Practix 300 Specifications

Practix 300
With its swiveling telescopic tube arm
and rotatable column, the Practix 300
adds a new and outstanding dimension
to mobility. Optimal positioning can be
achieved as easily as with a stationary
Bucky system. Various features and
options allow the unit to be used for wide
ranging applications in all fields of
radiography.
Changing its point of view
comes naturally
Practix
Mobile Radiography
4522_981_91321.qxd 8/4/04 2:51 PM Page 6
Mobility from
head to toe
Easy handling and positioning
The easy maneuverability of the Practix 300 allows
X-ray exposures to be made wherever needed.
With its smooth running wheel system and small
footprint, Practix 300 provides outstanding
mobility. The Practix 300s swiveling telescopic
tube arm and rotatable column allow the tube to be
positioned quickly and easily, whether the unit is
situated at the foot or the side of the bed.
Applications
Short exposure times prevent motion artifacts,
with high peak power and mAs producing images
of excellent quality. This allows the Practix 300
to be used for a wide range of applications and is
particularly suitable for taking X-rays of patients
in emergency rooms and for use with thorax
exposures. 36 APR programs make working easier
and faster. Additionally available options are remote
control, high-resolution X-ray tubes with different
focal spots and dose area product measurement
(Diamentor PX).
Digitalization
As with all members of the Practix family, the
Practix 300 can be upgraded to digital by adding
CR (Computed Radiography) cassettes, providing
a lighter and more compact alternative to a digital
flat detector.
Due to its geometry with rotatable column and swiveling telescopic
tube arm, both beds are easily accessible without the need to reposition
the basic system.
4522_981_91321.qxd 8/4/04 2:51 PM Page 1
Technology
you can rely on
Basic unit
Type Mobile X-ray unit with rotating column (200) and telescopic X-ray tube arm
Dimensions in mm (l x w x h) 1120 x 617 x 1925 (44.13" x 24.31" x 75.84")
Cassette storage Radiation protected for up to 10 cassettes (43 cm x 43 cm)
Source-floor distance 70 cm to 200 cm
Weight 290 kg (639 lbs)
Generator
Type High-power X-ray generator
Peak power 30 kW (100 kV / 20 ms) at 230 V / 115 V (mains voltage)
Nominal power 22 kW (100 kV / 100 ms) at 230 V / 115 V (mains voltage)
Tube voltage 40 kV to 125 kV in 1 kV steps
Maximum current 300 mA
Tube current time product:
large focal spot 0.1 mAs to 200 mAs
small focal spot 0.1 mAs to 64 mAs
Mains supply 115 V 10%, 230 V 10%, single-phase, 50 Hz (60 Hz)
Mains fuse 16 A slow
Preparation time 1s
Exposure times 1 ms to 5.3 s
X-ray tube
Type Rotating-anode X-ray tube
Anode material Rhodium,Tungsten, Molybdenum
Nominal focal spot 0,6 / 1,5 or 0,6 / 1,2 (option)
Anode angle 14
Maximum radiation field 43 cm x 43 cm
Options
Dose area product measurement (Diamentor PX)
Remote control
Pediatric filters
4522_981_91321.qxd 8/4/04 2:51 PM Page 2
730
880
2000
1
0
0
0

1
9
2
5
1
0
9
5

7
0
0
3
8
0
3
6
0

6
1
7
820
1180
2
0
0
0

360
1120
On release of break
lever, unit stops
immediately
Radiation protected
cassette drawer for
up to ten cassettes
User interface for
full system control
including all options
The dimensions
of maneuverability
All dimensions in mm
4522_981_91321.qxd 8/4/04 2:51 PM Page 3
Even within reach from the beds
foot end
Lateral exposure
in emergency environments
Digitalization via Philips
Computed Radiography
4522_981_91321.qxd 8/4/04 2:51 PM Page 4
Asia
Tel: +852 2821 5888
Europe, Middle East, Africa
Tel: +31 40 27 63005
Latin America
Tel: +55 11 2125 0764
North America
Tel: +1 425 487 7000
Koninklijke Philips Electronics N.V. 2004
All rights are reserved. Reproduction in whole or in
part is prohibited without the prior written consent
of the copyright holder.
Philips Medical Systems DMC GmbH reserves the
right to make changes in specifications and/or to
discontinue any product at any time without notice
or obligation and will not be liable for any conse-
quences resulting from the use of this publication.
Printed in The Netherlands.
4522 981 91321/704 * JUL 2004
Philips Medical Systems is part
of Royal Philips Electronics
Interested?
Would you like to know more about our
imaginative products? Please do not hesitate to
contact us. We would be glad to hear from you.
On the web
www.medical.philips.com
Via e-mail
medical@philips.com
By fax
+31 40 27 64 887
By postal service
Philips Medical Systems
Global Information Center
I.B.R.S./C.C.R.I. Numro 11088
5600 VC Eindhoven
Pays-Bas/The Netherlands
(no stamp required)
4522_981_91321.qxd 8/4/04 2:51 PM Page 5