Você está na página 1de 24

Albatros2 Controller, HMI and accessories Range Description

CE1S2359 en 21.01.2013

Building Technologies
Control Products & Systems

Albatros2 product range

2 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Albatros2 product range

Albatros2 product range


Albatros2, or:
Wired

Intelligent control functions for the highest level of energy efficiency. Complete product range for all tasks in the heating segment. Scalable, modular concept for simple to complex plants. Modern communications and visualization. Auxiliary devices featuring RF or wired communications.

Wireless

3 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

Controller

Heat pump Two-stage heat pumps Boiler 2-stage burner/modulating burner (3-point) Modulating fan (PWM output) Combustion optimization Sitherm Pro (LMS15 only) Supplementary source Solar integration Buffer, swimming pool Modulating solar pump Solid fuel boiler integration Cascade Heating circuit control Cooling circuit control DHW control Instantaneous DHW heater (down stream of storage tank) Buffer storage tank LPB
* with LPB-Clip-in OCI345.06/101

4 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 HEATPUMPCONTROLLER, PCB Inputs, number Mains Sensor Digital-/0..10V 4 EX 4 BX Outputs, number Relay Digital 0..10V/PWM 5/12V act. sensors Connection to Operator units Extension modules I/O modules Service tool Radio module BSB devices LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples Designation AVS37.x9x (HMI) AVSx5.39x, AVS75.370 (max. 3 module) AVS55.19x (max. 1 module) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx e.g. LPB controller AGP5S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CE1U2355en_041, CE1U2355en_041a 5 QX

RVS21.826

3 fixed at X75 1 ZX 3 UX 1 GX With/on Ribbon cable Ribbon cable Ribbon cable "BSB" slot "X60" slot CL-, CL+ to "X86" LPB clip-in OCI345.06/101 Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 AVS82.496/109 Cable included in delivery Cable included in delivery

4 (2 fixed at X75, 2 HX) Triac

230 V ~, 50/60 Hz IP 00 (no housing) class 3K5, -20...50 (non-condensing) 185 x 115 x 42 mm 193 g 28 pieces

Selection of 17 preset diagrams of complete plants. Compilation of partial diagrams as per CE1P2359_10. EX1 EX2 QX3 QX5 ZX6 BX1 BX2 BX3 BX4 Low-pressure switch E9 High-pressure switch E10 Compressor stage 1 K1 Condenser pump Q9 Source pump Q8/Fan K19 Source inlet B91 HP flow sensor B21 HP return sensor B71 Outside sensor B9

Plant diagram 1: Brine-to-water heat pump with pump heating circuit.

5 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 HEATPUMP CONTROLLER Inputs, number Mains Sensor Digital-/0..10V Connection to Operator units Extension modules Service tool Radio module BSB devices Service tool LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 10 EX 11 BX 2 HX Designation AVS37.x9x (HMI) AVSx5.39x (max. 3 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI700.1 (including ACS790) e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging Contents Relay Triac

RVS61.843 (as of series C) Outputs, number 12 QX 1 ZX

0..10V/PWM 2 UX With/on Ribbon cable Ribbon cable "BSB" slot "X60" slot Terminals CL-, CL+ "LPB" slot Terminals MB, DB Cable included in delivery Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery

230 V ~, 50/60 Hz IP 00 class 3K5, -20...50 (non-condensing) 281 x 121 x 70 mm 650 g 1 piece or 20 piece

CE1U2355en_051, CE1U2355en_051a Selection of 24 preset diagrams of complete plants. Compilation of partial diagrams as per CE1P2359_10.

Plant diagram 5: Brine-to-water heat pump with buffer storage tank, DHW storage tank with charging pump Q3, and mixing or pump heating circuit. BX1 BX2 BX7 BX8 BX9 BX10 BX11 BX12 BX13 Buffer storage tank sensor B4 Buffer storage tank sensor B41 Hot-gas sensor B81 DHW sensor B3 Outside sensor B9 HP flow sensor B21 B1 HP return sensor B71 Source inlet sensor B91 etc.

6 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 BOILER MANAGEMENT UNIT, PCB Inputs, number Mains Sensor Digital/0..10V/Frequency Connection to Operator units Extension modules Service tool Radio module BSB devices Lab tool Parameter stick LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 1 fix (STB) 7 (3 fix, 4 BX) 6 HX Outputs, number Relay Stepping motor PWM

LMS14/15 3 QX 1 QX 1 PX

Designation AVS37.x9x (HMI) AVSx5.39x, AGU2.55x (max. 3 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI430 (including ACS420) AGU2.56x e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CC1U7471en

With/on Ribbon cable Ribbon cable "BSB,LPB" slot "X60" slot Terminals CL-, CL+ "X13" slot "X12" slot LPB clip-in

Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 AGU2.110A109 Cable included in delivery

Cable included in delivery Docking station for programming OCI432 OCI345.06/101

230 V ~, 50 Hz; 115 V ~, 60 Hz IP 00 Class 3K5, 0...60 (non-condensing) 203 x 150 x 30 mm 254 g 24 pieces

Compilation of partial diagrams as per CE1P2359_10. Partial diagrams OeG12 and TWWDl6 and Rh1 OeG12 TWWDl6 Rh1 B2, Q1 B38, Q34 (+ 1 configuration) 1 configuration

7 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 BOILER CONTROLLER Inputs, number Mains Sensor Digital-/0..10V Connection to Operator units Extension modules Service tool Radio module BSB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 2 fixed 6 (4 fix, 2 BX) 1 HX Designation AVS37.x9x (HMI) AVSx5.39x (max. 3 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CE1U2357en_01, CE1U2357en_01a Compilation of partial diagrams as per CE1P2359_10. Partial diagrams OeG3 and TWWSp13 and Rh1 With/on Ribbon cable Ribbon cable "BSB" slot X60 slot Outputs, number Mains Relay 1 fixed

RVS13.143

6 (5 fix, 1 QX)

Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery Cable included in delivery

Terminals CL-, CL+

230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 181 x 121 x 52 mm 566 g 20 pieces

OeG3 TWWSp13 Rh1

B2, Q1 (+ 1 configuration) B3, Q3 (+ 2 configurations) 1 configuration

8 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 BOILER CONTROLLER Inputs, number Mains Sensor Digital-/0..10V Connection to Operator units Extension modules Service tool Radio module BSB devices Service tool LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 4 (3 fix, 1 EX) 6 (3 fix, 3 BX) 2 HX Designation AVS37.x9x (HMI) AVSx5.39x (max. 3 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI700.1 (including ACS790) e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CE1U2354en_02, CE1U2354en_02a Compilation of partial diagrams as per CE1P2359_10. Partial diagrams OeG2 and TWWSp4 and Rh3 Outputs, number Mains Relay 5/12V act. sensors 1 fixed

RVS43.345

5 (1 fix, 4 QX) 1 GX With/on Ribbon cable Ribbon cable "BSB" slot X60 slot Terminals CL-, CL+ "LPB" slot Terminals MB, DB Cable included in delivery Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery Cable included in delivery

230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 181 x 121 x 52 mm 400 g 20 pieces

OeG2 TWWSp4 Rh3

B2 (+ 1 configuration) B3, Q3 (+ 2 configurations) 2 configurations

9 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 BOILER CONTROLLER Inputs, number Mains Sensor Digital-/0..10V Connection to Operator units Extension modules Service tool Radio module BSB devices Service tool LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 3 (2 fix, 1 EX) 9 (5 fix, 4 BX) 2 HX Designation AVS37.x9x (HMI) AVSx5.39x (max. 2 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI700.1 (including ACS790) e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging Contents CE1U2354en_01, CE1U2354en_01a Compilation of partial diagrams as per CE1P2359_10. Outputs, number Mains Relay, QX 0...10V 1 fixed

RVS63.283

12 (8 fix, 4 QX) 1 UX With/on Ribbon cable Ribbon cable "BSB" slot X60 slot Terminals CL-, CL+ "LPB" slot Terminals MB, DB Cable included in delivery Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery Cable included in delivery

230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 281 x 121 x 52 mm 648 g 1 piece or 20 piece

Partial diagrams OeG2 and TWWSp4 and HK1: Rh3 and HK2: Rh3 OeG2 TWWSp4 HK1: Rh3 HK2: Rh3 B2 (+ 1 configuration) B3, Q3 (+ 2 configurations) 2 configurations 2 configurations

10 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 ZONE CONTROLLER Inputs, number Sensor Digital-/0..10V 2 fixed 1 HX Outputs, number Relay 3 fixed

RVS46.530

Connection to Operator units Extension modules Service tool Radio module BSB devices Service tool LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples

Designation AVS37.x9x (HMI) AVSx5.39x (max. 2 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI700.1 (including ACS790) e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging Contents CE1U2353en_01, CE1U2353en_01a

With/on Ribbon cable Ribbon cable "BSB" slot X60 slot Terminals CL-, CL+ "LPB" slot Terminals MB, DB

Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery Cable included in delivery Cable included in delivery

AC 230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 109 x 121 x 52 mm 431 g 1 piece or 20 piece

Compilation of partial diagrams as per CE1P2359_10. Partial diagram Rh3 Rh3 1 configuration

11 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 ZONE CONTROLLER Inputs, number Sensor Digital-/0..10V Connection to Operator units Extension modules Service tool Radio module BSB devices Service tool LPB devices Various plugs Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples 5 (3 fix, 2 BX) 1 HX Designation AVS37.x9x (HMI) AVSx5.39x (max. 2 modules) OCI700.1 (including ACS790) AVS71.390 (for BSB-RF) e.g. room units QAAxx OCI700.1 (including ACS790) e.g. LPB controller AGP4S..., AGP8S... Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CE1U2353en_01, CE1U2353en_01a Compilation of partial diagrams as per CE1P2359_10. Partial diagrams Sol1 and TWWSp5 and Rh3 With/on Ribbon cable Ribbon cable "BSB" slot X60 slot Outputs, number Relay

RVS46.543 5 (4 fix, 1 QX)

Designation AVS82.490/109, ...491/109 AVS82.490/109, ...491/109 Cable included in delivery Cable included in delivery Cable included in delivery

Terminals CL-, CL+ "LPB" slot Terminals MB, DB

230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 181 x 121 x 52 mm 587 g 1 pieces

Sol1 TWWSp5 Rh3

Q5, B6 Q3, B3 + 2 configurations 1 configuration

12 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Controller

ALBATROS2 SOLAR COMPACT CONTROLLER Inputs, number Sensor Digital 4 (1 fix, 3 BX) 1 fixed Outputs, number Triac PWM

RVA78.690 2 (1 fixed, 1 ZX) 1 fixed

Power supply Degree of protection Climatic conditions (operation) Ground Weight Packaging unit User Manual Plant diagram Examples

Voltage As per EN 60529 as per EN 60721-3-3 Length x Width x Height Excl. packaging includes CE1U2396en

230 V ~, 50/60 Hz IP 00 class 3K5, 0...50 (non-condensing) 158 x 215 x 53 mm 530 g 1 pieces

Compilation of partial diagrams as per CE1P2359_10. Plant diagram 1: Once collector field Q5 B6 Collector pump Q5 Collector sensor B6

13 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Extension and I/O modules

Extension and I/O modules


Extension modules

Product number Inputs, number Mains Sensor Digital-/0..10 V 5/12 V act. sensors Outputs, number Relay 0..10V/PWM Connection to Controller Extension modules BSB devices Expansion valve Operating voltage* Degree of protection Climatic conditions (operation) Dimensions (L x W) Weight (without packaging) Packaging unit

AVS75.370 1 EX 2 BX 2 HX 1 GX 3 QX 2 UX AVS82.490, ...491 AVS82.490, ...491 Terminals CL-, CL+ WX21 230 V ~, 50/60 Hz IP 00 -20...50 109 x 121 mm 248 g 1 or 20 pieces
*

AVS75.39x 1 EX (AVS75.391 only) 2 BX 1 HX

AGU2.550

AGU2.551

2 BX 1 HX 1 U+ (12 V)

3 QX

3 QX

2 QX 2 UX

AVS82.490, ...491 AVS82.490, ...491

AVS82.490, ...491 AGU2.110 AVS82.490, ...491 AGU2.110 Cl-, Cl+ to X50

AVS82.490, ...491 AGU2.110 AVS82.490, ...491 AGU2.110 Cl-, Cl+ to X50 12 V DC (via LMS) IP 00 0...60 108 x 55 mm 100 g 60 pieces

230 V ~, 50/60 Hz IP 00 -20...50 109 x 121 mm 293 g 1 or 20 pieces

12 V DC (via LMS) IP 00 0...60 108 x 55 mm 84 g 60 pieces

Additional technical data is available in the user guides for the controllers.

14 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Extension and I/O modules

I/O modules

Product number Inputs, number Sensor Digital-/0..10 V 5/12 V act. sensors Outputs, number Relay Triac Connection to Controller BSB devices Expansion valve Operating voltage* Degree of protection Climatic conditions (operation) Dimensions (L x W) Weight (without packaging) Packaging unit
*

AVS55.196 4 BX 3 HX 1 GX 4 QX 1 ZX AVS82.496/109 Cl-, Cl+ to X150 230 V ~, 50/60 Hz IP 00 (no housing) -20...50 96 x 122 mm 112 g 1 or 42 pieces

AVS55.199 4 BX 3 HX 1 GX 1 QX

AVS82.496/109 Cl-, Cl+ to X150 WX31 230 V ~, 50/60 Hz IP 00 (no housing) -20...50 96 x 122 mm 93 g 42 pieces

Additional technical data is available in the user guides for the controllers.

Compatibility
RVS21 AVS75.370 AVS75.39x AVS55.196 AVS55.199 AGU2.550 AGU2.551 Yes Yes Yes Yes Yes Yes RVS61 Yes Yes Yes Yes Yes Yes Yes LMS1x RVS13 RVS43 RVS63 RVS46

15 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Room and operating units

Room and operating units

Product number Language set 1 * Language set 2 ** Suited for plants Boiler Heat pump Operation cooling Cooling mode display Cooling button Communication Wire (BSB-W) RF (BSB-RF) Form and features 2) Room sensor, integrated Backlit display PCB version installation Wall Front plate Rear view Housing color Basalt grey White Functional scope Basic commands Complete command set
* ** 1) 2) 3)

QAA55.110, QAA58.110 No text No text QAA5x.110/301

QAA75.611, QAA78.610 QAA7x.61x/101, .../301 QAA7x.61x/501, .../701 QAA7x.61x/301, .../701 QAA7x.61x/301, .../701

AVS37.390 No text No text

AVS37.x9x AVS37.x9x/10x, .../30x AVS37.x9x/50x, .../70x 1) AVS37.x9x/309, .../709 AVS37.x9x/309, .../709 AVS37.x9x/309, .../709

QAA55.110 QAA58.110

QAA75.611 QAA78.610 QAA75.611

AVS37.29x 3) AVS37.39x 3) AVS37.294, AVS37.296

AVS37.295, AVS37.297

Language set 1 contains: DE, EN, FR, IT, NL, ES, DA, SV, FI, PT Language set 2 contains: EN, PL, CS, SK, SL, HU, EL, TR, RU, SR Reset button for LMS14/15: AVS37.x96 und AVS37.x97 Device dimensions and technical data in CE1U2358en_xx. Interfaces on partner devices in this document. On AVS37.296 the service buttons are on different, on AVS37.396 on the same level.

16 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Albatros2 communications

Albatros2 communications
Albatros2, communications, means:

Modern communications and visualization. Access up to the controller's energy savings functions. Apps for mobile end devices. Design by drag&drop own Web plant visualizations.

* with OZW672 only

17 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Albatros2 communications

Product number Designation Possible connections: Direct connection Direct dial connection GSM

OZW672... Web server for LPB/BSB USB, type A to mini-B No No

OZS164.23 Web server for LPB/BSB, GSM USB, type A to mini-B No Yes SMS commands (GSM modem integrated)

OCI611 Communication central control unit Zero modem cable, RS-232 No SMS info (GSM modem required) ACS790

OCI700 Service interface

USB, type A to B No No

Yes (requires modem) No

IP connection (Internet) Yes

Operation

Web browser GUI ACS790 HomeControl App LPB/BSB on Ethernet Web API

Web browser GUI SMS LPB/BSB on Ethernet LPB/BSB on GSM

ACS790

Protocol interface

LPB/BSB on RS-232

LPB/BSB on USB

Power supply Degree of protection Climatic conditions (operation) Dimensions (LxWxH) Weight

230 V ~, 50/60 HZ IP30 0...50 C 88 x 90 x 40 mm 136 g (without packaging) CE1N5712en CE1C5712en 1 pieces

100...240 V ~, 50/60 HZ IP30 0...50 C 88 x 135 x 40 mm (with antenna) 143 g (without packaging) CE1Q5711en CE1C5711en 1 pieces

230 V ~, 50/60 HZ IP30 (with terminal cover) 0...50 C 161 x 110 x 62 mm 320 g (without packaging) CE1N2533en

DC 5 V (as per USB specification) IP20 0...50 C 126 x 70 x 32 mm 1200 g (including case with ACS790 and packaging) CE1N5655en

Data Sheet Commissioning instructions Packaging unit

1 pieces

1 pieces

18 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Sensor

Sensor
Overview

Product number QAC34/101* Designation Sensing element Range Location Outside Flow rate TWW Boiler Solar Data Sheet Q1811 Outside sensor NTC 1K -50...70

QAD36/101, ../201

QAZ36.xxx/101, ../109

QAK36.xxx/109

QAR36.xxx/109

Strap-on Temperature temperature sensor sensor cable NTC 10K -30...125 NTC 10K -30...200 -25...95

Screw-on Strap-on temperature sensor temperature sensor NTC 10K -20...110 NTC 10K 5...125

Q1801 Q1843

Q1845

Q1806

* 2 additional order numbers are available relating to outside sensor QAC34/101: AVS13.399/101 AVS13.399/201 RF module including outside sensor QAC34 RF module for outside sensor QAC34; without the outside sensor.

19 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Accessories

Accessories
Cable

Product number Designation Length Protocol Links... With...

AVS82.490/109 AVS82.491/109 Ribbon cable 490/109: 400 mm 491/109: 1000 mm BSB Controller Operator unit or extension modules

AVS82.590/109 Adapter cable < 3000 mm* BSB Controller Operator unit or extension modules

AVS82.496/109 Ribbon cable 100 mm BSB Controller I/O module

AVS82.495/101 Service cable 3000 mm BSB Room unit (QAA7 ..) operator unit

AGU2.110A/109 Bus cable 840 mm BSB BMU LMS1... Operator unit or extension modules

* Cable between 2 adapters cannot exceed 3 meters for EMC reasons.

Gateways

Product number Designation Links... With... Description

OCI345.06/101 LPB clip-in RVS21.826 LPB RVS21 controllers is integrated in the LPB topology. On the controller 24 V DC (via RVS) IP 00 -20...60

OCI364.03/101 LPB/OT Gateway OpenTherm device LPB

AVS71.390/109* Radio module Controller BSB-RF (RF)

AVS71.393/101* RF module BSB BSB-W (Draft) BSB-RF (RF) RF communication controller/RF participant Freely placeable on BSB G+ (11.3...13.2 V) IP20 0...50 96 x 96 x 40 mm 115 g CE1U2358en 1 pieces

AVS14.390/101 Radio repeater BSB-RF (RF) BSB-RF (RF) RF signal amplification BSB-RF Within RF range of the RF participants 230 V ~, 50 Hz IP20 0...50 90 x 100 x 32 mm 112 g 195 g (power supply) CE1U2358en 30 pieces

Opentherm device is RF communication integrated in the controller/RF LPB topology. participant Freely placeable on OpenTherm via OpenTherm bus IP20 0...50 54 x 90 x 57 mm 76 g CE1Q2905de 20 pieces On the controller 5.5 V DC (via RVS) IP40 0...50 71 x 56 x 67 mm 54 g CE1U2358en 20 pieces

Installation location Power supply Degree of protection Climatic conditions (operation) Weight Documentation Packaging unit

Dimensions (LxWxT) 76 x 55 x 20 mm 54 g Controller manual 20 pieces

* RF module (AVS71.390) and RF module BSB (AVS71.393) as alternative only 20 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Accessories

Housing, covers, spacer

Wall-mount housing AGS7A.100 1 controller with width 181 mm 2 controller with width 109 mm HMI AVS37...

Blanking cover AVS38.291 e.g. with AGS7A.100 Dimensions: 138 x 92 mm

HMI cover (rear side) AVS92.290 For AVS37.x9x (not AVS37.390) Dimensions: 116 x 86 mm

Spacer AVS92.280/109 For extension module AVS55.19x For mounting on the basic module (RVS21...)

Power section
Power supply AVS16.290 Boiler control panel for floor-standing boilers Is connected using the supplied 5-pin plug to the controller's power input. Additional information is available in CE1U2358en

Demo case
Demo case KF8921.1 Demo case KF8900 Demo case for heating controller RVS... Includes, in addition to the room unit QAA75, the RF module AVS71.390, as well as potentiometer for plant simulation. Case dimenstions: 47 x 44 x 20 cm (L x W x D) Case weight:: 8 kg Demo case for heat pump controller RVS61 Includes, in addition to the room unit QAA75, the RF module AVS71.390, as well as potentiometer for plant simulation. Case dimenstions: 47 x 44 x 20 cm (L x W x D) Case weight:: 8.5 kg

21 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Additional information

Additional information
Albatros2 documentation landscape This product range description is a component of the Albatros2 documentation landscape.

Documentation type User guides for Albatros2 controllers [code letter U]

Contents Hardware and parameter description of controllers (see as well Section "Controller [ 4]", line "User's Guide")

User guides for Albatros2 operator, room, and Mounting and operating instructions, parameter description, and technical data in CE1U2358en_xx auxiliary devices [code letter U] Cross-product range basic documents [code letter P] Sensor datasheets [code letter Q] Product inserts [code letters B and G] Environmental declarations [code letter E] CE declaration of conformity [code letter T] e.g. "Hydraulic partial diagrams and supplemental functions" Technical data and functions (see Section "Sensor [ 19]", line "Datasheet") Delivered operating and mounting instructions Material product components, environmental compatibility, and compliance with environmental laws (e.g. RoHS) Declaration on the compliance with applicable electrical standards.

Additional support

For questions on the described products, please contact your point-of-contact at the responsible Siemens offices. http://www.buildingtechnologies.siemens.com/bt/partners/oem

Additional information

22 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Additional information

23 Siemens Building Technologies Controller, HMI and accessories CE1S2359 en 21.01.2013

Issued by Siemens Switzerland Ltd Infrastructure & Cities Sector Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies

2013 Copyright Siemens Switzerland Ltd Technical specifications and availability subject to change without notice.

Document ID Edition

CE1S2359 en 21.01.2013

Você também pode gostar