Topic Options Coade Tank 3.30 - Net Area at Roof/Shell Junction (A) eugeneee Dear All,
Member Registered: 04/27/10 Posts: 6 Loc: turkey #46430 - 12/29/11 06:11 AM

Who's Online 3 registered (LeviM, kovalogi, 1 invisible), 11 Guests and 4 Spiders online.
Key: Admin, Global Mod, Mod

Pls refer to the roof specification parameters menu of the Coade Tank - General Roof Specs - Net Area at Roof/Shell Junction (A) Coade Tank software send us to Appendix F and the related formula is as below (acc. to API 650 2009 Appendix F.5.1) A = 220(D^2)x(Pi-0.08 ti)/(Fy x Tan0) D : Diamater Pi : Internal Design Pressure My question is that if the internal design pressure is zero (athmospheric tank) then Junction Area (A) will be minus value. Is there any calculation method for the Junction Area (A) ? Thanks for the help

January Su M Tu W Th F Sa 1 5 6 7 8 2 3 4 9 10 11

12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Forum Stats 9421 Members 13 Forums 12225 Topics 55267 Posts


Max Online: 57 @

12/06/09 11:14 AM

Top

Re: Coade Tank 3.30 - Net Area #46484 - 01/02/12 01:14 PM at Roof/Shell Junction (A) [Re: eugeneee] mariog
Member Registered: 09/29/07 Posts: 395 Loc: Romania

eugeneee, Any time you get a negative term there, it means the internal pressure effect is less than the weight of roof plates. Under Figure F-1Appendix F Decision Tree, you are in case Does internal pressure exceed weight of roof plates? IF No GO TO Basic Design The basic design includes dimensional provisions for the elements participating to that area. See 5.10.2.2 Roof plates shall have a minimum nominal thickness of And 5.6.1.1 the shell thickness shall not be less than the following. And

65.57.255.42/ubbthreads/ubbthreads.php?ubb=showflat&Number=46484

1/2

1/14/14

Coade Tank 3.30 - Net Area at Roof/Shell Junction (A) - Intergraph CADWorx & Analysis

5.1.5.9 Roof and Top-Angle Joints, point e e. Except tank shells shall be supplied with top angles of not less than the following sizes. So there is an inherent minimum area required by API650 Basic Design. You would check if it is adequate- e.g. for loads as wind roof uplift and wind on shell, if you construct a model to calculate such things. Such calculation is out of API 650. Best regards.
Top

Previous Topic

Index Next Topic

Moderator: Luis Sanjuan, Richard Ay

Hop to:

TANK

Go
Contact Us Home Page Top

Privacy statement Board Rules Mark all read

GooG_v2_copy_copy_copy

Generated in 0.089 seconds in which 0.031 seconds were spent on a total of 15 queries. Zlib compression disabled. Powered by UBB.threads PHP Forum Software 7.5.7

65.57.255.42/ubbthreads/ubbthreads.php?ubb=showflat&Number=46484

2/2

Você também pode gostar