Escolar Documentos
Profissional Documentos
Cultura Documentos
D184S075U02
The Electromagnetic Flowmeter (EMF) can be used to accurately measure the flowrate of liquids which have an electrical conductivity greater than 5 S/cm (20 S/cm for demineralized water). The COPA-XE is a flow measurement system in a Compact Design. The MAG-XE flow measurement system consists of a flowmeter primary and a remote mounted converter Flowmeter primary for hygienic processes - The basic flowmeter body is installed using threaded adapters which are matched to the respective pipeline connections. The following connections are available: - Weld stubs - Food industry fittings per DIN 11851 - Tri-Clamp - Wafer and fixed flange designs - Certificates EHEDG, FML, 3A Flowmeter primary for the process industry and water/waste water - Flange and wafer designs - DVGW Test Report - Certifiable for cold and waste water and fluids other than water Converter - Communication PROFIBUS DP, HART-Protocol, FOUNDATION Fieldbus, PROFIBUS PA - Pulse output, configurable (active/passive) - Data secured in a plug-in EEPROM - Graphic display - Self-monitoring functions - Comprehensive test and simulation functions
P R O F
PROCESS FIELD BUS
B U S
Contents
D184S075U02
Contents
1 2 3 FXE4000 (COPA-XE): Overview, Flowmeter Primary and Converter Designs: .............................................3 FXE4000 (MAG-XE): Overview, Flowmeter Primary and Converter Designs ................................................4 General information ............................................................................................................................................5 3.1 3.2 3.3 3.4 3.5 3.6 4 4.1 4.2 5 5.1 5.2 5.3 5.4 5.5 6 7 Measuring Accuracy.......................................................................................................................................5 Grounding.......................................................................................................................................................5 Installation Requirements...............................................................................................................................5 Flowmeter Sizes, Pressure Ratings, Flow Range..........................................................................................7 Flowrate nomograph ......................................................................................................................................8 Approved EMF for custody transfer ...............................................................................................................9 Model DE41F, DE41W, DE43F, DE43W .....................................................................................................10 Model DE 21, DE21F, DE23, DE23F ...........................................................................................................31 Specifications: ..............................................................................................................................................45 Housing Variants ..........................................................................................................................................45 In- / Outputs..................................................................................................................................................46 Digital Communication .................................................................................................................................47 Converter scale drawing FXE 4000-E4 (MAG-XE) ......................................................................................56
Specifications: ...................................................................................................................................................10
Transmitter.........................................................................................................................................................45
Ordering Information Wafer Accessories (Table H).......................................................................................59 Ordering Information Flowmeter Primary Simulator FXC 4000 ....................................................................60
D184S075U02
Housing Material
Fixed Flange
Fixed Flange
Wafer Design
Variable Connections DE23-R,-S,-T,-E DN 3 ... 100 (1/10... 4") 3 ... 100 (1/10... 4") 3 ... 100 (1/10... 4") 3 ... 100 (1/10... 4") 3 ... 25 (1/10... 1") 10 ... 40 10 ... 40 10 ... 40 10 ... 40 10 PN
Flowmeter Primary
Model Number Accuracy DN Wafer Design Flange DIN 2501/ EN 1092-1 Flange ASME B16.5 / B16.47 Food Ind. Fitting DIN 11851 Weld stubs Tri-Clamp per DIN 32676 Tri-Clamp per ASME BPE External threads ISO 228 Liner Conductivity Electrodes Process Connection Material Protection Class Fluid Temperature * 3 ... 1000 10 ... 40 1/8 ... 40" CL 150 ... 300 DE43F PN DN 3 ... 100 DE23F DE23W 0.5 % of rate, Optional 0.25% of rate PN DN PN DN PN 16 3 ... 100 10 ... 40 3 ... 100 10 ... 40 1/8 ... 4" CL 150 ...300 -
Hard/soft rubber PTFE, PFA (DN 3 ... 8) PFA (vacuum tight) PFA (vacuum tight) PFA (vacuum tight) PFA PTFE (DN 10 ... 100) > 5 S/cm > 5 S/cm > 5 S/cm > 5 S/cm > 5 S/cm (20 S/cm for (20 S/cm for (20 S/cm for (20 S/cm for (20 S/cm for demineralized water) demineralized water) demineralized water) demineralized water) demineralized water) SS 1.4571[316Ti], 1.4539, Hastelloy B2/C4, Platinum-Iridium, Tantalum, Titanium Steel, 1.4571[316Ti] 1.4571 [316Ti] 1.4404 [316L] IP 67 IP 67 IP 67 IP 67 IP 67 -25 ... +130 C -25 ... +130 C -25 ... +130 C -25 ... +130 C -25 ... +130 C -13 ... +266 F -13 ... +266 F -13 ... +266 F -13 ... +266 F -13 ... +266 F TV 97, ATEX 1173X (see separate data sheet) Cold- and Waste Water, Liquids other than Water With Conformity Evaluation per Category III, Fluid Group 1 Without Approval Approval Upon Request
Approvals
EEx Design Certifiable Press. Equip. Dir. 97/23/EG CRN ( Canadian Registration Number)
Certificates
3A, EHEDG (Cleanability)
Converter
Supply Power Current Output Pulse Output Ext. Zero Return Ext. Totalizer Reset Forward/Reverse Flow Metering Empty Pipe Detector Self Monitor Local Display / Totalization Housing Communication AC 100-230 V (-15/+10 %) / AC 16.8-26.4 V / DC 16.8-31.2 V 0/2-10 mA, 0-5 mA, 0/4-20 mA, 0/4-10/12-20 mA Active 24 V DC pulse or passive optocoupler Optocoupler input Optocoupler input Signal over optocoupler output from DN 10, Signal over optocoupler output yes yes Converter housing made of Aluminum (standard), converter made of stainless steel (option) PROFIBUS DP, PROFIBUS PA, HART-Protocol, FOUNDATION Fieldbus, ASCII-Protocol (RS485)
*) -25 C if the process connection is made of stainless steel / -10 C if the process connection is made of steel 1) Weld stubs, 2) Tri-Clamp, 3) Food Ind. Fittings, 4) External Threads
D184S075U02
Housing Material
Fixed Flange
Fixed Flange
Wafer Design
Variable Connections DE21-R,-S,-T,-E DN 3 ... 100 (1/10 ... 4") 3 ... 100 (1/10 ... 4") 3 ... 100 (1/10 ... 4") 3 ... 100 (1/10 ... 4") 3 ... 25 (1/10 ... 1") 10 ... 40 10 ... 40 10 ... 40 10 ... 40 10 PN
Flowmeter Primary
Model Number Accuracy DN Wafer Design Flange DIN 2501/ EN 1092-1 Flange ASME B16.5 / B16.47 Food Ind. Fitting DIN 11851 Weld stubs Tri-Clamp per DIN 32676 Tri-Clamp per ASME 32676 External threads ISO 228 Liner Conductivity Electrodes Process Connection Material Protection Class Fluid Temperature * 3 ... 1000 Hard/soft rubber PTFE, PFA > 5 S/cm (20 S/cm for demineralized water) 10 ... 40 1/8 ... 40" CL 150 ... 300 DE41F PN DN 3 ... 100 DE21F DE21W 0.5 % of rate, Optional 0,25 % of rate PN DN PN DN PN 16 3 ... 100 10 ... 40 3 ... 100 1/8 ... 4" 10 ... 40 CL 150 ... 300 -
PFA (DN 3 ... 8) PFA (vacuum tight) PFA (vacuum tight) PFA (vacuum tight) PTFE (DN 10 ... 100) > 5 S/cm > 5 S/cm > 5 S/cm > 5 S/cm (20 S/cm for (20 S/cm for (20 S/cm for (20 S/cm for demineralized water) demineralized water) demineralized water) demineralized water) SS 1.4571[316Ti], 1.4539, Hastelloy B3/C4, Platinum-Iridium, Tantalum, Titanium Steel, 1.4571[316Ti] 1.4571 [316Ti] 1.4404 [316L] IP 67 IP 67 IP 67 IP 67 IP 67 IP 68 (Option) -25 ... +130 C -13 ... +266 F IP 68 (Option) -25 ... +130 C -13 ... +266 F IP 68 (Option) -25 ... +130 C -13 ... +266 F IP 68 (Option) -25 ... +130 C -13 ... +266 F IP 68 (Option) -25 ... +130 C -13 ... +266 F
Approvals
EEx Design Certifiable Press. Equip. Dir. 97/23/EG CRN ( Canadian Registration Number) TV 97, ATEX 1173X (see separate data sheet) Cold- and Waste Water, Liquids other than Water With Conformity Evaluation per Category III, Fluid Group 1 Without Approval Approval Upon Request
Certificates
3A, EHEDG (Cleanability)
Converter
Supply Power Current Output Pulse Output Ext. Zero Return ext. Totalizer Reset Forward/Reverse Flow Metering Empty Pipe Detector Self Monitor Local Display / Totalization Housing Communication AC 100-230 V (-15/+10 %) / AC 16.8-26.4 V / DC 16.8-31.2 V 0/2-10mA, 0-5 mA, 0/4-20 mA, 0/4-10/12-20 mA Active 24 V DC pulse or passive optocoupler Optocoupler input Optocoupler input Signal over optocoupler output from DN 10, Signal over optocoupler output yes yes Field mount housing, Panel mount housing, Rail mount housing PROFIBUS DP, PROFIBUS PA, HART-Protocol, FOUNDATION Fieldbus, ASCII-Protocol (RS485)
*) -25 C if the process connection is made of stainless steel / -10 C if the process connection is made of steel 1) Weld stubs, 2) Tri-Clamp, 3) Food Ind. Fittings, 4) External Threads
D184S075U02
3
3.1
General information
Measuring Accuracy Reference Conditions per EN 29104
20 C (68 F) 2 K 20 C (68 F) 2 K Line voltage per name plate UN 1 % and Frequency f 1 % - Upstream >10xDN straight section - Downstream >5xDN straight section 30 min
3.2
Grounding
3.1.1
Warm Up Phase
The grounding of the flowmeter primary is essential for both safety reasons, and to ensure trouble-free operation of the electromagnetic flowmeter. The ground screws on the flowmeter primary are to be brought to ground potential. For technical reasons, this potential should be identical to the potential of the metering fluid, if possible. For plastic or insulated lined pipelines, the fluid is grounded by installing ground plates. When there are stray currents present in the pipeline, a ground plate is recommended on both ends of the meter primary. For flowmeter primaries with hard or soft rubber liners, sizes DN 125 (5) and larger, a conductive element is incorporated in the liner. This assures that the fluid is grounded. To comply with the EMC- and Low Voltage Regulations the connection box/converter must be grounded in addition to the meter tube of the flowmeter primary.
3.1.2
3.3
Installation Requirements
Pulse Output (Standard Calibration; 0.5% of rate): - Q>0.07 Rangemax 0.5 % of rate - Q<0.07 Rangemax 0.00035 Rangemax Rangemax = maximum flowrate for the flowmeter size 10 m/s Pulse Output (Optional Calibration; 0.25 % of rate): - Q>0.14 Rangemax 0.25 % of rate - Q<0.14 Rangemax 0.00035 Rangemax Rangemax = maximum flowrate for the flowmeter size 10 m/s
3 2 1
0,5% v. M. 0,25% v. M.
0 2 4 6 7 8 10 14 20 40 60 80 100 %
The following points must be observed for the installation: The meter tube must always be completely full. The flow direction must correspond to the identification if present. The maximum torque for all flange connections must be complied with. The devices must be installed without mechanical tension (torsion, bending). Flanged/wafer design flowmeters with coplanar counter flanges may only be installed with suitable seals. Use flange seals made from a compatible material for the fluid and fluid temperatures. Seals must not extend into the flow area since possible turbulence could influence the device accuracy. The pipeline may not exert any unallowable forces and torques on the device. Do not remove the plugs in the cable connectors until you are ready to install the electrical cable. Install the separate converter (MAG-XE) at a largely vibrationfree location. Do not expose the converter to direct sunlight or provide for appropriate sun protection where necessary.
Q Q max DN
0,2 0,4
0,6 0,8
10
X
Fig. 1 Y X Accuracy of rate in [%] Flow velocity v in [m/s]
G00006
D184S075U02
3.3.1
Electrode axis
3.3.4
Horizontal connections
Electrode axis (1) should be horizontal if at all possible or no more that 45 from horizontal.
Meter tube must always be completely full. Provide for a slight incline of the connection for degassing.
3
max. 45
Fig. 5
G00038
1
G00041
3.3.5
Fig. 2
3.3.2
Do not install the flowmeter at the highest point or in the drainingoff side of the pipeline, flowmeter runs empty, air bubbles can form (1). Provide for a siphon fluid intake for free inlets or outlets so that the pipeline is always full (2).
3 x DN 2 x DN DN = Flowmeter primary size Attention: For devices subject to calibration for commercial use, special conditions apply, see chapter "Approved EMF for custody transfer". Do not install fittings, manifolds, valves etc. directly in front of the meter tube (1). Butterfly valves must be installed so that the valve plate does not extend into the flowmeter primary. Valves or other turn-off components should be installed in the outlet pipe section (2). For compliance with the measuring accuracy, observe the inlet and outlet pipe sections.
2 1
G00040
Fig. 6
3.3.6
For strongly contaminated fluids, a bypass connection according to the figure is recommended so that operation of the system can continue to run without interruption the during the mechanical cleaning.
2
3xDN 2xDN
G00037
Fig. 3
G00042
Fig. 7
3.3.3
Vertical connections
Vertical installation for measurement of abrasive fluids, flow preferably from below to above.
3.3.7
For flowmeter primaries which are to be installed in the vicinity of pumps or other vibration generating equip-ment, the utilization of mechanical snubbers is advantageous.
G00039
G00043
Fig. 4
Fig. 8
3.3.8
Determine the arising pressure loss for use of flanged reducers (1): 1. Calculate the diameter ratio d/D. 2. Determine the flow velocity from the flow range nomograph (Fig. 10). 3. Read the pressure drop on the Y-axis in Fig. 10.
Fig. 9 d v p D
= Inside diameter of the flowmeter = Flow velocity [m/s] = Pressure drop [mbar] = Inside diameter of the pipeline
Fig. 10
Wechsel ein-auf zweispaltig
3.4
Meter Size 3 4 6 8 10 15 20 25 32 40 50 65 80 100 125 150 200 250 300 350 400 450 500 600 700 800 900 1000
Wechsel ein-auf zweispaltig
1/10 5/32 1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5 6 8 10 12 14 16 18 20 24 28 32 36 40
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME DIN ASME DIN ASME DIN ASME DIN ASME DIN ASME DIN ASME
Material PN 40 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar 40 bar SS1.4571[316Ti] or steel CL150, CL300 40 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar 16, 40 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar 40 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar 16, 40 bar SS1.4571[316Ti] or steel CL150, CL300 10 bar SS1.4571[316Ti] or steel CL150, CL300 16, 40 bar SS1.4571[316Ti] or steel CL150, CL300 SS1.4571[316Ti] 10, 16, 25, 40 bar or steel CL150, CL300 SS1.4571[316Ti] 10, 16, 25, 40 bar or steel CL150, CL300 SS1.4571[316Ti] 10, 16, 25, 40 bar or steel CL150, CL300 SS1.4571[316Ti] or steel SS1.4571[316Ti] or steel 10, 16, 25 bar CL150 10, 16, 25 bar CL150 16, 40 bar 40 bar
Connection dimensions for flange according to DIN2501 / EN10921 or ASME or JIS respectively.
3.5
Flowrate nomograph
The volumetric flowrate is a function of both the flow velocity and the flowmeter size. The flow range nomograph shows the flowrates which can be metered with a specific flowmeter size and also which flowmeter sizes are suitable for a specific flowrate. Example: Flowrate = 7 m3/h (maximum value = flow range end value). Suitable are flowmeter primary sizes DN 20 : 3/4 to DN 65 : 2-1/2 for flow velocities between 0.5 and 10 m/s.
Selectively with or without conformity evaluation per Category III, Module B1+D, Fluid Group 1
10 bar
Fig. 11
D184S075U02
3.6
3.6.2
Approvals
The design of the measurement instrument Electromagnetic volume flowrate totalizer with electrical counter has been approved by the National Institute for Science and Technology (PhysikalischTechnischen Bundesanstalt) in Braunschweig, Germany. The following approvals have been granted for the volume flowrate totalizer which consists of a flowmeter primary and a converter: 6.221 87.12 5.721 87.05 Electromagnetic volume flowrate totalizer with a Class A and B electrical counter for cold water and waste water Electromagnetic volume flowrate totalizer with electrical counter for liquids other than water
Approved flowmeter sizes for liquids other than water and chemical fluids
Flowmeter Size and Maximum Allowable Flowrates DN Qmax Liter/min 25 32 40 50 65 80 100 150 Selectively Selectively Selectively Selectively Selectively Selectively Selectively Selectively 60 ... 200 100 ... 400 150 ... 750 250 ... 1000 400 ... 2000 700 ... 3000 900 ... 4500 2000 ... 10000 In steps of In steps of In steps of In steps of In steps of In steps of In steps of In steps of 10 20 50 50 100 100 100 500
Appendix (EO6) or Appendix 5 (EO5) of the certification regulations of 1988 apply to the electromagnetic volume flowrate totalizer with electrical counter.
Certification
The electromagnetic volume flowrate totalizer is certified on the test stands in Gttingen, Germany which have been approved for certification calibrations. After the calibration has been completed, the parameters which impact the certification regulations, can only be changed in the presence of a certification agent.
3.6.1
DN
Minimum Flowrates and Fluids DN Minimum Flowrate Liter Fluid 25 20 Beer 32 20 Beer 40 20 Beer, Milk 50 200 Beer, Wort 65 500 Milk, Wort, Beer 80 500 Milk, Wort, Beer 100 2000 Brine, Wort 150 2000 Brine Min.flow range:approx. 2.5 m/s. Max. flow range approx. 10 m/s. The actual flow ranges must be in accord with the values listed in the tables. Subsequent range changes require a new calibration on an agency certified test stand.
3.6.3
25 32 40 40 65 80 100 125 150 000 250 300 350 400 500 600 700 800 900 1000
The following installation requirements are to be observed in each case: For flow metering in one flow direction: Cold/Waste Water In front of flowmeter primary After flowmeter primary 5 x DN 2 x DN Other Fluids (other than water) 10 x DN 5 x DN
For flow metering in both flow directions: Cold/Waste Water In front of flowmeter primary After flowmeter primary 5 x DN 5 x DN Other Fluids (other than water) 10 x DN 10 x DN
5 x DN (10 x DN)
Fig. 12
D184S075U02
Remark: Max. allow. fluid temperature for hard/soft rubber liners 90 C ( 194 F) Max. allow. fluid temperature for PTFE/ PFA liners 130 C (266 F)
4
4.1
Specifications:
Model DE41F, DE41W, DE43F, DE43W General specifications
Meter Size 15 ... 250 (1/2 ... 10") 300 ... 1000 (12 ... 40") 50 ... 250 (2 ... 10") 300 ... 1000 (12 ... 40") 10 ... 600 (3/8 ... 24") POperation mbar abs. 0 0 0 0 270 400 500 0 at TOperation* < 90 C (194 F) < 90 C (194 F) < 90 C (194 F) < 90 C (194 F) < 20 C (68 F) < 100 C (212 F) < 130 C (266 F) < 130 C (266 F)
4.1.1
Liner
Soft rubber
3 ... 100 (1/10 ... 4") *) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table Maximum Allowable Cleaning Temperature.
DN 450 ... 1000 (18 ... 40") Part Housing DN 3 ... 400(1/10 ... 16") DN 450 ... 1000 (18 ... 40") Connection box
25 77
-10 14
Standard Two-piece cast aluminum housing, painted, paint coat 60 m thick, RAL 9002 Welded steel construction, painted, paint coat 60 m thick, RAL 9002 Cast alum., painted, 60 m thick, frame: dark gray, RAL7012, cover: light gray, RAL 9002 SS 1.4301 [304] Polyamide
0 32
-20 -4
Storage Temperature
- 20 C (-4 F) ... +70 C (158 F)
G00045
Fig. 14 Y= X= -----Ambient temperature C/F Fluid temperature C/F Temperature range for COPA-XE Temperature range for MAG-XE
The following applies for compact design FXE4000 (COPA-XE): In the range of 10 - 55 Hz max. 0.15 mm deflection In the range of 55 -150 Hz max. 2 g acceleration The following applies for separate converter (MAG-XE): Converter In the range of 10 - 55 Hz max. 0.15 mm deflection Flowmeter primary In the range of 10 - 55 Hz max. 0.15 mm deflection In the range of 55 -150 Hz max. 2 g acceleration
Designs
The flanged flowmeters comply with the installation lengths defined in VDI/VDE 2641, ISO 13359 or DVGW (W420, Design WP, ISO 4064 short).
10
D184S075U02
ASME flange carbon steel to DN 300 (12") (CL150/300) to DN 1000 (40") (CL150)
PS [bar] 55 50 45 40 35 30 25 20 15 10 5 0 -30 -22
4.1.2
Limits for the allowable fluid temperature (TS) and allowable pressure (PS) are a function of the liner and flange materials of the flowmeter (see instrument name plate).
CL300
Max. temperature 90 C (194 F) for hard/soft rubber liners Max. temperature 130 C (266 F) for PTFE/PFA liners
DIN-Flange SS 1.4571 [316Ti] to DN 600 (24")
PS [bar] 45 40 35 30 25 20 15 10 5
0
CL150
-10 0 10 14 32 50
30 86
50 122
70 158
90 194
110 230
PN 40
Fig. 18
PN 25 PN 16 PN 10 -10 0 10 14 32 50 30 86 50 122 70 158 90 194 110 230 130 [C] TS 266 [F]
PN 10 10
TS -25 ... +130 C (-13 ... +266 F) -25 ... +130 C (-13 ... +266 F)
PS [bar] 10 10
-30 -22
Fig. 15 ASME Flange SS1.4571[316TI] to DN 300 (12) (CL150/300) to DN 1000 (40) (CL150)
PS [bar] 55 50 45 40 35 30 25 20 15 10 5 0 -30 -22
CL300
DN 700 (28) PN 16
CL150
DN 900 (36) PN 16 DN 800 (32) PN 16 DN 1000 (40) PN 16 DN 900 (36) PN 10 DN 800 (32) PN 10 DN 700 (28) PN 10 DN 1000 (40) PN 10
-10 0 10 14 32 50
30 86
50 122
70 158
90 194
110 230
G00024
PN 40
Fig. 17
A
Fig. 20
11
D184S075U02
4.1.3
12
D184S075U02
4.1.4
Dimensions [mm] 2)3) L 7) 200 200 200 200 200 200 200 200 200 200 250 250
F 243 243 243 243 243 250 250 256 267 267 289 299
E 181 181 181 181 181 188 188 194 205 205 227 237
Weight approx. [kg] COPA-XE MAG-XE 5 6 5 6 5.5 6.5 6 7 6,5 8 8 9 9 10 10 12 15 16 18 19 20 22 28 29 Weight approx. [kg]
Flanges according to ASME B16.5 (for the dimensions F, C, E see table DIN flanges)
Dimensions [mm] CL150 DN 3-8 10 15 20 25 32 40 50 65 80 100 125
1) 2) 3) 4)
CL300 D 96 96 96 118 124 134 156 165 191 210 254 280 ISO 13359 200 200 200 200 200 200 200 200 200 200 250 250
7) 8)
3)4)
Inch 1/8 ... 5/16 6) 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 4 5
6)
ABB (old installation length) 130 270 270 270 270 280 280 280 330 340 400 450
COPA-XE 6 6 6.5 7 8 9 10 12 16 19 28 36
Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases as follows: DN 3 ... 100 by 3 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases as follows: DN 3 ... 100 by 6 mm. If protection flanges (mounted on each ASME flange, old installation length) are installed, the L dimension increases as follows: DN 3 ... 80 by 20 mm DN 100 and larger by 25 mm Connection flange DN 10 Connection flange 1/2" New installation length DN 3 ... 8 now 200 mm! As replacement for the old installation length (130 mm) see Model DE21F /DE23F. For PFA liner and ASME flanges, only ISO installation lengths. Connection dimensions according to EN 1092-1. For DN 65, PN 16 according to EN 1092-1 please order PN 40.
5) 6) 7) 8) 9)
13
Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE) Flange DN 150 ... 400 (5 ... 16")
MAG-XE DE41F COPA-XE DE43F
83,5 88 88 35
D184S075U02
MAG-XE DE41F
COPA-XE DE43F
203 120
67
L*
95
120
G00053
Tolerance: L* DN 150 ... 200 +0 / -3; DN 250 400 +0 / -5; Dimensions in mm Fig. 22
45
Weight approx. [kg] F 346 372 372 401 401 424 424 466 466 466 466 E 265 310 310 339 339 362 362 404 404 404 404 COPA-XE 40 66 66 105 105 120 120 145 145 179 179 MAG-XE 38 64 64 103 103 118 118 143 143 177 177
D 285 340 340 395 405 445 460 505 520 565 580
L 300 350 350 450 450 500 500 550 550 600 600
10-16 10 16 10 16 10 16 10 16 10 16
Flanges according to ASME B16.5 (for the dimensions F, E see table DIN flanges)
CL150 DN 150 200 250 300 350 400
1) 2) 3) 4)
Dimensions [mm] CL300 D 318 381 445 521 ISO 13359 300 350 450 500 550 600
Inch 6 8 10 12 14 16
ABB (old installation length) 450 500 550 620 650 700
Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases by 5 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases by 10 mm. If protection flanges (mounted on each ASME flange, old installation length) are installed, the L dimension by 25 mm.
14
Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE) Flange DN 450 ... 1000 (18 ... 40")
MAG-XE DE41F
88
D184S075U02
COPA-XE DE43F
MAG-XE DE41F
88 35
67
COPA-XE DE43F
G1
D L*
G00054
Tolerance: L* DN 450 ... 500 +0 / -5; DN 600 ... 1000 +0 / -10; Dimensions in mm Fig. 23
Weight approx. [kg] COPA-XE MAG-XE 196,0 191,0 276,0 319,0 409,0 487,0 579,0 243,0 315,0 405,0 483,0 575,0
Flanges according to ASME B16.5 (for the dimensions F see table DIN flanges)
Dimensions [mm] CL150 DN 450 500 600
1) 2) 3) 4)
Inch 18 20 24
CL300 approx. kg -
Other press. ratings upon request. If a ground ring (mounted on one side of the meter) is installed, the L dimension increases by 5 mm. If protection rings (mounted on both sides of the meter) are installed, the L dimension increases by 10 mm. If protection flanges (mounted on each ASME flange, old installation length) are installed, the L dimension by 25 mm.
15
D184S075U02
4.1.5
MAG-XE DE41W
COPA-XE DE43W
203 120
88
88 35
67
95
120
G00060
Abb. 24 Dimensions in mm Dimensions [mm] DN 3-10 15 25 32 40 50 65 80 100 PN 16 16 16 16 16 16 16 16 16 L 69 69 91 99 104 119 103 103 133 B 75 75 95 103 112 130 146 163 190 C 62 62 73 78 82 90 104 110 130 E 157 157 168 173 177 185 199 205 225 F 281 281 292 297 301 337 365 377 417 Weight approx. [kg] COPA-XE 3,0 3,0 4,5 5,0 6,0 6,5 8,0 9,0 10,0 MAG-XE 2,0 2,0 3,5 4,0 5,0 5,5 7,0 8,0 9,0
16
D184S075U02
4.1.6
A
Ordering Information
Variant digit No. 1-6 7 8 9 10 11 12 13 14 15 16 17 18
Electromagnetic Flowmeter FXE4000-DE43F (COPA-XE) compact design with welded flange Liner material PFA PFA PFA PFA PFA PFA PFA PFA PFA PFA PFA PFA PFA PFA PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE PTFE Measuring electrodes material Hastelloy C-4 (2.4610) Hastelloy B-3 (2.4600) SST (1.4571) Titanium Tantalum SST (1.4539) Platinum-Iridium Hastelloy C-4 (2.4610) Hastelloy B-3 (2.4600) SST (1.4571) Titanium Tantalum SST (1.4539) Platinum-Iridium
Catalog No.
DE43FP P P P P P P P P P P P P P T T T T T T T T T T T T T T T T T T T T 0 0 0 0 1 1 2 2 3 4 5 6 8 1 1 1 2 2 3 4 5 6 8 1 1 1 2 2 3 3 4 4 5 6 2) 3 4 6 8 0 5 0 5 2 0 0 5 0 H 0 5 0 5 2 0 0 5 0 H Q F H F H F H F H H H B S M T F P O N E I Q R G
Meter size DN 3 1/10 in 1) 3) DN 4 5/32 in 1) 3) DN 6 1/4 in 1) 3) DN 8 5/16 in 1) 3) DN 10 3/8 in 1) DN 15 1/2 in 1) DN 20 3/4 in 1) DN 25 1 in 1) DN 32 1 1/4 in 1) DN 40 1 1/2 in 1) DN 50 2 in 1) DN 65 2 1/2 in 1) DN 80 3 in 1) DN 100 4 in 1) DN 10 3/8 in DN 15 1/2 in DN 20 3/4 in DN 25 1 in DN 32 1 1/4 in DN 40 1 1/2 in DN 50 2 in DN 65 2 1/2 in DN 80 3 in DN 100 4 in DN 125 5 in DN 150 6 in DN 200 8 in DN 250 10 in DN 300 12 in DN 350 14 in DN 400 16 in [18 in] (only ASME CL 150 DN 450 DN 500 20 in DN 600 24 in Grounding electrodes without without without without without without without with with with with with with with
Continued on next page 1) PFA with ASME flanges only ISO-laid length (see pressure rating) 2) Grounding electrodes available only for meter size DN 3...DN 300 3) DN 3 - 8 new laid length: 200 mm (For replacement with old laid length 130 mm please use model DE23F) Note to the 3A conformity If 3A conformity is desired, please order model DE23
17
D184S075U02
Variant digit No. 1-6 11 12 13 14 15 16 17 18 19 20 21 22 Electromagnetic Flowmeter Catalog No. DE43FFXE4000-DE43F (COPA-XE) compact design with welded flange 3) Pressure rating PN 10 ISO laid length C 4) D PN 16 ISO laid length E PN 25 ISO laid length F PN 40 Standard for DN 3...DN 80 ISO laid length K JIS K10 ISO laid length ASME CL 150 <= DN 600 (24 in) old laid length, only for replacement P old laid length, only for replacement Q ASME CL 300 <= DN 300 (12 in) ISO laid length R ASME CL 150 <= DN 600 (24 in) ISO laid length S ASME CL 300 <= DN 400 (16 in) Material of process connection Steel Standard from DN 20 1 SST 1.4571 Standard for DN 3...DN 15 3 Accessories without A Protection ring 1.4571 (on both sides) 5) B Grounding ring 1.4571 (fastened on one side) 5) C 6) D Protection flange 1.4571 (on both sides) Temperature range Standard design <= 130 C (266 F) S Certificates without A Material certificate per EN 10204 3.1B + pressure test per AD 2000 D G Pressure test per AD 2000 F Inspection certificate per EN 10204 3.1B K without DGRL cerificate 7) Calibration certificates without A Custody transfer, cold water / waste water (DN 25...DN 600 1 in24 in) B (DN 25...DN 150 1 in6 in) C Custody transfer, fluids except water Type of protection IP 67 2 Power supply 100...230 V AC N 16.8...26.4 V AC / 16.8...31.2 V DC K Display illuminated, with magnetic stick operation D Input / output options Current output/ +Pulse output active/ +Contact input/ +Contact output 0 1 Current output/ +Pulse output active/ +Contact input/ +Contact output/ +HART protocol 0 2 Current output/ +Pulse output passive/ +Contact input/ +Contact output 0 3 Current output/ +Pulse output passive/ +Contact input/ +Contact output/ +HART protocol 0 4 0 5 Current output/ +Pulse output passive/ +Contact output/ +RS 485 0 6 Pulse output passive/ +Contact output/ +PROFIBUS DP PROFIBUS PA 3.0 1 4 FOUNDATION Fieldbus 1 5 PROFIBUS PA 3.0 with M12 plug 1 6 Material of converter housing / cable entry Aluminium M20 x 1.5 0 Aluminium 1/2 in NPT 2 Aluminium PF 1/2 in 3 3) Connection dimensions for flanges acc. to DIN 2501 or ASME B16.5 or JIS B2210-10K Continued on next page 4) DN 65/ PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40 5) Protection ring on both and grounding ring fastened on one side to flange, only possible for primary <= DN 300 and PTFE/PFA-lining 6) Only possible with ASME flanges old laid length (pressure rating codes P,Q) and primary with PTFE/PFA-lining 7) possible >= DN500 (20 in)
18
D184S075U02
Variant digit No. Electromagnetic Flowmeter Catalog No. FXE4000-DE43F (COPA-XE) compact design with welded flange Name plate German English French (specified by ABB) Design level Electrode design Standard Excitation frequency 6 1/4 Hz (DN 3...DN 600 1/10 in...24 in) 12 1/2 Hz (DN 3...DN 100 1/10 in4 in) (DN 3...DN 600 1/10 in...24 in) 7 1/2 Hz (DN 3...DN 100 1/10 in4 in) 15 Hz (DN 3...DN 20 1/10 in3/4 in) 25 Hz
1-6
15 16 17 18 19 20 21 22 23 24 25 26
DE43FG E F * 1 1 2 3 4 5
Ordering information
Electromagnetic Flowmeter FXE4000-DE43F (COPA-XE) compact design with welded flange Liner material Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Hard rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber Soft rubber
Variant digit No. 1-6 7 8 9 10 11 12 13 14 15
Catalog No. Meter size DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 DN 700 DN 800 DN 900 DN 1000 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 DN 200 DN 250 DN 300 DN 350 DN 400 DN 450 DN 500 DN 600 DN 700 DN 800 DN 900 DN 1000
DE43F-
1/2 in 3/4 in 1 in 1 1/4 in 1 1/2 in 2 in 2 1/2 in 3 in 4 in 5 in 6 in 8 in 10 in 12 in 14 in 16 in [18 in] (only ASME CL 150) 20 in 24 in 28 in 32 in 36 in 40 in 2 in 2 1/2 in 3 in 4 in 5 in 6 in 8 in 10 in 12 in 14 in 16 in [18 in] (only ASME CL 150) 20 in 24 in 28 in 32 in 36 in 40 in
H H H H H H H H H H H H H H H H H H H H H H H S S S S S S S S S S S S S S S S S S
1 2 2 3 4 5 6 8 1 1 1 2 2 3 3 4 4 5 6 7 8 9 1 5 6 8 1 1 1 2 2 3 3 4 4 5 6 7 8 9 1
5 0 5 2 0 0 5 0 H Q F H F H F H F H H H H H T 0 5 0 H Q F H F H F H F H H H H H T
Continued on next page Note to the 3A conformity If 3A conformity is desired, please order model DE23
19
D184S075U02
Variant digit No. 1-6 Electromagnetic Flowmeter Catalog No. DE43FFXE4000-DE43F (COPA-XE) compact design with welded flange 1) Measuring electrodes material Grounding electrodes SST (1.4571) without Hastelloy C-4 (2.4610) without Hastelloy B-3 (2.4600) without Titanium without Tantalum without without SST (1.4539) Platinum-Iridium without with SST (1.4571) with Hastelloy C-4 (2.4610) with Hastelloy B-3 (2.4600) Titanium with Tantalum with with SST (1.4539) Platinum-Iridium with 2) Pressure rating PN 10 ISO laid length 3) PN 16 ISO laid length PN 25 ISO laid length PN 40 Standard for DN 15...DN 80 ISO laid length JIS K10 ISO laid length old laid length, only for replacement ASME CL 150 <= DN 600 (24 in) old laid length, only for replacement ASME CL 300 <= DN 300 (12 in) ISO laid length ASME CL 150 <= DN 600 (24 in) ASME CL 300 <= DN 400 (16 in) ISO laid length Material of process connection Steel Standard from DN 20 SST 1.4571 Standard for DN 15 Accessories without Temperature range Standard design <= 90 C (194F) Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B without DGRL certificate Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 600 1 in24 in) (DN 25...DN 150 1 in6 in) Custody transfer, fluids except water Type of protection IP 67 Power supply 100...230 V AC 16.8...26.4 V AC / 16.8...31.2 V DC
10 11 12 13 14 15 16 17 18
S H B M T F P E O N I Q R G C D E F K P Q R S 1 3 A S A D G F K A B C 2 N K
4)
Continued on next page 1) Grounding electrodes available only for meter size DN 15...DN 300 Grounding electrodes (conductive flag) are standard available in meters lined with hard or soft rubber in meter size DN 125...DN 1000. Additional grounding electrodes or rings are not applicable. 2) Connection dimensions for flanges acc. to DIN 2501/EN 1092-1 or ASME B16.5 or JIS B2210-10K 3) DN 65/PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40 4) possible >= DN500 (20 in)
20
D184S075U02
Variant digit No. 1-6 18 19 20 21 22 23 24 25 26 Electromagnetic Flowmeter Catalog No. DE43FFXE4000-DE43F (COPA-XE) compact design with welded flange Display illuminated, with magnetic stick operation D Input / output options Current output/ +Pulse output active/ +Contact input/ +Contact output 0 1 0 2 Current output/ +Pulse output active/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact input/ +Contact output 0 3 Current output/ +Pulse output passive/ +Contact input/ +Contact output/ +HART protocol 0 4 0 5 Current output/ +Pulse output passive/ +Contact output/ +RS 485 (ASCII) Pulse output passive/ +Contact output/ +PROFIBUS DP 0 6 PROFIBUS PA 3.0 1 4 FOUNDATION Fieldbus 1 5 1 6 PROFIBUS PA 3.0 with M12 plug Material of converter housing / cable entry Aluminium M20 x 1.5 0 Aluminium 1/2 in NPT 2 Aluminium PF 1/2 in 3 Name plate German G E English French F (specified by ABB) * Design level Electrode design Standard 1 Excitation frequency 6 1/4 Hz (DN 3...DN 1000 1/10 in40 in) 1 (DN 3...DN 100 1/10 in4 in) 2 12 1/2 Hz (DN 3...DN 1000 1/10 in40 in) 3 7 1/2 Hz (DN 3...DN 100 1/10 in4 in) 4 15 Hz 25 Hz (DN 3...DN 20 1/10 in3/4 in) 5
21
D184S075U02
Variant digit No. 1-6 Electromagnetic Flowmeter (MAG-XE) Catalog No. DE41FFXE4000-DE41F remote design with welded flange Liner material Meter size PFA DN 3 1/10 in 1) 3) PFA DN 4 5/32 in 1) 3) PFA DN 6 1/4 in 1) 3) PFA DN 8 5/16 in 1) 3) PFA DN 10 3/8 in 1) PFA DN 15 1/2 in 1) PFA DN 20 3/4 in 1) PFA DN 25 1 in 1) PFA DN 32 1 1/4 in 1) PFA DN 40 11 1) PFA DN 50 2 in 1) PFA DN 65 2 1/2 in 1) PFA DN 80 3 in 1) PFA DN 100 4 in 1) PTFE DN 10 3/8 in PTFE DN 15 1/2 in PTFE DN 20 3/4 in PTFE DN 25 1 in PTFE DN 32 1 1/4 in PTFE DN 40 1 1/2 in PTFE DN 50 2 in PTFE DN 65 2 1/2 in PTFE DN 80 3 in PTFE DN 100 4 in PTFE DN 125 5 in PTFE DN 150 6 in PTFE DN 200 8 in PTFE DN 250 10 in PTFE DN 300 12 in PTFE DN 350 14 in PTFE DN 400 16 in PTFE DN 450 [18 in] (only ASME CL 150) PTFE DN 500 20 in PTFE DN 600 24 in Grounding electrodes Measuring electrodes material Hastelloy C-4 (2.4610) without Hastelloy B-3 (2.4600) without without SST (1.4571) Titanium without Tantalum without without SST (1.4539) Platinum-Iridium without Hastelloy C-4 (2.4610) with Hastelloy B-3 (2.4600) with with SST (1.4571) Titanium with Tantalum with with SST (1.4539) Platinum-Iridium with
10 11 12 13 14 15 16 17
P P P P P P P P P P P P P P T T T T T T T T T T T T T T T T T T T T
0 0 0 0 1 1 2 2 3 4 5 6 8 1 1 1 2 2 3 4 5 6 8 1 1 1 2 2 3 3 4 4 5 6 2)
1) PFA with ASME flanges only ISO-laid length (see pressure rating) 2) Grounding electrodes available only for meter size DN 3...DN 300 3) DN 3 - 8 new laid length: 200 mm (For replacement with old laid length 130 mm please use model DE23F) Note to the 3A conformity If 3A conformity is desired, please order model DE21
22
D184S075U02
Variant digit No. 1-6 11 12 13 14 15 16 17 18 19 20 21 Electromagnetic Flowmeter (MAG-XE) Catalog No. DE41FFXE4000-DE41F remote design with welded flange 3) Pressure rating PN 10 ISO laid length C 4) D PN 16 ISO laid length PN 25 ISO laid length E F PN 40 Standard for DN 3...DN 80 ISO laid length K JIS K10 ISO laid length ASME CL 150 <= DN 600 (24 in) old laid length, only for replacement P ASME CL 300 <= DN 300 (12 in) old laid length, only for replacement Q ASME CL 150 <= DN 600 (24 in) ISO laid length R ISO laid length S ASME CL 300 <= DN 400 (16 in) Material of process connection Steel Standard from DN 20 1 SST 1.4571 Standard for DN 3...DN 15 3 Accessories without A Protection ring 1.4571 (on both sides) 5) B Grounding ring 1.4571 (fastened on one side) 5) C 6) D Protection flange 1.4571 (on both sides) Temperature range Standard design <= 130 C (266 F) S Certificates without A Material certificate per EN 10204 3.1B + pressure test per AD 2000 D G Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B F K without DGRL certificate 7) Calibration certificates without A Custody transfer, cold water / waste water (DN 25...DN 600 1 in24 in) B (DN 25...DN 150 1 in6 in) C Custody transfer, fluids except water Type of protection Cable entry IP 67 Thread for screw-type conduit fitting M20 x 1.5 2 IP 67 Thread for screw-type conduit fitting NPT 1/2 in 4 5 IP 67 Thread for screw-type conduit fitting PF 1/2 in 7 IP 68 Thread for screw-type conduit fitting M20 x 1.5 8 IP 68 Cabel connected and potted Connection box Name plate German G E English French F (specified by ABB) * Design level Electrode design Standard 1 Excitation frequency 6 1/4 Hz (DN 3...DN 600 1/10 in...24 in) 1 (DN 3...DN 100 1/10 in4 in) 2 12 1/2 Hz (DN 3...DN 600 1/10 in...24 in) 3 7 1/2 Hz (DN 3...DN 100 1/10 in4 in) 4 15 Hz (DN 3...DN 20 1/10 in3/4 in) 5 25 Hz 3) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K 4) DN 65/ PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40 5) Protection flange on both and grounding ring fastened on one side to flange, only possible for primary <= DN 300 and PTFE/PFA-lining 6) Only possible with ASME flanges old laid length (pressure rating codes P,Q) and primary with PTFE/PFA-lining 7) possible >= DN500 (20 in) Related Converter FXE4000-E4
23
D184S075U02
Electromagnetic Flowmeter (MAG-XE) FXE4000-DE41F remote design with welded flange Liner material Meter size Hard rubber DN 15 DN 20 Hard rubber Hard rubber DN 25 DN 32 Hard rubber DN 40 Hard rubber DN 50 Hard rubber DN 65 Hard rubber Hard rubber DN 80 DN 100 Hard rubber DN 125 Hard rubber DN 150 Hard rubber DN 200 Hard rubber Hard rubber DN 250 DN 300 Hard rubber DN 350 Hard rubber Hard rubber DN 400 DN 450 Hard rubber DN 500 Hard rubber Hard rubber DN 600 DN 700 Hard rubber DN 800 Hard rubber DN 900 Hard rubber DN 1000 Hard rubber Soft rubber DN 50 DN 65 Soft rubber DN 80 Soft rubber DN 100 Soft rubber Soft rubber DN 125 DN 150 Soft rubber Soft rubber DN 200 DN 250 Soft rubber DN 300 Soft rubber DN 350 Soft rubber DN 400 Soft rubber DN 450 Soft rubber DN 500 Soft rubber DN 600 Soft rubber DN 700 Soft rubber DN 800 Soft rubber DN 900 Soft rubber DN 1000 Soft rubber
1-6
10 11 12 13
Catalog No. 1/2 in 3/4 in 1 in 1 1/4 in 1 1/2 in 2 in 2 1/2 in 3 in 4 in 5 in 6 in 8 in 10 in 12 in 14 in 16 in [18 in] (only ASME CL 150) 20 in 24 in 28 in 32 in 36 in 40 in 2 in 2 1/2 in 3 in 4 in 5 in 6 in 8 in 10 in 12 in 14 in 16 in [18 in] (only ASME CL 150) 20 in 24 in 28 in 32 in 36 in 40 in
DE41FH H H H H H H H H H H H H H H H H H H H H H H S S S S S S S S S S S S S S S S S S 1 2 2 3 4 5 6 8 1 1 1 2 2 3 3 4 4 5 6 7 8 9 1 5 6 8 1 1 1 2 2 3 3 4 4 5 6 7 8 9 1 5 0 5 2 0 0 5 0 H Q F H F H F H F H H H H H T 0 5 0 H Q F H F H F H F H H H H H T
24
D184S075U02
Variant digit No. 1-6 Electromagnetic Flowmeter (MAG-XE) Catalog No. DE41FFXE4000-DE41F remote design with welded flange 1) Measuring electrodes material Grounding electrodes SST (1.4571) without Hastelloy C-4 (2.4610) without without Hastelloy B-3 (2.4600) Titanium without Tantalum without SST (1.4539) without Platinum-Iridium without SST (1.4571) with with Hastelloy C-4 (2.4610) with Hastelloy B-3 (2.4600) Titanium with Tantalum with with SST (1.4539) Platinum-Iridium with 2) Pressure rating PN 10 ISO laid length 3) PN 16 ISO laid length PN 25 ISO laid length PN 40 Standard for DN 15...DN 80 ISO laid length JIS K10 ISO laid length ASME CL 150 <= DN 600 (24 in) old laid length, only for replacement old laid length, only for replacement ASME CL 300 <= DN 300 (12 in) ISO laid length ASME CL 150 <= DN 600 (24 in) ISO laid length ASME CL 300 <= DN 400 (16 in) Material of process connection Steel Standard from DN 20 SST 1.4571 Standard for DN 15 Accessories without Temperature range Standard design <= 90 C (194F) Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B without DGRL certificate Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 1000 1 in40 in) (DN 25...DN 150 1 in6 in) Custody transfer, fluids except water
10 11 12 13 14 15 16
S H B M T F P E O N I Q R G C D E F K P Q R S 1 3 A S A D G F K A B C
4)
Continued on next page 1) Grounding electrodes available only for meter size DN 15...DN 300 Grounding electrodes (conductive flag) are standard available in meters lined with hard or soft rubber in meter size DN 125...DN 1000. Additional grounding electrodes or rings are not applicable. 2) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K 3) DN 65/ PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40 4) possible >= DN500 (20 in) Note to the 3A conformity If 3A conformity is desired, please order model DE21
25
D184S075U02
Variant digit No. Electromagnetic Flowmeter (MAG-XE) Catalog No. FXE4000-DE41F remote design with welded flange Type of protection Cable entry IP 67 Thread for screw-type conduit fitting M20 x 1.5 IP 67 Thread for screw-type conduit fitting NPT 1/2 in IP 67 Thread for screw-type conduit fitting PF 1/2 in IP 68 Thread for screw-type conduit fitting M20 x 1.5 IP 68 Cabel connected and potted Connection box Name plate German English French (specified by ABB) Design level Electrode design Standard Excitation frequency 6 1/4 Hz (DN 3...DN 1000 1/10 in40 in) (DN 3...DN 100 1/10 in4 in) 12 1/2 Hz (DN 3...DN 1000 1/10 in40 in) 7 1/2 Hz (DN 3...DN 100 1/10 in4 in) 15 Hz (DN 3...DN 20 1/10 in3/4 in) 25 Hz
1-6
15 16 17 18 19 20 21
DE41F2 4 5 7 8 G E F * 1 1 2 3 4 5
26
D184S075U02
Variant digit No. 1-6 Electromagnetic Flowmeter Catalog No. DE43WFXE4000-DE43W (COPA-XE) compact design wafer type Liner material Meter size PFA DN 3 1/10 in PFA DN 4 5/32 in PFA DN 6 1/4 in PFA DN 8 5/16 in PTFE DN 10 3/8 in PTFE DN 15 1/2 in PTFE DN 25 1 in PTFE DN 32 1 1/4 in PTFE DN 40 1 1/2 in PTFE DN 50 2 PTFE DN 65 2 1/2 in PTFE DN 80 3 in PTFE DN 100 4 in Grounding electrodes Measuring electrodes material Hastelloy C-4 (2.4610) without Hastelloy B-3 (2.4600) without without SST (1.4571) Titanium without Tantalum without without SST (1.4539) Platinum-Iridium without with Hastelloy C-4 (2.4610) with Hastelloy B-3 (2.4600) SST (1.4571) with Titanium with Tantalum with with SST (1.4539) Platinum-Iridium with Pressure rating PN 16 ASME CL 150 JIS K10 Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 100 1 in4 in) (DN 25...DN 100 1 in4 in) Custody transfer, fluids except water Type of protection IP 67 Power supply 100...230 V AC 16.8...26,4 V AC / 16.8...31,2 V DC Display illuminated, with magnetic stick operation
10 11 12 13 14 15 16 17
P P P P T T T T T T T T T
0 0 0 0 1 1 2 3 4 5 6 8 1 1)
3 4 6 8 0 5 5 2 0 0 5 0 H H B S M T F P O N E I Q R G 2) D P K A D G F A B C 2 N K D
Continued on next page 1) Grounding electrodes available only for meter size DN 3...DN 300 2) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K Accessories see table H
27
D184S075U02
Variant digit No. 1-6 13 14 15 Electromagnetic Flowmeter Catalog No. DE43WFXE4000-DE43W (COPA-XE) compact design wafer type Input / output options Current output/ +Pulse output active/ +Contact input/ +Contact output Current output/ +Pulse output active/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact input/ +Contact output Current output/ +Pulse output passive/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact output/ +RS 485 Pulse output passive/ +Contact output/ +PROFIBUS DP PROFIBUS PA 3.0 FOUNDATION Fieldbus PROFIBUS PA 3.0 with M12 plug Material of converter housing / cable entry Aluminium M20 x 1.5 Aluminium 1/2 NPT Aluminium PF 1/2 in Name plate German English French (specified by ABB) Design level Electrode design Standard Excitation frequency 6 1/4 Hz (DN 3...DN 100 1/10 in4 in) 12 1/2 Hz (DN 3...DN 100 1/10 in4 in) 7 1/2 Hz (DN 3...DN 100 1/10 in4 in) (DN 3...DN 100 1/10 in4 in) 15 Hz (DN 3...DN 15 1/10 in1/2 in) 25 Hz
16 17 18 19 20 21 22 23
0 0 0 0 0 0 1 1 1
1 2 3 4 5 6 4 5 6 0 2 3 G E F * 1 1 2 3 4 5
28
D184S075U02
Variant digit No. 1-6 Electromagnetic Flowmeter (MAG-XE) Catalog No. DE41WFXE4000-DE41W remote design wafer type Liner material Meter size PFA DN 3 1/10 in PFA DN 4 5/32 in PFA DN 6 1/4 in PFA DN 8 5/16 in PTFE DN 10 3/8 in PTFE DN 15 1/2 in PTFE DN 25 1 in PTFE DN 32 1 1/4 in PTFE DN 40 1 1/2 in PTFE DN 50 2 PTFE DN 65 2 1/2 in PTFE DN 80 3 in PTFE DN 100 4 in Grounding electrodes Measuring electrodes material Hastelloy C-4 (2.4610) without Hastelloy B-3 (2.4600) without without SST (1.4571) Titanium without Tantalum without without SST (1.4539) Platinum-Iridium without Hastelloy C-4 (2.4610) with with Hastelloy B-3 (2.4600) with SST (1.4571) Titanium with Tantalum with SST (1.4539) with Platinum-Iridium with Pressure rating PN 16 ASME CL 150 JIS K10 Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 100 1 in4 in) (DN 25...DN 100 1 in4 in) Custody transfer, fluids except water
10 11 12 13 14 15 16
P P P P T T T T T T T T T
0 0 0 0 1 1 2 3 4 5 6 8 1 1)
3 4 6 8 0 5 5 2 0 0 5 0 H H B S M T F P O N E I Q R G 2) D P K A D G F A B C
Continued on next page 1) Grounding electrodes available only for meter size DN 3...DN 300 2) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K Accessories see table H Related Converter FXE4000-E4
29
D184S075U02
2 4 5 7 8 G E F * 1 1 2 3 4 5
30
4.2 4.2.1
3 ... 100 0 < 130 C (266 F) (1/10 ... 4") *) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table Maximum Allowable Cleaning Temperature.
Standard Cast alum., painted, frame paint coat: dark gray, RAL7012, cover: light gray, RAL 9002 SS 1.4301 [304] SS 1.4301 [304] Polyamide
Gasket Material
Process Connection Wafer design Weld stubs, food ind. fittings, Tri-Clamp, external threads Housing gasket Gasket Material None EPDM (Ethylene-Propylene) with FDA approval, silicone with FDA approval Silicone
Storage Temperature
25 77
-25 -13 0 32 -20 -4 50 122 130 [C] 266 [F]
Fig. 25 Y= X= -----Ambient temperature C/F Fluid temperature C/F Temperature range for COPA-XE Temperature range for MAG-XE
PFA
31
D184S075U02
4.2.2
Material load for devices with variable process connections DN3 ... 100 (1/10 ... 4") Model DE21_/DE23_
Meter Size 3 ... 50 (1/10 ... 2") 65 ... 100 (2 1/2 ... 4") 3 ... 40 (1/10 ... 1 1/2") 50, 80 (2", 3") 65, 100 (2 1/2", 4") 3 ... 40 (1/10 ... 1 1/2") 50, 80 (2", 3") 65, 100 (2 1/2", 4") 3 ... 50 (1/10 ... 2") 65 ... 100 (2 1/2 ... 4") 3 ... 100 (1/10 ... 4") 3 ... 25 (1/10 ... 1") PSmax [bar] 40 16 40 16 10 40 16 10 16 10 10 10 -25 C (-13 F) -25 C (-13 F) -25 C (-13 F) 121 C (250 F) 130 C (266 F) 130 C (266 F) -25 C (-13 F) 130 C (266 F) -25 C (-13 F) 130 C (266 F) -25 C (-13 F) 130 C (266 F) TSmin TSmax
4.2.4
PS
[bar] 45 40 35 30 25 20 15 10 5 0
Weld stubs
PN 40/CL300
Tri-Clamp per DIN 32676 Tri-Clamp per ASME 32676 External ISO 228 threads
PN 25 PN 16/CL150 PN 10
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130* [C] -22 -4 14 32 50 68 86 140 122 140 158 176 194 212 230 248 266 [F]
TS
G00049
4.2.3
Fig. 28 *) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see table Maximum Allowable Cleaning Temperature.
PN 40
PN 25 PN 16 PN 10 -10 0 10 14 32 50 30 86 50 122 70 158 90 194 110 230 130 [C] TS 266 [F]
-30 -22
G00020
CL300
CL150
-10 0 10 14 32 50
30 86
50 122
70 158
90 194
110 230
Fig. 27
32
D184S075U02
4.2.5
MAG-XE DE21F
COPA-XE DE23F
203 120
G1
71
157
L*
G00062
Flanges according to ASME B16.5 (for the dimensions F, G and G1 see table DIN flanges)
Dimensions [mm] CL150 DN 3-8 10 15 20 25 32 40
1) 2)
Weight approx. [kg] COPA-XE MAG-XE L 130 200 200 200 200 200 200 G 258 258 258 266 278 288 296 G1 172 172 172 180 192 202 210 CL150 approx. kg 3,5 3,5 3,5 4 4,5 4,5 5 CL300 approx. kg 3,5 3,5 3,5 4 4,5 4,5 5 CL150 approx. kg 1,5 1,5 1,5 1,5 2,0 2,5 3 CL300 approx. kg 1,5 1,5 1,5 1,5 2,0 2,5 3
1)
If a ground ring is required, L +3 mm material upon request. The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing. Dimensions for stainless steel converter housing see page 40.
120
104 80
80 41
33
D184S075U02
MAG-XE DE21F
COPA-XE DE23F
203 120
104 80
80 41
71
G1
A L*
d4 D
D
G00063
Flanges according to ASME B16.5 (for the dimensions F, d4 and A see table DIN flanges)
Dimensions [mm] CL150 DN 50 65 80 100 Inch 2 2 1/2 3 4 D 152 178 191 229 CL300 D 165 191 210 254 L 200 200 200 250 G 207 215 224 237 G1 161 175 181 201 Weight approx. [kg] COPA-XE MAG-XE CL150 CL300 CL150 CL300 approx. approx. approx. approx. kg kg kg kg 10,0 10,0 8,0 8,0 13,0 15,0 21,0 13,0 15,0 21,0 10,0 12,0 18,0 10,0 12,0 18,0
If a ground ring is required, L +3 mm material upon request. The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing. Dimensions for stainless steel converter housing see page 40.
34
120
45
D184S075U02
4.2.6
PN
1)
A* 64
C 50
Di 3 4 6 8 10 13 18 24 30 36
68
54 63 73 82
43 48 53 57
Installation lengths with 2 ground rings L + 3 mm only DN 3 ... 8 3) Bracket (option) The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing. Dimensions for stainless steel converter housing see page 40.
35
Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE) Wafer Design DN 50 ... 100 (2 ... 4")
COPA-XE DE23W
83,5
D184S075U02
MAG-XE DE21W
COPA-XE DE23W
203 120
MAG-XE DE21W
104 80
71
Di
A* L
G00068
G1
120
45
80 41
Weight approx. [kg] D 100 116 133 160 E 185 199 205 225 F 50 58 66,5 80 G 297 319 334 367 G1 214 236 251 284 COPA-XE 6,5 7,0 8,5 11,0 MAG-XE 4,0 4,5 6,5 8,5
1)
A* 112 99 99 129
A -
Di 47 62 74 96
Installation lengths with 2 ground rings L + 3 mm The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing. Dimensions for stainless steel converter housing see page 40.
36
D184S075U02
4.2.7
Fig. 33 (Dimensions in mm) Dimensions [mm] DN 3-10 15 20 25 32 40 PN 10 10 10 10 10 10 A 37 37 42 54 62 67 D 44 44 63 63 78 78 F* 39 39 43 48 53 57 G* 258 258 266 378 388 396 G1* 172 172 180 192 202 210 Weight approx. [kg] COPA-XE 3,5 3,5 4 4,5 4,5 5
1)
* With the mounting element, the dimension G, G1 and F increase by 10.5 mm, installation lengths with process connection see page 39. 1) plus process connection weights see page 39. 2) Bracket (option) The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing Dimensions for stainless steel converter housing see page 40.
37
Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE) Variable Process connections DN 50 ... 100 (2 ... 4")
COPA-XE DE23_
83.5
D184S075U02
MAG-XE DE21_
COPA-XE DE23_
203 120
MAG-XE DE21_
G1
71
120
104 80
80 41
45
DN 65
2)
F
5,5 60 A
110
DN 80 ... 100
G00070
Fig. 34 (Dimensions in mm) Dimensions [mm] DN 50 65 80 100 PN 10 10 10 10 A 128 114 114 114 D 100 116 133 160 E 185 199 205 225 F* 50 58 67 80 G* 297 319 334 367 G1* MAG-XE 214 236 251 284 Weight approx. [kg] COPA-XE 6,5 7 9 11
1)
* With the mounting element, the dimension G, G1 and F increase by 10.5 mm, installation lengths with process connection see page 39. 1) plus process connection weights see page 39. 2) Mounting element (option) The dimensions stated above for COPA-XE refer to the design with diecast aluminum converter housing. Dimensions for stainless steel converter housing see page 40.
38
D184S075U02
4.2.8
Adaptor for variable process connections DN3 100 ( 1/10 ... 4")
Rd-Gew.
Da
Di
1
a
Da
Di
3
Fig. 35 (Dimensions in mm) 1 2 Weld stubs Food Ind. Fittings per DIN 11851 ISO 2037 DN 3 - 10 15 20 25 32 40 50 65 80 100 Di 10 15,2 19,3 22,6 31,3 35,6 48,6 60,3 72,9 97,6 Da 12 17,2 21,3 25 33,7 38 51 63,5 76,1 101,6 Di 10 16 20 26 32 38 50 66 81 100 DIN 11850 Da 13 19 23 29 34 41 54 70 85 104 Serie s 2 2 2 2 1 2 3 2 2 2 SMS Di 22,6 35,6 48,6 60,3 72,9 100 Da 25 38 51 63,5 76,1 104 3 4 Tri-Clamp External threads
G00072
Weld stubs DIN 2463 Di 10,3 18,1 23,7 25 32 36,8 49 66 81 100 Da 13,5 21,3 26,9 28 35 40 52 70 85 104 Di 10,3 18,1 23,7 23,7 30,5 39 47,8 66 72,9 97,6
ISO1127 L Da 13,5 21,3 26,9 26,9 33,7 42,2 51 70 76,1 101,6 Series 1 1 1 1 1 1 2 2 1 2 127 127 132 149 166 171 173 165 169 199 Weight /kg 0,4 0,4 0,7 0,7 1 1 1 1,4 2 3
DN 3 - 10 15 20 25 32 40 50 65 80 100
Food Ind. Fitting DIN 11851 Weight /kg Rd.Thd. L 28 x 1/8" 169 0,5 34 x 1/8" 169 0,5 44 x 1/6" 180 0,9 52 x 1/6" 207 0,9 58 x 1/6" 230 1,4 65 x 1/6" 237 1,4 78 x 1/6" 243 1,4 96 x 1/6" 245 2,2 110 x 1/4" 259 3,2 130 x 1/4" 307 4,4
Tri-Clamp Di 10 16 20 26 32 38 50 66 81 100 DIN 32676 Serie s Da L 34 3 163 34 3 163 34 3 168 50,5 3 192 50,5 3 209 50,5 3 214 64 3 216 91 1 221 106 1 225 109 1 225 ASME BPE Gew./kg 0,5 0,5 0,7 0,8 1,5 1,4 1,2 1,6 2,4 3,1 TriClamp 1/2" 3/4" 1" 1" 1 1/2" 2" 2 1/2" 3" 4" Di 9,4 15,7 22,1 22,1 34,8 47,5 60,2 72,9 97,4 Da 25,0 25,0 50,4 50,4 50,4 63,9 77,4 90,9 118,9 L 143 143 143 143 277 277 277 337 337 Weight /kg 0,5 0,5 0,7 1,2 1,8 1,8 2,0 3,6 4,1
DN 3-10 15 20 25
External threads ISO 228 a L Weight /kg 18 139 0,4 18 139 0,4 25 164 0,8 25 179 0,8
39
D184S075U02
4.2.9
99
G00071
40
D184S075U02
Variant digit No. 1-5 6 7 8 9 10 11 12 13 14 15 16 Electromagnetic Flowmeter compact design Catalog No. DE23FXE4000-DE23 (COPA-XE) Process connection 1) W Wafer type V Without adapter (for replacement only) Weld stubs ISO 1127 J (only DN 10...DN 100) P Weld stubs ISO 2037 Weld stubs DIN 2463 Q (DN 25, DN40...DN 100) R Weld stubs DIN 11850 Weld stubs SMS X Pipe connection DIN 11851 S DIN 32676 T Tri-Clamp DIN 2501 / ANSI F Welded flange (only DN 3...DN 25) E Male thread ISO 228 ASME BPE (DN 3...DN 100) K Tri-Clamp others Z Liner material Meter size PFA DN 3 1/10 in P 0 3 PFA DN 4 5/32 in P 0 4 PFA DN 6 1/4 in P 0 6 PFA DN 8 5/16 in P 0 8 PFA DN 10 3/8 in P 1 0 PFA DN 15 1/2 in P 1 5 PFA DN 20 3/4 in P 2 0 PFA DN 25 1 in P 2 5 PFA DN 32 1 1/4 in P 3 2 PFA DN 40 1 1/2 in P 4 0 PFA DN 50 2 in P 5 0 PFA DN 65 2 1/2 in P 6 5 PFA DN 80 3 in P 8 0 PFA DN 100 4 in P 1 H 2) Grounding electrodes Measuring electrodes material Hastelloy C-4 (2.4610) without H Hastelloy B-3 (2.4600) without B without S SST (1.4571) Titanium without M Tantalum without T without F SST (1.4539) Platinum-Iridium without P Hastelloy C-4 (2.4610) with O with N Hastelloy B-3 (2.4600) SST (1.4571) with E Titanium with I Tantalum with Q with R SST (1.4539) Platinum-Iridium with G 3) Pressure rating PN 10 Tri-Clamp (DN 65...100), male thread, pipe connection C welded stub ends (DN 65, 100) PN 16 Wafer type (DN 65... 100), Tri-Clamp (DN 3...50), pipe connection, D 4) welded stub ends (DN 50, 80), welded flange (DN 100) F PN 40 Wafer type (DN 3...50), pipe connection, welded stub ends (DN 3...40), welded flange (DN 3...80) ASME CL 150 Wafer type DN 3...100, welded flange DN 3...100 P Q ASME CL 300 Wafer type DN 3...50, welded flange DN 3...100 Continued on next page 1) Accessories see table H 2) Grounding electrodes >= DN 3 3) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K 4) DN 65/PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40
41
D184S075U02
Accessories without A with fastening element (<= DN 40) not with welded flange 6) C not with welded flange 6) C with fastening element (> DN 40) with welded flange only 5) B Protection flange SST 1.4571 with welded flange only 5) C Grounding ring SST 1.4571 Temperature range Standard design <= 130 C (266 F) S Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B PMO approval Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 100 1 in4 in) (DN 25...DN 100 1 in4 in) Custody transfer, fluids except water Type of protection IP 67 Power supply 100...230 V AC 16.8...26.4 V AC / 16.8...31.2 V DC Display illuminated Input / output options Current output/ +Pulse output active/ +Contact input/ +Contact output Current output/ +Pulse output active/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact input/ +Contact output Current output/ +Pulse output passive/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact output/ +RS 485 Pulse output passive/ +Contact output/ +PROFIBUS DP PROFIBUS PA 3.0 FOUNDATION Fieldbus PROFIBUS PA 3.0 with M12 plug Material of converter housing / cable entry Aluminium M20 x 1.5 SST M20 x 1.5 Aluminium 1/2 in NPT Aluminium PF 1/2 in 5) Protection flange on both and grounding ring fastened on one side to flange 6) Not with 3A Certificate
Electromagnetic Flowmeter FXE4000-DE23 (COPA-XE) Name plate German English French Design level Gasket material EPDM without Silicone Electrode design Standard Conical head, SST 1.4539
1-5
16 17 18 19 20 21 22 23 24 25 26
compact design
Catalog No.
DE23G E F
(specified by ABB) (with FDA certificate) (wafer type and welded flange only) (with FDA certificate) (>= DN 10)
* E A S 7) 1 2
7) For application e.g. with high fat contents Note to the 3A conformity Order this option in clear text. Mounting parts are void then. Please observe the special installation conditions - see Operating Instruction
42
D184S075U02
Variant digit No. 1-5 6 Electromagnetic Flowmeter Catalog No. DE21FXE4000-DE21 (MAG-XE) remote design Process connection 1) W Wafer type V Without adapter (for replacement only) Weld stubs ISO 1127 J (only DN 10...DN 100) P Weld stubs ISO 2037 Weld stubs DIN 2463 Q Weld stubs DIN 11850 R (DN 25, DN40...DN 100) X Weld stubs SMS DIN 11851 S Pipe connection Tri-Clamp DIN 32676 T DIN 2501 / ASME F Welded flange (only DN 3...DN 25) E Male thread ISO 228 ASME BPE (DN 3...DN 100) K Tri-Clamp others Z Liner material Meter size DN 3 1/10 in PFA PFA DN 4 5/32 in PFA DN 6 1/4 in PFA DN 8 5/16 in PFA DN 10 3/8 in PFA DN 15 1/2 in PFA DN 20 3/4 in PFA DN 25 1 in PFA DN 32 1 1/4 in PFA DN 40 1 1/2 in PFA DN 50 2 in PFA DN 65 2 1/2 in PFA DN 80 3 in PFA DN 100 4 in Grounding electrodes Measuring electrodes material Hastelloy C-4 (2.4610) without Hastelloy B-3 (2.4600) without without SST (1.4571) Titanium without Tantalum without without SST (1.4539) Platinum-Iridium without with Hastelloy C-4 (2.4610) with Hastelloy B-3 (2.4600) with SST (1.4571) Titanium with Tantalum with with SST (1.4539) Platinum-Iridium with Pressure rating PN 10 Tri-Clamp (DN 65...100), male thread, pipe connection, welded stub ends (DN 65, 100) PN 16 Wafer type (DN 65...100), Tri-Clamp (DN 3...50), pipe connection, welded stub ends (DN 50, 80), welded flange (DN 100) PN 40 Wafer type (DN 3...50), pipe connection, welded stub ends (DN 3...40), welded flange (DN 3...80) ASME CL 150 Wafer type DN 3...100, welded flange DN 3...100 ASME CL 300 Wafer type DN 3...50, welded flange DN 3...100
10 11 12 13 14 15
P P P P P P P P P P P P P P
0 0 0 0 1 1 2 2 3 4 5 6 8 1 2)
3 4 6 8 0 5 0 5 2 0 0 5 0 H H B S M T F P O N E I Q R G 3) C D 4) F P Q
Continued on next page 1) Accessories see table H 2) Grounding electrodes >= DN 3 3) Connection dimensions for flanges acc. to DIN 2501/ EN 1092-1 or ASME B16.5 or JIS B2210-10K 4) DN 65/ PN 16 with connection dimensions acc. EN 1092-1: Please order PN 40
43
D184S075U02
Variant digit No. 1-5 Electromagnetic Flowmeter Catalog No. DE21FXE4000-DE21 (MAG-XE) remote design Material of process connection without wafer type only + spare primary SST 1.4571 welded flange only SST 1.4404 others Accessories without with fastening element (<= DN 40) not with welded flange 6) with fastening element (> DN 40) not with welded flange 6) with welded flange only 5) Protection flange SST 1.4571 with welded flange only 5) Grounding ring SST 1.4571 Temperature range Standard design <= 130 C (266 F) Certificates without Material certificate per EN 10204 3.1B + pressure test per AD 2000 Pressure test per AD 2000 Inspection certificate per EN 10204 3.1B PMO approval Calibration certificates without Custody transfer, cold water / waste water (DN 25...DN 100 1 in4 in) Custody transfer, fluids except water (DN 25...DN 100 1 in4 in) Type of protection IP 67 IP 67 Gewinde fr Kabelverschraubung NPT 1/2 in IP 68 IP 68 Cabel connected and potted Connection box Name plate German English French (specified by ABB) Design level Gasket material EPDM (with FDA certificate) without (wafer type and welded flange only) (with FDA certificate) Silicone Electrode design Standard Conical head, SST 1.4539 (>= DN 10)
12 13 14 15 16 17 18 19 20 21
0 3 4 9 A C C B C S A D G F P A B C 2 4 7 8 G E F * E A S 7) 1 2
5) Protection flange on both and grounding ring fastened on one side to flange 6) Not with 3A Certificate 7) For application e.g. with high fat contents Related Converter FXE4000-E4 Note to the 3A conformity Order this option in clear text. Mounting parts are void then. Please observe the special installation conditions - see Operating Instruction
44
D184S075U02
5
5.1
Transmitter
Specifications:
Continuously adjustable between 0.5 and 10 m/s 0.5 % of rate 0.25 % of rate (option) 0.15 % of rate 5 S/cm (20 S/cm for demineralized water) For a step change 0-99 % (corresponds to 5 ) 1 s for 6 1/2 Hz exciter frequency High voltage AC: 100 - 230 V (- 15/+10 %) Low voltage AC: 16.8 -26.4 V Low voltage DC: 16.8 - 31.2 V, ripple: < 5 % 47 - 63 Hz 6 Hz, 7 Hz 12 Hz, 15 Hz, 25 Hz, 30 Hz (50/60 Hz supply power) 14 VA for AC supply power (flowmeter primary incl. converter) For AC supply power 6 W for DC supply power DC (flowmeter primary incl. converter) -20 C to +60 C Spring loaded screwless terminals Flow direction is indicated by direction arrows in the display and signaled over the optocoupler output (ext. contact output).
5.2
Housing Variants
COPA XE
Compact design with converter housing made of cast light metal, painted, paint coat 60 m thick, rear section RAL 7012 dark gray, front section (cover) RAL 9002 light gray Option Converter housing made of stainless steel [304]
MAG-XE
Field mount housing made of cast light metal, painted, paint coat 60 m thick, rear section RAL 7012 dark gray, front section (cover) RAL 9002 light gray Panel installation housing Housing for rail mounting
Supply power
Weight
COPA-XE: see Data Sheet MAG-XE (converter): Field mount housing: 4.5 kg Rail mount housing: 1.2 kg Panel installation housing 1.2 kg
45
5.3
In- / Outputs
Y
I max
-100 %
0%
X
100 %
I min -100 % 0%
X 100 %
Y 20 10
-100 % 0%
Y 20 10 X 100 % 4
-100 % 0% (4-12-20 mA)
Contact input
X 100 % G00091
(0-10-20 mA)
Fig. 37 Y = Current [mA] X = Flow direction/flowrate Scaled Pulse Output (Terminals V8, V9 or Ux, V8) Scaled pulse output max. 5 kHz, pulse factor which can be set between 0.001 and 1000 is a multiplier for the value displayed (1 3 pulse/m x 1000). The pulse width can be set between 0.1 ms and 2000 ms. A change between an active or passive configuration can be made using jumpers. Design Function Operating voltage Operating current and frequency Optocoupler Passive E9, C9 UCEL = 0 ... 2 V UCEH = 16 ... 30 V ICEH = 0 ... 0.2 mA ICEL = 5 ... 220 mA fmax 5 kHz Active 9, 10 U = 16 V ... 30 V I = 20 ... 150 mA fmax = 4 Hz Pulse width: 50 ms Pulse: 16 V 25 ms On/off ratio: 1:4 (Ton : Toff) I = 2 ... 20 mA fmax = 5 kHz U = 16 ... 30 V
The following functions can be assigned via the software: Ext. Zero Return When the pipeline empties all the outputs can be turned off. Ext. Totalizer Reset The internal totalizer values can be reset via an external contact. Optocoupler, Terminals X1, G2 U = 16 ... 30 V, Ri 2 k
Ext. Totalizer Stop The flow integration can be stopped independently of the instantaneous flowrate.
46
5.4 5.4.1
5.4.3
Fig. 38 HART-Protocol Configuration
Transmission
Max. Signalamplitude Current output min. 250 , max. < 600 load: Cable Cable AWG 24 twisted Max. cable length 1500 m For more detailed information see the separate Data Link Description
Directly on the device Software SMART VISION (+HART DTM) FSK Modulation on the current output 4-20 mA per Bell 202 Standard 1.2 mApp
Transmission signal
Ethernet
FOUNDATION Fieldbus H1
100 1 F
HSE-Bus
5.4.2
PROFIBUS PA Protocol
FF+ FFFF+ FF-
The data link conforms to Profile 3.0 (Standard PROFIBUS, EN 50170, DIN 19245 [PRO91]). PROFIBUS PA Ident-No.: Alternative Standard-IdentNo. Configuration 0691 hex. 9700 or 9740 Directly on the device Software SMART VISION (+PROFIBUS PA DTM) per IEC 61158-2 Shielded, twisted (Type A or B cables are preferred as defined in IEC 61158-2)
FF+ FFG00112
B = Linking Device (incl. bus feed and terminator) Fig. 40 Example for FOUNDATION Fieldbus connection
Bus topology
Tree and/or linear structure Bus termination: Passive at both ends of the main bus cable (RCcomponent R = 100 , C = 1 F)
PROFIBUS DP
PROFIBUS PA
H2-Bus
100 1 F
PA+ PA-
PA+ PA-
PA+ PAG00111
A = Segment coupler (incl. bus feed and terminator) Fig. 39 Example for PROFIBUS PA connection
47
D184S075U02
5.4.5
PROFIBUS DP Protocol
System Connection
Required are: DD-File (Device Description), which contains the device description. CFF-File (Common File Format), required to engineer the segment. The engineering can be accomplished on- or offline. Both files as well as the interface description are located on the supplied CD (part no.: D699D002U01). If required, it can be ordered from ABB at no cost. The files required for operation can also be downloaded from the website http://www. fieldbus.org. For more detailed information see the separate Data Link Description Part No. D184B093U17.
B A
+VD B A GND +5 V
B A
32
G00110
Fig. 42 Directly on the device Software SMART VISION Transmission RS485 data link Transmission speed 9.6 1500 Kbit/s Protocol per EN 50170 Ident-No. 6666 HEX Cyclic (Output variables, see separate data link description for COPA/MAG-XE) Cable Shielded, twisted pair Max. cable length 1200 m (cable type A) Baudrate 9.6 1500 Kbit/s Characteristic resistance 135 165 Distributed capacitance < 30 pF/m Loop resistance 110 /km The max. tap line length is a function of the baudrate and the number of instruments. Send and receive signals on the same terminal. For more detailed information see the separate Data Link Description Terminal +VD A B GND Function VP RxD / TxD-N RxD / TxD-P C DGND Reference Supply voltage +5V Receive/send-data-N Receive/send-data-P Data reference potential M5V Configuration
5.4.4
ASCII-Protocol
G00096
Fig. 41 ASCII-Protocol Transmission V pp = 5 V. Input impedance: Cable Cable Max. cable length
1200 m Baudrate 1200-9600 Terminals A and B Max. 32 Instruments on a single bus For more detailed information see the separate Data Link Description
48
D184S075U02
5.4.6 5.4.6.1
b) 10
9 2+ N 1+ L
a) C9 E9
V9 V8 P7 G2 X1
PE
G00061
Fig. 43 1 a) Scaled pulse output, passive: Pulse width adjustable from 0.1 to 2000 ms, terminals V8, V9, function E9, C9 Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA b) Scaled pulse output, active: Pulse width adjustable from 0.1 to 2000 ms, terminals V8, V9, function 9, 10 20 mA < I 150 mA, fmax 4 Hz, pulse width 50 ms, pulse T16V 25 ms; on/off ratio: 1:4 (Ton : Toff), fmax 5 kHz, 2 mA I 20 mA; 16 V U 30 V 2 Contact output: Function selectable via software to system monitor, empty pipe, max.-min.-alarm or V/R contact output*, terminals G2, P7 Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V; 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA 3 Contact input: Function selectable via software as external zero return, external totalizer reset, external totalizer stop, terminals G2, X1 Optocoupler specifications: 16 V U 30 V, Ri = 2 k 4 Current output: Adjustable, terminals +/-, Current 600 for 0/4 ... 20 mA, Current 1200 for 0/2 ... 10 mA, Current 2400 for 0 ... 5 mA, Option: HART-Protocol 5 Supply Power: See name plate 6 Functional ground *) The default factory setting is the forward direction signal.
49
D184S075U02
5.4.6.2
FXE4000 (COPA-XE), digital communication Valid for PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, ASCII
1 2 3 4
Ux Ux V8 V8 P7
P7 +VD
FF+ FF-
PE
G00064
Fig. 44 1 PROFIBUS PA: Terminals PA+, PA-: Connection for PROFIBUS PA according to IEC 61158-2 (Profile 3.0), U = 9 - 32 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE) 2 ASCII-Protocol (RS485): Terminals Ux, V8: Scaled pulse output, passive (Optocoupler), pulse width adjustable between 0.1 ms to 2000 ms, Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA Terminals Ux, P7: Contact output, function selectable via software e.g. to system monitor, empty pipe, max. min. alarm or V/R contact output Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA Terminals A, B: Serial data link RS485 for communication using ASCII-Protocol Terminals +, -: Current output, terminals: +/-, current 600 for 0/4 to 20 mA 3 PROFIBUS DP: Like design 2 but terminals +VD, A, B, GND connection for PROFIBUS DP according to EN 50170 4 FOUNDATION Fieldbus: Terminals FF+, FF-: Connection for FOUNDATION Fieldbus (H1) according to IEC 611582, U = 9 ... 32 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE) 5 Supply Power: See name plate 6 Functional ground
50
D184S075U02
5.4.6.3
G00065
Fig. 45 1 a) Scaled pulse output, passive: Pulse width adjustable from 0.1 to 2000 ms, terminals V8, V9, function E9, C9 Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA b) Scaled pulse output, active: Pulse width adjustable from 0.1 to 2000 ms, terminals V8, V9, function 9, 10 20 mA < I 150 mA, fmax 4 Hz, pulse width 50 ms, pulse T16V 25 ms; on/off ratio: 1:4 (Ton : Toff), fmax 5 kHz, 2 mA I 20 mA; 16 V U 30 V 2 Contact output: Function selectable via software to system monitor, empty pipe, max.-min.-alarm or V/R contact output*, terminals G2, P7 Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA 3 Contact input: Function selectable via software as external zero return, external totalizer reset, external totalizer stop, terminals G2, X1 Optocoupler specifications: 16 V U 30 V, Ri = 2 k 4 Current output: Adjustable, terminals +/-, Current 600 for 0/4 ... 20 mA, Current 1200 for 0/2 ... 10 mA, Current 2400 for 0 ... 5 mA, Option: HART-Protocol 5 Supply Power: See name plate 6 Functional ground 7 White 8 Blue A Converter 9 Red 10 Yellow B Flowmeter primary 11 Steel shielding
51
D184S075U02
5.4.6.4
FXE4000 (MAG-XE), digital communication Valid for PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, ASCII
1 2 3 4
PA+ PAUx Ux V8 V8 P7 A B A + B GND 2N 1+ L
P7 +VD
FF+ FF-
5 PE
M1 M2 2S
1S
6 7 8 9 10 11
6
M1 M2 2 1 3 SE
G00066
Fig. 46 1 PROFIBUS PA: Terminals PA+, PA-: Connection for PROFIBUS PA according to IEC 61158-2 (Profile 3.0), U = 9 - 32 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE) 2 ASCII-Protocol (RS485): Terminals Ux, V8: Scaled pulse output, passive (optocoupler), Pulse width adjustable between 0.1 ms to 2000 ms, Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA Terminals Ux, P7: Contact output, function selectable via software e.g. to system monitor, empty pipe, max. min. alarm or V/R contact output Optocoupler specifications: fmax 5 kHz, 0 V UCEL 2 V, 16 V UCEH 30 V, 0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA Terminals A, B: Serial data link RS485 for communication using ASCII-Protocol Terminals +, -: Current output, terminals: +/-, current 600 for 0/4 to 20 mA 3 PROFIBUS DP: Like design 2 but terminals +VD, A, B, GND connection for PROFIBUS DP according to EN 50170 4 FOUNDATION Fieldbus: Terminals FF+, FF-: Connection for FOUNDATION Fieldbus (H1) according to IEC 611582, U = 9 ... 32 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE) 5 Supply Power: See name plate 6 Functional ground 7 White 8 Blue A Converter 9 Red 10 Yellow B Flowmeter primary 11 Steel shielding
52
D184S075U02
5.4.6.5
Interconnection examples for the peripherals with analog communication (incl. HART)
Current Output
I = internal, E = external 0/4 - 20 mA 0/2 -10 mA 0 - 5 mA Load 600 Load 1200 Load 2400
G00101
E
V9 (10) V8 (9)
G00102
24V+
Imax = 220 mA
24V+
* RB UCE
ICE
Fig. 48 Contact Input for External Zero Return (Function assigned in software)
I
X1 G2
Ri = 2 k
E
24V+ 0V
24V+ 0V
G00103
Contact setting: Output is turned off when contact is closed. Fig. 49 Contact Output for System Monitor, Max.Min.-Alarm, Empty Pipe or Forward/Reverse Direction Signal (Function assigned in software)
I
P7 G2
Pulse Output passive Optocoupler, Separate Forward and Reverse Pulses on Contact Output
I E
E
+U
R B*
Imax = 220 mA
V9 (C9) V8 (E9)
* RB UCE
ICE
G2 P7
24V+
G00104
Fig. 50
53
D184S075U02
5.4.6.6
Interconnection examples for the peripherals with digital communication Current Output (only for ASCII-Communication) 0/4 - 20 mA load: max. 600 I = internal E = external Fig. 51 Pulse Output and Contact Output (only available for PROFIBUS DP or ASCIIProtocol)
I
Ux
Imax R
G00101
Connection example for separate pulses for forward and reverse direction using the contact output
I E
Ux
24V+
Imax= 220 mA
24V+
1 2
V8
V8
Imax
P7
Imax= 220 mA
P7
Imax= 220 mA
G00105
Fig. 52 Contact Output Ux / P7 (for System Monitor, Max.-Min.-Alarm, Empty Pipe or Forward/Reverse Direction Signal ,Function assigned in software) Pulse Output Ux/V8 (Optocoupler)
Data Link RS485 (ASCII Protocol) 1 2 Forward Reverse
I = internal
E = external
Two wire data link, half-duplex, max. cable length: 1200 m, max. 32 instruments in parallel on bus cable, twisted pair cable. I = internal
E = external
A B
G00108
Fig. 53
54
D184S075U02
The resistors R1, R2, R3 are bus termination resistors. They are to be installed when the instrument is connected at an end of the bus cable. R1 = 390 ; R2 = 220 ; R3 = 390
1 2 PROFIBUS DP Cable (e.g. CDN110: 636469890140), max. Length 20 cm Plug for T-Box (e.g. Manuf. Weidmller 1784790000)
GND
A B
+VD
R1 R2 R3
P7 V8 Ux
G00106
Fig. 54
PROFIBUS PA / FOUNDATION Fieldbus
The resistor R and the capacitor C form the bus termination. They are to be installed when the instrument is connected to the end of the bus cable. R = 100 ; C = 1 F
1 2 PROFIBUS PA FOUNDATION Fieldbus
PAPA+
1
R C
FF+ FF2
R C
G00107
I = internal E = external
Fig. 55
PAL N
PAPA+
3 2
PA+
nc
G00109
Fig. 56 As an option, the bus cable can be connected using a M12 plug instead of PG connectors (see Ordering Information for the instrument). The instrument is then shipped completely wired. Suitable sockets (Type EPG300) together with additional accessories may be found in the List Sheet 10/63.6.44 DE.
55
D184S075U02
5.5 5.5.1
Converter scale drawing FXE 4000-E4 (MAG-XE) Converter housing and mounting arrangements
198 10 139.7 167
7
265
14.5
249
66 132
38 83.5
M20 x 1,5
min. 62
min.175
4
G00073
1 Field mount housing with window 2 Cable connector M20 x 1.5 3 Mounting holes for pipe mounting set for a 2 pipe installation; mounting set upon request (order no. 612B091U07) 4 Protection class IP 67
56
D184S075U02
5.5.2
ABB
96 x 96
MAG - XE
DATASTEP C/CE
ENTER
155
11,5
M2M1
+ X1 G2 P7 62 V8 V9
98,5 x 98,5
1S 1 2 2S 3
32
N PE L
G00075
mm)
5.5.3
G00076
Fig. 59 (Dimensions in mm) 1 2 3 Supply power connection plug Connection plug in- / outputs Station ground 4 5 Signal/ activation cable connection plug Min. distance to remove plug
57
D184S075U02
5.5.4
Ordering Information
Variant digit No. 1-3 4 5 6 External Converter (MAG-XE) Catalog No. E4FXE4000-E4 Housing Field housing, (Thread for screw-type conduit fitting M20 x 1.5) Q rectangular (Thread for screw-type conduit fitting NPT 1/2 in R (Thread for screw-type conduit fitting PF 1/2 in) S Housing for rail mounting design O Panel 96 mm x 96 mm with front door and look T X without housing (only plug-in, e.g. for replacement) Power supply 100...230 V AC N 16.8...26.4 V AC / 16.8...31.2 V DC K Display magnetic stick operation and display illuminated D Input / output options Current output/ +Pulse output active/ +Contact input/ +Contact output Current output/ +Pulse output active/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact input/ +Contact output Current output/ +Pulse output passive/ +Contact input/ +Contact output/ +HART protocol Current output/ +Pulse output passive/ +Contact output/ +RS 485 Pulse output passive/ +Contact output/ +PROFIBUS DP PROFIBUS PA 3.0 FOUNDATION Fieldbus PROFIBUS PA 3.0 with M12 plug For Primary Non-Ex type Application Standard Certificates without Custody transfer, cold water / waste water Custody transfer, fluids except water Name plate German English French (specified by ABB) Design level (specified by ABB) Software level
10 11 12 13 14
0 0 0 0 0 0 1 1 1
1 2 3 4 5 6 4 5 6 0 0 0 1 2 G E F * *
Accessories
Shielded signal / excitation cable Accessories for 2 in pipe mounting (10 m included in base price) Catalog No. D173D025U01 612B091U07 price per meter
58
D184S075U02
Wafer accessories
FX / FSM Material: SST Meter size DN 3...DN 10 DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 Pressure rating PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 16 PN 25...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 40 ASME CL 150 ASME CL 300 PN 10...PN 16 PN 25...PN 40 ASME CL 150 Catalog No. D614L265U03 D614L265U03 D614L265U04 D614L265U03 D614L266U05 D614L266U06 D614L267U04 D614L267U05 D614L267U06 D614L268U04 D614L268U05 D614L268U06 D614L269U04 D614L269U05 D614L269U06 D614L270U04 D614L270U05 D614L270U06 D614L296U04 D614L296U05 D614L296U06 D614L297U08 D614L297U09 D614L297U10 D614L297U11 D614L298U08 D614L298U09 D614L298U10 D614L299U07 D614L299U08 D614L299U09
DN 80 DN 100
These fitting piece is an aid for receivers with process connection weld stubs It makes possible to weld these weld stub coplanar into the pipe
59
D184S075U02
Variant digit No. Flowmeter Primary Simulator Catalog No. FXC4000 1) Flow signal setting without (only adapter) 3-position digitswitch with 1000 steps others Power supply without (only adapter) with Schuko plug 110 V...240 V 50 / 60 Hz 24 V...48 V AC / DC with 4mm plug with US plug 110 V...240 V 50 / 60 Hz others Accessories without FXE4000-E4, FXM2000-XM2, FXF2000-DF23 Adapter for converter type Adapter for simulator 55XC2000 Adapter plate for converter FSM4000-S4 others (specified by ABB) Design level Name plate German English French others
55XC40 1 9 2) 0 1 2 3 9 0 1 2 5 9 * 1 2 3 9
3)
1) Also older product models 50XM1000, 50XH1000, 50XO1000, 50SM1000 can be tested with test simulator type FXC4000 2) Power supply is for converter supplying 3) The adapter listed above for converter types FXE4000-E4, FXM2000-XM2, FXF2000-DF23 can also be used for existing simulator type 55XC2000. If two adapters are required, then the catalog number for each adapter type is to be used.
A
60
ABB has Sales & Customer Support expertise in over 100 countries worldwide. www.abb.com/flow
The Companys policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (07.2006) ABB 2006
ABB Limited Oldends Lane, Stonehouse Gloucestershire, GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671
ABB Inc. 125 E. County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183
ABB Automation Products GmbH Dransfelder Str. 2 37079 Goettingen Germany Tel: +49 551 905-534 Fax: +49 551 905-555 CCC-support.deapr@de.abb.com
D184S075U02