A xenon arc lamp is a specialized type of gas discharge lamp, an electric light that produces light by passing electricity

through ionized xenon gas at high pressure. It produces a bright white light that closely mimics natural sunlight. Xenon arc lamps are used in movie projectors in theaters, in searchlights, and for specialized uses in industry and research to simulate sunlight. Xenon headlamps in automobiles actually use metal-halide lamps where xenon arc is only used during start-up.

Types
Xenon arc lamps can be roughly divided into three categories:

Continuous-output xenon short-arc lamps Continuous-output xenon long-arc lamps Xenon flash lamps (which are usually considered separately)

Each consists of a glass or fused quartz arc tube with tungsten metal electrodes at each end. The glass tube is first evacuated and then re-filled with xenon gas. For xenon flashtubes, a third "trigger" electrode usually surrounds the exterior of the arc tube. The lamp has a lifetime of around 2000 hours.

History and modern usage

An Osram 100 W xenon/mercury short short-arc lamp in reflector Xenon short-arc arc lamps were invented in the 1940s in Germany and introduced in 1951 by Osram. First launched in the 2 kW size (XBO2001), 001), these lamps saw wide use in movie projection, , where they replaced the older, more complicated carbon arc lamps. . The white, continuous light generated by the xenon arc is spectrally similar to daylight, but the lamp has a rather low efficiency in terms of lumens of visible light output per watt of input power. Today, almost all movie projectors in theaters empl employ oy these lamps, with power ratings ranging from 900 watts up to 12 kW. Omnimax (Imax Dome) projection systems use single xenon lamps with ratings as high as 15 kW.

Lamp construction

An end-view of a 15 kW IMAX lamp showing the liquid liquid-cooling ports All modern xenon short-arc arc lamps use a fused quartz envelope with thoriated tungsten electrodes. Fused quartz is the only economically feasible material currently available that can withstand the high pressure (25 atmospheres for an IMAX bulb) and high temperature present in an operating lamp, while still being o optically clear. The thorium dopant in the electrodes greatly enhances their electron emission characteristics. s. Because tungsten and quartz have different coefficients of thermal expansion expansion, , the tungsten electrodes are welded to strips of pure molybdenum metal or Invar alloy, which are then melted into the quartz to form the envelope seal. Because of the very high power level levels involved, large lamps are water-cooled. cooled. In those used in IMAX projectors, the electrode bodies are made from solid Invar and tipped with thoriated tungsten. An O-ring seals off the tube, so th that at the naked electrodes do not contact the water. In low power applications the electrodes are too cold for efficient electron emission and are not cooled; in high power applications an additional water cooling circuit for each electrode is necessary. To save ave costs, the water circuits are often not separated and the water needs to be deionized to make it electrically non non-conductive, conductive, which, in turn, lets the quartz or some laser media dissolve into the water.

Perspective view of 3 kW lamp showing plastic safety shield used during shipping. In order to achieve maximum efficiency, the xenon gas inside short short-arc arc lamps is maintained at an extremely high pressure up to 30 atmospheres (440 psi / 3040 kPa) which poses safety concerns. If a lamp is dropped, or ruptures while in service, pieces o of f the lamp envelope can be thrown at high speed. To mitigate this, large xenon short short-arc arc lamps are normally shipped in protective shields, which will contain the envelope fragments should breakage occur. Normally, the shield is removed once the lamp is ins installed talled in the lamp housing. When the lamp reaches the end of its useful life, the protective shield is put back on the lamp, and the spent lamp is then removed from the equipment and discarded. As lamps age, the risk of failure increases, so bulbs being replaced placed are at the greatest risk of explosion. Because of the safety concerns, lamp manufacturers recommend the use of eye protection when handling xenon short short-arc lamps. Because of the danger, some lamps, especially those used in IMAX projectors, require the t use of full-body protective clothing.

Light generation mechanism


Xenon short-arc arc lamps come in two distinct varieties: pure xenon, which contain only xenon gas; and xenon-mercury, mercury, which contain xenon gas and a small amount of mercury metal. In a pure xenon lamp, the majority of the light is generated within a tiny, pinpoint-sized pinpoint cloud of plasma situated where the electron stream leaves the fa face ce of the cathode. The light generation volume is cone-shaped, shaped, and the luminous intensity falls off exponentially moving from cathode to anode. Electrons passing through the plasma cloud strike the anode, causing it to heat. As a result, the anode in a xenon short short-arc arc lamp either has to be much larger than the cathode or be water-cooled, cooled, to dissipate the heat. The output of a pure xenon short short-arc arc lamp is relatively flat over the entire colour spectrum,[citation needed] though even in a high pressure lamp there are some very strong emission lines in the near infrared, roughly in the region from 850 850900 900 nm. This spectral region can contain about 10% of the total emitted light. In xenon-mercury short-arc arc lamps, the majority of the light is generated in a pinpoint-sized pinpoint cloud of plasma situated at the tip of each electrode. The light generation volume is s shaped haped like two intersecting cones, and the luminous intensity falls off exponentially moving towards the centre of the lamp. Xenon-mercury mercury short short-arc lamps have a bluish-white white spectrum and extremely high UV output. These lamps are used primarily for UV curing applications, sterilizing objects, and generating ozone.

The very small size of the arc makes it possible to focus the light from the lamp with moderate precision. For this reason, on, xenon arc lamps of smaller sizes, down to 10 watts, are used in optics and in precision illumination for microscopes and other instruments, although in modern times they are being displaced by single mode laser diodes and white light supercontinuum lasers which can produce a truly diffraction limited spot. Larger lamps are employed in searchlights where narrow beams of light are generated, or in film production light lighting ing where daylight simulation is required. arc lamps generate substantial ultraviolet radiation. . Xenon has strong spectral All xenon short-arc lines in the UV bands, and d these readily pass through the fused quartz lamp envelope. Unlike the borosilicate glass used in standard lamps, fused quartz does not attenuate UV radiation unless it is specially doped. . The UV radiation released by a short short-arc arc lamp can cause a secondary problem of ozone generation. The UV radiation strikes oxygen molecules in the air surrounding the lamp, causing them to ionize. Some of the ionized molecules then recom recombine as O3, ozone. Equipment that uses short-arc arc lamps as the light source must contain UV radiation and prevent ozone buildbuild up. Many lamps have a low-UV UV blocking coating on the envelope and are sold as "Ozone Free" lamps. Some lamps have envelopes made ou out of ultra-pure synthetic fused silica (such as "Suprasil"), which roughly doubles the cost, but which allows them to emit useful light into the vacuum UV region. . These lamps are normally operated in a pure nitrogen atmosphere.

Ceramic xenon lamps

A Cermax 2 kW xenon lamp from a video projector. A pair of heatsinks are clamped on the two metal bands around the perimeter, which also double to supply power to the lamp Xenon short-arc arc lamps also are manufactured with a ceramic body and an integral reflector. They are available in many output power ratings with either UV tr transmitting ansmitting or blocking windows. The reflector options are parabolic (for collimated light) or elliptical (for focused light). They are used in a wide variety of applications, such as video projectors, fiber optic illuminators, endoscope and headlamp lighting, ng, dental lighting, and search lights.

Power supply requirements

A 1 kW xenon short-arc arc lamp power supply with the cover removed. Xenon short-arc lamps are low-voltage, voltage, high high-current, DC devices with a negative temperature coefficient. . They require a high voltage pulse in the 20 2050 kV range to start the lamp, and require an extremely well regulated DC power source. They are also inherently unstable, prone to phenomena such as plasma oscillation and thermal runaway. . Because of these characteristics, xenon short-arc arc lamps require a sophisticated power supply to achieve stable, long-life long operation. The he usual approach is to regulate the current flowing in the lamp rather than the applied voltage. As an example, a 450 W lamp operates normally at 18 V and 25 A.

Automotive headlamps
In 1991 "xenon headlamps" " were introduced for vehicles. These are actually metal-halide metal lamps; the xenon gas is used only to provide some light immediately upon lamp startup, as required for safety in an automotive headlamp application. Full intensity is reached 20 to 30 seconds later once the salts of sodium and scandium are vapourised by the heat of the xenon arc. The lamp envelope is small and the arc spans only a few millimetres. . An outer hard glass tube blocks the escape of ultraviolet radiation that would tend to damage plastic headlamp components. The first xenon headlamp burners contained m mercury; newer types do not.

Xenon long-arc-lamps lamps


These are structurally similar to short short-arc lamps except that the arc-containing containing portion of the glass tube is greatly elongated. When mounted within an elliptical reflector, these lamps are frequently used to simulate sunlight. Typical uses include solar cell testing, solar simulation for age testing of materials, rapid thermal processing, and material inspection.

XBO lamps
XBO lamps are short arc lamps in which the discharge arc fires in a pure xenon atmosphere under high pressure. XBO lamps have a very good color rendering and extremely high luminance. For this reason they are often used in light guide systems, e.g., for endoscopy or dental technology.