Você está na página 1de 14

STRUCTURAL CALCULATION ESSEN WELDING SHOW

PR STRUCTURAL DESIGN: Sinisa Marjanac msce www.ekons.ba CLIENT: VENUS WIRES

STAND: VENUS WIRES

TABLE OF CONTENTS 1.
1.1 1.2 1.2.1 1.2.2 1.2.3 1.3 1.4

INTRODUCTION
ARCHITECTURAL INPUTS LOAD ANALYSIS DEAD LOAD HORIZONTAL LOAD LOAD COMBINATIONS STRUCTURAL MODEL STRUCTURAL DESIGN

2
2 4 4 4 4 5 7

2.

DRAWINGS

VENUS WIRES Stand, Messe Essen

1.

INTRODUCTION

The stands has to be designed for Fair Trade in Essen, Germany. Area is 9 x 4,6m, height is 2.8m 5m. Walls are made by plywood sheets and glass, strengten with maxima aluminum and timber profiles. 1.1 ARCHITECTURAL INPUTS

VENUS WIRES Stand, Messe Essen

VENUS WIRES Stand, Messe Essen

1.2

LOAD ANALYSIS

Stand construction safety1


Stands, including all equipment and exhibits and advertising matter are to be constructed with such stability as to pose no danger to public safety and order, and in particular to life and health. The exhibitor is responsible for structural safety and must provide proof of this. Free-standing structural elements and special structures (e.g. free-standing walls, high exhibits, high decorative elements) which can fall over must be rated at least for a horizontally acting equivalent distributed load qh: qh1 = 0.125 kN/m2 up to 4.00 m high from the upper edge of the floor qh = 0.063 kN/m2 for all surfaces above 4.00 m high. The respective elevation area is the reference area. The relevant verifications to be prepared are to be submitted to MESSE ESSEN GmbH in a form that can be examined. Approval of stand construction On the assumption that the technical regulations have been observed in the design and construction of the stand, there is no requirement for submission of drawings for approval in respect of single-storey stand structures up to 2.50 m in the halls. 1.2.1 DEAD LOAD MATERIALS
Assumptions/Conversions Plywood Sheets: BxL=2500 x 1000 mm, Thicknes: 9.5 mm Mass per sheet: 11,85 kg Timber D70 bxh = 8 x 8 cm 80 x 80 mm Loading L1 = 0.0474 KN/m2 L2 = 0.0512 KN/m1 0.005 KN/m1

Timber Maxima Aluminum 2 Equipment Lights

L3 = 0.05 KN/m1

1.2.2 1.2.3

HORIZONTAL LOAD
Wind load 1: WL=0.063KN/m2

LOAD COMBINATIONS COMB1: 1.35DL +1.50 WL1

http://www.schweissenschneiden.com/en/schweissen___schneiden/fuer_messebauer/standsicherheit___standbaugenehmigung/standsicherhei t_standbaugenehmigung_1.html
2

Supplier: http://newkangjia.en.alibaba.com/productgrouplist-200632408/Maxima_system.html or equivalent

VENUS WIRES Stand, Messe Essen

1.3

STRUCTURAL MODEL

Geometry

VENUS WIRES Stand, Messe Essen

Dead load

VENUS WIRES Stand, Messe Essen

Wind load 1.4 STRUCTURAL DESIGN

DEFORMATION COMB1

Moments COMB 1

VENUS WIRES Stand, Messe Essen

Panel stress

OVERTURNING WALL CHECKING For 1m lenght of wall: Vertical loads: 1. Plywood (5m per 1m) 0,0474 KN/m
2 2

Horizontal loads: 1. Wind load 0,063 KN/m2 Area: 5m x 1m Fw = 0,315 KN Distance from point: H = 2,50m

2. Timber column (2x5m per 1m of wall) 0,0512 KN/m 3. Timber beam (3 per 1m of wall) 0,0512 KN/m F1 = 0.237 KN F2 = 0.512 KN F3 = 0.153 KN Distance from point: L = 0,50 m Mv = 0.902 x 0.5 = 0,451 KNm Mv MH

M h = 0.315 x 2.5 = 0,787 KNm

For stabilizing of overturning of wall it must be added aditional vertical weight on wall bottom. Moment of additional vertical weight must be: Mh - Mv = 0.787 0.451 = 0.336 KNm Moment arm is 0,25m. Total additional vertical weight per 1m of wall must be 1.35 KN. That is equivalent weight as cross section of steel plates bxh = 35cm x 6cm. ON BOTTOM OF WALL TO ADD STEEL PLATES ( 350 x 6 x 9000 mm) AS HORIZONTAL LOAD COUNTERWEIGHT! 8

VENUS WIRES Stand, Messe Essen

2.

DRAWINGS
No 1 2 3 DRAWING NAME STAND D110 Drawing 1 STAND D110 - Drawing 2 STAND D110 - Drawing 3 SCALE 1:50 1:50 NTS

1 : 50

Section B - B

Section A - A

Section C - C

1 : 100 1 : 50

PLYWOOD QUANTITY WALL W1 (timber columns) 2500 x 1000 ........... 18 pcs 2500 x 500 .............. 4 pcs WALL W2 (maxima profiles) 2600 x 1450 ........... 2 pcs 2600 x 1200 ........... 2 pcs WALL W3 (maxima profiles) 2500 x 1250 ........... 2 pcs

TIMBER QUANTITY WALL W1 COLUMNS L=5m.... 20 pcs BEAM L=4.5m..........18 pcs BEAM L=0.5m..........30 pcs FLOOR BEAM L=2.5m..........7 pcs BEAM L=1.7m..........3 pcs

MAXIMA QUANTITY OFFICE COLUMNS L=2.6m....10 pcs BEAM L=4.1m............3 pcs BEAM L=2.5m............3 pcs

1 : 100