Você está na página 1de 4

1|P ag e

SINGLE RELAY BOARD

An ISO 9001-2008 Certified Company Order Code RDL/SRB/13/001/V1.0

Single Relay Board


The board has only one relay driven by TTL circuit. The board works on 12V but the input signal can come directly from microcontroller output working at 3V or 5V to control relays. Each relay can switch varierty of AC or DC high voltage, high current loads working at 110V or 220V AC mains like lights, fans, motors and such. The status of relay is indicated by individual LEDs.

Features
LED indication of relay on and power. Design based on highly proven TTL as driver. AC or DC operating voltages. No leakage current.

Applications LED series and parallel connections. Relay drive from external contacts.

Specifications
Parameter Operating Voltage Current Value +12v dc 8A

www.researchdesignlab.com

2|P ag e
SINGLE RELAY BOARD

An ISO 9001-2008 Certified Company Order Code RDL/SRB/13/001/V1.0

Pin Details
Pin 1 2 3 Name gnd V+ R Details Power supply ground +12v +5v

Working
A relay is an electrical switch that opens and closes under the control of another electrical circuit. In the original form, the switch is operated by an electromagnet to open or close one or many sets of contacts. It was invented by Joseph Henry in 1835. Because a relay is able to control an output circuit of higher power than the input circuit, it can be considered to be, in a broad sense, a form of an electrical amplifier.

Sugar Cube Relay

Despite the speed of technological developments, some products prove so popular that their key parameters and design features remain virtually unchanged for years. One such product is the sugar cube relay, shown in the figure above, which has proved useful to many designers who needed to switch up to 10A, whilst using relatively little PCB area.

www.researchdesignlab.com

3|P ag e
SINGLE RELAY BOARD

An ISO 9001-2008 Certified Company Order Code RDL/SRB/13/001/V1.0

Since relays are switches, the terminology applies switches is also applied to relays. A relay will switch one or more poles, each of whose contacts can be thrown by energizing the coil in one of three ways:

1. Normally - open (NO) contacts connect the circuit when the relay is activate d; the circuit is disconnected when the relay is inactive. It called a FORM A contact or make contact. is also

2. Normally - closed (NC) contacts disconnect the circuit when the relay is activated; the circuit is connected when relay is inactive. It is also called FORM B contact or break contact.

3.

Change-over

or

double-throw

contacts

control

two

circuits;

one

normally open contact and one normally closed contact with a common terminal. It is also called a Form C transfer contact.

Sample Application
To view sample code and schematic click the below link: http://researchdesignlab.com/index.php/interfacing-board/single-relay-board.html

www.researchdesignlab.com

4|P ag e
SINGLE RELAY BOARD

An ISO 9001-2008 Certified Company Order Code RDL/SRB/13/001/V1.0

Board Dimensions
60mm

20mm

To buy this product click the below link http://researchdesignlab.com/index.php/interfacing-board/single-relay-board.html

www.researchdesignlab.com