W-VD/S Shear-Anchor Cartridge System


Individual attachment: Uncracked concrete Galvanized steel W-VD/A4 Shear-anchor cartridge system see 21.2 W-VD/HCR Shear-anchor cartridge system see 21.2

Evidence of performance
Approvals Test reports Drill hole cleaning Cleaning the drill hole: 1x blow-out, 1x brush-out, 1x blow-out, 1x brush-out Installation instructions Set anchor bar rotating and + impacting with hammer drill or percussion drill.
l

European Technical Approval


Option 8 for uncracked concrete

Fire Resistance

Suitable for fastening metal constructions, metal profiles, brackets, foot plates, supports, wood structures, beams etc. Heavy loads, small axial and edge distances Hardened composite mortar largely seals off the drill hole Attachment with low expansion pressure allows small edge and axial clearances Anchoring through bond between mortar, anchor bar and anchoring base. Galvanized anchor bar in the sizes M8, M10, M12, M16, M20 and M24 Galvanized steel: European Technical Approval ETA-06/0074 Dimensioned in accordance with the Guideline for European Technical Approval (ETAG) of Metal Anchors for Use in Concrete, Annex C, dimensioning method A Fire resistance: F30, F60, F90, F120: One-sided fire stress according to DIN EN 1363-1:1999-10

1. Applications
l l

2. Advantages
l l l

l l

l l l l

Can be used for medium to heavy loads With European Technical Approval, the anchor can be used in reinforced or non-reinforced standard concrete with a strength class of at least C20/25 and at most C50/60 in accordance with EN 206:2000-12 Anchorage with European Technical Approval in uncracked concrete (concrete pressure zone) The anchor may be used for anchorage with primarily static loads (e.g. own weight, installations, support materials) or quasi-static loads Installation in dry or wet concrete The temperature in the mortar area may not exceed +50 C and briefly +80 C For use in concrete < C20/25 and pressure-resistant natural stone (without approval) W-VD/S (galvanized steel) can be used in dry interior rooms

3. Properties
l

l l

Setting instructions

MWF - 04/08 - 04276 -

Drill hole

1x blow-out, 1x brush-out, 1x blow-out, 1x brush-out

Resin must flow like honey when cartridge is hand-warm

Push in cartridge

Set threaded rod rotating/ impacting

Visual check of mortar filling quantity

Observe the hardening time

Mount component, apply torque

F0071

W-VD/S Shear-Anchor Cartridge System


Performance data
Anchor diameter
Perm. transv. Perm. centered load1) tensile load1) of a single anchor of a single anchor w/o edge influence w/o edge influence

21.1

M8 Nperm [kN] = C20/25 50C 2)/80C 3) 7.9

M 10 11.9

M 12 15.9

M 16 19.8

M20 29.8

M24 35.7

Pressure zone (uncracked concrete C 20/25 M8: s 3 hef, c 1.5 hef M10-M24: s 2 hef, c 1 hef)

Pressure zone (uncracked concrete C 20/25, Vperm [kN] = C20/25 c 10 hef) Mperm [Nm] F30 [kN] F60 [kN] F90 [kN] F120 [kN]

5.1 10.9 2.3 1.29 0.79 0.53

8.0 21.1 3.64 2.04 1.3 1.0

12.0 37.1 5.26 3.07 2.0 1.5

22.3 94.9 9.79 5.72 3.68 2.67

34.9 185.7 15.28 8.93 5.75 4.16

50.3 320.6 22.01 12.86 8.28 6.0

Permissible bending torque Fire resistance time Fire resistance duration

Characteristic values
Minimum axial spacing Axial spacing Minimum edge spacing Edge spacing Minimum component thickness Effective anchoring depth Nom. drill dia. Drill cutting dia. Drilled hole depth Through-hole in component to be connected Torque during anchoring Cleaning brush dia. smin [mm] scr,N [mm] cmin [mm] ccr,N [mm] hmin [mm] hef [mm] d0 [mm] dcut [mm] h0 [mm] df [mm] Tinst = [Nm] D [mm] 40 240 40 120 110 80 10 10.5 80 9 10 10.8 45 180 45 90 120 90 12 12.5 90 12 20 13 55 220 55 110 140 110 14 14.5 110 14 40 15 65 250 65 125 160 125 18 18.5 125 18 80 19 85 340 85 170 220 170 25 25.5 170 22 120 27 105 420 105 210 260 210 28 28.5 210 26 180 29

Drill hole cleaning


Cleaning brush (steel) Machine mounting Extension Brush template Blow-out pump Art. No. Art. No. Art. No. Art. No. Art. No. P. Qty. = 1 P. Qty. = 1 P. Qty. = 1 P. Qty. = 1 P. Qty. = 1

M8 M24: 1x blow-out, 1x brush-out, 1x blow-out, 1x brush-out 0905 499 001 0905 499 002 0905 499 003 0905 499 004 0905 499 006 0905 499 0084) Hexagon: Art. No. 0905 499 101 SDS plus: Art. No. 0905 499 102 0905 499 111 0905 499 099 Blow-out pump: Art. No. 0903 990 001

Anchor dimensions
20 110 60 150 15 115 30 130 65 165 90 190 10 135 35 160 85 210 10 5915 012 095 W-VD M12 10 5915 112 250 W-VD-A/S M12-125/250 125 250 10 5915 012 095 W-VD M12 10 5915 112 300 W-VD-A/S M12-175/300 175 300 20 165 45 190 85 230 10 5915 016 095 W-VD M16 10 5915 116 250 W-VD-A/S M16-105/250 105 250 10 5915 016 095 W-VD M16 10 5915 116 300 W-VD-A/S M16-155/300 155 300 20 220 60 260 10 5915 020 175 W-VD M20 10 5915 120 300 W-VD-A/S M20-100/300 100 300 15 260 5 5915 124 260 W-VD-A/S M24-15/260 5 5915 024 210 W-VD M24

l [mm] tfix [mm]

max. mounting height

10 5915 010 080 W-VD M10 10 5915 110 115 W-VD-A/S M10-15/115

10 5915 010 080 W-VD M10 10 5915 110 130 W-VD-A/S M10-30/130

10 5915 010 080 W-VD M10 10 5915 110 165 W-VD-A/S M10-65/165

10 5915 010 080 W-VD M10 10 5915 110 190 W-VD-A/S M10-90/190

10 5915 012 095 W-VD M12 10 5915 112 135 W-VD-A/S M12-10/135

10 5915 012 095 W-VD M12 10 5915 112 160 W-VD-A/S M12-35/160

10 5915 012 095 W-VD M12 10 5915 112 210 W-VD-A/S M12-85/210

10 5915 016 095 W-VD M16 10 5915 116 165 W-VD-A/S M16-20/165

10 5915 016 095 W-VD M16 10 5915 116 190 W-VD-A/S M16-45/190

10 5915 016 095 W-VD M16 10 5915 116 230 W-VD-A/S M16-85/230

10 5915 020 175 W-VD M20 10 5915 120 220 W-VD-A/S M20-20/220

Designation Anchor bar

W-VD-A/S Anchor Bar, galvanized steel Packing unit Designation Shear-anchor mortar cartridge

Art. No. P. Qty.

10 5915 020 175 W-VD M20 10 5915 120 260 W-VD-A/S M20-60/260

10 5915 108 110 W-VD-A/S M8-20/110

10 5915 108 150 W-VD-A/S M8-60/150

10 5915 008 080 W-VD M8

W-VD shear-anchor mortar cartridge Packing unit


MWF - 04/08 - 04277 -

Art. No. P. Qty. [pieces]

10 5915 008 080 W-VD M8

1)

2) 3) 4)

The part safety coefficients of the resistances and a part safety coefficient of the effects of F = 1.4 have been taken into account. For the combination of tensile and transverse loads, for edge influence and dowel groups, please refer to the Directive for European Technical Approval (ETAG) Appendix C. Maximum long-term temperature. Maximum short-term temperature. Cleaning brush without M6 connecting thread.

F0072

5 5915 024 210 W-VD M24

5 5915 124 300 W-VD-A/S M24-55/300

55 300

Anchor diameter Total length

M8

M 10

M 12

M 16

M20

M24