Escolar Documentos
Profissional Documentos
Cultura Documentos
Navigate to Navigate to
Search
Like
Follow @MarineInsight
Ads by Google
Maritime Jobs
Marine Vacancy
Marine Equipment
Seagoing Jobs
Ansul Kitchen Fire Protec R-102 and Piranha Kitchen Fire Protection Systems The Fire Beam "this is by far the best beam money can buy"
www.ansul.co.za www.nor-electronics.no/
Public Address PAGA Public Address & General Alarm PAGA Custom made for Oil & Gas
www.therebeamcompany.com
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire
Submitted by Anish on January 14, 2012 1:14 am No Comment
38
4
Share
A major engine room re is similar to a terrifying nightmare for a seafarer. Fire in the engine room not only disables the ships propelling plant but also causes a complete blackout situation, which can result in collision or grounding of the ship.
Ansul Kitchen Fire Protec www.ansul.co.za R-102 and Piranha Kitchen Fire Protection Systems
Public Address PAGA www.nor-electronics.no/ Public Address & General Alarm PAGA Custom made for Oil & Gas
www.remiks.com
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire | Marine Insight
In case of a major engine room re on merchant ships, CO2 xed re extinguishing system is the most common method used for extinguishing re. The chief engineer of the ship is responsible for operating the CO2 extinguishing system,after taking all precautionary measures.
There have been several cases in the past, wherein the engine room crew has been killed not because of the re but because of suffocation after CO2 was released in the engine room. Suffocation of the crew combined with re-ignition of re due to lack of air tight engine room has resulted in gruesome condition as after using CO2 no more reghting method is available (CO2 system can be used only once). The CO2 operator in-charge i.e. Chief engineer (or 2nd engineer in C/Es absence) has to be extremely careful when it comes to following procedure to avoid re or any casualty. Following steps are to be followed without fail for extinguishing major nd in engine room. 1. On outbreak of re, the re alarm will sound and bridge ofcer will know the location of re. If the re is big enough to ght with portable extinguishers, all crew should be gathered in muster station for head count. 2. Inform wheel house about the situation of the re and the chief engineer should take decision in consent with the master to ood the engine room with CO2 to extinguish re. 3. Emergency generator should be started as CO2 ooding requires all machineries including auxiliary power generator to be stopped. 4. Reduce ship speed and stop the main engine at safe location. Captain should inform the nearest coastal authority if the ship is inside a coastal zone. 5. Open the Cabinet of CO2 operating system in the re station with the Key provided nearby in glass case. This will give an audible CO2 Alarm in the engine room. 6. Some systems and machinery like engine room blowers and fans
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire | Marine Insight etc. will trip with opening of CO2 cabinet. Counter check all the tripped system for surety. 7. Make sure there no one is left inside the engine room by repeating the head count. 8. Operate all remote closing switches for quick closing valve, funnel aps, re aps, engine room pumps and machinery, water tight doors etc. 9. Air condition unit of ECR should be stopped. 10. Close all the entrance doors of the engine room and make sure the room is air tight. 11. Operate the control and master valve in the CO2 cabinet. This will sound another alarm and after 60 seconds time delay CO2 will be released for re extinguishing. 12. If there is need to enter the engine room for rescuing a person (which must beavoided, SCBA sets and life lines should be used). Safety of personnel should be of the highest priority during such incidences.
Read More Abput FSS Code FM 200 16 Fire Fighting Equipment Electrical Cable Insulation
Related posts: 1. Fire Fighting CO2 System for Cargo holds 2. What to Do in Case of Purier Room Fire? 3. Engine Room Flooding: Troubleshooting and Immediate Actions 4. Sprinkler System : Automatic Fire Detection, Alarm and Extinguishing System on Ship 5. Top Reasons for which a 4th Engineer Should Call the Chief Engineer to the Engine Room
Like
Follow @MarineInsight
Email:
Facebook comments:
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire | Marine Insight
Like
Leave a comment! Add your comment below, or trackback from your own site. You can also subscribe to these comments via RSS. Be nice. Keep it clean. Stay on topic. No spam.
Name (required)
Mail (Required)
Website (optional)
This is a Gravatar-enabled weblog. To get your own globallyrecognized-avatar, please register at Gravatar.
Post Comment
Email:
Submit
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire | Marine Insight
Popular
Latest
Comments
7 Reasons Deck Cadets and Junior Engineers are Not Getting Jobs September 5, 2011
A Woman Chief Engineer from Brazil Describes Her Interesting Life March 14, 2011
Bunkering is Dangerous : Procedure for Bunkering Operation on a Ship October 19, 2010
Marine Caree
Maritime Secu
random posts
12 Must-Do Things Before Operating CO2 Fire Extinguishing System for Engine Room Fire | Marine Insight
resources
23 Places to Find Maritime Jobs What is the Salary of Seafarers? Best Maritime Colleges in the United States Top 6 Books on Marine Auxiliary Machinery 23 Maritime Forums and Discussion Boards Shore Jobs for Seafarers Top 5 Books on Marine Boiler How to nd Contacts in Maritime Companies?
most commented
Duties of a 4th Engineer on a Ship 7 Reasons Deck Cadets and Junior Engineers are Not Getting Jobs A Woman Chief Engineer from Brazil Describes Her Interesting Life How to Synchronize Generators on a Ship? Bunkering is Dangerous : Procedure for Bunkering Operation on a Ship
About Us Contact Us Subscribe to Marine Insight Privacy Policy Follow us on Twitter Follow us on Facebook Forums Jobs Directory