The data shown are not universal. These parameters are valid for the following conditions: - Bulgaria, Sofia; - Indoor temperature 22oC; - Air flow 3000m3/h; - Installation working time 10 of 24h. - Installation life time 10 years; - Energy price 0.1 Euro/kWh; - 8% annual maintenance costs; - Energy price growth 12% per year; - The initial expenses are average;
AHU - A
AHU - A
Q ,kWh 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 -15
AHU - A AHU - B
AHU - B
REC
-10
-5
10 text ,
AHU - C
REC
REC
Q ,kWh 10000 9000 8000 7000 6000 5000 4000 3000 2000 1000 0 -15
AHU - A AHU - D
AHU - D
-10
-5
10 text ,
AHU - E
REC
Applications of heat recovery units: 4000 Ventilation and air-conditioning systems, which provide fresh air supply in: 1000 0 - Office and residential buildings; -15 -10 -5 0 5 10 text , - Hotels, restaurants, cafes, nightclubs; - Sports halls, gyms and swimming pools; - Hospitals, schools, laboratories; - Cinemas, theaters, concert halls; - Food industries bakeries; - Technological systems; - Industrial ventilation.
2000
Description Units for secondary use of energy of the exhaust air in ventilation and air-conditioning systems. Operation temperatures from -20C to +50C. Designed to work with clean air in non-aggressive and explosion-proof environment
Construction Supporting construction, made by anodized aluminum profiles. Thermo and sound insulated panels, powder coated RAL7035 - Internal insulation Firex 10 mm, fire resistance class: 0-BS 476 Part 6; class 1 BS 476 Part7; - Sandwich panels 25 mm with XPS insulation class M1 or fiberglass class M0;
Cross flow aluminum plate heat exchanger with efficiency up to 55%; Double inlet direct drive centrifugal fans 230V, 50Hz, IP 20 (higher protection on request); Air filters class G4 EN 779:2002; Rectangular or round duct connector; Drain tray with connection; Configuration allows easily modifying position of the filters, fans and duct connectors; Service doors from the bottom and from the side; By-pass with multiple leaf damper; Heating/ cooling coil on request; Hanging support or basic steps on request; Roof panel for outdoor installation on request. Control and management systems - see section 7
05.01-02 EVB AL
Overall and joined dimensions EVB AL, H Horizontal installation
Max. air flow [m3/h] 500 700 1000 2200 3000 3500 4500
Max. air flow [m3/h] 500 700 1000 2200 3000 3500 4500
By-pass with internal multiple leaf damper; Manual control - on request; Belimo ON-OFF actuator standard version
05.01-04 EVB AL
Overall and joined dimensions EVB AL-HBS (heating water coil and by pass), H Horizontal installation
[mm] [mm] L [mm] Hmax [mm] C [mm] 1050 1050 1200 1300 1300 1450 450 520 650 750 850 1150 1600 1600 1900 1900 1900 2500 520 590 720 820 920 1220 225 235 300 265 335 335
D [mm] [mm] G [mm] 180 210 260 290 290 290 250 280 315 355 355 355 225 300 300 400 400 400
d [mm] 1 1 1 1
By-pass with internal multiple leaf damper; Manual control - on request; Belimo ON-OFF actuator standard version Two rows water coil Cu/Al; Four rows water coil (cooling) - on request.
Air flow [m3/h] Model EVB-P-04 Fan CBM/2-133/190-185W Nominal power [W] 2 x 185 Nominal current [A] 0.8
EVB AL-06
Air flow [m3/h] Model BV AL-06 Fan BM/2-146/180 Nominal power [W] 2 220 Nominal current [A] 1.01
05.01-06 EVB AL
Technical characteristics
EVB AL-10
Air flow [m3/h] Model BV AL-10 BV AL-10/3V Fan BM/4-180/180 BM/4-180/180-V Nominal power [W] 2 147 2 147 Nominal current [A] 1.5 1.33
EVB AL-20
Air flow [m3/h] Model BV AL-20 BV AL-20/3V Fan BM/4-240/240 BM/4-240/240-3V Nominal power [W] 2 370 2 370 Nominal current [A] 4.2 3.8
EVB AL-30
Air flow [m3/h] Model BV AL-30 BV AL-30/3V Fan BM/4-270/200 BM/4-270/200-3V Nominal power [W] 2 370 2 370 Nominal current [A] 4.0 3.0
EVB AL-35
Air flow [m3/h] Model BV AL-35 Fan BM/4-270/270 Nominal power [W] 2 550 Nominal current [A] 6.2
05.01-08 EVB AL
Technical characteristics EVB AL-45
[Pa]
[m3/h] Note: The dotted curve refers to heat recovery unit with heat exchanger 800/600-2R Model BV AL 45 Fan BM - 10/10 4P, 3V Nominal power [W] 2750 Nominal current [A] 7,8
Sound pressure level on frequency bands [dB] Model EVB PP-04 EVB AL-06 EVB AL-10 EVB AL-20 EVB AL-30 EVB AL-35 EVB AL-45 Hz Inlet Outlet Rad. Inlet Outlet Rad. Inlet Outlet Rad. Inlet Outlet Rad. Inlet Outlet Rad. Inlet Outlet Rad. Inlet Outlet Rad. 63 49 47 40 50 48 41 46 46 47 49 48 48 49 48 48 52 51 51 52 51 45 125 54 55 45 55 56 46 51 53 48 56 58 52 56 57 52 61 63 58 61 63 53 250 51 56 40 52 58 42 56 58 49 64 67 56 63 65 55 66 69 61 66 69 55 500 50 65 41 51 66 41 61 65 50 66 70 55 66 71 54 67 71 56 67 71 50 1000 48 68 44 49 70 45 56 68 38 63 75 52 64 75 52 64 75 53 64 75 47 2000 52 70 43 53 71 45 51 67 39 56 74 46 57 74 45 57 75 47 57 75 42 4000 50 66 41 50 67 42 47 66 34 54 71 41 56 72 42 55 72 42 55 72 38 8000 41 63 34 43 65 35 40 58 27 43 62 33 45 63 32 45 64 35 45 64 31
Configuration A and C as standard. Modification B and D - on customers request. Accessories External high efficiency filter F7, Pmax = 80Pa Sound attenuators External electric heater Roof for outdoor installation Flexible duct connectors 3-way valve for water coil Freeze protection Pressure switch 3-speed switch Hanging supports Basic steps Frame for outdoor installation Control and management systems - see section 7
Order designation EVB AL - 30 /3V -HBS BS By pass; HBS heating coil and by pass 3-speed fan Model Heat recovery unit - Main parameters - Optional parameters