Introduction

Standard Operating conditions

ABB has great experience in offering


Crane and Hoist duty motors both for
DOL operation as well as for VFD
applications.

Voltage 415V+/-10%
Frequency 50Hz+/-5%
Combined Voltage & Frequency
variation +/-10% ( absolute sum )
Ambient temperature:- 50 deg /45 deg
Altitude:-1000m

They conform to IS : 325 for Threephase Induction Motors and IS : 4722


for Rotating Electrical Machines .The
size of the motor is governed by the
mechanical effects of starting and
braking fuctions, the type of control and
the number of switching per hour. The
rated output, the number of starts/hour
and the inertia (i.e load GD2 +rotor
GD2) are interdependent.
With drive , its become utmost important
that the motors are selected suitably
considering the load details. The
selection of motors is done through
dedicated ABB software Drive Size TM
which takes care of all the proper
margins required as per application .
Thus ensuring motors can be used for
longer period of time with optimum
performance levels.
Scope:Crane duty Motors suitable for DOL &
VFD applications.
DOL
Frame- 71-200
KW rating:-0.37KW to 30KW
Pole:-4, 6 & 8 pole
CDF:- 25%, 40%, 60%, 100%
Starts-Stops/hr:-60, 150 , 300
VFD
Frame- 71-400
KW rating:- 0.25KW to 560KW
Pole:-4, 6 & 8 pole
CDF:- 25%, 40%, 60%, 100%
Starts-Stops/hr:-60, 150 , 300

Standards:The motors manufactured under crane


duty area comply to the following
standards:IS:325
IS:1231
IS:3177
IS:4137

IS:4722
IS:2223
IEC:60034-1

Deration Factors for ambient temp:Permissible Output


Amb. Temp.

100%
50

95%
55

Motor Selection Procedure:FOR DOL :The motors are selected from the chart
after matching the required starts stops
per hour & corresponding CDF .
FOR VFD :The motors are selected from the chart
based on the given mechanical KW .The
final motor KW is selected based on the
starts stops per hour , CDF & deration
on account of Drive. Depending upon
the type of crane employed , user has to
take applicable service factor as per IS
2231& IS4137 & correct the mechanical
KW accordingly. The permissible
temperature rise i.e, Class B will be
corresponding to the given mechanical
KW .

90%
60

Any deration required on account of


higher ambient temperature should be
considered separately based on the
above table applicable for both DOL &
VFD operation.

load & a rest & de-energised period. The


period is

Duty Cycle:The duty types are indicated by the


symbols S1 ... S9 according to IS:128241989. The outputs given in the tables are
based on continuous running duty. S1
with rated output.
S2
Short-time duty
Operation at constant load during a
given time, less than required to reach
thermal equilibrium, followed by a rest
and de-energised period of sufficient
duration to re-establish motor
temperatures equal to the ambient or the
coolant temperature. The values 10, 30,
60 and 90 minutes are recommended for
the rated duration of the duty cycle.
Designation e.g. S2 60 min.

S3
Intermittent duty
A sequence of identical cycles, each
including a period of operation at
constant

too short for thermal equilibrium


to be obtained. The starting current
does not significantly affect the
temperature rise.Recommended values
for the cyclic duration factor are 15, 25,
40 and 60%. The duration of the duty
cycle is 10 min.Designation e.g. S3 25%
S4
Intermittent duty with starting
A sequence of identical duty cycles,
each cycle including a significant period
of starting, a period of operation at
constant load and rest and de-energised
period. The period

is too short for thermal equilibrium to be


obtained. In this duty type the motor is
brought to rest by the load or by
mechanical braking, where the motor is
not thermally loaded. After the duty type
the following factors must be indicated;
the cyclic duration factor; the number of

duty cycles per hour (c/h); the factor of


inertia FI; the moment of inertia, J, of
the motor rotor; and the permissible
Maverage moment of resistance, T,
during the change of the Vspeed given
with the rated load torque. The factor
inertia FI is the ratio of the total moment
of inertia, to the moment of inertia of the
motor rotor.2Designation e.g. S4 - 25% 129 c/h - FI.2 - J= 0,1 kgm - T = M V0,5
T.V

S5
Intermittent duty with starting and
electrical braking .
A sequence of identical duty cycles,
each cycle consisting of a significant
period of starting, a period of operation
at constant load, a period of rapid
electric braking and a rest and deenergised period. The period is too short
for thermal equilibrium to be
obtained.After the duty type the
following factors must be indicated: the
cyclic duration factor; the number of
duty types per hour (c/h); the factor of
inertia FI; the moment of inertia J, of
the motor, and the Mpermissible
moment of resistance T (see duty type
S4.)V2Designation e.g. S5-40% -120
c/h- FI.3 - J= 1,3 kgm - T = 0,3 T.

Enquiries :
The following information should be
included during enquiry stage: a)Application.
b)Voltage and frequency variations.
c)Ambient temperature, and type of
protection
d)Mechanical KW with service factor as
applicable according to crane employed
e)No. of starts/stops per hour with duty
and CDF.
f)Type of starting
g)Load GD2 at motor speed.
h)Load torque ; or Torque/Speed curve
of driven equipment.
i) Duty cycle diagram, if other than those
described earlier.

(FOR DOL ONLY )


Series Name-KHX
Enclosure-TEFC

415V10%
50Hz5%

Pole-4

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B

Frame
KHX71C4
KHX80D4
KHX80D4
KHX90SLE4
KHX90SLE4
KHX100LC4
KHX112MC4
KHX132SME4
KHX132SME4
KHX160MLD4
KHX160MLE4
KHX160MLE4
KHX180MLC4
KHX200MLD4

60 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
53.3

0.55
0.75
1.1
1.5
2.2
7.9
5.5
7.5
9.3
11
15
18.5
22
30

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
53.3

Ambient -45 deg


Duty -S4 & S5 (equivalent)

150 Starts
25% OR 40 % CDF
Kw
In (A)
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
53.3

60 % CDF
Kw
In (A)
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
30

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
53.3

300 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
26

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
46

0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22
26

1.6
2.0
3.1
3.4
5.2
7.9
11.3
14.5
18.7
21
28
35.6
40.5
46

Motor GD Sq.

Weight

Kgm.sq

Kg

0.0035
0.007
0.007
0.017
0.017
0.028
0.062
0.112
0.112
0.252
0.302
0.302
0.54
1.344

13.5
15
15
27
27
39.5
49
80
80
145
160
160
185
265

Series Name-KHX

415V10%

(FOR DOL ONLY )


Pole-6

Enclosure-TEFC
Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B

Frame
KHX80B6
KHX80D6
KHX80D6
KHX90SLE6
KHX90SLE6
KHX100LB6
KHX112MC6
KHX132SME6
KHX132SME6
KHX160MLD6
KHX160MLE6
KHX160MLE6
KHX200MLC6
KHX200MLC6

60 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
36
42

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
36
42

25% OR 40 % CDF
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
36
42

50Hz5%
Ambient -45 deg
Duty -S4 & S5 (equivalent)

150 Starts
60 % CDF
Kw

In (A)

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
36
42

300 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
17
18.5

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
33
36

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
17
18.5

1.2
1.6
2.3
2.9
4.1
5.9
10.5
12.5
18.2
19
23
34.7
33
36

Motor GD Sq.

Weight

Kgm.sq

Kg

0.006

13

0.008
0.008
0.017
0.017
0.017
0.62
0.12
0.12
0.372
0.446
0.446
1.8
1.8

15
15
28
28
28
48
80
80
155
170
170
300
300

(FOR DOL ONLY )

Series Name-KHX
Enclosure-TEFC

Pole-8

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B

Frame
KHX90SLA8
KHX90SLD8
KHX90SLD8
KHX100LB8
KHX100LB8
KHX112MB8
KHX132SMC8
KHX160MLD8
KHX160MLE8
KHX160MLE8
KHX180MLB8
KHX200MLC8

60 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

415V10%
50Hz5%

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
23.5
28

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
23.5
28

Ambient -45 deg


Duty -S4 & S5 (equivalent)

150 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
23.5
28

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
23.5
28

300 Starts
25% OR 40 % CDF
60 % CDF
Kw
In (A)
Kw
In (A)
0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
23.5
28

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
10
11

1.4
1.9
2.7
3.9
6
7.8
10.5
12
16
19.8
22
24

Motor GD Sq. Weight

Kgm.sq

Kg

0.012

22

0.015
0.015
0.026
0.026
0.048
0.08
0.372
0.446
0.446
0.72
2.21

25
25
35
35
48
65
155
170
170
200
250

Note: 1..All crane duty motors are suitable for VFD supply subject to proper selection using ABB Drive Size Software considering required BKW, speed range and constant torque appln.
2. All crane duty motors shall be offered as MI motors
3. Load GD Sq value should not be more than motor GD sq value.
4. Motors for frame size 225 and higher can be offered against enquiry
5)For class H insulation & temperature rise limited to Class F , 15% higher KW can be considered.

Crane Duty Motors Chart


(For VVVF Drive Only)
Series Name-KHX+
Enclosure-TEFC

415V10%
50Hz5%

Pole-6

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B
FRAME

Ambient -50 deg


Duty -S4 & S5 (equivalent)

MOTOR
Current
RATING

Motor GD

Weight

(Kg m)

Kg

0.008

15

0.015
0.008
0.017
0.026
0.05
0.088
0.12
0.326
0.372
0.446
0.68
1.6
1.8

25
15
28
35
46
70
80
145
155
170
185
230
300

Maximum Permissible Mechanical KW


150 STARTS STOPS PER HOUR

KHX+80D6
KHX+90SLD6
KHX+90SLE6
KHX90SLE6
KHX+100LB6
KHX+112MB6
KHX+132SMC6
KHX+132SME6
KHX+160MLC6
KHX+160MLD6
KHX+160MLE6
KHX+180MLC6
KHX+200MLB6
KHX+200MLC6

KW

25 OR 40
% CDF

In(A)

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15
18.5
22

1.2
1.6
2.3
2.9
4.1
5.9
8.3
12.5
15.5
19
23
30
36
42

0.3
0.45
0.6
0.9
1.2
1.7
2.9
4.3
5.8
7.2
7.6
11.7
14.2
16.8

1.0
1.4
1.9
2.5
3.3
4.6
6.6
10
12.2
14.8
16
24
28
33

60% CDF In(A) 100% CDF In(A)


0.30
1.0
0.26
0.9
0.4
1.3
0.45
1.4
0.6
1.9
0.5
1.8
0.9
2.5
0.8
2.4
1.2
3.3
1.1
3.1
1.7
4.6
1.5
4.3
2.9
6.6
2.6
6.2
4.3
10
3.9
9.5
5.8
12.2
5.2
11.5
7.2
14.8
6.5
14.0
7.6
16
6.8
15.1
11.7
24
10.5
22.7
14.2
28
12.8
26.5
16.8
33
15.1
31.2

300 STARTS STOPS PER HOUR

25 OR 40 %
CDF

In(A)

60 % CDF

In(A)

0.3
0.45
0.6
0.9
1.2
1.7
2.9
4.3
5.8
7.2
7.6
11.7
14.2
16.8

1.0
1.4
1.9
2.5
3.3
4.6
6.6
10
12.2
14.8
16
24
28
33

0.3
0.45
0.6
0.9
1.2
1.7
2.9
4.3
5.8
7.2
7.6
11.7
14.2
16.8

1.0
1.4
1.9
2.5
3.3
4.6
6.6
10
12.2
14.8
16
24
28
33

Note:-

1)Maximum permissible Mechanical KW has been calculated based on VVVF supply & duty cycles
2)Separate derations are required for different service factors for different cranes & ambient temperature
3)Speed range 10-100%
4)Load GD square is assumed to be equal to motor GD
5)For class H insulation & temperature rise limited to Class F , 15% higher mechanical KW can be considered.

100% CDF
0.25
0.4
0.5
0.8
1.0
1.4
2.5
3.7
4.9
6.1
6.5
9.9
12.1
14.3

In(A)
0.8
1.2
1.6
2.1
2.8
3.9
5.6
8.4
10.3
12.5
13.5
20.2
23.6
27.8

Crane Duty Motors Chart


(For VVVF Drive Only)
Series Name-KHX+ & M2BA
Enclosure-TEFC

415V10%
50Hz5%

Pole-6

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B
FRAME

MOTOR
Current
RATING

Ambient -50 deg


Duty -S4 & S5 (equivalent)

Maximum Permissible Mechanical KW


150 STARTS STOPS PER HOUR

KHX+225SMC6
KHX+250MB6
KHX+280SMB6
KHX+280SMC6
M2BA315SMA6
M2BA315SMB6
M2BA315SMC6
M2BA315MLC6
M2BA355SMA6
M2BA355SMB6
M2BA355MLA6
M2BA355MLB6
M2BA400LA6
M2BA400LB6

KW
30
37
45
55
75
90
110
132
160
200
250
315
355
400

A
55.5
66
79.5
97
132
158
193
228
275
343
428
550
640
740

25 OR 40
% CDF
25
30
35
42
55
75
88
96
110
136
185
240
252
270

In(A)
50
55
65
68
110
135
165
180
200
260
340
450
500
610

60% CDF
23
27
33
39
53
69
83
92
107
133
177
227
243
260

In(A)
45
50
60
65
100
125
160
175
195
255
325
425
485
590

100% CDF
20
25
30
36
49
62
75
86
101
125
164
210
205
245

Motor
GD

Weight

(Kg m)
2.98
4.8
7.2
8.1
14.2
16.7
20
28.2
42
50.5
55
60.2
66
77

Kg
320
420
590
600
860
930
1005
1240
1595
1800
1940
2040
3000
3100

300 STARTS STOPS PER HOUR

In(A)
40
46
55
60
92
118
150
165
185
240
305
395
410
560

25 OR 40
% CDF
21
27
31
36
47
68
77
83
92
114
160
210
212
237

Note:-

1)Maximum permissible Mechanical KW has been calculated based on VVVF supply & duty cycles
2)Separate derations are required for different service factors for different cranes & ambient temperature
3)Speed range 10-100%
4)Load GD square is assumed to be equal to motor GD square
5)For class H insulation & temperature rise limited to Class F , 15% higher mechanical KW can be considered.

In(A)
40
50
58
60
90
128
155
164
180
220
300
395
420
550

60 % CDF
20
26
29
35
46
65
75
82
90
110
158
205
210
230

In(A)
40
48
55
57
85
122
150
160
178
215
295
390
415
540

100% CDF
19
24
28
34
45
60
71
79
88
108
152
195
185
210

In(A)
36
45
54
55
83
115
145
155
175
212
285
375
400
500

Crane Duty Motors Chart


(For VVVF Drive Only)
Series Name-KHX+
Enclosure-TEFC

415V10%
50Hz5%

Pole-8

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B
FRAME

MOTOR
Current
RATING

Ambient -50 deg


Duty -S4 & S5 (equivalent)

Maximum Permissible Mechanical KW


150 STARTS STOPS PER HOUR

KHX+90SLA8
KHX+90SLD8
KHX+100LA8
KHX+100LB8
KHX+112MA8
KHX+132SMB8
KHX+160MLB8
KHX+160MLD8
KHX+160MLE8
KHX+180MLA8
KHX+180MLB8
KHX+200MLC8

KW

25 OR 40
% CDF

In(A)

60% CDF

In(A)

0.37
0.55
0.75
1.1
1.5
2.2
3.7
5.5
7.5
9.3
11
15

1.4
1.9
3.1
3.9
4.8
6.3
8
12
16
20
23.5
31.5

0.29
0.44
0.58
0.85
1.2
1.7
2.8
4.3
5.9
7.2
8.6
11.6

1.1
1.6
2.5
3.3
3.8
6.0
6.6
10
14
16
18
25

0.29
0.44
0.58
0.85
1.2
1.7
2.8
4.3
5.9
7.2
8.6
11.6

1.1
1.6
2.5
3.3
3.8
6.0
6.6
10
14
16
18
25

100% CDF
0.26
0.40
0.52
0.77
1.1
1.5
2.5
3.9
5.3
6.5
7.7
10.4

Motor
GD

Weight

(Kg m)

Kg

0.012

22

0.015
0.02
0.026
0.044
0.06
0.288
0.372
0.446
0.64
0.72
1.98

25
35
35
45
60
125
155
170
160
170
240

300 STARTS STOPS PER HOUR

In(A)
1.0
1.5
2.4
3.1
3.6
5.7
6.2
9.5
13.2
15.1
17.0
23.6

25 OR 40
% CDF

In(A)

60 % CDF

In(A)

0.29
0.44
0.58
0.85
1.2
1.7
2.8
4.3
5.9
7.2
8.6
11.6

1.1
1.6
2.5
3.3
3.8
6.0
6.6
10
14
16
18
25

0.29
0.44
0.58
0.85
1.2
1.7
2.8
4.3
5.9
7.2
7.8
8.6

1.1
1.6
2.5
3.3
3.8
6.0
6.6
10
14
16
16.6
25

Note:-

1)Maximum permissible Mechanical KW has been calculated based on VVVF supply & duty cycles
2)Separate derations are required for different service factors for different cranes & ambient temperature
3)Speed range 10-100%
4)Load GD square is assumed to be equal to motor GD square
5)For class H insulation & temperature rise limited to Class F , 15% higher mechanical KW can be considered.

100% CDF
0.2
0.4
0.5
0.7
1.0
1.4
2.4
3.7
5.0
6.1
6.6
7.3

In(A)
1.0
1.4
2.2
2.9
3.4
5.4
5.9
8.9
12.5
14.3
14.8
22.3

Crane Duty Motors Chart


(For VVVF Drive Only)
Series Name-KHX+ & M2BA
Enclosure-TEFC

415V10%
50Hz5%

Pole-8

Protection/Cooling-IP55 / IC411
Insulation class-F
Temperature rise Class-B
FRAME

Ambient -50 deg


Duty -S4 & S5 (equivalent)

MOTOR
Current
RATING

Motor GD

Weight

(Kg m)
3.32
3.5
4.54
7.64
7.75
13
18.8
22
23.6
42
55
64.2
66
68.8
80

Kg
320
340
520
590
600
830
975
1055
1125
1590
1945
2090
2100
2800
3100

Maximum Permissible Mechanical KW


150 STARTS STOPS PER HOUR

KHX+225SMB8
KHX+225SMC8
KHX+250MB8
KHX+280SMB8
KHX+280SMC8
M2BA315SMA8
M2BA315SMB8
M2BA315SMC8
M2BA315MLB8
M2BA355SMA8
M2BA355MLA8
M2BA355MLB8
M2BA355MLB8K
M2BA400LA8
M2BA400LB8

KW
18.5
22
30
37
45
55
75
90
110
132
160
200
250
315
355

A
38.5
45.5
60
73.5
89
101
135
162
197
239
289
360
470
600
670

25 OR 40
% CDF
15
19
25.5
30
38
42.5
55
77
87
100
120
155
194
238
308

In(A)
34
42
55
62
78
87
110
150
165
205
240
310
405
510
610

60% CDF In(A) 100% CDF In(A)


14.5
33
13
30
17.5
39
15.5
35
23.5
52
21
48
28
58
25
52
35
72
31
64
40
82
36
75
53
106
50
100
71
135
63
120
82
155
75
142
95
195
88
182
114
230
105
215
146
295
134
275
183
385
168
355
226
485
208
450
280
560
250
510

300 STARTS STOPS PER HOUR

25 OR 40 %
CDF
14
17
23
27
34
38
52
68
78
87
104
136
171
208
257

In(A)
32
38
50
56
70
78
105
130
150
180
210
280
360
450
520

Note:-

1)Maximum permissible Mechanical KW has been calculated based on VVVF supply & duty cycles
2)Separate derations are required for different service factors for different cranes & ambient temperature
3)Speed range 10-100%
4)Load GD square is assumed to be equal to motor GD
5)For class H insulation & temperature rise limited to Class F , 15% higher permissible mechanical KW can be considered.

60 % CDF
13.5
16
22.5
26
33
36
50
66
76
86
103
133
167
204
250

In(A)
31
36
48
54
68
75
100
125
146
175
208
275
355
445
510

100% CDF
12
15
20.5
24
30
34
45
60
70
82
98
126
157
195
245

In(A)
28
35
44
50
62
72
90
115
135
168
200
262
335
428
500