580
1,68
4827
1,89
4042
2,07
3240
2,23
2436
2,35
6641
2,00
5745
2,25
4810
2,47
3856
2,65
2899
2,80
7794
2,35
6742
2,64
5646
2,90
4525
3,11
3402
3,29
9223
2,78
7979
3,12
6681
3,43
5355
3,69
4026
3,89

2,38

Relating to 25 C suction gas temperature,


without liquid subcooling

16 | www.bock.de

1.450 rpm

2,35

2,31

2,20

2,05

1,88

1,70

1,51

Reduced suction gas temperature


09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

R134a
Type

Performance data

Performance data
Cond.

Cooling cacapity QO [W]

Power consumption P [kW]

temp.

Evaporating temperature C

C
30
40

FKX40/470 N
FKX40/470 K

50
60
70
30
40

FKX40/560 N
FKX40/560 K

50
60
70
30
40

FKX40/655 N
FKX40/655 K

50
60
70
30
40

FKX50/660 N
FKX50/660 K

50
60
70
30
40

FKX50/775 N
FKX50/775 K

50
60
70
30
40

FKX50/830 N
FKX50/830 K

50
60
70
30
40

FKX50/980 N
FKX50/980 K

50
60
70

1.450 rpm

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

15

12,5

10

38841
3,58
34740
5,15
30516
6,52
26201
7,71
21825
8,70
46224
4,26
41343
6,12
36316
7,77
31181
9,18
25973
10,35
54249
5,01
48521
7,19
42621
9,11
36594
10,77
30483
12,14
55186
5,09
49359
7,31
43357
9,27
37226
10,96
31009
12,35
64767
5,98
57928
8,58
50885
10,88
43689
12,86
36393
14,50
69133
6,40
61668
9,20
53991
11,66
46161
13,78
38235
15,53
81175
7,54
72420
10,80
63408
13,68
54208
16,17
44893
18,24

35508
3,77
31700
5,20
27774
6,45
23762
7,52
19693
8,40
42257
4,49
37725
6,18
33053
7,67
28278
8,95
23437
10,00
49594
5,27
44275
7,26
38792
9,01
33188
10,50
27506
11,73
50450
5,36
45039
7,38
39462
9,16
33761
10,68
27981
11,93
59209
6,29
52859
8,66
46313
10,75
39622
12,54
32838
14,00
63194
6,74
56269
9,29
49141
11,53
41869
13,44
34508
15,01
74192
7,93
66072
10,90
57703
13,52
49158
15,76
40507
17,62

32390
3,91
28861
5,20
25219
6,34
21496
7,30
17721
8,08
38547
4,65
34347
6,19
30013
7,54
25582
8,69
21090
9,62
45239
5,46
40310
7,27
35224
8,85
30023
10,20
24751
11,29
46020
5,56
41006
7,39
35832
9,00
30542
10,37
25179
11,48
54010
6,52
48125
8,68
42053
10,57
35844
12,17
29550
13,48
57636
7,00
51225
9,31
44620
11,34
37879
13,06
31058
14,45
67663
8,21
60145
10,91
52390
13,28
44468
15,30
36451
16,95

Relating to 25C suction gas temperature


(FKX50/830 and FKX50/980 on 20 C suction gas temperature)
without liquid subcooling
09689-08.2012-Gb Subject to change without notice

5
26765
4,05
23753
5,11
20638
6,03
17450
6,80
14220
7,41
31853
4,83
28268
6,08
24561
7,17
20767
8,09
16924
8,82
37383
5,66
33176
7,14
28825
8,42
24372
9,49
19862
10,35
38029
5,76
33749
7,26
29322
8,56
24793
9,66
20205
10,53
44631
6,76
39608
8,52
34413
10,05
29097
11,34
23712
12,36
47606
7,26
42145
9,15
36507
10,79
30749
12,16
24929
13,26
55889
8,51
49486
10,71
42865
12,64
36098
14,25
29256
15,55

0
21899
4,04
19347
4,89
16702
5,63
13994
6,23
11254
6,71
26062
4,81
23025
5,82
19877
6,69
16654
7,42
13393
7,99
30586
5,65
27022
6,83
23328
7,86
19545
8,71
15718
9,37
31114
5,75
27489
6,95
23731
7,99
19883
8,86
15990
9,53
36516
6,74
32261
8,16
27851
9,38
23335
10,40
18766
11,19
38926
7,24
34309
8,76
29533
10,07
24654
11,16
19730
12,01
45709
8,49
40297
10,26
34688
11,80
28953
13,08
23162
14,08

-5

-10

17722
3,91
15575
4,58
13344
5,16
11060
5,64
8753
6,01
21090
4,65
18535
5,45
15880
6,14
13162
6,71
10416
7,15
24752
5,46
21753
6,39
18637
7,21
15447
7,87
12225
8,39
25179
5,55
22129
6,51
18959
7,33
15714
8,01
12436
8,54
29551
6,51
25971
7,63
22251
8,60
18442
9,40
14595
10,02
31477
6,99
27601
8,19
23583
9,23
19479
10,08
15346
10,75
36976
8,20
32433
9,61
27713
10,83
22887
11,83
18025
12,61

14165
3,67
12367
4,20
10494
4,66
8578
5,04
6648
5,33
16858
4,37
14718
5,00
12489
5,54
10208
5,99
7912
6,34
19784
5,13
17273
5,86
14657
6,50
11980
7,04
9285
7,44
20126
5,22
17571
5,96
14910
6,62
12187
7,16
9446
7,57
23620
6,12
20622
7,00
17499
7,76
14303
8,40
11085
8,89
25144
6,57
21904
7,51
18538
8,33
15104
9,01
11658
9,53
29545
7,71
25748
8,82
21794
9,78
17754
10,58
13699
11,19

-15
11160
3,37
9655
3,78
8084
4,15
6479
4,46
4871
4,71
13281
4,00
11490
4,50
9621
4,94
7711
5,31
5797
5,60
15587
4,70
13485
5,28
11291
5,79
9050
6,23
6804
6,58
15856
4,78
13718
5,37
11486
5,89
9206
6,34
6921
6,69
18609
5,61
16099
6,30
13480
6,92
10804
7,44
8123
7,85
19808
6,02
17099
6,76
14282
7,41
11413
7,97
8550
8,42
23272
7,07
20098
7,94
16787
8,71
13411
9,37
10040
9,89

Reduced suction gas temperature

www.bock.de | 17

1
2
3
4
5
6
7
8

Bock Vehicle Compressors FK...N, K

R407C Operating limits

Operating limits

FKX20 / FKX30 / FKX40 / FKX50



Unlimited application range

Reduced suction gas temperature

tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh Suction gas superheat (K)


tOh

Suction gas temperature (C)

Permissible rotation speed:


Max. permissible operating pressure

(LP/HP)1):

19/28 bar

N Design: 500 - 2600 rpm


K Design:: 500 - 3500 rpm

1)

LP = low pressure HP = high pressure

R407C Notes
Operating limits
Compressor operation is possible within the limits shown on the application diagrams. Please note the coloured areas. Compressor application limits should not be chosen for design purposes or continuous
operation.

Performance data
The performance data for R407C are based on 25C suction gas temperatures without liquid subcooling (FKX50/830 and FKX50/980 on 20
C suction gas temperature). Compressor speed 1450 rpm.
The values can be stated to judge the overall performance at other

Cooling capacity Q0
Power required P

speed with the help of the calculation factors below.


Performance data for other operating points, see GEA Bock software.

18 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

R407C
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

FKX20/120 N
FKX20/120 K

40
50
30

FKX20/145 N
FKX20/145 K

40
50
30

FKX20/170 N
FKX20/170 K

40
50
30

FKX30/235 N
FKX30/235 K

40
50
30

FKX30/275 N
FKX30/275 K

40
50
30

FKX30/325 N
FKX30/325 K

40
50
30

FKX40/390 N
FKX40/390 K

40
50
30

FKX40/470 N
FKX40/470 K

40
50
30

FKX40/560 N
FKX40/560 K

40
50
30

FKX40/655 N
FKX40/655 K

40
50

1.450 rpm

15
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

13852
1,37
12393
2,02
10876
2,60
16679
1,64
14923
2,44
13097
3,13
19904
1,96
17808
2,91
15629
3,73
27301
2,69
24426
3,99
21437
5,12
32410
3,20
28998
4,74
25449
6,07
38060
3,75
34052
5,56
29885
7,13
45052
4,44
40309
6,58
35376
8,44
54466
5,37
48732
7,96
42767
10,21
64956
6,41
58117
9,49
51004
12,17
76117
7,50
68103
11,12
59768
14,26

12,5
12688
1,45
11334
2,05
9925
2,57
15278
1,74
13648
2,46
11951
3,09
18232
2,08
16286
2,94
14261
3,68
25007
2,85
22338
4,03
19561
5,06
29687
3,38
26519
4,79
23222
6,00
34863
3,97
31142
5,62
27270
7,05
41268
4,70
36863
6,66
32280
8,35
49891
5,69
44566
8,05
39025
10,09
59500
6,78
53149
9,60
46542
12,03
69723
7,95
62282
11,25
54538
14,10

10
11599
1,51
10344
2,05
9037
2,52
13966
1,81
12455
2,47
10882
3,04
16666
2,17
14863
2,95
12985
3,62
22860
2,97
20386
4,05
17812
4,97
27138
3,52
24202
4,80
21145
5,90
31869
4,14
28420
5,64
24831
6,93
37725
4,90
33642
6,67
29393
8,21
45607
5,92
40672
8,07
35535
9,92
54391
7,06
48505
9,62
42379
11,83
63736
8,28
56839
11,28
49660
13,86

5
9630
1,57
8558
2,02
7442
2,40
11596
1,89
10305
2,43
8961
2,89
13837
2,26
12297
2,90
10693
3,45
18980
3,10
16867
3,98
14667
4,74
22532
3,68
20024
4,72
17412
5,62
26460
4,32
23515
5,55
20447
6,60
31322
5,11
27835
6,57
24204
7,82
37866
6,18
33651
7,94
29262
9,45
45159
7,37
40132
9,47
34897
11,27
52918
8,64
47028
11,10
40893
13,20

0
7922
1,58
7013
1,94
6067
2,25
9540
1,90
8445
2,33
7305
2,71
11384
2,27
10077
2,78
8717
3,23
15614
3,11
13823
3,82
11957
4,43
18536
3,69
16409
4,53
14195
5,26
21768
4,33
19270
5,32
16670
6,17
25767
5,13
22811
6,30
19732
7,31
31151
6,20
27577
7,61
23855
8,83
37151
7,39
32888
9,08
28450
10,54
43534
8,66
38539
10,64
33338
12,35

-5
6452
1,53
5686
1,82
4889
2,07
7769
1,84
6846
2,19
5887
2,49
9271
2,20
8170
2,61
7025
2,97
12716
3,01
11206
3,58
9636
4,07
15096
3,58
13303
4,25
11439
4,84
17728
4,20
15622
4,99
13433
5,68
20985
4,97
18492
5,91
15901
6,72
25369
6,01
22356
7,15
19224
8,13
30256
7,17
26662
8,52
22926
9,69
35454
8,40
31243
9,99
26865
11,36

-10
5195
1,44
4552
1,67
3884
1,88
6256
1,74
5481
2,01
4677
2,26
7465
2,07
6540
2,40
5581
2,70
10240
2,85
8971
3,30
7656
3,70
12156
3,38
10650
3,91
9088
4,39
14275
3,97
12506
4,60
10673
5,15
16898
4,70
14804
5,44
12634
6,10
20429
5,68
17897
6,58
15274
7,38
24363
6,77
21344
7,85
18215
8,80
28549
7,93
25011
9,19
21345
10,31

-15
4129
1,33
3588
1,52
3030
1,69
4972
1,60
4320
1,83
3648
2,03
5933
1,91
5155
2,18
4354
2,42
8138
2,63
7071
2,99
5971
3,32
9661
3,12
8394
3,55
7089
3,94
11345
3,66
9858
4,17
8325
4,63
13430
4,33
11669
4,93
9854
5,48
16236
5,24
14107
5,96
11913
6,63
19363
6,25
16824
7,11
14208
7,90
22690
7,32
19715
8,33
16649
9,26

Relating to 25 C suction gas temperature,


without liquid subcooling

09689-08.2012-Gb Subject to change without notice

www.bock.de | 19

1
2
3
4
5
6
7
8

Bock Vehicle Compressors FK...N, K

R407C
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

FKX50/660 N
FKX50/660 K

40
50
30

FKX50/775 N
FKX50/775 K

40
50
30

FKX50/830 N
FKX50/830 K

40
50
30

FKX50/980 N
FKX50/980 K

40
50

1.450 rpm

15
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

77469
7,64
69312
11,32
60829
14,52
90911
8,97
81339
13,28
71384
17,03
97448
9,61
86978
14,24
76101
18,26
114388
11,30
102124
16,71
89369
21,41

12,5
70961
8,09
63388
11,45
55507
14,35
83275
9,49
74386
13,43
65139
16,84
89219
10,17
79505
14,39
69409
18,05
104740
11,96
93359
16,89
81517
21,17

10
64868
8,43
57849
11,48
50542
14,11
76124
9,88
67887
13,46
59312
16,56
81521
10,59
72526
14,43
63173
17,74
95712
12,44
85170
16,94
74199
20,81

5
53858
8,80
47863
11,29
41620
13,44
63204
10,31
56168
13,25
48842
15,77
67628
11,06
59961
14,20
51984
16,89
79413
12,98
70423
16,66
61062
19,83

-5

44307
8,81
39223
10,83
33930
12,57
51995
10,34
46029
12,71
39818
14,75
55599
11,08
49111
13,62
42362
15,79
65292
13,00
57681
15,98
49759
18,54

36084
8,55
31798
10,16
27342
11,56
42345
10,03
37316
11,93
32087
13,57
45259
10,76
39803
12,78
34133
14,53
53148
12,61
46744
15,00
40090
17,07

-10
29056
8,08
25456
9,36
21724
10,49
34098
9,47
29873
10,98
25494
12,31
36437
10,16
31864
11,77
27126
13,19
42782
11,91
37413
13,81
31854
15,49

-15
23093
7,45
20065
8,48
16945
9,43
27100
8,74
23547
9,95
19885
11,06
28960
9,38
25122
10,67
21168
11,85
33993
11,00
29488
12,52
24852
13,92

Relating to 25C suction gas temperature


(FKX50/830 and FKX50/980 on 20 C suction gas temperature)
without liquid subcooling

20 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

FK

Number
of
cylinders

Technical data

Swept
volume

Displacement
(1450 rpm)

Weight

cm

m/h

118

Connections

Oil charge

Discharge line
DV

Suction line
SV

kg

mm I inch

mm I inch

Ltr.

10,3

15

16 I 5/8

16 I 5/8

0,7

143

12,4

14

16 I 5/8

16 I 5/8

0,7

170

14,8

14

16 I 5/8

16 I 5/8

0,7

233

20,3

25

16 I 5/8

22 I 7/8

2,0

277

24,1

25

22 I 7/8

28 I 1 1/8

2,0

325

28,3

25

22 I 7/8

28 I 1 1/8

2,0

385

33,5

34

22 I 7/8

28 I 1 1/8

2,0

466

40,5

33

28 I 1 1/8

35 I 1 3/8

2,0

554

48,3

33

28 I 1 1/8

35 I 1 3/8

2,0

650

56,6

31

35 I 1 3/8

35 I 1 3/8

2,0

662

57,6

42

35 I 1 3/8

2 x 35 I 1 3/8

2,5

776

67,6

41

35 I 1 3/8

2 x 35 I 1 3/8

2,5

831

72,3

43

35 I 1 3/8

2 x 35 I 1 3/8

2,5

976

84,9

41

35 I 1 3/8

2 x 35 I 1 3/8

2,5

Type
FK20/120 N
FK20/120 K
FK20/145 N
FK20/145 K
FK20/170 N
FK20/170 K
FK30/235 N
FK30/235 K
FK30/275 N
FK30/275 K
FK30/325 N
FK30/325 K
FK40/390 N
FK40/390 K
FK40/470 N
FK40/470 K
FK40/560 N
FK40/560 K
FK40/655 N
FK40/655 K
FK50/660 N
FK50/660 K
FK50/775 N
FK50/775 K
FK50/830 N
FK50/830 K
FK50/980 N
FK50/980 K

For additional technical data see GEA Bock software.

09689-08.2012-Gb Subject to change without notice

7
8

www.bock.de | 21

Bock Vehicle Compressors FK...N, K

Dimensions and connections

FK20/120 K
FK20/120 N

FK20

ca.215
78,5
78,5

73

FK20/145 K
FK20/145 N

ca.263
155

B1

H
30

4x

11
155

60
115

F,G

58

ca.50
99

ca.135

30

130

SV

4x M10x26 LK
110 h8

ca.270 (280)

A2
DV

FK20/170 K
FK20/170 N

3x M10x26
both-sided
beidseitig

125

Dimensions in ( ) = K Design

Shaft end

View X

49
A4x6,5 DIN 6888
M8x22

24,7
34,3
36,3
55,1

Dimensions in mm
Centre of gravity

22 | www.bock.de

1:4

21,69

60
38 -0,05
25

1,5

6x M5

A1

Connections see page 26


09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

Dimensions and connections

FK30/235 K
FK30/235 N

FK30

FK30/275 K
FK30/275 N

FK30/325 K
FK30/325 N

ca.330
296

99/90*

A2

DV
X

12
G
175
200
ca.270/260*

5
50

SV
A1
A
C/E

135

10

45

ca.155

ca.325 (330)
218

SV1

L
B
B1
D/H

K
F/M

4x

97
111

ca.80
130
130

4x M10x21
both-sided
beidseitig

1
2
3
4

* = FK 30 /235
Dimensions in ( ) = K Design

5
6

Shaft end

View X

View Y

Discharge shut-off valve FK30/235

2xM6x14

105

8xM6

60

80

B1 B DV

34

1:5

39
46

30

87

95 f7

1,5

A5x6,5 DIN 6888


M12x28

Leak oil drainSchlauch


hose
Leckl-Ablass

63

Dimensions in mm
Centre of gravity
09689-08.2012-Gb Subject to change without notice

Connections see page 26

www.bock.de | 23

Bock Vehicle Compressors FK...N, K

Dimensions and connections

FK40/390 K
FK40/390 N

FK40

FK40/470 K
FK40/470 N

ca.320 (325)

FK40/560 K
FK40/560 N

FK40/655 K
FK40/655 N

DV B B1
SV1
170

A
A1
C/E
G

M
4x
210
232

13

ca.170
253

SV

4x M10x21 LK

145

ca.370
329

H
K
F

108,5
168,5

ca.50
130
344
ca.385

Dimensions in ( ) = K Design

Shaft end

View Y

8x M8

130

6x M8

72

A5x9 DIN 6888

40

148 h8
110
98
90

M12x28

50
54
66
74
100

Dimensions in mm
Centre of gravity

24 | www.bock.de

1:5

Leak oil drain Schlauch


hose
Leckl-Ablass

Connections see page 26


09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

Dimensions and connections

FK50/660 K
FK50/660 N

FK50

FK50/775 K
FK50/775 N

ca.370 (375)
X

FK50/830 K
FK50/830 N

FK50/980 K
FK50/980 N

356

SV1

SV

D
H
K
F

ca.165

A
A1
G

135

145

ca.335
305

C/E

4x M10x21 LK

210

DV

108,5
133,4

4x 13 M
112,5
112,5
255

ca.115
190
ca.430

82

1
2
3
4
5

Dimensions in ( ) = K Design

6
Shaft end

View X

View Y

7
8

8xM8

130

6xM8

72

A5x9 DIN6888

B1

40

148 h8
110
98
90

M12x28

50
54
66
74
100

Dimensions in mm
Centre of gravity
09689-08.2012-Gb Subject to change without notice

1:5

B
Leak oil drain hose
Leckl-Ablass-Schlauch

Connections see page 26

www.bock.de | 25

Bock Vehicle Compressors FK...N, K

Dimensions and connections

Connections
SV
DV

FK20

Suction line
Discharge line

FK30

FK50

please refer to technical data page 21

Connection suction side,


not lockable

/16 " UNF

A1

Connection suction side,


lockable

/16 " UNF

A2

Connection suction side,


not lockable

/8 " NPTF

Connection suction side,


not loackable

/16 " UNF

B1

Connection discharge side,


lockable

/16 " UNF

Connection oil pressure


safety switch OIL

Connection oil pressure


safety switch LP

Connection
oil pressure gauge

Oil drain

Optional connection
oil sump heater

Oil charge plug

Sight glass

2)

Connection thermal
protection thermostat

3)

Oil filter

Optional connection
suction line valve

SV1

FK40

G 1/8 "

/4 " NPTF

/8 " NPTF

/16 " UNF

/16 " UNF

/8 " NPTF
1

/16 " UNF

/8 " NPTF

/4 " NPTF

/8 " NPTF

M 22 x 1,5

1)

/4 " NPTF

1 1/8 " - 18 UNEF


/8 " NPTF

M 22 x 1,5

/8 " NPTF
/16 " UNF

/16 " UNF

1)

/16 " UNF

/8 " NPTF

/8 " NPTF

/16 " UNF

/8 " NPTF

/8 " NPTF

/8 " NPTF

/4 " NPTF

/16 " UNF

/8 " NPTF
/8 " NPTF
/8 " NPTF
/4 " NPTF

1)

/4 " NPTF

2 x 1 1/8 " - 18 UNEF


1

/8 " NPTF

M 22 x 1,5

1)

/4 " NPTF

2 x 1 1/8 " - 18 UNEF


/8 " NPTF

M 22 x 1,5

Option available
Available on request
1)

No connection available as standard (connection M 22 x 1,5)

2)

Standard is without sight glass (connection M 20 x 1)

3)

No connection available as standard (1/8" NPTF, intermediate flange required)

26 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

Dimensions and connections

FK20 K
FK20 N

Dimensions with accessories

FK30 K
FK30 N

FK40 K
FK40 N

FK50 K
FK50 N

3
1

Capacity regulator

Oil sump heater

5
mm

mm

mm

FK20 N, K

ca. 290

FK30 N, K

ca. 355

FK40 N

ca. 410

ca. 180

FK40 K

ca. 410

ca. 185

FK50 N

ca. 225

ca. 405

FK50 K

ca. 240

ca. 420

Type

09689-08.2012-Gb Subject to change without notice

www.bock.de | 27

Bock Vehicle Compressors FK...N, K

Scope of supply

Scope of supply

FK20

FK30

FK40

FK50

Open type compressor in a light weight alumininium construction,


with suction and discharge valves
Two cylinder, cylinder arrangement in row
Four cylinder, cylinder arrangement in V
Six cylinder, cylinder arrangement in W
Integrated oil collecting system for the shaft seal, hose drain design
Seat front bearing flange
Fastening possibility for electromagnetic clutch
Possible design variants: 1)
K-Design
N Design
Oil charge:
FK: FUCHS Reniso SP 46
FKX: FUCHS Reniso Triton SE 55
One sight glass
Two sight glasses
Decompression valve

2)

Inert gas charge

1)

Only the selected design variant is contained in the scope of supply.

2)

Only for models FK30/275 + 325

The scope of supply is the same for the various levels of displacement and the design variants K and N.
In the data concerning the type of compressor, these additions are not taken into account.

28 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...N, K

Accessories

Accessories

FK20

1 Capacity regulator 24 V DC: 1 capacity regulator = 50 % residual capacity IP65

FK30

FK40

FK50

1)

Capacity regulator 24 V DC: 1-2 capacity regulato = 66/33 % residual capacity IP65 1)
2

Electromagnetic clutch 24 V DC LA 21, 147 mm, 2 x SPA,


Power consumption 48 W 1) 2) 4)
Electromagnetic clutch 24 V DC LA 30.01, 174 mm, 2 x SPA,
Power consumption 51 W 1) 2) 4)
Electromagnetic clutch 24 V DC LA 16.028, 153 mm, 2 x SPB,
Power consumption 60 W 1) 2) 4) bis 775
Electromagnetic clutch 24 V DC LA 26.02, 203 mm, 2 x SPB,
Power consumption 62 W 1) 2) 4) 830 und 980

3 Compressor flywheel (three-spoke, grey cast iron) 165 mm, 2 x SPA


Compressor flywheel (three-spoke, grey cast iron) 210 mm, 2 x SPA
Compressor flywheel (three-spoke, grey cast iron) 210 mm, 3 x SPA

4 Oil sump heater 24 V DC, 40 W IP65 1)

Oil sump heater 24 V DC, 80 W IP65 1)


5 Thermal protection thermostat (bimetal sensor) IP67
6

3)

Intermediate flange for changing the position of the shut-off valves 2)


Oval flange, height 5, 12, 15, 25, 34, 46, 62, 71, 75 oder 95 mm
Sight glass

5)

Other voltages on request


2)
Other designs on request
3)
With intermediate flange
4)
Product by Linnig
5)
Possible just ex works, cannot be retrofitted

The accessories are the same for the various levels of displacement and
the design variants N and K. In the data concerning the type of compressor, these additions are not taken into account.

1)

5
6
7
8

Capacity regulator
1

Electromagnetic clutch
2

Oil sump heater


4

Thermal protection thermostat


5

09689-08.2012-Gb Subject to change without notice

Compressor flywheel
3

Intermediate flange
6

www.bock.de | 29

30 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Vehicle Compressors FK
for transport refrigeration
At a glance
Operating limits and performance data
Technical data
Dimensions and connections
Scope of supply and accessories

09689-08.2012-Gb Subject to change without notice

32
33
36
37
43

www.bock.de | 31

Bock Vehicle Compressors FK...TK

At a glance

Bock vehicle compressors of the FK series are the result of decades

A wide variety of designs can be tailored to suit individual require-

of experience in transport refrigeration.

ments.

The unsurpassed light, compact, robust design and wide

The TK version, optimized for low evaporation temperatures, is a

speed range are only some of the outstanding features of this

special variant for deep freezing.

unique product range of two, four and six cylinder compressors.

Type key

FK X 50 / 775 TK
Design 2)
Swept volume
Size
Ester oil filling 1)

1)

X - Ester oil filling (HFC refrigerant, e.g. R404A, R507)

2)

TK - specially for deep freezing

Series

The current program


...4 model sizes with 12 capacity stages from 10,3 to 67,6 m/h (1450 rpm)

FK50

FK40

FK30
FK20

32 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Operating limits

R404A/R507 Operating limits

FKX20 / FKX30 / FKX40 / FKX50

tc (C)

70

58

60

Reduced suction gas temperature

50

? toh<20K

40

tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh Suction gas superheat (K)

30
20
-50

tOh

toh+20C
-45

-40

-30

-20

-10

Suction gas temperature (C)

10 to (C)

Max. permissible operating pressure (LP/HP)1): 19/28 bar


1)

Unlimited application range

Permissible rotation speed:

TK Design: 500 - 2600 rpm

LP = low pressure HP = high pressure

3
R404A/R507 Notes

Operating limits

Compressor operation is possible within the limits shown on the ap-

plication diagrams. Please note the coloured areas. Compressor appli-

cation limits should not be chosen for design purposes or continuous


operation.

Performance data
The performance data for R404A/R507 are based on 20 C suction gas
temperatures without liquid subcooling.
Compressor speed 1450 rpm.
The values can be stated to judge the overall performance at other
speed with the help of the calculation factors below.

Cooling capacity Q0
Power required P

Performance data for other operating points, see GEA Bock software.

09689-08.2012-Gb Subject to change without notice

www.bock.de | 33

Bock Vehicle Compressors FK...TK

R404A/R507
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

FKX20/120 TK

40
50
30

FKX20/145 TK

40
50
30

FKX20/170 TK

40
50
30

FKX30/235 TK

40
50
30

FKX30/275 TK

40
50
30

FKX30/325 TK

40
50

1.450 rpm

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

-5

9438
2,09
8045
2,39
6620
2,65
11362
2,52
9686
2,88
7970
3,20
13561
3,01
11560
3,44
9513
3,81
20377
3,94
17437
4,66
14498
5,28
24191
4,67
20701
5,53
17212
6,27
28407
5,49
24309
6,50
20212
7,36

7867
2,01
6668
2,25
5443
2,46
9471
2,42
8027
2,71
6552
2,96
11304
2,89
9581
3,24
7820
3,54
17011
3,83
14495
4,41
11985
4,89
20195
4,55
17209
5,24
14229
5,81
23715
5,34
20208
6,15
16709
6,82

-10
6479
1,90
5456
2,09
4414
2,25
7800
2,29
6569
2,52
5314
2,71
9310
2,73
7840
3,01
6343
3,24
14041
3,66
11911
4,11
9791
4,47
16670
4,34
14140
4,88
11624
5,31
19575
5,10
16604
5,73
13649
6,24

-15

-20

-25

5263
1,77
4400
1,92
3524
2,03
6336
2,13
5297
2,31
4243
2,44
7563
2,54
6322
2,75
5064
2,92
11442
3,44
9657
3,77
7889
4,02
13584
4,08
11465
4,48
9366
4,78
15951
4,79
13463
5,26
10998
5,61

4208
1,62
3488
1,72
2762
1,80
5065
1,95
4199
2,07
3326
2,16
6046
2,32
5011
2,48
3969
2,58
9187
3,17
7710
3,40
6254
3,56
10907
3,77
9153
4,04
7425
4,22
12808
4,42
10748
4,74
8719
4,96

3302
1,45
2709
1,52
2117
1,56
3975
1,75
3261
1,83
2549
1,88
4744
2,09
3892
2,19
3043
2,24
7251
2,88
6042
3,01
4860
3,08
8609
3,42
7173
3,57
5769
3,66
10109
4,01
8423
4,20
6775
4,30

-30

-35

2535
1,28
2053
1,31
1579
1,32
3052
1,54
2471
1,58
1900
1,59
3643
1,84
2949
1,89
2268
1,89
5608
2,56
4628
2,61
3680
2,61
6658
3,04
5495
3,10
4369
3,10
7818
3,57
6452
3,64
5130
3,64

1896
1,10
1508
1,10
1135
1,08
2283
1,33
1816
1,33
1366
1,30
2725
1,58
2167
1,59
1631
1,55
4231
2,23
3442
2,21
2690
2,15
5024
2,65
4086
2,63
3193
2,56
5899
3,11
4798
3,09
3750
3,00

Relating to 20 C suction gas temperature,


without liquid subcooling

34 | www.bock.de

Reduced suction
gas temperature

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

R404A/R507
Type

Performance data

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

FKX40/390 TK

40
50
30

FKX40/470 TK

40
50
30

FKX40/560 TK

40
50
30

FKX40/655 TK

40
50
30

FKX50/660 TK

40
50
30

FKX50/775 TK

40
50

1.450 rpm

0
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

31916
6,69
27353
7,67
22482
8,36
38585
8,09
33069
9,27
27179
10,10
46016
9,65
39437
11,06
32414
12,05
54393
11,04
46423
12,90
38345
14,50
54596
10,36
46656
12,25
38303
13,75
63521
12,43
54484
14,72
45112
16,62

Relating to 20 C suction gas temperature,


without liquid subcooling

09689-08.2012-Gb Subject to change without notice

-5
26566
6,39
22603
7,17
18375
7,68
32117
7,73
27326
8,67
22214
9,28
38303
9,22
32588
10,34
26493
11,07
45269
10,70
38384
12,14
31422
13,38
45313
10,13
38444
11,62
31232
12,74
53066
12,15
45085
13,90
36867
15,32

-10
21831
6,00
18421
6,60
14790
6,95
26393
7,25
22270
7,98
17880
8,40
31476
8,65
26559
9,51
21323
10,01
37218
10,14
31328
11,23
25393
12,15
37094
9,68
31210
10,80
25052
11,60
43678
11,58
36703
12,87
29588
13,86

-15

-20

-25

17679
5,53
14775
5,97
11693
6,18
21373
6,68
17862
7,21
14137
7,47
25490
7,97
21302
8,60
16859
8,91
30176
9,41
25192
10,19
20194
10,86
29883
9,04
24897
9,85
19707
10,35
35333
10,78
29311
11,66
23247
12,30

14078
5,00
11632
5,30
9054
5,40
17019
6,04
14063
6,41
10946
6,53
20297
7,21
16771
7,65
13054
7,78
24081
8,55
19913
9,09
15762
9,57
23622
8,26
19447
8,78
15137
9,04
28005
9,81
22884
10,35
17820
10,70

10994
4,43
8961
4,62
6839
4,62
13292
5,36
10834
5,59
8268
5,59
15851
6,39
12920
6,67
9860
6,67
18869
7,62
15427
7,96
12033
8,30
18251
7,36
14801
7,64
11286
7,70
21669
8,71
17397
8,98
13282
9,11

-30
8397
3,85
6729
3,95
5016
3,88
10151
4,66
8135
4,78
6064
4,69
12106
5,55
9702
5,70
7232
5,59
14477
6,66
11671
6,86
8945
7,12
13713
6,40
10902
6,47
8094
6,36
16298
7,54
12824
7,60
9606
7,58

-35
6252
3,28
4903
3,30
3553
3,18
7559
3,96
5928
4,00
4295
3,85
9015
4,72
7070
4,76
5123
4,59
10842
5,71
8582
5,84
6433
6,07
9951
5,39
7691
5,31
5504
5,06
11867
6,37
9141
6,29
6767
6,17

Reduced suction
gas temperature

www.bock.de | 35

1
2
3
4
5
6
7
8

Bock Vehicle Compressors FK...TK

FK

Number
of
cylinders

Technical data

Swept
volume

Displacement
(1450 rpm)

Weight

cm

m/h

kg

Connections

Oil charge

Discharge line
DV

Suction line
SV

mm I inch

mm I inch

Type
5/8

16 I

Ltr.

5/8

0,7
0,7

FK20/120 TK

118

10,3

15

16 I

FK20/145 TK

143

12,4

14

16 I 5/8

16 I 5/8

FK20/170 TK

170

14,8

14

16 I 5/8

16 I 5/8

0,7

22 I 7/8

2,0
2,0

5/

FK30/235 TK

233

20,3

25

16 I

FK30/275 TK

277

24,1

25

22 I 7/8

28 I 1 1/8

7/8

1/8

2,0
2,0

28 I 1

FK30/325 TK

325

28,3

25

22 I

FK40/390 TK

385

33,5

34

22 I 7/8

28 I 1 1/8

FK40/470 TK

466

40,5

33

28 I 1 1/8

35 I 1 3/8

2,0

1/8

35 I 1 3/8

2,0

35 I 1 3/8

2,0

3/
8
3/8

2,5

FK40/560 TK

554

48,3

33

28 I 1

FK40/655 TK

650

56,6

31

35 I 1 3/8
3/

FK50/660 TK

662

57,6

42

35 I 1

2 x 35 I 1

FK50/775 TK

776

67,6

41

35 I 1 3/8

2 x 35 I 1

2,5

For additional technical data see GEA Bock software.

36 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Dimensions and connections

FK20

FK20/120 TK

ca.215
78,5
78,5

73

FK20/145 TK

FK20/170 TK

ca.263
155

B1

A2
H

4x

11
155

58

ca.50
99

ca.135

115

F,G

60

4x M10x26 LK
110 h8

30

30

130

SV

ca.270

DV

3x M10x26
both-sided
beidseitig

125

1
2
3
4
5
6

Shaft end

View X

8
49
A4x6,5 DIN 6888
M8x22

24,7
34,3
36,3
55,1

Dimensions in mm
Centre of gravity
09689-08.2012-Gb Subject to change without notice

1:4

21,69

60
38 -0,05
25

1,5

6x M5

A1

Connections see page 41

www.bock.de | 37

Bock Vehicle Compressors FK...TK

Dimensions and connections

FK30

FK30/235 TK

FK30/275 TK

FK30/325 TK

ca.330
296

99/90*

A2

DV
X

12
G
175
200
ca.270/260*

5
50

SV
A1
A
C/E

135

10

45

ca.155

ca.325
218

SV1

L
B
B1
D/H

K
F/M

4x

97
111

ca.80
130
130

4x M10x21
both-sided
beidseitig

* = FK 30 /235

Shaft end

View X
2xM6x14
8xM6

View Y

105
60

B1 B DV

34
39
46

1:5

30

80

M12x28

87

95 f7

1,5

A5x6,5 DIN 6888

Leak oil drain hose


Leckl-Ablass
Schlauch

63

Dimensions in mm
Centre of gravity

38 | www.bock.de

Connections see page 41


09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Dimensions and connections

FK40

FK40/390 TK

FK40/470 TK

ca.320

FK40/560 TK

FK40/655 TK

DV B B1
SV1
170

A
A1
C/E
G

M
4x
210
232

13

ca.170
253

SV

4x M10x21 LK

145

ca.370
329

H
K
F

108,5
168,5

1
2

ca.50
130

344
ca.385

4
5
6

Shaft end

View Y

8
8x M8

130

6x M8

72

A5x9 DIN 6888

40

148 h8
110
98
90

M12x28

50
54
66
74
100

Dimensions in mm
Centre of gravity
09689-08.2012-Gb Subject to change without notice

1:5

Leak oil drainSchlauch


hose
Leckl-Ablass

Connections see page 41

www.bock.de | 39

Bock Vehicle Compressors FK...TK

Dimensions and connections

FK50

FK50/660 TK

ca.370
X

FK50/775 TK

356

SV1

SV

D
H
K
F

ca.165

A
A1
G

135

145

ca.335
305

C/E

4x M10x21 LK

210

DV

108,5
133,4

4x 13 M
112,5
112,5
255

Shaft end

ca.115
190
ca.430

View X

8xM8

82

View Y

130

6xM8

72

A5x9 DIN6888

B1

40

148 h8
110
98
90

M12x28

50
54
66
74
100

Dimensions in mm
Centre of gravity

40 | www.bock.de

1:5

B
Leak oil drain hose
Leckl-Ablass-Schlauch

Connections see page 41


09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Dimensions and connections

Connections
SV
DV

FK20

Suction line
Discharge line

FK30

FK50

please refer to technical data page 36

Connection suction side,


not lockable

/16 " UNF

A1

Connection suction side,


lockable

/16 " UNF

A2

Connection suction side,


not lockable

/8 " NPTF

Connection suction side,


not loackable

/16 " UNF

B1

Connection discharge side,


lockable

/16 " UNF

Connection oil pressure


safety switch OIL

Connection oil pressure


safety switch LP

Connection
oil pressure gauge

Oil drain

Optional connection
oil sump heater

Oil charge plug

Sight glass

2)

Connection thermal
protection thermostat

3)

Oil filter

Optional connection
suction line valve

SV1

FK40

G 1/8 "

/4 " NPTF

/8 " NPTF

/16 " UNF

/16 " UNF

/8 " NPTF
1

/16 " UNF

/8 " NPTF

/4 " NPTF

/8 " NPTF

M 22 x 1,5

/4 " NPTF

1 1/8 " - 18 UNEF


/8 " NPTF

M 22 x 1,5

/16 " UNF


-

/8 " NPTF

/16 " UNF

/8 " NPTF

/8 " NPTF

/8 " NPTF

/4 " NPTF

1)

/8 " NPTF

/16 " UNF

1)

/16 " UNF

/8 " NPTF
/16 " UNF

/8 " NPTF
/8 " NPTF
/8 " NPTF
/4 " NPTF

1)

1)

/4 " NPTF

/4 " NPTF

/8 " NPTF

M 22 x 1,5

2 x 1 1/8 " - 18 UNEF


/8 " NPTF

M 22 x 1,5

Option available
Available on request
1)

No connection available as standard (connection M 22 x 1,5)

2)

Standard is without sight glass (connection M 20 x 1)

3)

No connection available as standard (1/8" NPTF, intermediate flange required)

09689-08.2012-Gb Subject to change without notice

2
3
4
5

2 x 1 1/8 " - 18 UNEF


1

www.bock.de | 41

6
7
8

Bock Vehicle Compressors FK...TK

Dimensions and connections

Dimensions with accessories

FK20 TK

FK30 TK

FK40 TK

FK50 TK

Capacity regulator

Typ

Oil sump heater

mm

mm

mm

FK20 TK

ca. 290

FK30 TK

ca. 355

FK40 TK

ca. 410

ca. 180

FK50 TK

ca. 225

ca. 405

42 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Scope of supply

Scope of supply

FK20

FK30

FK40

FK50

Open type compressor in a light alumininium construction,


with suction and discharge valves
Two cylinder, cylinder arrangement in row
Four cylinder, cylinder arrangement in V
Six cylinder, cylinder arrangement in W
Integrated oil collecting system for the shaft seal, hose drain design
Seat front bearing flange
Fastening possibility for electromagnetic clutch
Oil charge:
FK: FUCHS Reniso SP 46
FKX: FUCHS Reniso Triton SE 55

One sight glass


Two sight glasses
Decompression valve

1)

Inert gas charge


1)

Only for models FK30/275 + 325

The scope of supply is the same for the various levels of displacement.
In the data concerning the type of compressor, these additions are not taken into account.

6
7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 43

Bock Vehicle Compressors FK...TK

Accessories

Accessories

FK20

FK30

FK40

FK50

1 Capacity regulator 24 V DC, 8 W: 1 capacity regulator = 50 % residual capacity IP65 1)


Capacity regulator 24 V DC, 8 W: 1-2 capacity regulator = 66 / 33 % residual capacity IP65 1)
2

Electromagnetic clutch 24 V DC LA 21, 147 mm, 2 x SPA,


Power consumption 48 W 1) 2) 4)
Electromagnetic clutch 24 V DC LA 30,01, 174 mm, 2 x SPA,
Power consumption 51 W 1) 2) 4)
Electromagnetic clutch 24 V DC LA 16.028, 153 mm, 2 x SPB,
Power consumption 60 W 1) 2) 4) to 775

3 Compressor flywheel (three-spoke, grey cast iron) 165 mm, 2 x SPA


Compressor flywheel (three-spoke, grey cast iron) 210 mm, 2 x SPA
Compressor flywheel (three-spoke, grey cast iron) 210 mm, 3 x SPA
4 Oil sump heater 24 V DC, 40 W IP65 1)
Oil sump heater 24 V DC, 80 W IP65 1)
5 Thermal protection thermostat (bimetal sensor) IP67
6

3)

Intermediate flange for changing the position of the shut-off valves 2)


Oval flange, height 5, 12, 15, 25, 34, 46, 62, 71, 75 oder 95 mm
Sight glass

5)

Other voltages on request


Other designs on request
3)
With intermediate flange
4)
Product by Linnig
5)
Possible just ex works, cannot be retrofitted

1)

2)

The accessories are the same for the various levels of displacement.
In the data concerning the type of compressor, these additions are not taken into account.

44 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors FK...TK

Capacity regulator
1

Electromagnetic clutch
2

Oil sump heater


4

Thermal protection thermostat


5

Accessories

Compressor flywheel
3

Intermediate flange
6

1
2
3
4
5
6
7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 45

The difference is in the detail Characteristics semi-hermetic


Bock compressors
Special features
MP10 Motor Protection
Frequency converter technology
ESS Electronic Soft Start
ESP Electronic Single Phase
e-series
Aluminium compressors
2-pole compressors

48
51
52
53
54
56
57
58

Semi-hermetic Compressors HG

Special features

Universal
--e.g. R134a, R404A, R507, R407C, R22

Economic capacity control

One compressor design for all standard refrigerants.

--Cylinder cover incorporating a connection for capacity control

For air-conditioning applications, normal refrigeration and deep-freezing

--Possible control stages:

--Maximum allowed operating pressure (HP): 28 ba

High refrigeration capacity combined with minimum


power requirement

4 cylinder: 50 %

Minimum space requirement


Particularly low installation height and width

--Optimized gas flow


--Efficient service valves

Quiet and low vibration

--Minimum clearance volume

--Generously dimensioned crank mechanism

--Powerful, economic drive motors

--Optimized mass balance


--Large volume pressure section for pulsation absorption

Stable valve plate design

--4 cylinder design from as little as 18,8 m/h at 50 Hz

--Universally proven valve design with intake and discharge finger reed
valves clamped on one side

--Valve made of high quality impact-resistant spring steel

Replaceable motors
The compressors can be repaired in the field as the drive motor can be
exchanged. (Not for 2-pole aluminium compressors).

Safe, reliable oil supply

Wear-resistant durable driving gear

--Conventional lubricating system incorporating an oil pump

--Solid construction and design

--Large volume oil sump

--Low friction sleeve bearings


--Aluminium pistons with two ring assembly

48 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Special features

Solid construction and design

Replaceable motors

--Valve design, tried and trusted all over the world, with onesided

The compressors can be repaired directly on-site, since the

fixed finger reed, suction and pressure side

--Valve made of high quality impact-resistant spring steel

motors are replaceable.


Only for grey cast iron housings and 4-pole aluminium compressors!

1
2

Variable suction line valve position

Oil sump heater (option)

3
4
5
6
7
8

--Shut-off valves rotatable through 90

--Installed in the housing bore

--Flexible location for suction line and discharge line connection

--PTC heater, self-regulating


--Replacement without opening the refrigeration circuit

Economic capacity control (option)

Full load operation

Partial load operation

--Locking of suction port of a cylinder bank with an electromagnetic pilot valve


--Possible residual capacity:
4-cylinder compressor: 50 %
09689-08.2012-Gb Subject to change without notice

www.bock.de | 49

Semi-hermetic Compressors HG

Special features

Electric switch box

--Robust aluminium construction


--Easy electrical installation due to large internal volume
--Terminal block with cables in glass seal model
--Hinged and removable lifting cover 1

with a single quick fastener 2

--Terminal strip for add-on components


--Protection system: IP66

Electric switch box with reduced height (option)


--Terminal box with reduced height (-15 mm)
--Motor protection MP10 as an extra item for control cabinet installation

50 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

MP10 Motor Protection

MP10
Motor Protection
Temperature safety drive for the drive motor
Standard in all compressors
The exceptional feature is that the monitoring function and mains
availability are shown by coloured LED's. There are no complicated or
time-consuming defect locating processes.

Technical data
Unit designation

MP10

Connection voltage

AC 230 V - 1 - 50/60 Hz

Relay

AC 250 V, 3 A, 750 VA ind.

Dimensions L/W/H

100 x 60 x 52 mm

The MP10 also provides the usual functions as standard, e.g. a reconnection preventing device, a reset, free terminals for PTC temperature
sensors (e.g. heat protection thermostat) and other useful items.

1
2
3
4
5
6
7
Green LED
Mains supply
available

Supply section
Cable connections
with screwless terminals

Red LED
Temperature fault in motor

Drive section
Cable connections with
screwless terminals

Red LED
Temperature fault (random e.g.
heat protection thermostat)

09689-08.2012-Gb Subject to change without notice

www.bock.de | 51

Semi-hermetic Compressors HG

Frequency converter technology

Continuously variable speed control using


frequency converter technology
Continuously variable speed control using frequency converter technolo-

The advantages of frequency-converter operation:

gy is the most efficient means of adapting the capacity of the compressor

--Fully variable adjustment of the refrigerating capacity on demand

to current refrigeration plant requirements.

--No high-energy, high-wear start/stop operation


--25 % or more energy saving potential!

Thanks to the oil pump lubrication all Bock compressors are ideal for

--Reduced mechanical compressor load for longer service life

speed control, in particular for low frequencies.

--Always optimum machine pressures and operating conditions


--Lower pressure losses in the heat exchangers
--Lower cooling down and heating up losses throughout the system
--Reduced start-up current at full torque
--Part windings and star-delta circuits no longer required

Start-up current with and without EFC/EFCe

COP behaviour with EFC/EFC

Direct start
Y/ start
Soft start
EFC/EFCe start-up

Frequency (Hz)

Engine performance factor

with and without EFC/EFCe


Start/stop behaviour with and without EFC/EFCe
without EFC/EFCe
with EFC/EFCe
stop time without EFC/EFCe

without EFC/EFCe
with EFC/EFCe

Calulations for 4-pole compressors


Calculating the maximum possible frequency of the
compressor under specific operating conditions:

Calculating the corresponding refrigerating capacity:

The following calculation is used to obtain the maximum


possible frequency at the selected operating point:

Refrigeration capacity can be determined as a function of


frequency from the following calculation:
.
.
fBetrieb x Q0 50 Hz
Q0 Betrieb =

50 Hz

fmax =

Pmax x 50 Hz
Pe

fmax = Maximum permissible frequency [Hz]


Pmax = Maximum power consumption [kW] (see technical data)
Pe = Power consumption at the operating point at 50 Hz [kW]

(see performance data, compressors)

.
Q0 operation = Refrigerating capacity at the chosen
operating point [W]
f. operation = Frequency at the chosen operating point [Hz]
Q0 50 Hz = Refrigerating capacity at the operating point at Hz [W]
(see performance data, compressors)

As a rule, the maximum permissible power consumption of the compressor Pmax must not be exceeded.

52 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

ESS Electronic Soft Start

ESS System
Electronic Soft Start
The advantages:

Electronic compressor starter unit

--Soft compressor start from zero to nominal speed, time controlled and

Available as option for:


HG22e, HG34e, HG34P

monitored.

--Up to 40 % lower start-up power consumption than when using

The start process uses an electronic soft start unit, instead of the conventional start unloader through the bypass solenoid valve, non-return valve

star-delta start

--No star-delta protection combination needed, no bypass between


pressure and suction side needed. No solenoid valve or non-

and star-delta protector combination. This means that the compressor


gets up to its nominal speed in a set time and therefore produces much
lower power peaks than the classical star-delta start.
The unit is designed to fit into a switch cabinet.

return valve needed

-- No compressor damage resulting from malfunction of the start unloader.

Dimensions

1
2
3

Scope of supply:

--Unit suitable for fitting into a switch cabinet

--Voltage AC 400 V - 3 - 50/60 Hz

--Control voltage AC 230V - 1 - 50/60 Hzz

7
8

Technical data
Unit designation
ESS 25
ESS 38
ESS 63
1)

Protection

IP 20
Connectors
IP00

Max.
output current 1)

Input

25 A
38 A
63 A

AC 400 V -3- 50/60 Hz

Lost heat

Dimensions
a/b/c

8W

125 x 45 x 150

19 W

125 x 45 x 150

12 W

160 x 55 x 170

at +50 C ambient temperature

09689-08.2012-Gb Subject to change without notice

www.bock.de | 53

Semi-hermetic Compressors HG

ESP Electronic Single Phase

ESP System
Electronic Single Phase
Phase converter from single to three phase AC
Available as an option for HG12P
The ESP System consists of a phase converter and a power choke to limit

The unit is intended for use in switching cabinets.

the power. This unit converts single phase input power to three pha-

Another option is the continuous variable speed control.

se output power and therefore enables the compressor model HG12P

The accessories for this are a suction pressure transducer and a program-

to operate with a standard three phase AC motor using a single phase

ming and readout hand-held terminal.

mains supply. The unit is designed to be fitted into a switch cabinet.

For the compressors HGX12P/90-4 S and HGX12P/110-4

with R404A please note:


tO = -5 C / tC = +50 C may not be exceeded.

Single-phase current

Power choke
Input
single-phase
alternating current
Phase converter

Output
three-phase
alternating current

54 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

ESP Electronic Single Phase

ESP System Electronic Single Phase


The advantages:

Technical data

--Standard three phase AC compressor can be used on a single phase

Unit designation ESP 1/3 - 2,2

supply

consisting of: phase converter and power choke

--Soft compressor start from zero to nominal speed, time controlled and
monitored

--Up to 40 % lower start-up power consumption than using star


delta-start

--No start-up or operating condensers or relays required

Power choke:
Protection

IP 20

Power consumption

AC 230/240 V - 1 - 50/60 Hz 18 A

--Contact free switching of main phases, no switch protection needed


--Option available for continuous variable speed control

Phase converter:
Protection

IP 20

Max. output current under


continuous load

9,5 A

Max. output power

2,2 kW

Input

AC 230/240 V - 1 - 50/60 Hz

Output

AC 230/240 V - 3 - 50/60 Hz

Permissable control range


(compressor)*

30 - 60 Hz

5
6

* Only for extension to continuous variable speed control

7
Dimensions

8
Power choke

90

150

Phase converter

60

80

240

100

Dimensions in mm

Scope of supply:

Accessories: (possible just ex works, cannot be retrofitted)

--ESP 1/3 - 2,2, comprising phase converter, programmed and tuned to

Extension of function to continuous variable speed control 30-60 Hz

the compressor and also a power choke to control the power. Both

comprising:

units are intended for use in switching cabinets.

--Suction pressure transducer 4-20 mA

--Input: Single phase AC 230/240 V

--Programming and readout hand-held terminal

--Output: Three phase AC 230/240 V


09689-08.2012-Gb Subject to change without notice

www.bock.de | 55

Semi-hermetic Compressors HG

e-series

e-series
efficiency-optimized version
Based on our current semi-hermetic product range, with its outstanding advantages and features, GEA Bock presents you the eseries. Those compressors are efficiency optimised models for all
standard refrigerants.
All compressors of the HG series will gradually be available as
e-series.

Special features
With technical optimisations we improve the energy consumption
of our compressors continuously. The compressors of the e-series
set a new standard when it comes to motor-efficiency, gas flow and
efficiency of the valve system. All this results in a higher capacity
of the compressor.

Optimised
valve plate system

Optimised
gas flow

56 | www.bock.de

Available models

Displacement

50 Hz (1.450 rpm)

HG22e/125-4
HG22e/125-4 S

11,1 m/h

HG22e/160-4
HG22e/160-4 S

13,7 m/h

HG22e/190-4
HG22e/190-4 S

16,5 m/h

HG34e/215-4
HG34e/215-4 S

18,8 m/h

HG34e/255-4
HG34e/255-4 S

22,1 m/h

HG34e/315-4
HG34e/315-4 S

27,3 m/h

HG34e/380-4
HG34e/380-4 S

33,1 m/h

New, flow-optimised
connections

Highly efficient
motors

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Aluminium compressors

Powerful lightweights
semi-hermetic compressors for mobile applications
With the two models HG22 and HG34 in full-aluminium, light-

For especially power-intensive applications, such as mobile air-con-

weight construction, GEA Bock offers the perfect solution for all

ditioning, GEA Bock also offers the Pluscom model HG34P in 2-pole

application areas in which the weight of the compressor is impor-

design.

tant.
The 2-pole drive motor generates a rotational speed of
2900 rpm (in comparison, 4-pole 1450 rpm) and so a high
refrigeration capacity never before achieved in this size.
The HG34P in 2-pole design is available both in grey cast iron and
in the above-mentioned aluminium lightweight design and reduced height terminal box.

1
2
3
4
5
6

Whether used in railway- or bus air-conditioning or transportation


refrigeration these compressors, which are around 40% lighter

than standard compressors, offer system manufacturers new possibilities. Moreover, the compressors are available with a terminal

box with reduced height, to be even more compact than the standard version.

09689-08.2012-Gb Subject to change without notice

www.bock.de | 57

Semi-hermetic Compressors HG

2-pole compressors

Semi-hermetic compressors
with 2-pole drive motor
Based on our compressors of the Pluscom series with its outstanding advantages and features, GEA Bock offers already for some
time a compressor version with 2-pole drive. This compressor version now offers a mains frequency of 60 Hz and thus an increased
refrigeration capacity compared to the operation with 50 Hz mains
frequency.
This increase in the maximum possible compressor capacity can
be realized through the use of a special valve plate system. The socalled Bock K-valve plate, which was developed by GEA Bock especially for mobile applications, is already used thousands of times in
the area of bus air-conditioning and sets the international standard
for quality and reliability.

Available
models

Displacement Displacement
50 Hz (2900 rpm)

60 Hz (3480 rpm)

HGX34P/255-2
HGX34P/255-2 A

44,3 m/h

HGX34P/315-2
HGX34P/315-2 A
HGX34P/315-2 S
HGX34P/315-2 S A

54,7 m/h

HGX34P/315-2 A K
HGX34P/315-2 S A K

54,7 m/h

65,6 m/h

HGX34P/380-2
HGX34P/380-2 A

66,1 m/h

HGX34P/380-2 A K

66,1 m/h

79,4 m/h

Shall the compressor without a frequency converter operate at


a power supply frequency of 50 Hz, the adaptation of the mains
frequency is necessary.
e.g. 400 V / 50 Hz
460 V / 60 Hz

58 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

2-pole compressors

Special features
--High performance with 2-pole drive motor (up to 3480 rpm)
--With oil pump lubrication as standard
--Bock K-valve plate
--Also available in aluminium lightweight design (option)
(ca. 40% weight savings)
--Available with terminal box with reduced height

The K Design for 50 Hz and 60 Hz

2900 rpm

3480 rpm

K Design
50 Hz

60 Hz

N Design

The N Design for 50 Hz

1
2
3
4
5
--The Bock K-valve plate with ringfins
for higher loads

--Valve design, tried and trusted all over the world, with one-sided
fixed finger reed valves, suction and pressure side

--Valve made out of high quality, impact resistant spring steel

6
7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 59

Semi-hermetic Compressors for


railway- and bus air-conditioning
At a glance
Operating limits and performance data
Technical data
Dimensions and connections
Scope of supply and accessories

62
64
71
73
78

Semi-hermetic Compressors HG

At a glance

Semi-hermetic 2- and 4-cylinder compressors


in cast iron and full-aluminium construction
The Bock semi-hermetic compressor programme for mobile applications provides a full performance range of innovative and modern compressor designs in 2- and 4-cylinder constructions.
The ideal solution for any kind of mobile application.

Type key

HG X 3 4 P / 215 - 2 S A K
Version
Aluminium version
Motor variant 5)
Number of poles 4)
Swept volume
e-series / Pluscom 3)
Number of cylinders
Size
Ester oil filling
Series 1)

2)

1)
2)

HG = Hermetic Gas-cooled (suction gas-cooled)


X

= Ester oil filling (HFC refrigerant e.g. R134a, R407C)

3)

= Additional indication for e-series and Pluscom compressors

4)

= 2-poles (2.900 rpm - 50 Hz)

= 4-poles (1.450 rpm - 50 Hz)

5) S

= More powerful motor e.g. air-conditioning systems

6) K

= K valve plate

62 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

At a glance

The current program


...3 model sizes with 14 capacity stages
from 5,4 to 33,1 (1450 rpm) and 44,3 to 66,1 m/h (2900 rpm)

HG34

1
2

HG34

3
4

HG22

5
6

HG12

7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 63

Semi-hermetic Compressors HG

Operating limits

R134a Operating limits

HGX12P / HGX22e / HGX34e / HGX34P 2-pole

Unlimited application range


4-pole

Supplementary cooling or
reduced suction gas temperature
Motor variant -S(more powerful motor)

2-pole

Max. permissible operating pressure (LP/HP)1): 19/28 bar


1)

LP = low pressure HP = high pressure

Unlimited application range

tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh Suction gas superheat (K)


tOh

Suction gas temperature (C)

R134a Notes
Operating limits

Performance data

Compressor operation is possible within the limits shown on the ap-

The performance data for R134a are based on EN 12900 at 50 Hz

plication diagrams. Please note the coloured areas. Compressor appli-

supply frequency. This signifies 20 C suction gas temperature without

cation limits should not be chosen for design purposes or continuous

liquid subcooling.

operation.
This results in significant differences compared to specifications with
Restrictions to the operating limits may occur when using a frequency

liquid undercooling and/or suction gas temperatures.

converter. For further information see sample calculation page 52.


4-pole compressor:
For operation with frequency converter:

Conversion factor for 60 Hz = 1,2

HGX12P...-4 30-70 Hz
HGX22e...-4 30-70 Hz

Performance data for other operating points, see GEA Bock software.

HGX34e...-4 25-70 Hz
HGX34P...-2 15-50 Hz
HGX34P...-2 K 15-60 Hz

64 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Performance data

R134a
Type

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30
40

HGX12P/60-4 S

50
60
70
30
40

HGX12P/75-4
HGX12P/75-4 S

50
60
70
30
40

HGX12P/90-4
HGX12P/90-4 S

50
60
70
30
40

HGX12P/110-4
HGX12P/110-4 S

50
60
70
30

HGX22e/125-4
HGX22e/125-4 S
HGX22e/125-4 A
HGX22e/125-4 S A

40
50
60
70
30

HGX22e/160-4
HGX22e/160-4 S
HGX22e/160-4 A
HGX22e/160-4 S A

40
50
60
70

50 Hz 4-pole

12,5
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

4920
0,70
4260
0,85
3630
0,99
3020
1,11
2450
1,22
6150
0,88
5320
1,06
4530
1,23
3780
1,39
3070
1,53
7300
1,08
6380
1,33
5490
1,59
4620
1,82
3780
2,00
8619
1,23
7453
1,49
6342
1,74
5287
1,96
4291
2,15
10200
1,30
8990
1,69
7800
2,02
6570
2,27
5330
2,48
12800
1,63
11200
2,07
9640
2,46
8230
2,80
6880
3,09

Relating to 20 C suction gas temperature,


without liquid subcooling

09689-08.2012-Gb Subject to change without notice

10

7,5

4490
0,71
3880
0,84
3300
0,97
2740
1,08
2220
1,17
5610
0,89
4850
1,05
4120
1,21
3430
1,35
2780
1,46
6670
1,10
5820
1,33
4990
1,56
4180
1,77
3410
1,93
7858
1,24
6787
1,48
5767
1,70
4800
1,89
3888
2,06
9270
1,35
8200
1,70
7090
1,98
5950
2,21
4800
2,38
11600
1,65
10200
2,05
8760
2,41
7460
2,72
6210
2,97

4080
0,71
3520
0,83
2990
0,94
2480
1,04
2010
1,12
5100
0,89
4400
1,03
3730
1,17
3100
1,30
2510
1,40
6070
1,12
5290
1,32
4520
1,53
3780
1,71
3060
1,84
7145
1,25
6163
1,45
5229
1,65
4344
1,82
3511
1,96
8440
1,38
7450
1,69
6420
1,94
5360
2,13
4310
2,27
10600
1,66
9200
2,03
7930
2,36
6730
2,63
5580
2,85

5
3700
0,71
3190
0,81
2700
0,91
2240
1,00
1810
1,06
4620
0,88
3980
1,01
3380
1,14
2800
1,24
2260
1,33
5520
1,12
4790
1,30
4080
1,48
3400
1,65
2750
1,76
6477
1,24
5580
1,42
4726
1,60
3919
1,75
3159
1,87
7660
1,39
6740
1,67
5780
1,88
4810
2,04
3840
2,16
9560
1,65
8330
2,00
7170
2,29
6060
2,54
4990
2,72

0
3010
0,68
2590
0,77
2190
0,85
1800
0,91
1450
0,96
3760
0,85
3230
0,96
2730
1,05
2250
1,13
1800
1,19
4510
1,10
3890
1,24
3290
1,38
2720
1,51
2180
1,58
5272
1,20
4528
1,35
3820
1,48
3152
1,60
2524
1,68
6220
1,39
5440
1,59
4630
1,75
3810
1,86
3000
1,93
7780
1,63
6750
1,92
5780
2,15
4840
2,33
3930
2,45

-5
2420
0,65
2070 1
0,71
1740
0,77
1420
0,82
1130
0,85
3020
0,81
2590
0,89
2170
0,97
1780
1,02
1410
1,06
3630
1,06
3110
1,16
2610
1,26
2140
1,35
1690
1,40
4231
1,13
3619
1,25
3037
1,36
2486
1,44
1969
1,49
4960
1,34
4300
1,48
3620
1,59
2940
1,66
2280
1,70
6240
1,59
5390
1,81
4580
1,99
3790
2,11
3000
2,17

-10

-15

-20

1910
0,60
630
0,65
1350
0,70
1100
0,74
847
0,75
2390
0,75
2030
0,82
1690
0,88
1370
0,92
1060
0,94
2870
1,00
2440
1,06
2030
1,14
1640
1,20
1280
1,22
3342
1,05
2842
1,14
2364
1,23
1910
1,29
1483
1,31
3860
1,25
3310
1,35
2750
1,41
2200
1,45
1690
1,47
4920
1,51
4230
1,68
3560
1,80
2880
1,87
2190
1,87

1480
0,54
1250
0,59
1030
0,63
806
0,66
602
0,66
1850
0,68
1560
0,74
1280
0,79
1010
0,82
751
0,83
2230
0,92
1880
0,96
1540
1,01
1230
1,05
937
1,05
2593
0,95
2183
1,04
1789
1,11
1411
1,15
1053
1,16
2930
1,14
2480
1,20
2020
1,24
1590
1,25
1200
1,25
3810
1,41
3240
1,53
2680
1,60
2100
1,61
1490
1,56

1130
836
0,49
0,44
932
670
0,54
0,49
742
505
0,57
0,52
558
341
0,59
0,55
381
0,60
1410
1050
0,61
0,55
1170
837
0,67
0,61
927
630
0,71
0,65
697
425
0,74
0,68
476
0,74
1700
1260
0,83
0,74
1410
1020
0,85
0,74
1130
793
0,89
0,77
876
592
0,91
0,79
653
0,90
1971
1464
0,86
0,78
1631
1173
0,94
0,85
1299
883
1,00
0,92
977
596
1,04
0,96
667
1,04
2160
1550
1,02
0,891
1790
1260
1,05
0,903
1440
978
1,06
0,908
1110
744
1,07
0,909
829
1,06
2870
2110
1,29
1,15
2410
1730
1,36
1,17
1940
1310
1,38
1,14
1430
844
1,34
1,04
862
1,23

-25

-30
605
0,40
456
0,45
302
0,49
146
0,52

756
0,50
569
0,57
377
0,62
182
0,65

912
0,65
708
0,65
522
0,67
359
0,69

1060
0,71
797
0,79
528
0,87
255
0,91

1090
0,765
860
0,769
657
0,773
504
0,783

1490
0,983
1160
0,962
783
0,884
335
0,744

Supplementary cooling or
reduced suction gas temp.

www.bock.de | 65

1
2
3
4
5
6
7
8

Semi-hermetic Compressors HG

Performance data

R134a
Type

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

HGX22e/190-4
HGX22e190-4 S
HGX22e/190-4 A
HGX22e/190-4 S A

40
50
60
70
30

HGX34e/215-4
HGX34e/215-4 S
HGX34e/215-4 A
HGX34e/215-4 S A

40
50
60
70
30

HGX34e/255-4
HGX34e/255-4 S
HGX34e/255-4 A
HGX34e/255-4 S A

40
50
60
70
30

HGX34e/315-4
HGX34e/315-4 S
HGX34e/315-4 A
HGX34e/315-4 S A

40
50
60
70
30

HGX34e/380-4
HGX34e/380-4 S
HGX34e/380-4 A
HGX34e/380-4 S A

40
50
60
70

12,5
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

15300
2,04
13600
2,62
11900
3,09
10100
3,54
8280
3,91
17200
2,27
15200
2,87
13000
3,38
10800
3,79
8590
4,12
20600
2,61
18100
3,36
15600
4,02
13100
4,56
10500
4,98
25500
3,40
22300
4,22
19200
4,97
16100
5,63
13100
6,18
30700
4,27
27000
5,26
23200
6,17
19600
6,97
16000
7,65

Relating to 20 C suction gas temperature,


without liquid subcooling

66 | www.bock.de

50 Hz 4-pole

10

7,5

14000
2,06
12500
2,55
10800
3,01
9160
3,41
7510
3,74
15700
2,30
13800
2,84
11800
3,27
9690
3,62
7680
3,89
18800
2,67
16500
3,35
14200
3,93
11900
4,41
9430
4,77
23300
3,43
20300
4,17
17400
4,85
14600
5,44
11800
5,91
28100
4,28
24600
5,19
21200
6,01
17800
6,73
14500
7,31

12900
2,06
11400
2,51
9840
2,92
8320
3,28
6790
3,57
14400
2,32
12600
2,78
10700
3,16
8690
3,45
6830
3,66
17200
2,71
15000
3,31
12900
3,83
10700
4,24
8480
4,54
21100
3,43
18500
4,10
15800
4,71
13100
5,22
10600
5,62
25600
4,26
22400
5,09
19300
5,83
16100
6,46
13100
6,97

5
11700
2,05
10400
2,46
8940
2,83
7520
3,14
6110
3,39
13000
2,31
11400
2,72
9540
3,03
7750
3,27
6040
3,43
15600
2,71
13600
3,25
11600
3,71
9610
4,06
7590
4,30
19200
3,40
16700
4,01
14200
4,55
11800
5,00
9390
5,33
23200
4,22
20300
4,97
17400
5,63
14600
6,18
11800
6,60

-5

-10

-15

-20

-25

-30

9630
2,00
8460
2,33
7270
2,62
6070
2,86
4880
3,03
10600
2,25
9120
2,55
7590
2,76
6070
2,90
4630
2,99
12700
2,66
11000
3,08
9310
3,42
7640
3,66
5970
3,79
15500
3,29
13500
3,78
11400
4,19
9350
4,51
7380
4,71
19000
4,06
16600
4,67
14100
5,18
11700
5,59
9340
5,86

7800
1,92
6810
2,17
5800
2,39
4800
2,56
3810
2,68
8450
2,14
7190
2,34
5890
2,47
4620
2,54
3440
2,56
10100
2,53
8660
2,84
7280
3,08
5920
3,23
4570
3,28
12400
3,11
10700
3,49
8950
3,79
7280
4,00
5660
4,08
15300
3,83
13300
4,30
11300
4,69
9240
4,96
7290
5,09

6180
1,80
5360
1,98
4520
2,14
3700
2,26
2900
2,32
6590
1,98
5530
2,11
4440
2,18
3400
2,20
2480
2,17
7800
2,34
6660
2,57
5540
2,73
4450
2,80
3380
2,76
9660
2,88
8260
3,16
6880
3,36
5520
3,46
4200
3,44
12100
3,53
10400
3,89
8760
4,16
7130
4,31
5530
4,32

4790
1,65
4110
1,78
3430
1,89
2770
1,96
2150
1,97
5000
1,80
4120
1,87
3240
1,90
2420
1,89
1730
1,84
5890
2,12
4960
2,27
4070
2,36
3220
2,37
2410
2,28
7390
2,61
6260
2,80
5140
2,91
4050
2,93
3000
2,82
9310
3,20
8000
3,46
6670
3,62
5350
3,66
4040
3,56

3610
1,48
3060
1,57
2520
1,63
2010
1,66
1540
1,64
3670
1,59
2970
1,64
2270
1,64
1660
1,61
1190
1,56
4320
1,88
3570
1,97
2880
2,01
2240
1,96
1660
1,83
5520
2,32
4620
2,43
3720
2,47
2850
2,41
2010
2,22
7060
2,83
6020
3,00
4940
3,07
3860
3,02
2800
2,83

2640
1,29
2200
1,34
1790
1,37
1410
1,37

1870
1,09
1530
1,11
1220
1,12
959
1,10

2610
1,38
2060
1,42
1540
1,42
1120
1,39

1800
1,18
1400
1,22
1040
1,24
784
1,24

3080
1,63
2490
1,68
1960
1,68
1510
1,61

2190
1,41
1710
1,43
1330
1,41
1030
1,32

4040
2,02
3320
2,07
2600
2,04
1900
1,92

2920
1,72
2330
1,73
1740
1,65
1170
1,47

5250
2,46
4420
2,56
3540
2,55
2650
2,42

3860
2,09
3180
2,13
2450
2,06
1690
1,86

Supplementary cooling or
reduced suction gas temp.

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Performance data

R134a
Type

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30
40

HGX34P/255-2
HGX34P/255-2 A

50
60
70
30

HGX34P/315-2
HGX34P/315-2 A
HGX34P/315-2 A K

40
50
60
70
30

HGX34P/380-2
HGX34P/380-2 A
HGX34P/380-2 A K

40
50
60
70

50 Hz 2-pole

15
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

39699
8,45
35067
9,53
30304
10,40
25473
11,05
20632
11,46
49386
8,65
43240
10,52
37096
12,03
30994
13,20
24974
14,04
54230
13,28
48142
14,18
41930
15,17
35602
16,15
29169
16,99

10

7,5

32887
7,93
28934
8,81
24875
9,49
20771
9,97
16682
10,22
40993
8,62
35838
10,14
30698
11,34
25612
12,23
20620
12,83
45243
12,00
40109
12,89
34842
13,79
29450
14,61
23944
15,23

29809
7,64
26166
8,43
22429
9,03
18659
9,42
14916
9,61
37189
8,51
32488
9,87
27807
10,92
23187
11,69
18667
12,18
41160
11,41
36453
12,28
31607
13,12
26632
13,85
21538
14,34

26941
7,35
23588
8,05
20153
8,56
16696
8,88
13279
9,00
33638
8,34
29362
9,55
25113
10,47
20930
11,12
16854
11,51
37338
10,86
33023
11,68
28565
12,46
23973
13,08
19257
13,44

-5

21802
6,72
18969
7,25
16077
7,62
13188
7,80
10362
7,79
27263
7,86
23754
8,79
20284
9,47
16893
9,91
13620
10,14
30436
9,81
26803
10,54
23018
11,15
19091
11,53
15030
11,57

-10

-15

17406
13692
6,06
5,39
15013
11659
6,45
5,65
12585
9615
6,68
5,76
10184
7622
6,74
5,72
7869
6,63
21812
17227
7,24
6,52
18957
14914
7,92
6,99
16154
12665
8,39
7,28
13441
10519
8,66
7,41
10860
8,75
24457
19322
8,83
7,88
21371
16647
9,42
8,28
18124
13801
9,81
8,42
14724
10794
9,91
8,19
11182
9,60

10598
4,73
8846
4,86
7106
4,87

13450
5,75
11567
6,04
9760
6,19

14952
6,92
12551
7,09
9971
6,93

60 Hz 2-pole

Power consumption P [kW]

Performance data

Cond.

Cooling capacity QO [W]

temp.

Evaporation temperature C

C
30
40
50
60
70
30
40

HGX34P/380-2 A K

R134a

HGX34P/315-2 A K

Type

50
60
70

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

15

10

7,5

55162
10,43
48298
12,69
41435
14,51
34619
15,91
27895
16,93
60573
16,02
53773
17,10
46834
18,30
39766
19,47
32581
20,49

45788
10,39
40030
12,23
34289
13,67
28607
14,75
23031
15,47
50535
14,47
44801
15,54
38917
16,63
32895
17,62
26745
18,37

41539
10,26
36288
11,90
31060
13,17 1
25899
14,09
20850
14,69
45975
13,77
40717
14,81
35304
15,83
29748
16,70
24057
17,29

37572
10,06
32797
11,51
28050
2,62
23379
13,41
18825
13,89
41705
13,09
36885
14,09
31906
15,03
26777
15,78
21510
16,20

30452
9,48
26533
10,60
22657
11,42
18869
11,95
15213
12,23
33996
11,83
29938
12,71
25711
13,45
21324
13,90
16788
13,95

-5
24363
8,73
21175
9,55
18043
10,12
15014
10,44
12130
10,55
27318
10,65
23871
11,36
20243
11,83
16446
11,95
12490
11,57

-10

-15

19242
7,86
16659
8,43
14146
8,78
11750
8,94

15024
6,93
12920
7,29
10902
7,47

21582
9,50
18594
9,98
15415
10,15
12056
9,88

16701
8,34
14020
8,55
11137
8,36

Relating to 20 C suction gas temperature,


without liquid subcooling

09689-08.2012-Gb Subject to change without notice

www.bock.de | 67

Semi-hermetic Compressors HG

Operating limits

R407C Operating limits

HGX12P / HGX22e / HGX34e / HGX34P 2-pole

tc (C)
70
61

Unlimited application range

60

50

4-pole

Supplementary cooling or
reduced suction gas temperature

Motor variant -S(more powerful motor)

? tOh<20K

40
30

2-pole

tOh+20C

20
-30

-25

-20

-10

-5

10

12,5

20 to (C)

Max. permissible operating pressure (LP/HP)1): 19/28 bar


1)

LP = low pressure HP = high pressure

Unlimited application range

1 HGX34P/380-2 HGX34P/380-2 A HGX34P/380-2 A K


Please note operating limits
tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh Suction gas superheat (K)


tOh

Suction gas temperature (C)

R407C Notes
Operating limits

Performance data

Compressor operation is possible within the limits shown on the

The performance data R407C are based on EN 12900 to 50 Hz supply

application diagrams. Please note the coloured areas. Compressor

frequency. This signifies 20 C suction gas temperature without liquid

application limits should not be chosen for design purposes or

subcooling.

continuous operation.

The evaporating- and condensing temperautres are based on the dew


point values (saturated vapour conditions).

Restrictions to the operating limits may occur when using a frequency converter. For further information see sample calculation

This results in significant differences compared to specifications with

page 52.

liquid undercooling and/or suction gas temperatures.

For operation with frequency converter:

4-pole compressor:

HGX12P...-4 30-70 Hz

Conversion factor for 60 Hz = 1,2

HGX22e...-4 30-70 Hz
HGX34e...-4 25-70 Hz

Performance data for other operating points, see GEA Bock software.

HGX34P...-2 15-50 Hz
HGX34P...-2 K 15-60 Hz

68 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Performance data

R407C
Type

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

HGX12P/60-4 S

40
50
30

HGX12P/75-4
HGX12P/75-4 S

40
50
30

HGX12P/90-4
HGX12P/90-4 S

40
50
30

HGX12P/110-4
HGX12P/110-4 S

40
50

HGX22e/125-4
HGX22e/125-4 S
HGX22e/125-4 A
HGX22e/125-4 S A

30

HGX22e/160-4
HGX22e/160-4 S
HGX22e/160-4 A
HGX22e/160-4 S A

30

HGX22e/190-4
HGX22e/190-4 S
HGX22e/190-4 A
HGX22e/190-4 S A

30

HGX34e/215-4
HGX34e/215-4 S
HGX34e/215-4 A
HGX34e/215-4 S A

30

HGX34e/255-4
HGX34e/255-4 S
HGX34e/255-4 A
HGX34e/255-4 S A

30

HGX34e/315-4
HGX34e/315-4 S
HGX34e/315-4 A
HGX34e/315-4 S A

30

HGX34e/380-4
HGX34e/380-4 S
HGX34e/380-4 A
HGX34e/380-4 S A

30

40
50

40
50

40
50

40
50

40
50

40
50

40
50

50 Hz 4-pole

Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

12,5

10

6780
0,88
5870
1,16
5010
1,41
8740
1,12
7560
1,50
6450
1,82
10500
1,34
9020
1,79
7690
2,17
12300
1,58
10600
2,10
9040
2,56
14400
1,78
12500
2,36
10700
2,87
17600
2,18
15200
2,90
12900
3,53
21800
2,67
18900
3,54
16100
4,31
25600
3,45
22400
4,38
19100
5,19
29600
4,30
26000
5,33
22200
6,25
35900
4,95
31300
6,32
26800
7,63
43500
6,40
8000
7,95
32200
9,52

6180
0,90
5340
1,16
4550
1,39
7960
1,16
6880
1,49
5860
1,79
9490
1,38
8200
1,78
6990
2,13
11200
1,62
9640
2,10
8210
2,51
13100
1,82
11400
2,35
9640
2,81
16000
2,24
13800
2,90
11700
3,46
19900
2,74
17200
3,54
14600
4,23
23300
3,49
20300
4,33
17300
5,06
27000
4,30
23600
5,24
20200
6,08
32700
5,00
28500
6,25
24300
7,45
39600
6,35
34600
7,78
29300
9,23

Relating to 20 C suction gas temperature,


without liquid subcooling

09689-08.2012-Gb Subject to change without notice

7,5
5610
0,92
4840
1,15
4120
1,35
7230
1,18
6240
1,48
5310
1,74
8620
1,40
7440
1,77
6330
2,08
10200
1,65
8750
2,08
7440
2,45
11900
1,85
10300
2,33
8740
2,75
14500
2,28
12500
2,87
10700
3,38
18100
2,79
15600
3,51
13300
4,13
21100
3,50
18400
4,26
15600
4,91
24600
4,28
21500
5,13
18300
5,89
29800
5,01
25900
6,16
22100
7,24
36000
6,27
31400
7,59
26500
8,92

5
5080
0,92
4380
1,13
3720
1,31
6550
1,18
5650
1,46
4800
1,69
7810
1,41
6730
1,74
5720
2,02
9180
1,66
7910
2,05
6730
2,38
10800
1,87
9300
2,30
7910
2,67
13200
2,30
11300
2,83
9590
3,28
16400
2,81
14100
3,46
12000
4,01
19100
3,48
16600
4,17
14100
4,75
22300
4,23
19500
5,00
16500
5,69
27000
4,99
23500
6,04
20000
7,02
32700
6,17
28400
7,39
24000
8,60

0
4140
0,91
3560
1,08
3020
1,22
5340
1,17
4590
1,39
3890
1,58
6360
1,40
5470
1,66
4640
1,88
7480
1,64
6430
1,95
5460
2,21
8790
1,85
7560
2,19
6410
2,48
10700
2,27
9180
2,69
7780
3,05
13300
2,78
11500
3,29
9700
3,73
15600
3,39
13400
3,94
11300
4,39
18300
4,08
15800
4,71
13400
5,25
22100
4,86
19200
5,72
16200
6,50
26700
5,93
23200
6,94
19600
7,93

-5
3330
0,88
2860
1,01
2420
1,12
4300
1,13
3690
1,30
3120
1,44
5120
1,34
4400
1,55
3720
1,72
6020
1,58
5170
1,82
4370
2,02
7070
1,78
6060
2,04
5120
2,27
8730
2,30
7500
2,64
6350
2,93
10800
2,83
9220
3,25
7790
3,60
12200
3,16
10400
3,60
8590
3,98
14500
3,84
12300
4,38
10200
4,83
17600
4,69
15100
5,33
12800
5,87
21600
5,84
18700
6,71
15800
7,49

Motor version -S(more powerful motor)

-10
2650
0,82
2270
0,92
1920
1,00
3420
1,06
2920
1,19
2470
1,29
4080
1,26
3490
1,42
2940
1,55
4790
1,48
4100
1,67
3460
1,82
5630
1,67
4800
1,87
4050
2,04
6950
2,16
5950
2,42
5020
2,64
8550
2,65
7310
2,97
6170
3,24
9720
2,94
8190
3,25
6820
3,54
11500
3,54
9730
3,94
8080
4,29
14100
4,34
12000
4,85
10200
5,25
17500
5,38
15100
6,08
12800
6,69

-15
2080
0,76
1780
0,83
1490
0,90
2680
0,98
2290
1,07
1920
1,15
3200
1,16
2730
1,28
2290
1,37
3760
1,37
3200
1,50
2690
1,61
4420
1,53
3760
1,68
3150
1,81
5470
1,99
4650
2,18
3900
2,34
6700
2,44
5710
2,68
4810
2,87
7650
2,67
6410
2,89
5330
3,09
9040
3,20
7660
3,50
6420
3,76
11100
3,96
9420
4,33
7910
4,63
13900
4,91
12000
5,45
10100
5,91

-20
1610
0,69
1360
0,74
1130
0,79
2080
0,89
1760
0,96
1460
1,01
2480
1,05
2090
1,13
1740
1,21
2910
1,24
2460
1,33
2040
1,42
3420
1,39
2890
1,5
2400
1,59
4240
1,79
3580
1,94
2970
2,06
5180
2,20
4390
2,38
3650
2,53
5910
2,38
4920
2,52
4100
2,66
7030
2,85
5940
3,06
5050
3,26
8590
3,55
7260
3,80
6060
3,99
10900
4,42
9320
4,82
7900
5,13

-25
1230
0,62
1020
0,66
827
0,69
1580
0,79
1320
0,84
1070
0,89
1890
0,95
1570
1,00
1280
1,06
2220
1,11
1850
1,18
1500
1,25
2600
1,25
2160
1,32
1760
1,40
3230
1,61
2680
1,72
2180
1,81
3960
1,98
3290
2,10
2670
2,22
4480
2,09
3700
2,17
3100
2,27
5300
2,48
4430
2,63
3820
2,79
6550
3,11
5500
3,27
4550
3,37
8310
3,90
7140
4,18
6070
4,36

Supplementary cooling or
reduced suction gas temp.

www.bock.de | 69

1
2
3
4
5
6
7
8

Semi-hermetic Compressors HG

Performance data

R407C
Type

Performance data
Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30

HGX34P/255-2

40

HGX34P/255-2 A

50
60
30

HGX34P/315-2 S
HGX34P/315-2 S A
HGX34P/315-2 S A K

40
50
60
30

HGX34P/380-2
HGX34P/380-2 A
HGX34P/380-2 A K

40
50
60

12,5
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

10

7,5

52539
47952
12,07
11,48
46183
42128
13,17
12,57
39689
36164
14,42
13,77
32997
29998
15,72
14,97
63241
57821
13,80
13,29
55904
51037
15,40
14,85
48302
44007
17,11
16,48
40621
36918
18,81
18,04
74227
68198
19,29
18,40
65658
60233
21,04
20,07
56631
51863
22,97
21,88

R407C
Type

43691
10,94
38356
12,01
32877
13,15
27193
14,23
52726
12,79
46464
14,30
39976
15,83
33448
17,25
62453
17,54
55067
19,12
47330
20,81
39256
22,31

0
32658
9,54
28523
10,46
24235
11,29
19733
11,93
39278
11,40
34404
12,68
29362
13,84
24339
14,75
46946
15,07
41150
16,38
35163
17,68
29001
18,68

-5

-10

26551
21247
8,71
7,90
22996
18095
9,45
8,39
19281
14778
10,01
8,61
15346
10,27
31740
25246
10,50
9,59
27642
21804
11,57
10,40
23414
18271
12,42
10,89
19243
12,92
38072
30389
13,53
12,08
33212
26367
14,65
13,01
28269
22369
15,69
13,77
23257
16,34

30
40
50
60
30
40
50
60

-15
16579
7,05
13654
7,23

19713
8,65
16806
9,14

23916
10,73
20634
11,45

60 Hz 2-pole

Cond.

Cooling capacity QO [W]

Power consumption P [kW]


Evaporation temperature C

HGX34P/380-2 A K

5
39736
10,44
34845
11,48
29807
12,53
24561
13,48
47944
12,32
42175
13,76
36199
15,18
30202
16,44
56995
16,70
50164
18,19
43034
19,75
35622
21,08

Performance data
temp.

HGX34P/315-2 S A K

50 Hz 2-pole

12,5
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

10

70638
64585
16,65
16,03
62443
57007
18,58
17,91
53952
49155
20,64
19,87
45373
41236
22,68
21,76
82909
76175
23,26
22,20
73338
67278
25,38
24,21
63255
57929
27,71
26,40

7,5
58893
15,43
51899
17,25
44652
19,10
37360
20,81
69758
21,16
61509
23,07
52866
25,10
43848
26,91

5
53551
14,86
47108
16,60
40433
18,32
33735
19,83
63661
20,14
56031
21,94
48067
23,82
39789
25,43

0
43872
13,75
38429
15,30
32797
16,70
27185
17,79
52438
18,18
45964
19,76
39276
21,33
32393
22,53

-5
35452
12,66
30875
13,96
26153
14,98
21494
15,59
42525
16,32
37097
17,68
31575
18,92
25978
19,71

-10

-15

28199
11,57
24354
12,55
20408
13,14

22018
10,43
18772
11,03

33943
14,57
29451
15,69
24986
16,61

26714
12,94
23048
13,82

Relating to 20 C suction gas temperature,


without liquid subcooling

70 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

HG
HG Alu

Number Displacement
of
50 / 60 Hz Voltage
cylinders (1450/1740 rpm)

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

5,40 / 6,40
6,70 / 8,10
6,70 / 8,10
8,00 / 9,60
8,00 / 9,60
9,40 / 11,30
9,40 / 11,30
11,10 / 13,30
11,10 / 13,30
11,10 / 13,30
11,10 / 13,30
13,70 / 16,40
13,70 / 16,40
13,70 / 16,40
13,70 / 16,40
16,50 / 19,80
16,50 / 19,80
16,50 / 19,80
16,50 / 19,80
18,80 / 22,60
18,80 / 22,60
18,80 / 22,60
18,80 / 22,60
22,10 / 26,60
22,10 / 26,60
22,10 / 26,60
22,10 / 26,60
27,30 / 32,80
27,30 / 32,80
27,30 / 32,80
27,30 / 32,80
33,10 / 39,70
33,10 / 39,70
33,10 / 39,70
33,10 / 39,70

Electrical data

Weight

Max.
power consumption
2

Starting
current

Max.
working
current
2

kW

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

A
/ Y
6,8 / 3,9
7,1 / 4,1
8,0 / 4,6
8,5 / 4,9
8,8 / 5,1
9,2 / 5,3
10,6 / 6,1
9,3 / 5,4
9,3 / 5,4
10,8 / 6,2
10,8 / 6,2
11,1 / 6,4
11,1 / 6,4
13,1 / 7,6
13,1 / 7,6
13,8 / 8,0
13,8 / 8,0
16,2 / 9,4
16,2 / 9,4
14,0 / 8,1
14,0 / 8,1
18,3 / 10,5
18,3 / 10,5
17,0 / 9,8
17,0 / 9,8
21,1 / 12,2
21,1 / 12,2
21,1 / 12,2
21,1 / 12,2
25,5 / 14,7
25,5 / 14,7
26,1 / 15,1
26,1 / 15,1
31,2 / 18,0
31,2 / 18,0

A
/ Y
40 / 23
40 / 23
43 / 25
43 / 25
45 / 26
43 / 25
45 / 26
69 / 40
69 / 40
69 / 40
69 / 40
69 / 40
69 / 40
87 / 50
87 / 50
69 / 40
69 / 40
87 / 50
87 / 50
87 / 50
87 / 50
132 / 76
132 / 76
87 / 50
87 / 50
132 / 76
132 / 76
111 / 64
111 / 64
132 / 76
132 / 76
111 / 64
111 / 64
132 / 76
132 / 76

m/h

Type
HG12P/60-4 S
HG12P/75-4
HG12P/75-4 S
HG12P/90-4
HG12P/90-4 S
HG12P/110-4
HG12P/110-4 S
HG22e/125-4
HG22e/125-4 A
HG22e/125-4 S
HG22e/125-4 S A
HG22e/160-4
HG22e/160-4 A
HG22e/160-4 S
HG22e/160-4 S A
HG22e/190-4
HG22e/190-4 A
HG22e/190-4 S
HG22e/190-4 S A
HG34e/215-4
HG34e/215-4 A
HG34e/215-4 S
HG34e/215-4 S A
HG34e/255-4
HG34e/255-4 A
HG34e/255-4 S
HG34e/255-4 S A
HG34e/315-4
HG34e/315-4 A
HG34e/315-4 S
HG34e/315-4 S A
HG34e/380-4
HG34e/380-4 A
HG34e/380-4 S
HG34e/380-4 S A

Technical data

2,2
2,3
2,6
2,8
2,9
3,1
3,6
3,0
3,0
3,6
3,6
3,7
3,7
4,4
4,4
4,8
4,8
5,6
5,6
4,8
4,8
6,0
6,0
6,0
6,0
7,2
7,2
7,4
7,4
8,9
8,9
9,3
9,3
11,1
11,1

Connections 4

Oil
charge

Discharge
line
DV

Suction
line
SV

kg

mm I inch

mm I inch

Ltr.

48,0
48,0
49,0
49,0
49,0
49,0
49,0
74,0
44,0
74,0
46,0
74,0
46,0
76,0
47,0
74,0
45,0
75,0
47,0
92,0
55,0
97,0
58,0
92,0
55,0
96,0
58,0
94,0
57,0
97,0
60,0
93,0
56,0
96,0
59,0

12 I 1/2
12 I 1/2
12 I 1/2
12 I 1/2
12 I 1/2
12 I 1/2
12 I 1/2
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8

16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
16 I 5/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8

0,8
0,8
0,8
0,8
0,8
0,8
0,8
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3

(rotor
locked)

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage range.


Other voltages and current types on request.

3 220-240 V / 380-420 V Y - 3 - 50 Hz

--The specifications for max. power consumption apply for

4 For soldering connections

265-290 V / 440-480 V Y - 3 - 60 Hz

50Hz operation. For 60Hz operation, the specifications have


to be multiplied by the factor 1.2. The max. working current
remains unchanged.
--Take account of the max. operating current / max. power
consumption when designing contactors, leads and fuses.
Switches: Service category AC3

09689-08.2012-Gb Subject to change without notice

www.bock.de | 71

1
2
3
4
5
6
7
8

Semi-hermetic Compressors HG

HG 2-pole
HG 2-pole Alu

Number Displacement
of
50 Hz
Voltage
cylinders
(2900 rpm)

HG 2-pole Alu K

4
4
4
4
4
4
4
4

44,3
44,3
54,7
54,7
54,7
54,7
66,1
66,1

HGX34P/315-2 A K
HGX34P/315-2 S A K
HGX34P/380-2 A K

Starting
current

kW

3
3
3
3
3
3
3
3

A
Y
25,8
25,8
24,3
24,3
32,2
32,2
38,0
38,0

A
Y
117
117
117
117
172
172
172
172

54,7 / 65,6
54,7 / 65,6
66,1 / 79,4

16,0
16,0
14,7
14,7
19,0
19,0
23,5
23,5

Oil
charge

Suction
line
SV

kg

mm I inch

mm I inch

Ltr.

95,0
58,0
95,0
58,0
103,0
68,0
102,0
67,0

22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8

35 I 13/8
35 I 13/8
35 I 13/8
35 I 13/8
35 I 13/8
35 I 13/8
35 I 13/8
35 I 13/8

1,3
1,3
1,3
1,3
1,3
1,3
1,3
1,3

(rotor

Electrical data

Weight
Starting
current

Max.
power consumption
2
kW

4
4
4

A
Y
24,3
32,2
38,0

A
Y
117
172
172

14,7
19,0
23,5

Connections 5
Discharge
line
DV

locked)

Max.
working
current
2

m/h
4
4
4

Weight

Max.
power consumption
2

Number Displacement
of
50 / 60 Hz Voltage
cylinders (2900/3480 rpm)

Type

Electrical data
Max.
working
current
2

m/h

Type

HGX34P/255-2
HGX34P/255-2 A
HGX34P/315-2
HGX34P/315-2 A
HGX34P/315-2 S
HGX34P/315-2 S A
HGX34P/380-2
HGX34P/380-2 A

Technical data

Connections 5

Oil
charge

Discharge
line
DV

Suction
line
SV

kg

mm I inch

mm I inch

Ltr.

58,0
68,0
67,0

22 I 7/8
22 I 7/8
22 I 7/8

35 I 13/8
35 I 13/8
35 I 13/8

1,3
1,3
1,3

(rotor
locked)

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage range.


Other voltages and current types on request.

380-420 V Y - 3 - 50 Hz

380-420 V Y - 3 - 50 Hz
440-480 V Y - 3 - 60 Hz

For soldering connections

--The specifications for max. power consumption apply for

50Hz operation. For 60Hz operation, the specifications have


to be multiplied by the factor 1.2. The max. working current
remains unchanged.
--Take account of the max. operating current / max. power
consumption when designing contactors, leads and fuses.
Switches: Service category AC3

72 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Dimensions and connections

HG12P/60-4 S

HG12P 4-pole

HG12P/75-4
HG12P/75-4 S

HG12P/90-4
HG12P/90-4 S

HG12P/110-4
HG12P/110-4 S

ca.220
76

B1

H,D1

E
98

A1

B,L

ca.280*
244

ca.115

SV 1)

DV

K,O

4x

ca.135

66

208
318
ca.415

10
162
192

1
2
3
4

*) With the accessory "Terminal box with reduced height" about 270 mm
(Motor protection MP10 as an extra for control cabinet installation)

5
HG22e/125-4
HG22e/125-4 S

HG22e 4-pole

HG22e/160-4
HG22e/160-4 S

HG22e/190-4
HG22e/190-4 S

88

109

223
328
ca.470

B
115

ca.135

ca.115

ca.310*
264

B,L

A1

H,D1

E
F

K,O
J
4x

12
198
ca.240

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)
1)

SV 90 rotatable
Centre of gravity
09689-08.2012-Gb Subject to change without notice

7
8

DV B1

SV 1)

Dimensions in mm
Connections see page 77

www.bock.de | 73

Semi-hermetic Compressors HG

Dimensions and connections

HG22e/125-4 A HG22e/160-4 A HG22e/190-4 A


HG22e/125-4 S A HG22e/160-4 S A HG22e/190-4 S A

HG22e Aluminium 4-pole

88

DV B1
A

ca.310*
264

B,L
SV 1)

ca.130
223
109

H,D1

E
F

115

ca.135

A1

K,O

4x

12
198
ca.240

328
ca.470

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)

HG34e/215-4
HG34e/215-4 S

HG34e 4-pole

HG34e/255-4
HG34e/255-4 S

HG34e/315-4
HG34e/315-4 S

HG34e/380-4
HG34e/380-4 S

ca.285

ca.135

X
X

46
79

ca.170
310

A1 A SV

419
ca.540

115

ca.315*
273

DV B1

1)

A
B,L

H,D1

E
F

K,O
J
4x

12
230
272

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)
1)

SV 90 rotatable
Centre of gravity

74 | www.bock.de

Dimensions in mm
Connections see page 77
09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Dimensions and connections

HG34e/215-4 A HG34e/255-4 A HG34e/315-4 A HG34e/380-4 A


HG34e/215-4 S A HG34e/255-4 S A HG34e/315-4 S A HG34e/380-4 S A

HG34e Aluminium 4-pole

ca.285

DV B1

ca.190
310

46
79

B,L
115

ca.135

ca.315*
273

A
E
F

H,D1
K,O
4x

A1 A SV 1)

419
ca.540

12
230
272

1
2
3
4

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)

HGX34P 2-pole

5
HGX34P/255-2

HGX34P/315-2
HGX34P/380-2
HGX34P/315-2 S

115

ca.135

ca.315*
273

DV B1

ca.170 (185)
46
310
79
419 (452)
ca.540 (570)

Dimensions in ( ) = HGX34P/315-2 S

HGX34P/380-2
1)

SV 90 rotatable
Centre of gravity
09689-08.2012-Gb Subject to change without notice

A1 A

A
B,L
H,D1

SV 1)

K,O
J
4x

7
8

ca.285

E
F

12
230
272

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)
Dimensions in mm
Connections see page 77

www.bock.de | 75

Semi-hermetic Compressors HG

HGX34P Aluminium 2-pole

Dimensions and connections

HGX34P/255-2 A

HGX34P/315-2 A
HGX34P/315-2 S A

HGX34P/380-2 A

ca.285

DV B1

H,D1

115

ca.135

ca.315*
273

A
B,L

ca.185 (215)
46
310
79
419 (452)
ca.540 (570)

E
F

SV

A1 A

K,O

1)

4x

12
230
272

Dimensions in ( ) = HGX34P/315-2 S A
*) With the accessory "Terminal box with reduced height" about 300 mm

HGX34P/380-2 A (Motor protection MP10 as an extra for control cabinet installation)

HGX34P/315-2 A K
HGX34P/380-2 A K
HGX34P/315-2 S A K

HGX34P Aluminium 2-pole K

ca.290

DV B1

46
79

ca.185 (215)
310
419 (452)
ca.540 (570)

Dimensions in ( ) = HGX34P/315-2 S A K

HGX34P/380-2 A K
1)

H,D1

115

ca.135

ca.315*
273

A
B,L

SV 90 rotatable
Centre of gravity

76 | www.bock.de

A1 A

E
F

SV

K,O

1)

4x

12
230
272

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)
Dimensions in mm
Connections see page 77
09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Dimensions and connections

Connections
SV
DV

HG22e 1)

Suction line
Discharge line

HG34e 1)

HGX34P-2 1)

please refer to technical data page 71 & 72

Connection suction side,


not lockable

A1

Connection suction side,


lockable

Connection discharge side,


not lockable

B1

Connection discharge side,


lockable

D1

Connection oil return


from oil separator

Connection
oil pressure gauge

Oil drain

Oil charge plug

Connection oil sump heater

15 mm

15 mm

15 mm

15 mm

Sight glass

1 1/8 " - 18 UNEF

1 1/8 " - 18 UNEF

1 1/8 " - 18 UNEF

1 1/8 " - 18 UNEF

Connection thermal
protection thermostat

Connection oil level regulator

/8 " NPTF

/16 " UNF

/8 " NPTF

/16 " UNF

/4 " NPTF

/8 " NPTF

/8 " NPTF

/16 " UNF

/8 " NPTF

/16 " UNF

/4 " NPTF

/8 " NPTF

M8

/8 " NPTF

/16 " UNF

/8 " NPTF

/16 " UNF

/4 " NPTF

/8 " NPTF

M 10

/4 " NPTF

/4 " NPTF

/8 " NPTF

/8 " NPTF

1 1/8 " - 18 UNEF

1 1/8 " - 18 UNEF

/8 " NPTF
/16 " UNF

/8 " NPTF
/16 " UNF

/4 " NPTF
/8 " NPTF

M 10

M 10

/4 " NPTF

/4 " NPTF

/8 " NPTF

/8 " NPTF

1
2
3
4
5

1 1/8 " - 18 UNEF

1 1/8 " - 18 UNEF

6
7
8

In cast iron and aluminium version

Dimensions with accessories

09689-08.2012-Gb Subject to change without notice

www.bock.de | 77

ca.340

ca.320
ca.340

ca.320

Capacity regulator

ca.300

Terminal box with reduced height

ca.300

1)

HG12P

Semi-hermetic Compressors HG

Scope of supply cast iron compressor

Scope of supply

HG12P

HG22e

HG34e

HGX34P-2

Semi-hermetic two cylinder reciprocating compressor


with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically
integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically
integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for direct start
380-420 V Y - 3 - 50 Hz
Single-section compressor housing with hermetically
integrated electric motor
Winding protection with PTC resistor sensors and electronic trigger unit
Bock MP10 230 V - 1 - 50/60 Hz
Oil charge:
HG: FUCHS Reniso SP 46
HGX: FUCHS Reniso Triton SE 55
Sight glass
Suction and discharge line valve
Inert gas charge

78 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Scope of supply aluminium compressor

Scope of supply

HG22e A

HG34e A

HGX34P-2 A HGX34P-2 A K

Semi-hermetic two cylinder reciprocating compressor


with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically
integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically
integrated electric motor
Semi-hermetic four cylinder reciprocating compressor
with drive motor for direct start
380-420 V Y - 3 - 50 Hz
Single-section compressor housing with hermetically
integrated electric motor

Winding protection with PTC resistor sensors and electronic trigger unit
Bock MP10 230 V - 1 - 50/60 Hz

Oil charge:
HG: FUCHS Reniso SP 46
HGX: FUCHS Reniso Triton SE 55

Sight glass

Suction and discharge line valve

Inert gas charge

6
7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 79

Semi-hermetic Compressors HG

Accessories cast iron compressors

Accessories

HG12P

HG22e

HG34e

HGX34P-2

1 Start unloader by means of a Bock ESS (Electronic Soft Start) IP20


(Connection clamps IP00) for installation in switch cabinet
2 Capacity regulator 12 V DC, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 24 V DC, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 24 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 110 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 230 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
3 Bock ESP (Electronic Single Phase) phase converter from single to
three phase AC for installation in switch cabinet, IP20
4 Oil sump heater 24 V DC, 80 W, IP66
permanently set version
Oil sump heater 110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
PTC heater self-regulating
Oil sump heater 400 V - 1 - 50/60 Hz, 80 W, IP66
permanently set version
5 Thermal protection thermostat (PTC sensor) IP67
6 Terminal box with reduced height (-15 mm), IP88
(Motor protection MP10 as an extra item for installation in switch cabinet)
7 MP10 with 24 V DC control voltage
MP10 with 110 V - 1 - 50/60 Hz control voltage
Special voltage and/or frequency (on request)

80 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG

Accessories aluminium compressors

Accessories

HG22e A

HG34e A

HGX34P-2 A HGX34P-2 A K

1 Start unloader by means of a Bock ESS (Electronic Soft Start) IP20


(Connection clamps IP00) for installation in switch cabinet
2 Capacity regulator 12 V DC, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 24 V DC, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 24 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 110 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
Capacity regulator 230 V - 1 - 50/60 Hz, IP65
1 capacity regulator = 50% residual capacity
4 Oil sump heater 24 V DC, 80 W, IP66
permanently set version
Oil sump heater 110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
PTC heater self-regulating

Oil sump heater 400 V - 1 - 50/60 Hz, 80 W, IP66


permanently set version

5 Thermal protection thermostat (PTC sensor) IP67


6 Terminal box with reduced height (-15 mm), IP66
(Motor protection MP10 as an extra item for installation in swtich cabinet)

7 MP10 with 24 V DC control voltage

MP10 with 110 V - 1 - 50/60 Hz control voltage

Special voltage and/or frequency (on request)


8 Kit for silent block

ESS Electronic Soft Start


1

6
Cacacity regulator
2

ESP Electronic Single Phase


3

7
8

Oil sump heater


4

Thermal protection thermostat


5

MP10 Motor Protection


7

Terminal box with reduced height


6

Silent block for aluminium version


8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 81

Semi-hermetic Compressors
for R407C up to 35 bar
At a glance
Operating limits and performance data
Technical data
Dimensions and connections
Scope of supply and accessories

84
85
87
88
89

Semi-hermetic Compressors HG R407C


up to 35 bar

At a glance

Semi-hermetic compressors for


air-conditioning applications with R407C
Based on our current semi-hermetic product range, with its outstanding advantages and features, there is now a compressor series

Available models

available for the use with the refrigerant R407C with expanded
fields of application.
Those compressors are especially suited for the application in mobile air-conditioning systems, such as railway air-conditioning.
Condensing pressures of up to 35 bar possible
(approx. 74 C condensing temperature).

Displacement

50 Hz (1.450 rpm)

HGX34e/215-4 S R407C

18,8 m/h

HGX34e/255-4 S R407C

22,1 m/h

HGX34e/315-4 S R407C

27,3 m/h

HGX34e/380-4 S R407C

33,1 m/h

Special features

The refrigerant R407C

To ensure the reliable operation of the refrigerant R407C in coun-

Besides R407C, R410A is also considered a long-term replacement

tries with high ambient temperatures of up to 50C, Bock compres-

refrigerant for R22. In addition, it is an alternative to R134a.

sors for R407C are approved for a maximum operating pressure

Suitable refrigeration oils are ester oils, such as e.g. Fuchs Reniso

of 35 bar.

SE55.

This corresponds to a condensing temperature of approx. 74 C and


opens up completely new possibilities for the use of this refrigerant.
To guarantee the highest possible operational safety, GEA Bock
uses its long experience with special compressors for other high
pressure refrigerants that are already used thousands of times in
many mobile and stationary applications.

Type key

HG X 3 4 e / 215 - 4 S R407C
R407C Version
Motor variant 2)
Number of poles
Swept volume
e-Serie

1)

HG = Hermetic Gas-cooled (suction gas-cooled)


2) S = More powerful motor e.g. air-conditioning systems

Number of cylinders
Size
Ester oil filling
Series 1)

84 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG R407C


up to 35 bar

R407C up to 35 bar Operating limits

Operating limits

HGX34e...4 S R407C

Unlimited application range



tO

Evaporating temperature (C)

tC

Condensing temperature (C)

tOh

Suction gas temperature (C)

Max. permissible operating pressure (LP/HP)1): 19/35 bar


1)

LP = low pressure HP = high pressure

1
2
3
4

R407C up to 35 bar Notes


Operating limits

Performance data

Compressor operation is possible within the limits shown on the

The performance data for R407C are based on the european standard

application diagrams. Compressor application limits should not be

EN 12900 at 50 Hz supply frequency. This signifies 20 C suction gas

chosen for design purposes or continuous operation.

temperatures without liquid subcooling.

Restrictions to the operating limits may occur when using a

The evaporating- and condensing temperautres are based on the dew

frequency converter.

point values (saturated vapour conditions).


This results in significant differences compared to specifications with
liquid undercooling and/or suction gas temperatures.
Conversion factor for 60 Hz = 1,2
Performance data for other operating points, see GEA Bock software.

09689-08.2012-Gb Subject to change without notice

www.bock.de | 85

7
8

Semi-hermetic Compressors HG R407C


up to 35 bar

R407C up to 35 bar
Type

Performance data

Performance data

Cond.

Cooling capacity QO [W]

Power consumption P [kW]

temp.

Evaporation temperature C

C
30
40

HGX34e/215-4 S R407C

50
60
70
30
40

HGX34e/255-4 S R407C

50
60
70
30
40

HGX34e/315-4 S R407C

50
60
70
30
40

HGX34e/380-4 S R407C

50
60
70

50 Hz 4-pole

12,5
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P
Q
P

25600
3,45
22400
4,38
19100
5,19
15900
5,90
12500
6,51
29600
4,30
26000
5,33
22200
6,25
18400
7,08
14800
7,85
35900
4,95
31300
6,32
26800
7,63
22200
8,76
17600
9,61
43500
6,40
38000
7,95
32200
9,52
26500
10,90
21100
11,80

10
23300
3,49
20300
4,33
17300
5,06
14300
5,69
11200
6,23
27000
4,30
23600
5,24
20200
6,08
16700
6,83
13400
7,53
32700
5,00
28500
6,25
24300
7,45
20100
8,47
16000
9,19
39600
6,35
34600
7,78
29300
9,23
24000
10,40
19200
11,20

7,5
21100
3,50
18400
4,26
15600
4,91
12900
5,47
9960
5,94
24600
4,28
21500
5,13
18300
5,89
15100
6,57
12100
7,20
29800
5,01
25900
6,16
22100
7,24
18200
8,15
14400
8,76
36000
6,27
31400
7,59
26500
8,92
21800
10,00
17400
10,70

5
19100
3,48
16600
4,17
14100
4,75
11500
5,24
8880
5,64
22300
4,23
19500
5,00
16500
5,69
13600
6,30
10900
6,87
27000
4,99
23500
6,04
20000
7,02
16500
7,81
13000
8,31
32700
6,17
28400
7,39
24000
8,60
19700
9,58
15800
10,10

0
15600
3,39
13400
3,94
11300
4,39
9190
4,75
7020
5,03
18300
4,08
15800
4,71
13400
5,25
11000
5,74
8780
6,20
22100
4,86
19200
5,72
16200
6,50
13400
7,10
10600
7,39
26700
5,93
23200
6,94
19600
7,93
16100
8,67
13100
8,94

Relating to 20 C suction gas temperature,


without liquid subcooling

86 | www.bock.de

09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG R407C


up to 35 bar

HG R407C

HGX34e/215-4 S R407C
HGX34e/255-4 S R407C
HGX34e/315-4 S R407C
HGX34e/380-4 S R407C

Electrical data

Number Displacement
of
50 / 60 Hz Voltage
cylinders (1450/1740 rpm)

4
4
4
4

18,80 / 22,60
22,10 / 26,60
27,30 / 32,80
33,10 / 39,70

Weight

Max.
power consumption
2

Starting
current

Max.
working
current
2

kW

3
3
3
3

A
/ Y
20,1 / 11,6
23,7 / 13,7
28,1 / 16,2
33,8 / 19,5

A
/ Y
132 / 76
132 / 76
132 / 76
132 / 76

m/h

Type

Technical data

6,8
8,2
9,9
12,1

Connections 4

Oil
charge

Discharge
line
DV

Suction
line
SV

kg

mm I inch

mm I inch

Ltr.

97,0
96,0
97,0
96,0

22 I 7/8
22 I 7/8
22 I 7/8
22 I 7/8

28 I 1 1/8
28 I 1 1/8
28 I 1 1/8
28 I 1 1/8

1,3
1,3
1,3
1,3

(rotor
locked)

Explanations:
1

Tolerance ( 10%) relates to the mean value of the voltage range.


Other voltages and current types on request.

3 220-240 V / 380-420 V Y - 3 - 50 Hz

--The specifications for max. power consumption apply for

4 For soldering connections

265-290 V / 440-480 V Y - 3 - 60 Hz

50Hz operation. For 60Hz operation, the specifications have


to be multiplied by the factor 1.2. The max. working current
remains unchanged.
--Take account of the max. operating current / max. power
consumption when designing contactors, leads and fuses.
Switches: Service category AC3

3
4
5
6
7
8

09689-08.2012-Gb Subject to change without notice

www.bock.de | 87

Semi-hermetic Compressors HG R407C


up to 35 bar

Dimensions and connections

HGX34e/215-4 S R407C
HGX34e/255-4 S R407C

HGX34e R407C

HGX34e/315-4 S R407C
HGX34e/380-4 S R407C

ca.285

DV B1

A B

L1
115

ca.135

ca.315*
273

ca.165
310

46
79

419
ca.540

H,D1
K,O

E
F

J1
4x

X
A1 A SV 1)

12
230
272

*) With the accessory "Terminal box with reduced height" about 300 mm
(Motor protection MP10 as an extra for control cabinet installation)

Connections
SV
DV

Suction line
Discharge line

please refer to technical data page 87

Connection suction side, not lockable

A1

Connection suction side, lockable

Connection discharge side, not lockable

B1

Connection discharge side, lockable

D1

Connection oil return from oil separator

Connection oil pressure gauge

Oil drain

Oil charge plug

J1

Oil sump heater

15 mm

Sight glass

L1

Thermal protection thermostat

Connection oil level regulator

88 | www.bock.de

/8 " NPTF
/16 " UNF

/8 " NPTF
/16 " UNF

/4 " NPTF
/8 " NPTF
M 10
/4 " NPTF

1 1/8 " - 18 UNEF


/8 " NPTF

1 1/8 " - 18 UNEF


09689-08.2012-Gb Subject to change without notice

Semi-hermetic Compressors HG R407C


up to 35 bar

Scope of supply and Accessories

Scope of supply
Semi-hermetic four cylinder reciprocating compressor with drive motor for direct start
220-240 V / 380-420 V Y - 3 - 50 Hz
265-290 V / 440-480 V Y - 3 - 60 Hz
Single-section compressor housing with hermetically integrated electric motor
Winding protection with PTC resistor sensors and electronic trigger unit Bock MP10 230 V - 1 - 50/60 Hz
Oil sump heater
110-240 V - 1 - 50/60 Hz, 50-120 W, IP66
PTC heater self-regulating
Sight glass
Oil charge
HGX: FUCHS Reniso Triton SE 55
Suction and discharge line valve
Thermal protection thermostat (PTC sensor), IP67
Inert gas charge

Accessories
1 Start unloader by means of a Bock ESS (Electronic Soft Start) IP20, (Connection clamps IP00) for installation in swtich cabinet
2 Capacity regulator 12 V DC, IP65
1 capacity regulator = 50 % residual capacity

Capacity regulator 24 V DC, IP65


1 capacity regulator = 50 % residual capacity

Capacity regulator 24 V - 1 - 50/60 Hz, IP65


1 capacity regulator = 50 % residual capacity

Capacity regulator 110 V - 1 - 50/60 Hz, IP65


1 capacity regulator = 50 % residual capacity

Capacity regulator 230 V - 1 - 50/60 Hz, IP65


1 capacity regulator = 50 % residual capacity

3 Oil sump heater 24 V DC, 80 W, IP66


permanently set version

Oil sump heater 400 V - 1 - 50/60 Hz, 80 W, IP66


permanently set version
4 Terminal box with reduced height (-15 mm), (Motor protection MP10 as an extra item for installation in swtich cabinet)
5 MP10 with 24 V DC control voltage
MP10 with 110 V - 1 - 50/60 Hz control voltage
Special voltage and/or frequency (on request)

ESS Electronic Soft Start


1

Capacity regulator
2

Terminal box with reduced height


4

09689-08.2012-Gb Subject to change without notice

Oil sump heater


3

MP10 Motor Protection


5

www.bock.de | 89

Bock Vehicle Compressors

Service - Made by GEA Bock

Because you're never done learning GEA Bock training and workshops on compressors
Many years ago, GEA Bock intensified its commitment in the area
of customer training.

Overview of training events offered:

And so we offer a comprehensive array of attractive training

- GEA Bock Practitioners' Workshop

events, from two-day practitioners' workshops in Frickenhausen to

- Training tailored to your individual needs

afterwork workshops throughout Germany. Regardless of the type

- Training for your entire staff

of training you are interested in.

- Training on your premises

Three things are characteristic of all GEA Bock training:


- The captivating way that the training director Peter Spies carries
out the events

For additional questions or advice, please contact our training


director:

- The strong practice orientation of the training events, and


- The fact that all training events from Bock are offered as a free
service

Peter Spies
Telephone +49 (7022) 945 4-157
Fax +49 (7022) 945 4-137

Current training dates can be found online at www.bock.de

90 | www.bock.de

Email: Peter.Spies@gea.com

09689-08.2012-Gb Subject to change without notice

Bock Vehicle Compressors

In touch with our customers

GEA Refrigeration Technologies:


Your partner for low temperatures

Service - Made by GEA Bock

Worldwide, Up-to-Date, Comprehensive GEA Bock on the Internet - www.bock.de


Products
--Comprehensive product brochure

GEA Refrigeration Technologies, part of the internationally active GEA Group, is a syn-

--Data on all products

onym for industrial refrigeration technology. Since the end of the 19th century, it has been

--Dimensions and exploded views

our business to cool processes and products, and to control the temperature of goods in

--Spare parts lists

transport.
You will find our solutions in the food and beverage sector; in the petrochemical, chemical, and pharmaceutical industries; on fishing ships; in natural gas liquefaction; in

Sales network

infrastructure facilities; and in ice factories. We are also at the top with know-how when

--Contact persons in over 60 countries

it comes to refrigeration at leisure facilities. After all, we have been excited about refrige-

--Direct link to your trading partner

ration for decades now. As a result, our staff enthusiastically goes about its development
and production projects to include preventive and remedial maintenance of your refri-

geration systems.

Company

This enthusiasm is highly apparent in the daily work of all companies in our Segment.

--Current company information

Whether its complete systems or individual valves: we have the experience in every sec-

--Company film

tion of our company to optimally design, manufacture, and install refrigeration systems.

--Subsidiaries

And to take full advantage of this experience, we not only carry out development in our

--History

own company: we also manufacture, assemble, and test the core components. A chain is,

--References

2
3
4
5

after all, only as strong as its weakest link: and this also applies equally well to refrigeration technology, cooling processes, and cooling chains.

News

This makes it all the more important that you have a partner in GEA Refrigeration

--Company news

Technologies that has learned to master refrigeration from A to Z. And all of this since

--Product news

1896, when Willem Grasso founded his refrigeration division. From this history of GEA

--Current dates

Refrigeration Technologies, you will profit in the form of technical expertise and top
sector know-how.
But we all live in the present and think about the future. We ponder a future in which

Toolbocks - The Refrigeration App

more and more processes need energy around the world, and fewer natural resources are

--Power Converter

available. As a result, we have taken it as our goal to create solutions that are not only long-

--Length Converter

life and cost-effective, but also energy-saving and environment-protecting. We feel obliga-

--Pressure Converter

ted to sustainability in many respects. Our objective is to produce longlife and material-

--Converter Tube Diameter

saving products over the long run as well as products that use environmentally benign

--Refrigerant Calculator

refrigerants. And we aim to produce efficiently. But our responsibility does not end at

--Location Finder

the factory gate. As a result, we take great pains to ensure that our systems are energy-

--Error Analysis/Troubleshooter

efficient and that they protect the climate. With GEA Refrigeration Technologies, you can
also count on optimal economy: saving energy indeed means reducing money spent for
energy. At the same time, you protect the environment. Thanks to our refrigeration tech-

Wordbock - Translation Tool

nology, your processes will run more economically and more ecologically. To maintain our

--Available as an app and

standard of living and to assure quality of life for future generations as well.

--As an online version on www.bock.de

Our claim of combining economy with saving natural resources is reflected in all components of our company, such as the following: compressors, chillers, heat pumps, ice
machines, fittings and valves, control systems, and many, many more. You can find proof

Know-how

of the above throughout the world. Our international corporate network and above all

--Error analysis tool

our reference projects are spread all over the globe.

--VAP software
--Comprehensive information

2 | www.bock.de

09689-08.2012-Gb Subject to change without notice

09689-08.2012-Gb Subject to change without notice

www.bock.de | 91

Excellence

Passion

Integrity

Responsibility

GEA-versity

GEA Refrigeration Technologies


GEA Bock GmbH
Benzstrae 7, 72636 Frickenhausen, Germany
Phone: +49 7022 9454-0, Fax: +49 7022 9454-137
bock@gea.com, www.bock.de, www.gea.com

GEA Group AG. All rights reserved. 09689-08.2012-Gb, Subject to change wothout notice, Copyright GEA Bock

GEA Group is a global engineering company with multi-billion euro sales and operations in more
than 50 countries. Founded in 1881, the company is one of the largest providers of innovative
equipment and process technology. GEA Group is listed in the STOXX Europe 600 Index.

Bock Compressors for Mobile Applications


Vehicle compressors for bus-, railway air-conditioning and transport refrigeration

engineering for a better world

GEA Refrigeration Technologies

Você também pode gostar