Você está na página 1de 6

Appendix T4

SC FEPA BIRLAD

CHECK VALVE type RRC-EA

APPLICATIONS Designed for vehicular use of fluids in plants overrunning the valve to prevent returnof the role of the working environment (gas or liquid) pressure when the upstreampressure equal to or lower than the downstream or upstream from the pump suctionnozzle. The products fall into the category of accessories for pressure regulation andmeet the essential requirements for ensuring the security of users of pressureequipment covered by PED 97/23/CE Construction antistatic. API594 design Fireproof construction SREN ISO 10497 CONSTRUCTION Designed and executed in a manner that would allow use in tough conditions including operating on a wide range of fluids with varying degrees of viscosity at high temperatures. Composed of two identical bodies and seat seals, valve seals and removableelement The latter can be: either stainless steel / rubber, stainless steel / Teflon, stainless steel/ stainless steel depending on the environment and the working temperature Bodies consisting of a cylinder and two flanges are either carbon or stainless steel depending on requirements. Opening pressure value can be adjusted by the customer or variants spring counterbalanced FUNCTIONAL FEATURES Nominal diameter: 25, 32, 40, 50, 65, 80,100,125,150,200,250, 300, 350, 400, 450, 500, 600, 800 Nominal pressure: 6, 10, 16, 25, 40, 64, 100 150 cf bar table and four PG3 Maximum working fluid temperature 350 C Connection to the process flange in accordance with DN and PN and Class Vertical or horizontal mounting position In a vertical position at the entrance equipped with a filter can be used as whirlpoolpump

SCFEPASA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.1/6

Variante constructive din productia de serie

Weight adjustement

Fig 1

Spring adjustment

Fig 2

Without adjustment

Fig.3

SC FEPA SA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.2/6

RRC EA Piston SW construction

RRC EA Wafer construction

RRC EA BW construction

SCFEPASA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.3/6

Weight and dimension for flanges type(the usual


Dn 2 2 2 2 3 3 3 3 4 4 4 4 6 6 6 6 8 8 8 8 10 10 10 10 12 12 12 12 Class 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 150 300 600 900 L(mm) 203 267 292 308 241 318 356 381 292 356 432 457 356 445 559 610 495 533 660 737 622 622 787 838 699 711 838 965 D(mm) 152 165 165 216 190 210 210 241 229 254 273 292 279 318 356 381 343 381 419 470 406 445 508 546 483 521 558 610 M(kg) 14 20 27 46 27 41 47 65 43 62 87 112 75 119 167 257 162 213 290 350 223 299 475 510 297 428 637 780

SCFEPASA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.4/6

Dn 14 14 14 16 16 16 18 18 18 20 20 20 24 24 24 30 30 30

Class 150 300 600 150 300 600 150 300 900 150 150 300 125 150 300 125 150 300

L(mm) 787 787 787 787 787 787 838 838 838 864 864 864 978 978 978 1346 1346 1346

D(mm) 535 585 605 600 650 685 635 710 745 700 775 815 815 915 940 1060 1150 1195

M(kg) 880 960 1100 1170 1260 1450 1410 1500 1770 1720 1850 1980 2700 2930 3400 4900 5320 5970

SCFEPASA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.5/6

Codificare

RRC-EA

x a

Coding level Nominal Diameter Enter a nominal value or NPS

b ... . c 1 2 3 d 1 2 e 1 2 3 f 1 2 3

Nominal pressure(or class) Enter value Fluid temperature -20 +100 C +10 +200 C +30C +350C Body material Otel carbon Otel inox Opening adjustment without With weight With spring Seal type Ss/ruber ss/PTFE ss/ss Type Wafer Flanges BW Construction 1 2 Disc Piston

SCFEPASA Str Republicii nr 316 731120 BIRLAD

tel 0235/415990;41466 Fax 0235/421618;413729 E-mail :fepa@fepa.ro

SG RRC-EA 831/2008 rev.1 pag.6/6

Você também pode gostar