Single point load cells

Special features
OIML-R60 approval Max. Capacities: 30 kg...660 kg Off center load compensated (OIML R76) Meets EMC standards (EN 45 501) 6-wire circuit

Optional:
Reduced minimum LC verification interval (vmin) for multi range applications Explosion proof versions different cable lengths Aligned output, suitable for connection in parallel

Dimensions (in mm; 1 mm = 0.03937 inches)


Load direction 52 16 Identification plate 18

62.3

60 94

60 17

Connection cable (see page 3)

63.5

50

35

8xM8

107 188

35

Mounting: Cylindrical head screw M8-10.9 (660 kg: M8-12.9) Tightening torque: 32 Nm (660 kg: 39 Nm)

B2192-1.0 en

Data Sheet

PW16A...

Specifications
Type Accuracy class1) Number of load cell intervals (nLC) Max. capacity (Emax)* Minimum LC verification interval (vmin) Accuracy class C3 Temperature effect on zero balance (TK0) Accuracy class C3 kg g % of Cn / 10 K 30 5 "0.0233 50 10 "0.0280 75 10 "0.0187 100 20 "0.0280 PW16A... C3, C3MR 3000 150 20 "0.0187 200 50 "0.0350 250 50 "0.0280 300 50 "0.0233 500 100 "0.0280 50 "0.0140 660 100 "0.0212 50 "0.0106

Minimum LC verification interval (vmin) Accuracy class C3MR Temperature effect on zero balance (TK0) Accuracy class C3MR

g % of Cn / 10 K mm mV/V

2 "0.0093

5 "0.0140

5 "0.0093

10 "0.0140

10 "0.0093

20 "0.0140

20 "0.0112

20 "0.0093

Max. platform size Sensitivity (Cn) Zero balance Temperature effect on sensitivity (TKC)2) Temperature range +20 ... +40 5C [+68 ... +104 5F] 10 ... +20 5C [+13 ... +68 5F] Hysteresis error (dhy)2) Non-linearity (dlin)2) Minimum dead load output return (DR) Off center load error3) Input resistance (RLC) Output resistance (R0) Reference excitation voltage (Uref) Nominal range of excitation voltage (BU) Max. excitation voltage Insulation resistance (Ris) at 100 VDC Nominal temperature range (BT) Service temperature range (Btu) Storage temperature range (Btl) Safe load limit (EL) Lateral limit force (Elq), static Breaking load (Ed) Deflection at Emax (snom), approx. Weight (G), approx. Protection class according to EN 60 529 (IEC 529) Material: Measuring element Coating Cable sheath

600 x 600 2.0 "0.2 0 "0.1

% of Cn / 10 K

"0.0175 "0.0117 "0.0166 "0.0166 "0.0166 "0.0233 300 ... 500 300 ... 500 5 0 ... 12 15 >2 10 ... +40 [+14 ... +104] 10 ... +50 [+14 ... +122] 25 ... +70 [13 ... +158] 150 300 300 < 0.5 1.8 IP67 Aluminum Silicone rubber PVC

% of Cn

V G C [F]

% of Emax mm kg

* For max. capacities 30kg, 50kg: OIML certificate in preparation 1) In accordance to OIML-R60 with P LC = 0.7 2) The sum of data for Non-linearity, Hysteresis error and TC Span meets the requirements of OIML R60. 3) Eccentric error according to OIML R76 class.

HBM

B2192-1.0 en

Wiring code
Connection wirh 6 wire cable (selectable cable length: 1.5 m; 3 m; 6 m, 12 m) Detailed description of the Pancon plug (CE100F26-6), 6-pole
Shield (yellow) = Shield connected to load cell body Wrap connection 1 (white) = Signal (+) Wrap connection 2 (red) = Signal () Wrap connection 3 (black) = Excitation () Wrap connection 4 (blue) = Excitation (+) Wrap connection 5 (green) = Sense (+) Wrap connection 6 (grey) = Sense () blue marking

B2192-1.0 en

HBM

Ordering codes

Modifications reserved. All details describe our products in general form only. They are not to be understood as express warranty and do not constitute any liability whatsoever.

Hottinger Baldwin Messtechnik GmbH

B2192-1.0 en

Im Tiefen See 45, D-64293 Darmstadt, Germany Tel.: +49 6151 803-0 Fax: +49 6151 803 9100 Email: support@hbm.com Internet: www.hbm.com

Você também pode gostar