BusinessCase
30Windturbinesareassembledforstandardtemperatureversion(STV) Assess canweusetheseturbinesinlowtemperatureversion(LTV)? Assess, ForUTS,0.2%Proofstrength,%elongation,thoughspecificationsare differentforLTV&STVbutfromactualtestreportsassessmentcanbe d done f forqualification lf toLTV ForSTVimpactischeckedat20C&forLTVimpactischeckedat40C UTS,0.2% UTS 0 2%Proofstrength&%elongationarecheckedinsamemannerfor STV<V Canwearriveatroughestimatedimpactvalueat40Cfortechnical decisionmaking?
Define
ProjectName Objective Benefits
AbdullahAnsari(ASQCSSBB)
Schedule
Measure 24Jan2013
Analyze 27Jan2013
Improve
Control
Measure:TestProgram g
PlannedActions
Measure:TestData
Analyze: y Relationship p
Analyze: y Relationship p
Signal: Impactvaluedecreasesastesttemperaturedecreases At20:MaxImpact14.43atelongationof23.6%&MinImpact10.5atelongationof17% At40:MaxImpact8 8.5 5atelongationof21 21.7% 7%&MinImpact5 5.1 1atelongationof20 20.6% 6%
Improve p :FactorAnalysis y
Control:ValidatetheEquation q
Outof14actualimpactvaluesat40,3doesnotmatchverycloselywithresultof regressioncalculation&11actualvaluesmatchwithin1Joule
9
Way yForward:Recommendations
10
ActualDatawithcalculatedestimateofimpactat40degree
11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 Impact@20degree CalculatedImpact@40degree
12
13
ThankYou
14