Direct Decade addressing 198 devices per loop (99 sensors and 99 call point/ monitor/control modules) Twin LEDs for 360 degree visual alarm indication Removable cover for easy cleaning access Very low activity chamber (ionisation sensor) Simple plug-in installation with electronicsfree base Local magnet test facility Tamper resistant facility Three year warranty LPCB Approved to EN54
Rate of rise heat sensor (FDX-551REM) This rate of rise heat sensor offers a Type A1R response to pr-EN54 PT.5 with a 58C fixed element. Fixed temperature heat sensor (FDX-551EM) This sensor provides a Type A1S response to pr-EN54 PT.5 and has a set point of 58C. High temperature heat sensor (FDX-551HTEM) This sensor provides a Type BS response to prEN54 PT.5 with a set point of 78C.
ISO-X Isolation module allowing segregation of the analogue loop into protected areas. IBS3 Addressable, loop powered base sounder. No additional base required. AWS3/R Addressable, loop powered wall sounder, Red, complete with matching base. AWS3/W Addressable, loop powered wall sounder, White, complete with matching base. IBS-LIDR Loop Powered Base Sounder Cover Plate, Red. For use with IBS3 base when sensor is not installed. IBS-LIDW Loop Powered Base Sounder Cover Plate, White. For use with IBS3 base when sensor is not installed. CMX-10R 10 way individually addressable relay PCB. MMX-10 10 way individually addressable input PCB.
compatible devices
B501 Common base socket for all types of intelligent sensors (not HPX-751E). This base is electronics free allowing cabling to be tested for continuity prior to installation of the sensors. B524IE Isolation device built into a base suitable for all intelligent sensors (not HPX751E). B524IEFT FET isolation device built into a base suitable for all intelligent sensors (not HPX-751E). B524RE Relay base providing local output for the installed sensor. Suitable for all intelligent sensors (not HPX-751E). DH500 Duct probe. DH500 AC/DC Duct probe with local switching facilities (local power required). M500KACGB KAC style addressable call point with integral LED. MMX-1 Input module suitable for accepting signals into the loop from contact devices such as water flow sensors, security contacts, key-switches, etc. The device is monitored by use of an end of line resistor. MMX-102E Micro version of the above. CMX-2 Output device suitable for connection of a monitored sounder circuit requiring external power or for use as a relay not requiring any additional power. MRM-1 - 230Vac 5A rated control module PCB suitable for direct switching of mains powered devices. Up to two units may be mounted in the Notifier multi mount enclosure, 002-445. MRM-1/DIN - DIN rail mounting version of the above. PS2/CMX Self-contained power supply and battery charger complete with address module. Suitable for connection of two monitored sounder circuits. Requires mains power and internally fitted batteries. ZMX-1 Zone monitor unit suitable for connection to a single zone of conventional devices.
advanced detection
Often, our traditional smoke sensors are whats needed. But as technology leader with more than half a century of experience, NOTIFIER knows there is no cure all, one size fits all sensor. Unique hazards and environmental conditions require different sensors. So when special conditions exist we look to our advanced detection systems. By combining the right sensors and controls, we provide the right solution to unique detection problems. Sensors such as VIEW - Very Intelligent Early Warning, HARSH - A Hostile ARea Smoke Head, OptiPlex - A self optimising optical and thermal multi sensor and HAZARD - An intrinsically safe analogue addressable sensor, provide a wide range of advanced detection products.
T: +44 (0) 1444 230 300 F: +44 (0) 1444 230 888 E: sales@notifier.ltd.uk www.notifier.ltd.uk
Every care has been taken in the preparation of this data sheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice.