Você está na página 1de 76

A3.

HDCS Fiber Solution


Rosenberger Asia-Pacific Sales & Marketing Dept. 2010.

HDCS Fiber SolutionManufactory

Germany

Shanghai

Hungary

Brazil

Contents
1, What is Fiber 2, About SM/MM Fiber 3, HDCS Fiber Solution 4, HDCS Example

HDCS Basic-About Fiber


The application of Fiber

Telecoms
Video & Videoconferencing

E-mail Databases HDTV Fax

Computing
CD-I

INTERNET INTERNET

Virtual reality Multi-media

Video
Consumer Electronics

HDCS Basic-About Fiber Advantages of Fiber


1. 2. 3. 4. 5. 6. 7. 8. High Bandwidth Low Attenuation No Crosstalk No EMI No need for Grounding Safety Easy Upgrade Green

HDCS Basic-About Fiber

What is Fiber? How can light transmit inside?

HDCS Total Reflect


Total Reflect when n1 sin 1 = n2 sin 2

Refracted

n2 n1

1 1
Critical Angle Total reflect

incidence reflect

HDCS Structure of Fiber

CORE FunctionTransmitting light Materialgermanium-doped silica CLADDING FunctionTotal Reflect MaterialPure Silicon Glass COATING FunctionProtect Fiber MaterialPolyacrylates or Silicon
Core 9/50/62.5/100um Cladding 125 um Coating 250/400 um

HDCS How can Light transmit in Fiber


Total Reflect
Air Cladding n2

Acceptable incidence angle (max)

Core n1

n1 > n2 max = 2sin-1(n12-n22)1/2 NA = (n12-n22)1/2 NA = sin(1/2 max ) (Ex. n1 = 1.47 n2 = 1.46 (Silica glass fiber))

How to make Fiber


Step1. Make Glass Club Chemical Reaction 1 (MCVD Lucent)
SiCl4 + 2O2 GeCl4 + 2O2 SiO2 + 2Cl2 GeO2 + 2Cl2

Chemical Reaction 2 (OVD Corning, VAD Japan)


SiCl4 + 4H2 + 2O2 GeCl4 + 4H2 + 2O2 SiO2 + 2H2O + 4HCl GeO2 + 2H2O + 4HCl

Plasma Chemical Vapor Deposition PCVD (Philips)

How to make Fiber


Tube Glass Silicon Tube Waste gas Cl2

SiCl4, GeCl4, O2

Reaction

Deposition of particle SiO2, GeO2

MCVD
H2, O2

How to make Fiber


MCVD

How to make Fiber

VAD
Pulling or Rotating Wasted Gas

Glass Club

Fritted Glass

Reaction

SiCl4, GeCl4 , H2, O2

How to make Fiber

VAD

How to make Fiber


Step2. Make Fiber By Dropping
Heat To 2000C Glass Club

Coating Selection Tray Filling

Tightly

About Fiber Connector


Physical Contact
Tangent line

Sphere
Fiber

Sphere

The Ferrules of two Fiber connectors only contact


at the Tangent Line between two Spheres

About Fiber Connector


Fiber

Tube

Spring

Ceramic Ferrule Top of Ferrule R5 25 mm

About Fiber Connector


APC Connector has an angle to let the reflect light out of the fiber,

and improving the return loss performance

8/9

About Fiber Connector What makes a Bad connection


Fiber end faces should be free of any contamination or defects, as shown below:

Common types of contamination and defects include the following:

Dirty

Oil

Pits and Chips

Scratch

Contents
1, What is Fiber 2, About SM/MM Fiber 3, HDCS Fiber Solution 4, HDCS Example

HDCS Structure of Fiber-SM/MM


100X Picture of Fiber
50or62.5 m 9 m

125 m

125 m

Multimode

Single Mode

What is LightTransmission Mode


2 E ( z , t ) = E 0 sin z t
y
Ex Phase F Amplitude E0

Electric FieldE
x z
Wavelength l

Magnetic FieldH

HE11/TEM10 Mode Single Mode

About Size of SM and MM

SM 9.3 m Mode-Field 125 m Cladding 250 m Coating OS1/OS2 Attenuation: <= 1.0dB/km @1310nm & 1550nm

MM 50/125um 50 m Core 125 m Cladding 250 m Coating OM2/OM3/OM4 Attenuation: OM1/OM2/OM3/OM4: <= 3.5dB/km@850nm <= 1.5dB/km@1300nm

MM 62.5/125um 62.5 m Core 125 m Cladding 250 m Coating OM1

Lager cores and lower wavelengths driver source and system costs down

Different Index type of Fiber


1.458 1.472

Input Pulse

Stepped Index

Output Pulse

Graded Index

Stepped Index (SM)

1.462

refractive index

Modal Dispesion of MM Fiber MultiMode


Light Signal(pulse) travels along many modes or paths. Pulse Spreading occurs due to Modal Dispesion, Called DMD(Differential Mode Delay) Pulse Spreading Limits BandWidth(Transmission Carrying Capacity)

Excessive Pulse Spreading=Inter-symbol Interference (ISI)= Bit Errors

Minimum the DMD


Pulses of Light Traveling Through Multimode Optical Fiber

Excessive Modal Dispersion

Minimum Modal Dispersion

This is the difference between OM2 to OM3/OM4

Bandwidth of different MM Fiber


FOL BW=Overfilled Lannch Bandwidth EMB = Effective Modal Bandwidth (Laser-Optimized)

EMB met by meeting: a) DMD specifications, b) EMBc

Reach and Bandwidth of MM Fibers

MultiMode Light Distance Support

Single Mode Fiber SingleMode


Eliminates modal Dispersion Takes advantage of lower attenuation at longer wavelengths(1310&1550nm) Enables tremendous transmission capacity over very long distances

Small Core guides only one mode

Attenuation and Wavelength

Normal OS1 fiber


Attenuation

LED / VCSEL

LASER DIODE

500 600 700 850 900 1000 1100 1200 1310 Wavelength (nm)

1400 1550

Attenuation and Wavelength


OS2 Zero/low water Peak
Rosenberger OS fiber Eliminate water peak at 1383nm
Attenuation

LED / VCSEL

LASER DIODE

500 600 700 850 900 1000 1100 1200 1310 1383 1550 Wavelength (nm)

MultiMode Light Distance Support

Standards About Fiber


Application (IEEE,IEC)
1000BASE-LX1000BASE-SX10GBASE-SR10GBASE-LRIEC 14165- 111: Fiber Channel

Physical Link (cabling)


ISO 11801TIA/EIA 568C.3

Components (Fiber, Connector


IEC 60793-2-10IEC 61754G.652-G.657

Testing Method
IEC 60793-1TIA -455, FOTP-204, FOTP-220

Contents
1, What is Fiber 2, About SM/MM Fiber 3, HDCS Fiber Solution 4, HDCS Example

HDCS Fiber SolutionFTTD All Fiber Solution


Crimp Fiber Connector FTTD Fiber Faceplate Wall Mounted

Fiber connector and Pacthcord

19EIA Fiber Panel

Trunk Cable

HDCS Fiber Solution All Fiber Solution


Campus/backbone/horizo ntal Fiber Cable FTTD Faceplate

Trunk 19 Fiber Panel Pigtail and pacth cord Wall Mounted Crimp connector

HDCS Fiber Solution-Products Fiber Connector and Patchcord


Rosenberger Can provide many types of fiber connector

SC/PC

ST

MT-RJ

FSMA

DIN

SC-APC

ESCON

FDDI

FC-APC

FC-PC

E-2000

MU

MU APC

MTP

LC/PC

LC/APC

HDCS Fiber Solution-Products Fiber Patch cord and Pigtail

100% Performance test Interferometer testing, quality guarantee Follow IEC, EIA, Telcordia / Bellcore standard SM,MM,OM3 types optional OFNROFNPLSZH Fire Retardant level

HDCS Fiber Solution-Products Adaptor


Features: SM,MM optional Plastic / Metal Shell optional Simplex or Duplex Hybrid adaptor

HDCS Fiber Solution-Products Traditional Fiber Splicing Solution


Splice Box Splice tray
Pigtail

Fiber management Fiber Cable

Long time installing Special tools and equipment Training necessary

HDCS Fiber Solution-Products Fiber Trunk Cable


Trunk Cable is pre-installing the connectors in Manufactory on both sides of Fiber cable based on the requirements as what type of connector and the length of fiber cable. And also add special high strength protection Accessories Protection Tube indoor / outdoor

Trunk Cable

HDCS Fiber Solution-Products Structure of Trunk Cable

Fiber Cable

Bare Fiber

Preconnect Fiber

Patent trunk technology

No Splice point 100% Manufactory install 100% Performance test Tools free Easy install

HDCS Fiber Solution-Products

Trunk Cable With


Prefect protection

Normal Fiber + Splice + Pigtail + Field Testing + Re-Splice + Easy install + Safety + Easy Maintenance

HDCS Fiber Solution-Products


Why we need Pre-connect Technology:

1) Saving Investment: Protect the owner's right to know, avoid wasting and investment risk 2) Easy install, saving time: Plug and Play 3) Stable and reliable: 100% Manufactory performance test, only need continuity test after installing 4) Perfect protection: No splice point and Bare fibre in air, avoid aging problem 5) Easy maintenance: Nice mechanical character, avoid damage Fiber During maintenance 6) Reinstallation: Trunk Cable is easy moving and safety plug and reinstall.

HDCS Fiber Solution-Products


Work effor for established splice soultion:
Cabling laying 100m route, 2 persons 1 hour

Splicing incl.ancillary works and measuring 48 Fibers: 8 hours

Totally

9 Hours

Work effor for Preconnector trunk:


Cabling laying 100m route, 2 persons 1 hour Application of plug connectors,installaiton of disgributor housings and light function test, 2 persons: 0.75 hours

Totally: 1.75 Hours

Splicing

Preconnector

HDCS Fiber Solution-Products

Installation of trunk cable on distribution


Special Design slot on distribution Resistance force from pulling and rotating Fast installation

HDCS Fiber Solution-Products


Order And Install Trunk Cable Notes:
Order: Calculate the length of distance between racks and plus the length of trunk cable in racks (normally 4-8 meters). Install: Follow normal installing standard, trunk cable can afford 50N pulling force, care inner size of tube while design.

HDCS Fiber Solution-Products

Features:
Indoor / outdoor design Mouse proof optional IP67 for outdoor cable,IP50 for indoor cable From 6 to 144 cores Afford 500N pulling force Easy reinstalling and maintenance

HDCS Fiber Solution-Products

Features
OM1,OM2, OM3, SM LSZH or PE material coat Different types of connector based on requirements as: MT-RJ, MPO, SC, FC, ST, E2000, LC, MU, DC.etc. Customer Design length of trunk cable

HDCS Fiber Solution-Products

Trunk cable installing

HDCS Fiber Solution-Products


Fiber Cable
Different types: Indoor/outdoor, FTTD Following IEC60794-2, IEC60794-3 standard Performance better than IEC11801, EIA568B and EN50173 requirements All SM fibers are G.652D low water-peak Fiber OM3 available UL Certification

HDCS Fiber Solution-Products


How to choice fiber cable
Application: Environment: indoor, outdoor, patch cord Buried , Pipeline , mouse proof

Fire Retardant (indoor): OFNRRiser), OFNP (Plenum), LSZH Buffer type (indoor): tight, semitight, loose Fiber type: Bandwidth: Mechanical: Temperature: Numbers of cores 50/125um, 62.5/125um, 9/125um, OM3 50/125um OM1(200/500), OM2(500/500), OM3(2000/500) Pull strength, Bearing force, Bend Radius working/installing temperature

HDCS Fiber Solution-Products

NEC & UL1651 Fire Retardant level for Indoor Fiber Cable OFNR: Riser Level, prevent the spread of fire from difference floors , follow UL1666 standard. OFNP: Plenum level, Fire Retardant and low smoke, normal using in under floor or ceiling, follow UL 910 standard. LSZH: Low Smoke Zero Halogen, follow 60332-1/3, 60754-2, 61034-2 standard,

HDCS Fiber Solution-Products

Indoor Fiber patch cord


a) Simplex Fiber

b) Duplex Fiber

c) Multi-core with coat

HDCS Fiber Solution-Products


Indoor Trunk cable
a) Indoor Backbone Trunk cable inner fiber diameter 0.9mm

b) Indoor Multi-core turnk cable inner fiber diameter 2mm

HDCS Fiber Solution-Products


Indoor/outdoor common cable
Central tube /Loose Tube Layer Stranded non-metal FRP Central strength enhance KEVLAR/GLASS Non-Metal thermo-plastic loose tube Vertical water resist Mouse proof LSZH or PE coat Max. 12x12 cores

HDCS Fiber Solution-Products


Fiber distribution
Both for Trunk and Splice solution Fixed or Drawer design 1HU for 24(48*) cores installation 2HU for 48(96*) cores installation Different types of panel for Different adaptors as SC-Duplex, ST, E2000, MTRJ, LC-Duplex, MU-Duplex, FC Accessories for Splice

HDCS Fiber Solution-Products


Wall mounted Fiber Distribution
Features: Both for Trunk and Splice solution SC, FC, ST, LC connector optional 12, 24, 48 core optional Double Hinge Turing cover design ,easy for installation Build in lock for safety Meet ROHS requirements

HDCS Fiber Solution-Products


FTTD solution---Field Polishing Connector

Advantage: Only need normal fiber connector, low cost Disadvantage: Special equipment, professional engineer, long time, no guarantee for installation

HDCS Fiber Solution-Products


FTTD solution---Field Splice

Advantage: Pigtail Splice, guarantee the connection Disadvantage: Special equipment, professional engineer, long time, weak of splice connection need special protection

HDCS Fiber Solution-Products


FTTD solution---Field Cramp Connector
SCSTLCMTRJ, etc. connectors optional Follow ANSI/TIA/EIA-568-B.3 standard Fast installing Low cost, no need for polishing 0.4dB insert loss for SM 0.3dB insert loss for MM

HDCS Fiber Solution-Products

Structure of Field Crimp connector

HDCS Fiber Solution-Products


Outlet of FTTD
Suitable for SC simplex/duplex, ST, LC Duplex and MTRJ connector Humanized Design turning dust cover 45Outlet suitable both Fiber adaptor and Copper connector For standard 86x86 mounted

HDCS Fiber Solution-Products


Indoor armored fiber patch cord NEW!
Feature: 1. For FTTD patch cord 2. Metal-armored inside 3. anti3000N/100mm 4. Bearing force >200N 5. Flexible and stabile 6. LC, SC, etc. connectors

Contents
1, What is Fiber 2, About SM/MM Fiber 3, HDCS Fiber Solution 4, HDCS Example

HDCS Example
Beijing Capital Airport T3

Project: Cat 6 and OM3 cable Voice/data point: 12000 FTTD point1500

HDCS Example

Project Cat 5E/Cat 6 and SM cable Voice/data point23000

HDCS Example

HDCS Example

HDCS Example

HDCS Example

HDCS Example

Air Bus Cabling

HDCS Cabling Solution

1. 2. 3. 4. 5. 6.

One-Stop Total Solution Quality Guarantee Training and Consulting Quickly and flexible delivery Fast Action Good performance-price ratio

Thank You

Você também pode gostar