Escolar Documentos
Profissional Documentos
Cultura Documentos
Contents
1 RM BRIDGE V8I (SELECTSERIES 3) RELEASE ARCHIVE ................................................. 3 1.1 1.2 1.3 1.5 2 RM BRIDGE V8I (SELECTSERIES 3) 08.10.18.01 .......................................................................... 3 RM BRIDGE V8I (SELECTSERIES 3) 08.10.12.01 .......................................................................... 7 RM BRIDGE V8I (SELECTSERIES 3) 08.10.07.02 .......................................................................... 9 RM BRIDGE V8I (SELECTSERIES 3) 08.10.07.01 ........................................................................ 11
RM BRIDGE V8I (SELECTSERIES 2) RELEASE ARCHIVE ............................................... 12 2.1 2.2 RM BRIDGE V8I (SELECTSERIES 2) 08.10.03.02 ........................................................................ 12 RM BRIDGE V8I (SELECTSERIES 2) 08.10.03.01 ........................................................................ 12
RM BRIDGE V8I (SELECTSERIES1) RELEASE HISTORY ARCHIVE ............................. 12 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 3.26 3.27 RM BRIDGE V8I (SELECTSERIES 1) 08.09.96.02 ........................................................................ 12 RM BRIDGE V8I (SELECTSERIES 1) 08.09.94.01 ........................................................................ 13 RM BRIDGE V8I (SELECTSERIES 1) 08.09.91.03 ........................................................................ 14 RM BRIDGE V8I (SELECTSERIES 1) 08.09.91.02 ........................................................................ 14 RM BRIDGE V8I (SELECTSERIES 1) 08.09.91.01 TNDOT RELEASE ........................................ 15 RM BRIDGE V8I (SELECTSERIES 1) 08.09.90.01 ........................................................................ 15 RM BRIDGE V8I (SELECTSERIES 1) 08.09.86.01 ........................................................................ 17 RM BRIDGE V8I (SELECTSERIES 1) 08.09.84.02 ........................................................................ 19 RM BRIDGE V8I (SELECTSERIES 1) 08.09.84.01 ........................................................................ 19 RM BRIDGE V8I (SELECTSERIES 1) 08.09.83.01 ................................................................... 20 RM BRIDGE V8I (SELECTSERIES 1) 08.09.82.01 ................................................................... 20 RM BRIDGE V8I (SELECTSERIES 1) 08.09.81.02 ................................................................... 20 RM BRIDGE V8I (SELECTSERIES 1) 08.09.81.01 ................................................................... 20 RM BRIDGE V8I (SELECTSERIES 1) 08.09.79.01 ................................................................... 21 RM BRIDGE V8I (SELECTSERIES 1) 08.09.78.04 ................................................................... 21 RM BRIDGE V8I (SELECTSERIES 1) 08.09.78.03 ................................................................... 21 RM BRIDGE V8I (SELECTSERIES 1) 08.09.78.02 ................................................................... 21 RM BRIDGE V8I (SELECTSERIES 1) 08.09.78.01 ................................................................... 22 RM BRIDGE V8I (SELECTSERIES 1) 08.09.77.01 ................................................................... 22 RM BRIDGE V8I (SELECTSERIES 1) 08.09.76.05 ................................................................... 22 RM BRIDGE V8I (SELECTSERIES 1) 08.09.76.04 ................................................................... 22 RM BRIDGE V8I (SELECTSERIES 1) 08.09.76.03 ................................................................... 22 RM BRIDGE V8I (SELECTSERIES 1) 08.09.75.01 ................................................................... 23 RM BRIDGE V8I (SELECTSERIES 1) 08.09.74.01 ................................................................... 23 RM BRIDGE V8I (SELECTSERIES 1) 08.09.73.03 ................................................................... 23 RM BRIDGE V8I (SELECTSERIES 1) 08.09.73.01 ................................................................... 23 RM BRIDGE V8I (SELECTSERIES 1) 08.09.72.07 ................................................................... 24
RM BRIDGE V8I RELEASE HISTORY ARCHIVE ................................................................ 25 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 RM BRIDGE V8I 08.09.72.02 ....................................................................................................... 25 RM BRIDGE V8I 08.09.72.01 ....................................................................................................... 25 RM BRIDGE V8I 08.09.71.01 ....................................................................................................... 25 RM BRIDGE V8I 08.09.70.02 ....................................................................................................... 25 RM BRIDGE V8I 08.09.69.02 ....................................................................................................... 25 RM BRIDGE V8I 08.09.69.01 ....................................................................................................... 25 RM BRIDGE V8I 08.09.68.01 ....................................................................................................... 26 RM BRIDGE V8I 08.09.67.03 ....................................................................................................... 26
Bentley Systems
Austria
4.9 RM BRIDGE V8I 08.09.67.02 ....................................................................................................... 26 4.10 RM BRIDGE V8I 08.09.67.01 .................................................................................................. 26 4.11 RM BRIDGE V8I 08.09.66.03 .................................................................................................. 26 4.12 RM BRIDGE V8I 08.09.66.01 .................................................................................................. 26 4.13 RM BRIDGE V8I 08.09.65.02 .................................................................................................. 27 4.14 RM BRIDGE V8I 08.09.65.01 .................................................................................................. 27 4.15 RM BRIDGE V8I 08.09.63.01 .................................................................................................. 27 4.16 RM BRIDGE V8I 08.09.60.04 FIRST RELEASE........................................................................ 27 4.17 RM2006 VERSIONS < 9.59 ...................................................................................................... 28
Bentley Systems
Austria
Crack check: First existing LC as ptlc used if neither initial strain LC nor SumLc exists RunTCL: Access to assemblies with RUNTCL implemented. The following commands are allowed: RMASM asm-name GETALL [RECURSIVE] RMASM asm-name GETELEMS [RECURSIVE] RMASM asm-name GETTENDS [RECURSIVE] RMASM asm-name GETNODES [RECURSIVE] TINT: Time step width control added. This can solve some problems if the LC calculation at a certain time leads into "no convergence". Recalc Options: Check boxes for CS-Int disabled. Program takes always 1st option off and 2nd option on (UltRein). Program behavior in calculation not changed. DDE: The new default format for export is binary Excel (.xls), which is compatible with Excel2000 and higher. Wind: In rare cases one of the first modes has no component in wind direction. Calculation detects these cases and modifies parameters accordingly. DOPLOT: Usage of assemblies RMSET: Usage of assemblies 3D-View: Usage of assemblies OpenTCL: LIST: SUMLIST now allows to export values out of GUI 'Load case list' to list file OpenTCL: LIST: ELEM fixed and extend for CABLE and all SPRING
Bentley Systems
Austria
OpenTCL: LIST: VOLUME now allows to printout volume and weight of active structure in list file. - FEM: Thicknesses for inclined thickness vectors corrected - FEM: Area defined loads - FEM: Area defined masses - FEM: New graphical output facilities for results - RMSET: New sorting of elements needed because of assemblies, but useful for all element definitions; given direction +X, -X, +Y, -Y, +Z, -Z - 3D-View: New option Draw element directions - Element-Info dialogue improved (graphic presentation of the element) - Cantilever Tool: New menu structure - RESVIEW: Navigation tool for view directions added - 3D-Results: New color distribution method - Extended view options with the possibility to select multiple assemblies to be displayed. - AASHTO Steel: Change of concept for condition for stiffened or not stiffened in shear - Creep and shrinkage plots will use magenta instead of yellow color to improve the visibility on white background & paper print outs RM Modeler - Auto-meshing (including documentation and training) available - Steel profile import with wizard style - Changed Modeler option "Include wizard-originating objects" to "Omit wizard-originating objects" and changed the default status to include wizard generated objects. Moved option for ResView data to the files section in the main dialog (removed in extended dialog) RM Wizards - Russian composite wizard available - Reports in Russian RM2Rebar - New Version of XML(v.1.4) provides much faster export. Please note that this RM release 08.10.18.01 is compatible with Bentley Rebar v08.11.09.74 and Power Rebar 08.11.09.74 or higher. If that release is not available on SELECT please contact JeanPierre Chanard or Nabil Sleiman. - Added option to allow creation of XML along with DGRM file in export dialogue. - Added export of material name and type for beam elements. - Added export of cable elements (geometry) and their material name and type RM General - Licensing: Improved SELECT licensing configuration. Activated the new v9 SELECT Licensing client 9.0.0.38 - DGN Navigator 2.1.0.252 will be used. It's more stable as the previous one.
Bentley Systems
Austria
Training examples available within RM session Added user guide GUI commands in TCL Guide Added TCL commands for Multibyte UTF8 conversion. Also the documentation was updated accordingly. Added TCL demo examples in area of Demo examples Export of PDF (3D) is now available again in the context menu of the RM graphic window. You need the free Bentley Viewer or Microstation to use it. First a DGN file will be created and opened in the Viewer. There it can be printed as PDF file. Excel TCL export: Creates binary xls files accepted without notification also by newer Excel versions. RM is now faster while starting with network paths, which don't exist anymore and are registered in the project history. Working directories longer than 169 characters will use the short 8.3 name convention.
Fixes: RM/Analysis - Aero class calculation corrected (Calculation of derivatives of steady state coefficients corrected. Wind direction -Z were wrong (no symmetry to +Z). Numerical differentiation difficult at kinks. Now, approximation at kinks by averaging. NOTE: THIS MODIFICATION INFLUENCES OLD PROJECTS. THE NEW RESULTS SHOULD BE BETTER (SMOOTHER DERIVATIVES).) - Creep/Shrinkage: AASHTO LRFD adapted maturity factor - TCL import of CSCORB/CSCORE: Sum load case were not imported - TCL import of Chinese file names now possible - TCL import/export: New TCL option "NO_CREEPSHRINK" by exporting schedules. This option is not known in older versions. Thats why a warning will appear during import in the older versions. This is OK, but, another very old bug causes an empty error list (to be ignored). - LIVESET did not take Q-load if it was defined on other item than the 1st one - Swedish Classification trains: Tolerance of inner optimization modified to speed up calculation - TINT: Wrong output of force components in XLS. Note, that local element displacements are output. - Stress results: If stress points flagged for storing stresses independently from the strain plane, stresses in envelopes of composite structures might be still become 0 (composite-split-situation with SUPAND/SUPOR). New option to force recalculation of sigma = E * eps, even the point is flagged (SP+), introduced for GUI-list and RMSET. By the way, keeping the chosen stress point and easier selection of superposition row implemented for GUI list. - PreTens: Assembly as alternative input to RMSET.
Bentley Systems
Austria
Binary Xls export for Ansi characters with code page (, , etc) are now exported correctly. If Windows Open File / Save File dialogs were applied by double-clicking a file, the second button up event could have invoked a click to some button in the below window which might have caused accidental execution of the respective action (e.g. Import TCL --> Add to project). Fixed to catch all situations. Fixed the problem that the path of the last used TCL file has not been used on opening the file selection dialog. Stage simulation: External Tendons elements are now shown as "active" after STRESS action. RM Loads: Adding a load item of type load set is now returning the list of loads correctly. TCL Import: Added safety query in TCL import dialog before initializing the RM database.
RM/Modeler RM/Wizards - Geometry for curved alignment with skewed piers at begin and end corrected
Fixes which are also available in patch release v08.10.12.02: RM/Modeler Cross sections: After TCL import using a length unit other than Meter expressions of CS variables were not evaluated correctly to DB units. RM/Modeler Cross sections: After importing a CS from catalogue to a project using a length unit other than Meter the expression column of CS variables list did not show the correct value in user units. RM GUI/Element Cross section: For units other than DB the values changed by editing element type in modify dialog. RM Cross section: Variables for non linear springs didnt work. RM GUI & Plot file viewer: Dotted/dashed lines were solid in interactive graphics. That happened only for Unicode/Russian language support with new Unicode graphic fonts RM Rolling stock: Data storage did not work properly due to missing texts RM Loads: Copying schedules did not transfer correctly load set items containing assemblies. RM/Modeler Segments: Editing a segment did not allow to input names containing one of the 3 hot-keys used by this dialog (in English: o, c, and a) RM Export: Fixed wrong keyword (correctly DAMPV instead of DAMPT) for structural data of aero classes.
Bentley Systems
Austria
Fixes and improvements: RM load train: GUI for "Load Train - Brazilian NBR 7188:1984 Classe 45" added RM Tcl: Clusters can be optionally exported
Bentley Systems
Austria
Wizards: Update combination table for EC by adding a 14th combination Wizards: A wizard with more than 20 spans could not re-read all span lengths when opening the wizard again. Pier type Columns in Wizards: Pier type activated for precast, composite and steel wizard XLS export improved GUI: Fixed problem with Windows Vista, Windows7/8 desktop composition. Now freehand symbols work fast and smooth GUI: User Theta for shear check was not properly presented in GUI pad - fixed RM Materials: SIGP = 0.74*fpu RM Load Cases: Database problem with directly defined load items fixed. RM Buckle: Crash if "Acc. Stiffness" due to invalid close of external load case problem fixed. DGN Import: Support for arcs added. RM ULTREIN: Consideration of sleeve length produced division by 0. Now, tendons at such element positions ignored. RM Load-Sets: Copying load sets / load cases did not copy the assembly information of contained load items. Modeler Recalc: Wrong management of attribute sets at segment points could produce corrupt database. Corrected. RM: Fixed wrong conversion of inverse temperature values, esp. alpha-T of element/material and temperature. Modeler: Axis redraw showed small arcs with big radius as full circle when begin and end point collapsed into the same pixel. Corrected. GUI: The layout has changed: the navigation square in the bottom right corner is gone and the size of the log area is now adjustable with a slider. Some pads (subwindows) which do not produce messages are enlarged to cover the log area. RM Load-Sets: Selecting an assembly was possible even if series input was activated in load input pads fixed. Wizards: Crash calculating distance between girders - fixed Wizards: Function that calculates distance to axis failed in some cases. Corrected. This bug was the reason that load calculation failed and all further writing of schedule was skipped. The concept is changed now: Even if any load could not be written, the transfer is not completely stopped now. RM Load-Sets: Checking for correct series input correctly showed an error message but continued with applying the false input. RM Load-Sets: QVAR** load input dialogs did "convert" the direction vector using a factor of 0 (--> division by zero). Corrected. RM cross sections: Values of the flexibility matrix were not shown and/or stored properly in the modification dialog fixed DGN Export: Solids were wrongly exported fixed RM Stage simulation: temperature load values were always converted to Fahrenheit, also for default units, conversion was wrong fixed
Bentley Systems
Austria
Fixed wrong output of superposition results in RMSets when using non-DB (imperial) units. Fixed a crash which could have occurred after exporting the 3D structure to DGN Fixed wrong TCL import of separated summation load cases for ILM Fixed Undo function in Modeler CS construction window Enhancement: Output of moments about global axes in load case list Enhancement: Shear capacity check: EN 1992 Shear check improved Steel design check: Fixed problem if Euler length is zero. RM Cross Sections: Geometrical analysis of cross sections for perimeters failed in seldom cases. Analysis corrected and check procedure implemented that such cases are recognized earlier. Warnings after cross section calculations will occur. RM: GUI Input of PT-force for tendon series failed if imperial units was chosen RM Creep: The time functions are modified for Hong Kong standard in rm9_HK.tcl. Now the corresponding internal implementation is adjusted. RM Creep: Missing time functions (internal formulas) for AS3600-2009 added; relaxation for AS5100-1 adjusted acc. to external formulas (rm9_AU.tcl) RM TINT: Output format for displacements: Deformation factor applied RM Material: Change of Relaxation Class in material table for British Standard from value 1 to value 2. Wizards: Allow arbitrary number of spans instead of not more than 20.
Bentley Systems
Austria
Bentley Systems
Austria
Fixes and improvements: Due to the unlimited number of project history items setting up the history list could have caused long delays on program startup. Fixed by limiting the number of items. TCL-import: Import of Modeler files extremely speeded up Added license and default code for Thailand Added license entry for Chinese response spectrum macro Modeler: segmentation type was not stored anymore. Corrected. Tendon calculation revised (smoother alignment). Since structure is changed, all results may slightly differ. Tendons used in a PreTens action were not shown active in stage simulation window. Fixed. Response spectrum analysis: Full implementation of CQCX using TDVSuperposition method (+ extremely speeded up) Response spectrum analysis: Stabilization of de-composition of correlation matrix for CQC and CQCX using TDV-Superposition method Response spectrum: New input macro for AASHTO LRFD 2012 ULTSUP, ULTLC (REIN): Extended list file for JTG Modeler: table graph was not exported to plot file correctly - fixed Load case list: Output of moments about global axes DGN: Switch to new platform libraries License: Fixed a problem that for node-locked licenses a proper country was not found for non-international standards mode
Bentley Systems
Austria
Bentley Systems
Austria
Program crashed in stage simulation of tendon numbers higher than 16384 were used Input Macro4 for load lane definition didnt work for element number higher than 32768 Program crashed in module LiveL for composite structures with active stress point results For module TInt correction of variable t with tstart is no longer ne cessary. Improved stability of non-linear calculation with option no compression for non-linear cables RM Bridge Modeler: - Show filtered list of attribute sets for current cross section - Input default diameter and area for reinforcement attribute sets - Stronger type-checking when assigning reference set to attribute set. RM Bridge Wizards: - Added option to place vertical stiffener on steel girders without cross frame.
Bentley Systems
Austria
Load types CSCORB and CSCORB were not activated for elements. Module UltSup for reinforcement design (with option Rein active), did not properly consider pre-stressing forces if they were specified with option * for the initial strain load-case. RMBridge Modeler: - Improved auto-enumeration of segment points. - Bug fixes: If auto-numbering exceeded available pool of numbers, user was not notified. Serial input of springs didnt take correct connection point into account. RMBridge Wizards: - Added option for calculation of pre-stressing losses to wizard Precast Girder. - Added input of initial longitudinal reinforcement for wizard Steel (Concrete Deck). - Bug fixes: Temporary support conditions in wizard Precast Girder inappropriate.
Bentley Systems
Austria
Bentley Systems
Austria
Start->All Programs->Bentley->RM Bridge-> RM Bridge Prerequisites Pack(BaseWin) Release Notes Design codes and checks: - Beta version of Canadian shear and crack check available - Beta version of shear check according to OEN B 1992 accessible via EC OENORM Bug fixes: - Auto-numbering of elements and nodes failed in Modeller if several composite definitions were present in one cross section - Project initialization from an empty project directory did not automatically select the according default standard for the available national license - Modeller failed to open if material group HS_HONG_KONG was active - Program crash if two or more points of an ISP definition for external tendons were at same 3D point - Schedule action TStop was not accumulative, now up to four distinct time stop periods are supported. - If FEM model was exported to analyser with option "Keep model data", integral results were not fully exported - Newly created external tendon element became statically active only after second structure check calculation - If two different factors for SupAnd(X)Lc or SupOr(X)Lc were given in TCL for combination table, a warning was issued, but the wrong factor (favourable) was used for calculation. Now the unfavourable factor is used and the factor to be used is included in the warning message. - Buckling calculation reported wrong results if fixed and variable loadsets were mixed in loadcase. Now also the forces are reported as in RM2006. - Material selection in modeller hid the default group in some cases. Now the default group is shown as a separate menu, right after the current group. - In modeller cross section GUI, dependency of element edge was not shown correctly in Modify Reference Point dialog. Hambly calculation didn't work since version 08.09.84.02 - Element -type "Damper-Spring" was not properly implemented - FEM Integral results not updated for Eigenvalue calculation - FEM Integral results not considered in superposition for modules RespS and Wind - Modeller TCL export of FEM integral result definition, construction line parameters - Spurious oscillations in tendon geometry if one angle was fixed and the other one free - Problem with correlation matrix for superposition rule CQC (reported negative pivot in correlation matrix) - Variable factor for load-type DEMO was not considered - Changing units for project settings also changed time dependent variables - Creating 0-Springs without connection point
Bentley Systems
Austria
Bentley Systems
Austria
Influence line results for integral results of type line in FEM model contained wrong results for forces. Module DoRep reported meaningless error messages if CALC actions for non-defined loadcases were present in schedule. For pier dimensioning moments were increased sometimes, even if no according PIERDIMY/Z keyword was present in the RMSet TDF reports contained wrong formatted data for load type T Conversion of acceleration into displacement time histories with option calibrate failed in some cases. Program crashed if variables of type table with more than approx. 4000 lines were plotted. Sometimes the macro Cable Length Under Loading did not produce any output. Cantilever tool crashed for very large projects.
Bug-Fixes: - If tendon is defined in negative element direction, spurious oscillations were shown in plot created by PlTndGm - If a cross section contains too much Reference Sets, the TCL command RMCPART part REFSET GETALL resulted in a program crash. This affected also Shear Check calculation. - LoadSet factors and Loadcase/Envelope name for load type DEMO were not properly copied in GUI. - GUI was not properly updated if lines in a variable table were added/deleted. - Overflow of results was reported when Tendon area was 0. - Influence line results for integral results of type line in FEM model contained wrong results for forces. - Module DoRep reported meaningless error messages if CALC actions for non-defined loadcases were present in schedule. - For pier dimensioning moments were increased sometimes, even if no according PIERDIMY/Z keyword was present in the RMSet - TDF reports contained wrong formatted data for load type T - Conversion of acceleration into displacement time histories with option calibrate failed in some cases. - Program crashed if variables of type table with more than approx. 4000 lines were plotted. - Sometimes the macro Cable Length Under Loading did not produce any output. - Cantilever tool crashed for very large projects.
Bentley Systems
Austria
The new product for Precast Segmental Bridges RM Bridge Cast was added to the installation set. It is a standalone application and is started in the start menu :
-> All Programs->Bentley\RmBridge\RM Bridge V8i (SELECTseries 1) V08.09.xx.xx ->RMCast V08.09.xx.xx
It requires the new SELECT license product RM Bridge Cast. The detailed description can be found in the RMCast main menu ->Help->User Guide.
Bentley Systems
Austria
Bentley Systems
Austria
Solved problem for module Restart and destination load case with direct load input. Updated automatic conversion of plot files into DGN/DWG. With the previous release the license client was incorrectly displaying the disconnected notification dialog on the first launch of the application. Fixed : Bentley Licensing client updated to v8.11.07.39. Spanish shear capacity check revised according to EHE 2008.
Bentley Systems
Austria
Solved problem in actionPlTndGm where projection into plan failed if Tendon direction against Beam direction. Improved evaluation of aero class tables. Improved pre-processor for Moving Load available. Extended precast wizard with new column types for rectangular-chamfered, rectangular-filleted, hexagonal, and octagonal shape (requ. for TDOT) Improved issues for TDOT drawings
Bentley Systems
Austria
Plot file viewer description for German localisation available in the main menu Help/Hilfe.
1e-7 1e-7 1e-7 1e-7 1e-7 1e-7 1 1 1 1 FFIX FFIX FFIX FFIX
RM/Load types: Primary results were not considered for "DEMO" of springs. RM/Shear Check LRFD2007 implemented RM/Standards: Change EHE default time function from CEB90 to EN1992 Module Eigen stored incorrect results to mode-shape load cases if calculation option Large displacements is selected.
Bentley Systems
Austria
Bentley Systems
Austria
Bentley Systems
Austria
Bentley Systems
Austria
Bentley Systems
Austria
RM/Cantilever: The program is part of RM and can be chosen in the RM menu Bridge Modeller RM/LandXML: Road planning data and DTM can be imported RM/Graphics: Additional output formats (DGN, DWG, 3D-PDF) RM/Draw manager: Powerful generation of DGN/DWG drawings with direct connection for Bentley Projectwise Navigator RM/Data Exchange: Access to Bentley Projectwise Server RM/LiveLoad: Option Improved Live Load Calculation is always on. RM/LiveLoad: 2D influence line calculation RM/Cross section: Higher precision on calculation of shear stresses for composite RM/Tendon points: The constraints for the 2 angles are treated separately. RM/Tendon stressing/grouting: Extended system checks for activation
Bentley Systems
Austria