Você está na página 1de 3

GSM1900M Tower Mounted Booster

TB-1900(40W)
Features
High downlink power 46dBm for extended cell coverage. MCPA with 20MHz Instantaneous Bandwidth can support multiple GSM Downlink carriers. Low noise amplifier reduces uplink system noise figure and helps to reduce call drop and improve voice quality. Reduces handset output power to improve uplink C/I. Permits local or remote monitoring via PC or wireless modem. Alarms can be transmitted to OMC via data link or SMS. External alarm to BTS by voltage-free relay contacts. Automatic RF by-pass feature permits BTS operation when equipment or power supply fails. Internal Li-ion backup battery ensures alarm messages are transmitted when equipment or power supply fails. Designed for all outdoor application waterproof, damp-proof and omni-sealed (IP65).

Product Description
The TB-1900 is a GSM tower mounted booster (TMB) that provides both uplink and downlink amplification. The TMB unit is installed near the antenna at the tower top to boost the transmitted power for extended cell coverage. The uplink low-noise amplifier (LNA) serves to improve the sensitivity of the BTS to cope with the extended cell coverage in the downlink. The TB-1900 is powered through a separate power cable, with various power supply options. The system consists of duplexers, uplink LNA, downlink MCPA, RF by-pass switch, main control unit (MCU), distribution board, power supply unit, surge protector, wireless modem, and Li-ion backup battery. Parameter settings of the unit can be done locally via a PC with OMT, or remotely via wireless modem using OMT or OMC software. Alarms are displayed on the OMT screen and could be detected by BTS as external alarm. Through the wireless modem, the alarm data can be transmitted to the OMC automatically, or be sent as SMS to a predefined cellular device.

Functional Block Diagram

Downlink/Uplink By-pass

MCPA
Tx1 Rx1

Service Antenna 1 Ant1

B T S

BTS1

LNA1

Service Antenna 2
Rx1 Diversity

LNA2

BTS2
Uplink By-pass

Ant2

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 22Nov10 Control: 0-0-1 1/3

GSM1900M Tower Mounted Booster


TB-1900(40W)
Technical Specifications Electrical
Frequency Range, Uplink Frequency Range, Downlink Instantaneous Bandwidth Intermodulation, Downlink Total Output Power Output Power Fluctuation Maximum Uplink Gain Maximum Downlink Gain Gain Adjustment Range (1dB Step), Uplink Gain Adjustment Range (1dB Step), Downlink 9kHz to 1GHz Spurious 1GHz to 12.75GHz Noise Figure, Uplink Absolute Maximum RF Output Power Uplink Absolute Maximum RF Input Power Downlink Insertion Loss, By-pass Mode Pass Band Ripple, p-p System Group Delay Input VSWR Impedance MHz MHz MHz dBc dBm dB dB dB dB dB dBm dBm dB dBm dBm dB dB nsec mm kg VAC VDC W sec hr 1850 1910 1930 1990 20 -60 46 1 12 1 20 1 0 - 12 0 20 -36 / 100KHz -30 / 1MHz 3.0 +10 +43 2.0 2.0 500 1.5 50

Power, Mechanical & Environmental


Dimensions, H x W x D Weight (approx.) Power Supply AC Power Consumption (approx.) Power Up Waiting Time (approx.) MCU Battery Backup Time (approx.) Enclosure Cooling RF Connectors Operating Temperature Operating Humidity Environmental Class MTBF TBD 37 90 264 / 47 63Hz -48 600 60 3 Fan N-F or 7/16 Din-F C -40 to +55 95 % IP65 hr > 50,000 Note: Typical specifications at room temperature. *1 : f deviation from the center of GSM allocated carrier.

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 22Nov10 Control: 0-0-1 2/3

GSM1900M Tower Mounted Booster


TB-1900(40W)
Operation and Maintenance
Using a direct serial connection to a PC, installation and commissioning of the TB-1900 is accomplished by the OMT at the bottom PCU. Using the integrated wireless modem (data or SMS mode), equipment parameters can be monitored and controlled remotely. Controlled equipment parameters include: Channel No, UL/DL ATT, Soft ON/OFF, Over-Temp Threshold, DL Output Power Threshold, DL Input Power Threshold and Alarm Report Enable. Monitored equipment alarms and parameters include: Alarms (LNA, DL PA, Power Down, PSU Fault, Door Open, DL Input Power Low, DL Output Power Low, Over Temp), UL/DL Gain, DL Input /Output Power. The TB-1900 has been developed to take advantage of advanced network operation, where the OMC (optional) provides an effective solution for central monitoring of a group of Comba products.

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued: 22Nov10 Control: 0-0-1 3/3