Você está na página 1de 3

Process Instrumentation

1. the most suitable instrument for measuring temperature in the range of 40 to 425 C is a) Mercury thermometer c) Bimetallic thermometer 2. Polar graph is used for the analysis of a) Gases b) liquids & gases c) solids d) liquids b) Radiation pyrometer d) platinum resistance thermometer

3. Amount of moisture in air is determined by a) Refractometer b) polarimeter


2

c) hygrometer

d) polarograp

4. Composition of CO in the flue gas is determined by ___________________ a) thermal conductivity of cell c) Curies Law 5. P H of Neutral solutions is a) 5 b) 5-7 c) 7-9 d) 7 b)Seed back Effect d) None of the above

6. Bolometer is used for the measurement of _____________________ a) Temperature b) Pressure c) Both a & b d) None

7. An example for a desirable static characteristic is a). Static error b). Drift c). Dead zone d). Sensitivity.

8. A house hold energy meter is an example for________________ instrument. a). Transmitting b). Signaling c). Registering d). Indicating

9. Dead zone is the largest range of values of a _____________ variable to which the instrument does not respond a)measured b) Process c) Bothe a & b d) None

10. The conductivity of most metals __________ with temperature a) Increases b) Decreases c) Remains Same d) None

11. What is the normal percentage of rhodium in platinum + rhodium element used in the thermocouple? a)0.1 b) 3 c) 10 d)13

12. Pyrometry refers to the measurement of temperature a) With the mercurial thermometer up to 3500C c) Which is of higher magnitude 13. Temperature range of optical pyrometer is ------a) 1000 -2000 b) 2000-6000
o

b) Directly d) All (a), (b) and (c) F d) 2000-6000

c) 1000-5000

14. A mercury thermometer cannot be used to measure temperatures below freezing point of mercury, which is oF a) 28 b) 38 c) 48 d) 58

15. Continuous measurement of moisture content of paper in paper industry is done by measuring the a) Thermal conductivity through the paper c) Magnetic susceptibility 16. Polarographs is used for the analysis of a) Solids b) liquids c) gases d) liquids, gases b) Electrical resistance through the paper d) none of these

17. Amount of moisture in air is determined by a) Thermometer b) bolometer c) polarimeter d) hygrometer

18. Thermal wells used in temperature measurements should have a) Low emissivity c) Ceramic fiber b) High transmissivity of radiation d) none

19. Which of the following is not suitable for measuring the temperature of a red hot object in the range of 800 - 1600C ? a)thermocouples c)Radiation pyrometer b) Pyrometer d) None

20. Concentration of sugar solution can be determined by the a)Polarimetry c) Emissivity b)Thermal wells d) Both a & b

Você também pode gostar