Escolar Documentos
Profissional Documentos
Cultura Documentos
3
4
5
6
1 Pluri-anchored piling with approached anchors
for a Trade Centre in San Marino
Contractor: San Marino Strade sa, San Marino
Client: Valpharma sa, San Marino
2 Rijeka World Trade Centre (Croatia)
Contractor: Geokarst Engineering srl, Trieste (Italy)
Main Contractor: World Trade Centre, Rijeka (Croatia)
Client: Geotehnika d.d., Zagreb (Croatia)
3 P.c. pilings and anchors
Parking Urbaniana University - Gianicolo, Rome (Italy)
Contractor: S.G.F. spa, Rome (Italy)
Main Contractor: Impregilo spa, Milan (Italy)
Client: Universit Urbaniana, Rome (Italy)
4 Anchors on pit retaining pilings
Dante Square Station of Naples Underground, (Italy)
Contractor CE.S.I.F. spa, Naples (Italy)
Client: Metropolitana di Napoli spa, Naples (Italy)
5 Aosta-Monte Bianco Highway - lot. 3
Contractor: Viadotti di Courmayeur scrl, Rome (Italy)
Client: RAV spa (Valle d'Aosta
Highway Connection), Genoa (Italy)
6 Admiral Point Centre
San Marino Customs House
Contractor: GE.O.S. sa, San Marino
Client: Admiral Point Centre sa, San Marino
Consolidation works in the western slope of Castelli - Teramo (Italy)
Contractor: GEO sas, L'Aquila (Italy) - Main Contractor: Consortium Castelli scrl, L'Aquila - Client: Municipality of Castelli - Teramo (Italy)
1 Modern and contemporary Art Museum
in Rovereto - Trento (Italy)
Contractor: Lamaro Appalti spa, Rome (Italy)
Main Contractor: Municipality of Rovereto, Trento (Italy)
Client: Province of Trento, (Italy)
2 Zambana dihedral consolidation works, Trento (Italy)
Contractor: Trevi spa, Cesena (FC), (Italy)
Client: Autonomous Province of Trento (Italy)
3 Setting of squares and infrastructures
of Gioia Tauro Port, Reggio Calabria (Italy)
Contractor: Teknosonda srl, Lamezia Terme - Catanzaro (Italy)
Main Contractor: Todini Costruzioni Generali spa, Rome (Italy)
Client: A.S.I. (Consortium for the Area of Industrial Development
of Reggio Calabria, (Italy)
4 Toschi Avenue Parking, Parma (Italy)
Contractor: Ing. Giovanni Rodio & C. spa,
Casalmaiocco - Lodi (Italy)
Main Contractor: Toschi scarl, Parma (Italy)
Client: Gespar spa, Parma (Italy)
17
1
2
3
4
STRESSING JACKS PT SERIES
18
TENSACCIAI manufactures 4 types of "PT" series jacks (plurijacks) which differ in
tensioning section, weight and dimensions. All are equipped with automatic lock-off.
m.u. PT 150 KN PT 200 KN PT 250 KN PT 300 KN
Capacity kN 150 200 250 300
Stroke mm 100 200 200 200
Weight Kg. 16 23 23 28
Tensioning section cm
2
32.80 47.20 47.20 58.32
Max. tensioning pressure bar 550 450 550 550
Max. return pressure bar 180 180 180 180
Max. locking pressure bar 165 165 165 165
Connection -- 2 tubes 2 tubes 2 tubes 2 tubes
A mm 85 100 97 110
B mm 600 1000 930 870
C mm 60 85 77 88
Subject to modification Additional sizes available on request
C
B
STRESSING JACKS MT SERIES
19
TENSACCIAI manufactures 8 types of MT series jacks (monogroup), with capacity ranging from 1000 to
9000 kN. MT jacks have been designed and built by TENSACCIAI considering different stressing needs:
minimum strand waste (300 mm. to 500 mm.), jack built-in hydraulic circuit, automatic lock-off, easy removal
and control of the wedges, jack rotation around its own axis, making it easier to place and wedge onto the
tendon. The high quality of parts and materials allows this jack to be used even under the most severe
operating conditions. TENSACCIAI MT jacks can also be supplied in the TAC version.
C
B
A
E
m.u. MT 1000 KN MT 1500 KN MT 2500 KN MT 3000 KN MT 3500 KN MT 4500 KN MT 6000 KN MT 9000 KN
Capacity kN 1000 1500 2500 3000 3500 4500 6000 9000
Stroke mm 250 250 250 250 250 250 300 250
Weight Kg. 100 180 290 350 420 600 1000 1250
Tensioning section cm
2
155.51 302.18 361 400.55 492.44 725.71 879.6 1625
Max. tensioning pressure bar 600 500 700 700 700 700 700 700
Max. return pressure bar 180 180 180 180 180 180 180 180
Max. locking pressure bar 165 165 165 165 165 165 165 165
Tensioning overlength with lock-off cm. 35 37 37 38 38 45 51 52
A mm 950 930 951 984 970 1107 1237 1016
B mm 155 130 150 154 148 200 207 195
C mm 137 152 173 195 214 243.5 295.5 322
D mm 162 185 213 236 252 310 380 407
E mm 248 310 339 370 415 512.5 615 714
Subject to modification Additional sizes available on request
m.u. X90ES X90E X16ES X6E X6EX X6EY X4E X4EX X4EY
Weight Kg. 450 450 450 170 170 150 100 90 90
Power KW 10 7.5 10 5 4 4 4 4 4
Max. pressure bar 700 700 550 500 450 430 500 430 420
System MT MT PT PT PT PT PT PT PT
Oil quantity lt. 100 90 80 60 60 60 50 40 40
Connection 3 tubes 3 tubes 2 tubes 2 tubes 2 tubes 2 tubes 2 tubes 2 tubes 2 tubes
A mm 1000 1000 1000 800 800 800 760 760 760
B mm 1300 1300 1300 800 800 800 500 500 500
C mm 800 800 800 600 600 600 400 400 400
HYDRAULIC PUMPS
20
TENSACCIAI manufactures 4 types of hydraulic pumps which differ in performances and
dimensions.
All are equipped with hydraulic circuit for automatic lock-off. Each series has different types
in order to meet any technical requirement of the job site.
Subject to modification Additional sizes available on request
X 90 ES
X 6 E X 4 E
CYCLIC STRESSING: TENSACCIAI TAC SYSTEM
21
Cyclic stressing is the most correct system for the execution of ground or rock anchors. The
purpose of cyclic stressing is to study during a certain time the behaviour of the bond length
with regard to the ground, and to test the anchor before it is considered suitable for the function
it has been designed for.
By cyclic stressing the right tension applied to the anchor is determined, as the system studied
by TENSACCIAI enables to calculate separately the values of plastic (permanent) and of
elastic strains (see diagram).
TENSACCIAI TAC system has been studied to perform cyclic stressing with maximum speed,
safety and automaticity. It consists of the use of a hydraulic device which allows the insertion
of the wedges in the jack in such a way that it does not prevent the release of stresses, as
foreseen in this particular kind of stressing.
N
Nc
Ni
N
No
k e
1
t =
Nc lt
Es As
Nc = testing force
No = alignment force
As = actual cross section of prestressing steel
Ni = ground anchor prestressing force
t = theoretical elastic elongation
k = permanent ground anchor elongation
e = ground anchor elastic modulus
Es = steel elastic modulus
N = force increase
lt = theoretical free length
Testing cyclic diagram at constant force
22
EQUIPMENT
TECS SYSTEM (TENSIONING ELECTRONIC CONTROL SYSTEM)
The control board can be connected to the electronic equipment, called TECS
system (Tensioning Electronic Control System), which performs an instantaneous
digital reading of both pressure and elongation, during each stressing phase.
The elongation is measured simultaneously, for all jacks operating on the
pump, with a precision of one tenth of a mm. (0.1 mm).
This system allows to obtain the average of the values and, connecting the
TECS system to a plotter, to print an automatic report of tensioning and
elongation data in real time.
DYNAMOMETER
It is the instrument that allows to verify the calibration of tensioning system's
pressures. It is made of an aluminium box housing a digital instrument
that performs precise pressure readings (1 bar). It is available in the 'D'
version, combined with an hydraulic transducer, as a calibration dynamometer
for the 'PT' jacks. It is also available in the 'C' version, as a sample pressure
gauge to be combined with an 'MT' jack to calibrate the pump-jack system.
TENSACCIAI dynamometers are supplied with calibration certificate
issued by an Official Laboratory.
LOAD CELL
TENSACCIAI offers a wide range of thoroidal load cells duly studied for
its own anchorages with capacity ranging from 200 up to 4500 kN. The
equipment is composed of a digital reader with connection wire and of a
thoroidal cell equipped with fitted spacers plates.
The cells have following characteristics: precision class equal to 1%, max.
load charge without any calibration alteration equal to 130% of the declared
capacity, connector and wire IP55.
The portable digital reader has a reading resolution of 50 kN and a LED
display. It is equipped with feeding battery, battery recharger and an IP55
connection wire with different lengths.
23
1-2 Ground anchors on a retaining wall, Monaco (France)
Contractor: Lenta (France) sarl, Menton (France)
Client: Nicoletti sa, Carros Cedex (France)
3 Atlante Trade Centre, San Marino
Contractor: GE.O.S. sa, San Marino
Client: Consortium Atlante srl, San Marino
4 Hotel-Casino Belle Bay Plaza, Manila (The Philippines)
Contractor: Trevi spa, Cesena (FC), (Italy)
Client: Belle Bay City Corporation (The Philippines)
5 Singkarak Hydroelectric Power Station, Indonesia
Contractor: Dumez International sa, Nanterre (France)
Client: Joint Operation Dumez International/
Impregilo spa/PT Istaka Karya
4
NORMS
24
The norms in force to which TENSACCIAI refers in organising its anchors production are the
following:
- EN 1537:2002 Execution of special geotechnical works - Ground anchors - June 2002
- AICAP Recommendations: Ancoraggi nei terreni e nelle rocce (Italy, 1993)
- PTI Recommendations for prestressed Rock and Soil Anchors (USA, 1996)
- British Standard Code of Practice for Ground Anchorages - BS 8081:1989 (Great Britain, 1989)
- Recommandations Eyrolles Tirants d' Ancrage T.A. 95 (France, 1995)
- SIA 267:2003 Gotechnique (Switzerland, 2003).
Zambana dihedral consolidation works, Trento (Italy)
Contractor: Trevi spa, Cesena (FC), (Italy)
Client: Autonomous Province of Trento (Italy)
Versilia New Hospital, Viareggio - Lucca (Italy)
Contractor: Fondamenta srl, Milan
Client: Consortium Impregilo spa - CMB srl, (Italy)
Consolidation works in the town of Canzano - Teramo (Italy)
Contractor: GEO sas, L'Aquila (Italy) - Main Contractor : Co. Petrilli, L'Aquila
Client: Municipality of Canzano - Teramo (Italy)
Design: Arch. Paola Bobba - Arch. Elena Astolfoni - Milan
Stampa: Grafiche Saita - Milan (Italy) - 2004