Unit Inlet Liquor Actual Flow rate Designed Flowrate Volumetric flowrate Bx Purity Liquor density Sp.

heat Inlet liq temp. Inlet liquor velocity Outlet Liquor Actual Flow rate (t/h) Designed Flowrate Volumetric flowrate Bx Purity Liquor density Sp. Heat Outlet liq temp. Outlet liquor velocity Vapor Temp. Sp. Volume Enthalpy Vapor Qty Volumetric flowrate Vapor velocity Calculated Dia Inlet Liquor Dia Outlet liquor Dia Vapor inlet Dia Shell Dia Annular dia Inlet Liquor Dia Outlet liquor Dia Vapor inlet Dia Shell Dia Cone dia Annular dia mm mm mm mm mm mm mm mm mm mm mm C kg/m3 kcal/kg t/h m3/sec m/sec t/h t/h m3/sec kg/m3 kcal/kg.C C m/sec t/h t/h m3/sec

VALUES 172 172.00 0.0473 12.09 76.15 1009.67 0.945 95 1.25 173.07 190.38 0.05 12.015 76.15 1006.86 0.946 98.6 1 100 0.5979 638.8888889 1.07 0.50 30 220 259 145 854.61 400 250 250 250 1000 250 250

PUMP Suction Water Juice Syrup Molasses Massecuites PUMP Delivery Water Juice Syrup Molasses Massecuites

min 1 1 0.5 0.25 0.1 min 1.25 1.2 0.75 0.5 0.15

max 1.25 1.2 1 0.5 0.2 max 2.5 2 1.25 0.75 0.3

kg/m3 kcal/kg.C C m/sec

Designed Dia (AS PER REQUIREMENT)

NCG Dia Height Pressure Working pressure Design Pressure Hydro test pressure CSA DCH CSA Cone CSA Actual annular CSA Actual annular velocity

mm m kPa kPa kPa m2 m1 m2 m/sec

250 3 85 300 350 0.785 0.0490625 0.7359375 1.477360509