Form 10.1. Installation checklist: Media filters Client name: Completed by: 1.

Type of media filter: Single pass: Sand Recirc"lating: Sand#gra$el Foam Foam Reference #: Permit(s) #: Time: Peat Te%tile t!er: Peat t!er: t!er: t!er:

Date:

Comments:

Tric&ling filter: 'ra$el Plastic (pflo) filter: Sand#gra$el *ood c!ips 'eneric Proprietary +an"fact"rer: +odel: +an"fact"rer assembled Contractor assembled ,. -%ca$ation a. Sta&e location b. c. d. e. f. g. /erify ele$ations 0ottom ele$ation: *ater present in e%ca$ation 3f yes4 de)atering performed: 0ottom of e%ca$ation graded to specifications 0ottom of e%ca$ation stable 0edding material: Dept! in.

.es .es feet .es .es .es .es .es .es 12 12 12 12

0edding stabili5ed#compacted +et!od of compaction:

!. 6.

Recirc"lation berm installed *ood t!er: Concrete Fiberglass Plastic

.es

12 P/C

Container#liner: a. b. c. d.

Rigging and lifting according to man"fact"rer Container#liner )atertig!t +o"nting pad or anti7floatation flange installed Temporary or permanent bracing installed Filter drainage systems (nder7drain medi"m: Contractor7assembled

.es

12

.es .es

12 12

8. a. b.

+an"fact"rer7assembled .es 12

(nder7drain piping installed Pipe diameter: Slot opening )idt!: Slot spacing: Slot orientation: 3nternal p"mp basin installed le$el and pl"mb

c.

.es

12

d.

(nder7drain perforates container#liner Proper )atertig!t boot#fitting installed Proper )atertig!t gl"e 9oint made e. S"b7aeration piping installed P/C Polyet!ylene Constr"ction: +an"fact"rer7assembled Contractor7assembled rifice spacing: rifice diameter: rifice orientation:

.es

12

Comments:

.es

12

:.

+edia a. +an"fact"rer7assembled +edia placed into container#liner properly Properly compacted b. Contractor7assembled Specification met Proper !andling d"ring transport to site Properly stored Properly placed into container#liner Properly compacted

.es 12 .es

12

;.

0ac&fill proced"res a. +aterial: b. c. d. e. 2nti7floatation meas"res installed 0ac&fill placed in le$el lifts e$en )it! media 0ac&fill properly compacted Side)all ins"lated. Type: .es .es .es .es .es .es 12 12 12 12 12 12

<.

-lectrical installation a. Cond"it#9"nction bo%(s) installed b. Connections#penetrations properly sealed and )atertig!t

=.

-ffl"ent distrib"tion: a. Distrib"tion met!od: Press"re distrib"tion i. P"mp ii. b. Sip!on 'ra$ity distrib"tion

.es .es .es 2cti$e Compressor 0lo)er /ent"ri .es .es 12 12

Distrib"tion met!od installed Passi$e 2spirator

>.

/enting#2ir s"pply: a. +et!od "sed Free air Fan b. c.

2ir filter#screen installed /ent piping sloped to)ards media filter

1?. Co$er a. Type of co$er: b.

Free access

0"ried

@id .es

Comments:

Co$er conforms to design i. Type ii. Dept! iii. Cro)ned

.es .es .es .es .es .es

12 12 12

c. d. e.

@id sec"red Distrib"tion component accessible Filter protected from storm)ater flo)

11. 3ns"lation of access points a. +edia filter lid ins"lated by man"fact"rer Type of ins"lation: b. 2ccess riser lid(s) ins"lated i. Contractor7assembled +an"fact"rer7assembled Type of ins"lation: ii. 3ns"lation does not interfere )it! internal electrical or piping components 1,. 2dditional tas&s for tric&ling filters a. P"ll tet!ers attac!ed to all p"mps P"ll tet!er strengt! adeA"ate for tas& b. c. d. P"ll tet!ers to p"mps sec"red properly

12 12

.es

.es .es .es

12 12 12 12 12

-ffl"ent recycle p"mp piping installed to primary tan& inlet .es Sl"dge ret"rn p"mp piping installed to primary tan& inlet .es .es

16. +an"fact"rer#generic installation proced"res follo)ed: Specify if necessary:

18. a. b. c.

Site stabili5ed after constr"ction: -rosion control meas"res in place Site loamed#topsoil dressed4 seeded4 and#or m"lc!ed Finis! grading and landscaping being done by ot!ers

.es .es .es 12 12

d.

)ner ad$ised of landscaping preca"tions