WHT

High resistance steel


for high tensile stress
Experimental testing carried out at KIT
(Karlsruhe Institute of Technology)
Hole distance for anchoring on concrete
optimized for easy installation
Use with both threaded nails (Anker) and
special screws
Application for
wood-concrete and wood-wood
Specifications online
(www.rothoblaas.com)
Full range (different dimensions and
possibility of use with or without washer)
ANGLE BRACKET
FOR TENSILE STRESS
Complete package: angle bracket,
nails and screws, threaded bars,
chemical anchors and equipment
available in the catalogue
High tensile strength guaranteed by
anchoring on concrete with a large diameter
Versatility of use with both platform
frame and panel buildings
Ideal junction for wooden buildings
in seismic areas
Inside
the static values
of the WKR285
APPLICATIONS
Resistance values depend on installation and the type of support. Main configurations:
Wood/Wood - Beam/Beam Wood/Wood - Beam/Column Wood/Concrete- Beam/Beam Wood/Concrete- Beam/Column
WOOD SIDE JUNCTION CEMENT SIDE JUNCTION
Threaded nails 4.0 x L Screw-in anchor (SKR)
Special screws 5.0 x L Threaded bar with chemical anchor
Mechanical dowel
See the attached diagrams for fastening types and modes of installation.
FASTENINGS
GENERAL CALCULATION PRINCIPLES
Characteristic values of resistance R
k
are calculated according to EN1995:2008, ETA 10/0010 and ETA 09/0324.
Design values R
d
are obtained as:
The calculation values shown are valid for wood components with characteristic density
k
350 kg/m
3
.
For
k
< 350 kg/m
3
, calculation values are multiplied by the reductive coefficient K
dens
= (
k
/ 350)
2
.
In the case of combined stress, the following condition must be verified:
NOTES:
F
2
and F
3
are opposing forces, only one of the two can be set equal to 0 kN.
F
4
and F
5
are opposing forces, only one of the two can be set equal to 0 kN.
The junction can be carried out
with a single angle bracket or with
2 angle brackets set symmetrically.
R
d
=
R
k
k
mod

m
H=20 mm
ULS707720
H=10 mm
ULS505610
H=10 mm
ULS505610
H=10 mm
ULS505610
TECHNICAL DRAWINGS - WHT
S 355 quality steel according to EN 10025-2:2004 with f
y,k
350 N/mm
2
.
FeZn 12c galvanic zinc with minimum thickness 12 m.
S 235 JR quality steel according
to EN 10326:2004 with
f
y,k
235 N/mm
2
.

Hot-dip galvanising for continu-
ous immersion with minimum
thickness 55 m.
FASTENING ON WOOD:
Anker Nail 4,0 x L
Special screw 5,0 x L
TECHNICAL DRAWINGS - WKR
FASTENING ON CONCRETE:
Threaded bar with
chemical anchor
Washer Washer Washer Washer
v
TYP WKR
R
k, WKR
R
k, WKR
[kN]
285
4,0 x 40 5,0 x 40
9 14,1
4,0 x 60 5,0 x 50
d d
0
h
min
T
[mm] [mm] [mm] [Nm]
10 12 20
16 18 80
20 24 120
m
[mm] [mm] [kN]
10 5.8 90 22,6 1,8
16 5.8 160 78,0 1,5
20 5.8 200 122,0 1,5
TYP WHT
[kN] [KN]
340
4,0 x 40 5,0 x 40
14
22,0
- 42,0
4,0 x 60 5,0 x 50 27,0
440
4,0 x 40 5,0 x 40
20
31,4
- 42,0
4,0 x 60 5,0 x 50 38,6
540
4,0 x 40 5,0 x 40
26
40,8
- 42,0
4,0 x 60 5,0 x 50 50,2
620
4,0 x 40 5,0 x 40
32
50,2
- 42,0
4,0 x 60 5,0 x 50 61,8
TYP WHT
[kN] [KN]
340
4,0 x 40 5,0 x 40
20
31,4
- 42,0
4,0 x 60 5,0 x 50 38,6
440
4,0 x 40 5,0 x 40
30
47,1 * H
63,4
4,0 x 60 5,0 x 50 57,9 10 mm
540
4,0 x 40 5,0 x 40
42
65,9 * H
63,4
4,0 x 60 5,0 x 50 81,1 10 mm
620
4,0 x 40 5,0 x 40
52
81,6 ** H
85,2
4,0 x 60 5,0 x 50 100,4 20 mm
4,0 x 40 5,0 x 40 1,57 kN
4,0 x 60 5,0 x 50 1,93 kN
WHT340 WHT440 WHT540 WHT620
16 16 20 16
WHT340 WHT440 WHT540 WHT620
16 16 20 16
2 3 4 5
1
WHT - PARTIAL NAILING Characteristic tensile strength
5 Holes Fastening
(connectors)
R
k
woodside R
k
steel side
n
conn
R
k, wood
Washer
R
k, steel
Anker Nails Special Screws [pcs.]
In accordance with ETA -10/0010 the wood side characteristic resistance is calculated as the
product between the number of inserted connectors (n
conn
) and the resistance of the single
connector: R
k, wood
= n
conn
R
k,conn
where the resistance of the single connector is equal to the values given in the table to the side.
Design resistance R
d
of the WHT is determined as the minimum value between the design
resistance of the wood side connectors and the design resistance of the steel side angle bracket.
The coefficients K
mod
and
m
are to be taken according to the standard used for calculation.
Connectors resistance
Nails Screws R
k, conn
Design resistance R
d
of the WKR is obtained as:
Anchors with vinylester can only be used on non-cracked concrete.
RESIN CHEMICAL ANCHOR
ThreadedBar h
e
N
k, extract
Steel class
Characteristic values of resistance to extraction according to ETA-09/0078. The values shown
refer to a single anchor without interaxis effects and distance from the edge on the surface
of the non-cracked concrete, dry and at a standard temperature for the depth indicated in the
table. For differing conditions, values are established according to what is indicated in the
design method A in ETAG 001 for anchors in concrete.
Installation parameters
h
e
+ 30
h
e
+ 30
h
e
+ 2 d
0
1 h
e
: actual anchoring depth
2 d: diameter of the threaded bar
3 d
0
: nominal diameter of top for the hole
4 h: thickness of the support in concrete
5 T: tightening torque
Design resistance N
d,extract
is calculated as:
Using 2 TYP WKR angle units for a single junction, design resistances double.
WKR - PARTIAL NAILING
Characteristic tensile
resistance
5 Holes Fastening
(connectors)
n
conn
Anker Nails Special Screws [pcs.]
TECHNICAL DATA - VERTICAL COMPONENT JUNCTION ON WOOD
* Washer ULS505610 ** Washer ULS707720
WHT - TOTAL NAILING Characteristic tensile strength
5 Holes Fastening
(connectors)
R
k
woodside R
k
steel side
n
conn
R
k, wood
Washer
R
k, steel
Anker Nails Special Screws [pcs.]
TECHNICAL DATA - JUNCTION ON CONCRETE
Using 2 TYP WKR angle units for a single junction, design resistances double.
10
R
d, WHT
= min
R
k,wood
k
mod

m, conn
R
k, steel

m, steel
R
k,WKR
k
mod

m
R
d, WKR
=
N
k,extract

m
N
d,extract
=
ASSEMBLY PHASES - CONCRETE SUPPORT
ASSEMBLY PHASES - WOOD SUPPORT
WKR installation and
fastening to the wall by
means of special screws
Fastening on wooden wall
by means of fully threaded
VGS screws (or, alternatively,
with a loop nut)
Injecting the vinylester chemical
anchor in the hole
Threaded Bar positioning Concrete drilling and hole
cleaning
WHT installation with relative
washer (if applicable)
Angle bracket nailing Nut positioning by means of suit-
able tightening torque
s
t
e
in
h
a
u
s
e
r
.
b
z

|

1
2
0
0
3
4
1
-
0
5

|

0
7
-
1
2
ACCESSORIES
APPLICATIONS - INSTALLED ANGLE BRACKETS
Positioning of the angle brackets on a concrete support typical for a wooden building
S
T
W
H
T
E
N
C O D
0339Z 40571

Você também pode gostar