The Edge Fulton engineers have taken decades of experience with designing and manufacturing vertical tubeless boilers

and have created the Edge. All of the time proven benefits and design features of the Classic Vertical Tubeless Boiler have been maintained. The 2-Pass design has been optimized with the addition of the flue gas enhancing system. Using a massive heat transfer surface, high velocity flue gases travel over a cylindrical grid of heat convection fins. These fins radiate additional heat evenly to the outer side of the water vessel, resulting in maximum efficiency while still maintaining the pressure vessel's longevity. The results are efficiencies of up to 84 percent! Built and stamped to the ASME Code, Fulton 4-30 BHP vertical tubeless steam boilers are CSA Approved, UL Approved as packaged boilers, and are manufactured to CSD-1 Code, with state of the art microprocessor burner controls. Fulton vertical tubeless boilers can be ordered with combination oil and gas capabilities or can be converted at any time simply and economically. All Fulton boilers are completely trimmed, packaged boilers. No additional fuel train items or electrical wiring is needed.

Specifications
Standard Models Unit Size: HP 4 6 10 15 20 145 215 345 517 690 1000 BTU/HR Output 37 55 87 130 174 1000 KCAL/HR 149 221 356 533 712 LB/HR Steam Output 68 100 162 242 323 KG/HR Approximate Fuel Consumption at Rated Capacity Propane Gas Natural Gas Ft3/HR M3/HR Ft3/HR M3/HR 70 105 170 250 2 3 4.8 7.1 175 260 420 630 5 7.4 11.9 17.8 30 1035 261 1066 484

330 500 9.3 13.6 840 1260 23.8 35.7

1 1 1 1 1.25 1.5 Natural Gas Boiler IN Connection Size MM 25 25 25 25 32 38 3450 RPM/60 CY 1/3 1/3 1/3 1/3 1/3 gas 3/4 Burner Motor HP 2850 RPM/50 CY 1/3 1/3 1/3 1/3 3/4 oil 3/4 Electric Power Requirements (in Amps) 5.2 5.2 5.2 5.2 5.2 9.2 120V, 60 CY, 1 Phase 9.2 oil 2.6 2.6 2.6 2.6 2.6 gas 4.6 240V, 50/60 CY, 1 Phase 4.6 oil 1.9 1.9 1.9 1.9 1.9 gas 3.1 208V, 60 CY, 3 Phase 3.1 oil 1.6 1.6 1.6 1.6 1.6 gas 2.8 240V, 50/60 CY, 3 Phase 2.8 oil 0.8 0.8 0.8 0.8 0.8 gas 1.4 480V, 50/60 CY, 3 Phase 1.4 oil 14 16 24 39 77 170 U.S. GAL Water Content 53 61 91 148 292 644 LITERS

Dimensions

Standard Models A. Boiler Height

4 6 IN 47.5 57.5 MM 1207 1461 B. Boiler Height With IN 65 75 Trim & Fuel Train MM 1651 1905 C. Overall Depth Stack IN 44 44 to Burner Fan Housing MM 1118 1118 D. Boiler Diameter IN 26 26 MM 660 660 E. Overall Width with IN 33 33 Water Column MM 838 838 F. Flue Outlet Diameter IN 6 6 MM 152 152 G. To Center of IN 42 52 Flue Outlet MM 1070 1320 H. Feedwater Inlet IN 27 33 MM 685 840 I. Handholes IN 19 19 MM 485 485 J. Blowdown Outlet IN 15 15 MM 380 380 K. Water Column IN 14 14 Extension MM 355 355 L. Gas Train Extension IN 22.5 22.5 (CSD -1) MM 572 572 Minimum Clearances M. Clearance Required IN 72 82 for Burner Removal MM 1828 2083 Boiler Connections IN 1 1 N. Steam Outlet 15 PSI MM 25 25 IN 0.75 0.75

10 15 20 63.5 69.5 72.5 1613 1765 1842 80.5 86.5 92.5 2045 2197 2350 46 47 60 1168 1194 1524 28 30 39 710 760 990 33.5 35.5 43 851 902 1091 6 8 10 152 203 254 58 63 66 1473 1600 1675 33 33.5 34 840 851 865 19 19 19 485 485 485 15.5 15.5 16.5 394 394 420 14 14 14 355 355 355 21.5 20.5 25 546 521 635

30 82.5 2096 102 2591 67 1702 46 1170 49 1244 12 305 73.5 1867 34 865 19 485 16.5 420 14 355 27 686

86 92 96 106 2184 2337 2438 2692 1.5 38 2 51 2 51 1.5 3 76 2

1 1.25

N. Steam Outlet 150 PSI

MM IN O. Safety Valve Outlet 15 PSI MM IN O. Safety Valve Outlet 150 PSI MM IN P. Safety Valve Inlet 15 PSI MM IN P. Safety Valve Inlet 150 PSI MM IN Q. Feedwater Inlet MM IN R. Blowdown Outlet MM IN S. Water Column Blowdown MM Weights Approx. Shipping Weight

19 0.75 19 1 25 0.75 19 0.75 19 0.75 19 1 25 1 25

19 25 32 38 51 0.75 0.75 1.5 1.5 1.5 19 19 38 38 38 1 1 1 1.25 1.25 25 25 25 32 32 0.75 0.75 1.25 1.25 1.25 19 19 32 32 32 0.75 0.75 0.75 1 1 19 19 19 25 25 0.75 1 1 1 1 19 25 25 25 25 1 1 1 1.25 1.25 25 25 25 32 32 1 1 1 1 1 25 25 25 25 25

LB 1400 1700 2000 2280 3400 4780 KG 635 773 910 1036 1545 2173

Cutaway

1. Steam Outlet 2. Fulton designed and manufactured power burner fires down the full length of the furnace for maximum heat transfer. 3. Surface blowdown outlet 4. Flue Gas Enhancing System - an expansion chamber at the top of the passageway equalizes the pressure distribution of the flue gas, ensuring even heat distribution. 5. Large steam space 6. Single, complete control panel box houses all other controls for safe operation. 7. Heat convection fins are optimized with The Edge boiler, providing a significant increase in heat transfer surface area. 8. Top castable flame retainer increases occupancy time of the flue gases to complete combustion process. 9. Large easily accessed handholes are strategically located for inspection and clean out. 10. Flue passageways. Two pass operation has been maximized on The Edge, resulting in increased efficiency without sacrificing pressure vessel longevity. 11. Blowdown outlet 12. Water Inlet

13. 14. 15. 16. 17. 18. 19.

Extra thick high temperature specially packed insulation surrounds the entire boiler. Water vessel completely surrounds the furnace wall and the outer water jacket containing the convection fins. Spinning cyclonic flame Flue Outlet Entire boiler is UL Listed and built to all applicable codes. All controls, gas train and oil-fired units comply to CSD-1. Stainless Steel Jacket - standard with The Edge.