Vidiwall HI W 333 Heat Bridge Catalog


Heat transfer coefficient of the construction elements of the exterior wall system W 333 Vidiwall HI
System description
The structure of the exterior wall system W 333, which is analyzed, consists of gypsum plaster boards 12,5 mm thick having a vapour barrier - Knauf Insulation LDS 10 Silk, rockwool - Knauf Insulation Fassaden-Dmmplatte TI 135 U, Classic 035, Naturoll 035, TI 135 H 100 mm thick imbedded in the load bearing structure of metal stud profiles - CW-Profil 100 x 50 x 0,6 mm or UA-Profil 100 x 40 x 2 mm, gypsum fibre board Vidiwall HI, heat insulation EPS 50; 60; 80; 100 and 150 mm thick and faade rendering. To calculate the heat transfer coefficient of the exterior wall system, a detail, designed with software used for determining the heat flow of periodically repeating metal profiles, which create a significant thermal bridge effect is used.

Boundary values
Description Interior temperature Exterior temperature Soil temperature Heat transfer resistance (on the outside) Heat transfer resistance (on the outside with ventilation) Heat transfer resistance (inside upward direction) Heat transfer resistance (inside, horizontally) Heat transfer resistance (inside downward direction) Heat transfer resistance (soil) Table 1 boundary values symbol value 20 -10 5 0,04 wall 0,13 0,10 roof 0,10 0,13 0,17 0,00 unit C C C

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


Cross section
Plan Knauf gypsum plaster board Steam barrier - Knauf Insulation LDS 10 Silk Knauf Knauf gypsum plaster board Heat insulation Knauf Insulation FassadenDmmplatte FPL-035 Metal profiles CW-Profil 100 x 50 x 0,6 mm / UAProfil 100 x 40 x 2 mm 15 Vidiwall HI board Knauf Styrokleber 50; 60; 80; Heat insulation EPS 100 and 150 anchors + reinforcing mesh adhesive-plastering mixture Knauf Klebespachtel plastering Knauf Marmorit Table Cross sectional profile of a system exterior wall W 333 Thickness in mm 12,5 0,5 12,5 100 Makeup Wert W/(mK) 0.210 0.220 0.210 0.035 50.000 0.300 0.054 0.035 0.038 0.540 0.870

Heat transfer coefficient (U-value) without metal profiles


Heat insulation layer thickness in mm EPS 50 EPS 60 EPS 80 EPS 100 EPS 150 Table 2 U-values without the effect of the metal structure U-value in W/(mK) 0,220 0,200 0,180 0,160 0,130

Equivalent value of the heat transfer coefficient (U-value) with metal profiles CW 100 x 50 x 0,6 mm
U value at axial U value at axial U value at axial distance b/n metal distance b/n metal distance b/n metal profiles profiles profiles 300 mm 400 mm 600 mm mm W/(mK) W/(mK) W/(mK) EPS 50 0,311 0,307 0,280 EPS 60 0,285 0,282 0,258 EPS 80 0,245 0,242 0,225 EPS 100 0,215 0,213 0,199 EPS 150 0,163 0,158 0,155 Table 3 Equivalent U-values with the effect of a metal structure of CW 100 x 50 x 0,6 Heat insulation layer thickness

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


Equivalent value of the heat transfer coefficient (U-value) with metal profiles UA 100 x 40 2
U value at axial U value at axial U value at axial Heat insulation layer distance b/n metal distance b/n metal distance b/n metal thickness profiles profiles profiles 300 mm 400 mm 600 mm mm W/(mK) W/(mK) W/(mK) EPS 50 0,341 0,336 0,300 EPS 60 0,309 0,306 0,276 EPS 80 0,263 0,260 0,237 EPS 100 0,229 0,226 0,209 EPS 150 0,171 0,171 0,161 Table 4 Equivalent U-values with the effect of a metal structure of UA 100 x 40 x 2

Graphical representation of the heat flow

Figure 1 Isothermal temperature curves in the cross-section

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog

Figure 2 Thermographic picture of the cross section of the system

Heat transfer coefficient of linear heat bridges the construction elements of the exterior wall system W 333 Vidiwall HI with metal profiles UA 100 x 40 2 PS 50 mm H1 connection to exterior wall reinforced concrete column

= 0,208 W/(mK)

H2 connection to exterior wall window/door

= 0,077 W/(mK)

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


3 01 connection to exterior walls (external angle)

= 0,028 W/(mK)

3 02 connection to exterior wall reinforced concrete column (external angle)

= 0,194 W/(mK)

Table 5 Heat bridges in W 333 Vidiwall HI with metal profiles UA 100 x 40 x 2 and EPS 50 mm 4 01 connection to exterior walls (internal angle)

= 0,060 W/(mK)

4 02 connection to exterior wall reinforced concrete column (internal angle)

= 0,088 W/(mK)

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


V1 01 connection to external wall sloped roof

= 0,111 W/(mK)

V1 02 connection to exterior wall flat roof

= 0,203W/(mK)

Table 6 Heat bridges W 333 Vidiwall HI with metal profiles Ua 100 x 40 x 2 and EPS 50 mm V1 03 connection to exterior wall flat roof (beam structure)

= 0,235 W/(mK)

V2 connection to exterior wall window/door

= 0,122 W/(mK)

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


V3 01 connection to exterior wall reinforced concrete slab (beamless structure)

= 0,135 W/(mK)

V3 02 Connection to exterior wall reinforced concrete slab (beamless structure)

= 0,221 W/(mK)

Table 7 Heat bridges W 333 Vidiwall HI with metal profiles Ua 100 x 40 x 2 and EPS 50 mm V4 01 Connection to exterior wall banded foundation

= -0,054 W/(mK)

HB Consulting Ltd. www.hbconsulting.eu

Vidiwall HI W 333 Heat Bridge Catalog


V4 02 socket connection at heated storeroom

= 0,033 W/(mK)

V4 03 socket connection at unheated storeroom

= -0,050 W/(mK)

Table 8 Heat bridges W 333 Vidiwall HI with metal profiles UA 100 x 40 x 2 and EPS 50 mm

Dipl. Eng. Ventzislav Vlahov

HB Consulting Ltd. www.hbconsulting.eu