design guidelines and considerations

building types

strictly residential (single detached)


Identify owners requirements and wish-list

Users profile

Special treatment regarding spaces concerning environmental factors

residential

subdivision planning
Consider lot size given for apportioning Roadway system shall be double loaded type provide buffer trees on the perimeter fronting a source of nuissances follow design standards set by authorities

meandering raodways create more interest

residential

apartments/ townhouses/ walk-up condominiums


Cluster arrangements are preferred consider utilities and services like the use of meter banking electrical room, fire exits and suppression system, vertical transport, laundry areas, water tanks etc. follow design standards set by authorities

hallways must be adequate

residential

offices
Consider nature / function/ services of the office

Open planning concept is OK


Most economical ratio 70% rentable space 30% circulatory/ service areas Problem specific situations must be carefully analyzed If basement parking is required, take note of density requirements

commercial

banks
The vault shall be so located at the most secured independent spot within the building The managers cubicle/ office shall be near the public area

Define banking floor and clerical area


Straightforward circulation Security is priority

commercial

hotels
Guests needs always first Guest rooms must be provided with adequate facilities

Internal T&B for guest rooms OK, Bed areas must be adjacent to area with window
Kitchen areas must be accessible to function areas 60% dining, 40% kitchen Provide adequate BOH area away from public view

Business center and concierge must be accessible from all points


Hospitable atmosphere for the whole setting

commercial

cinema
Sightlines in relation to the screen and seating configuration 60 cone of vision Fire protection system and exits must be equally distributed

Acoustical treatment and lighting system


Active ventilation

commercial

recording/ sound studio


Acoustical treatment Apply the principle of box within a box

Cotrol booth with sound equipments


For dubbing studio provide projector room and screen with sound effects pit No walls are perpendicular to each other

Floor must be raised floor system

commercial

shopping center
Every square inch counts Display of merchandise

Space configuration to maximize foot traffic


Ample parkings slot available Service and delivery system

Convenient circulation and wayfinding

commercial

Seaports/ Airports
Passenger and cargo traffic must be segregated Terminal building must be provided with appropriate facilities

Coast guard office / Air Transportation Office is required, provide it with communication facilities Land transportation access must be included
Passenger concourse and waiting area must be adequate especially during peak season

commercial

manufacturing- large scale industry


Eco-environmental considerations in terms of its emitted pollutants Buffers zones are very essential

Roadways must accommodate movement of large vehicles and equipment


Site zoning must be clearly established: Administrative, Production, Storage, Prohibited, Utilities Safety features must be included

industrial

factories
Eco-environmental considerations in terms of its emitted pollutants Internal zoning must be established: Color coding of areas are preferred to monitor flow

Catwalks can be provided for systems supervisor


Clinic must be near production area Loading and Unloading zones for raw and finished products must be properly located in relation to storage facilities Pollutants must be checked

industrial

shipyards/ hangars
Stockyard for materials must be large enough to accommodate volume of materials Check dimensions of ship/ aircraft- space must accommodate different models Repair sheds should have ample structure height

industrial

schools
Identify primary users profile Consider the 3 major components of the academe: Instruction, research, and extension

Lecture room size as per DepED/ CHED requirements: 7m X 9m for 40 students Provide ample circulation facilities
Safety and security measures

institutional

research laboratory
Holding area of specimens Safety and security measures

Provision of work stations and technical library


Records vault and surveillance system Databank location

institutional

library
Determine book holdings Use of ICT features

Provide book repairs and work area


Ample storage facilities Dumbwaiter for multi floor libraries

Ample light and ventilation

institutional

museum
Circulation system/ flow of viewers Vault of priceless collections

Curatorial spaces
Workshop area for repair, restoration and maintenance of artefacts Flexible service entrance for large materials

Safety and security

institutional

city hall / civic center


Application of all laws and provisions on design and construction Heavy public oriented/ transactional areas must be on the ground floor

Linear flow of civic services


Flagpole and assembly area Recreational facilities

institutional

hospital
Strict zoning of areas- sterile/ non sterile, private/ public, quiet/ noisy Relationship of major divisionsOPD/ Emergency/ Clinical/ Surgical/ Wards/ Administration/Ancillary Centralized Planning

institutional

fire station
Importance of the apparatus floor Hose tower

Quarters and living areas


Administration and night watch Equipment storage and facilities

institutional

embassy
Delineation of consular affairs, attaches portfolio office and ambassadorial Security and evacuation features

Quarters and residential units


Public spaces, presence of flagpole Image, character

institutional

penitentiary
Classification of areas by concentric arrangement construction Security/ surveillance features

Recreational/ occupational areas


Humane environment

institutional

police station
Booking counter Armory must be near office of station commander

Safety and security features


Cell separation

institutional

Sports Facilities
climate conditions population of players, expectators, and support persons availability of land and site safety

surfacing of the play areas

parks
openness free flowing movement segregation of areas of different activities and features landscaping and way finding elements