Bio Zapper v2.

1
http://www.ekovortex.com/ 1. Specifications Frequency adjustment from 1 Hz to 1000000 Hz (1MHz) with 1 Hz resolution Setting running time 1-240 minutes with 1 min resolution Memory the last used settings (No need every time adjusts frequency and time) Can memory 20 programs, and each program can have up to 10 different frequency's and running times Generates a rectangular signal amplitude 12 V with a positive offset of 0.25V Adjustable Duty Circle from 10 to 90 % (Increased zapping efficient) Sweep function (If you activate sweep function, then he will generate frequencies around desire frequency whit adjusted sweep) Buzzer (You will be inform when adjusted time is passed) Frequency Stability +/- 0.01% (Frequency is generated by a microprocessor that runs on 20Mhz crystal oscillator) Double outputs External power supply 12 VDC Protection against short-circuit

Frequency list: http://www.ekovortex.com/FrequencyList.html

Disclaimer
Bio Zapper is well-made, reliable devices that produce rectangle waveforms. We make no claims regarding Bio Zapper healing or healing properties. If you suffer from a persistent or life threatening condition, we recommend that you seek the help of a doctor or medical specialist who is qualified to help you. Use of Bio Zapper is at your own risk.

Page 1 of 6

Bio Zapper v2.1


http://www.ekovortex.com/ 2. Instructions Legend Start/Stop button Arrow left Arrow right Arrow down Arrow up Normal zapping Bio Zapper v2.1 Step 1. This is starting screen Press arrow down Step 2. Use left and right arrows to set Duty Circle. Default value is 50% After that press arrow down Step 3. Use left and right arrows to set frequency After that press arrow down Step 4. Use left and right arrows to set time After that press arrow down Step 5. This screen shows adjusted frequency and time Press start/stop Step 6. Bio zapper is now ready to start producing adjusted frequency Press start/stop to start zapping, or if you want to change settings press arrow down (step 2) Step 7. Zapping is started Here you can see adjusted frequency and time counting down Whit start/stop is possible to stop zapping any time (step 9) Step 8. When adjusted time reach 0, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2) Step 9. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2) Page 2 of 6

Set DC [%] xx Set Freq [Hz] xxxxxxx Set Time [min] xxx Freq:xxxxxxx [Hz] Time:xxx [min]

BioZapper v2.1 Ready to start

Running f:xxxxxxx

t:xxx

Stopped by timer

Stopped by user

Bio Zapper v2.1


http://www.ekovortex.com/ Making programs Bio Zapper v2.1 Step 1. This is starting screen Press arrow down Step 2. Use left and right arrows to set Duty Circle. Default value is 50% After that press arrow down Step 3. Use left and right arrows to set frequency After that press arrow down Step 4. Use left and right arrows to set time After that press arrow down Step 5. This screen shows adjusted frequency and time Press arrow down Step 6. Press start/stop

Set DC [%] xx

Set Freq [Hz] xxxxxxx

Set Time [min] xxx

Freq:xxxxxxx [Hz] Time:xxx [min]

Save to program

Program:x

Step 7. Use left and right arrows to set program After that press arrow down Step 8. Use left and right arrows to set program step Press start/stop to save adjusted frequency and time or arrow down if you dont want to save (step 2) Step 9. Adjusted frequency and time is saved in program After 1 second BioZapper will go on step 3

Step:xx

Program saved

Page 3 of 6

Bio Zapper v2.1


http://www.ekovortex.com/ Running programs Bio Zapper v2.1 Step 1. This is starting screen

Set DC [%] xx

Run Program

Step 2. Use left and right arrows to set Duty Circle. Default value is 50% Press arrow down until you reach next screen Step 3. Press start/stop Step 4. Use left and right arrows to choose program Press start/stop to start program, or if you want to change settings press arrow down (step 2) Step 5. Bio zapper is now ready to start program Press start/stop to start zapping, or if you want to change settings press arrow down (step 2) Step 6. Zapping is started P Program number / S Step number F Frequency / t Time Bio Zapper will run all steps where programmed time is higher then 0 with adjusted Duty Circle Step 7. After last step is finished, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2) Step 8. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)

Program:xx

BioZapper v2.1 Ready to start

Running P:xx S:xx f:xxxxxxx t:xxx

Stopped by timer

Stopped by User

Page 4 of 6

Bio Zapper v2.1


http://www.ekovortex.com/ Running Sweep Bio Zapper v2.1 Step 1. This is staring screen Press arrow down Step 2. Use left and right arrows to set Duty Circle. Default value is 50% Press arrow down Step 3. Use left and right arrows to set middle frequency Press arrow down Step 4. Use left and right arrows to set time Press arrow down Step 5. This screen shows adjusted frequency and time Press arrow down until you reach next screen Step 6. Press start/stop Step 7. Use left and right arrows to adjust sweep frequency Step 8. Bio zapper is now ready to start sweep Press start/stop to start zapping, or if you want to change settings press arrow down (step 2)) Step 9. Zapping is started Here you can see current frequency and time counting down Whit start/stop is possible to stop zapping any time Step 10. When adjusted time reach 0, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2) Step 11. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)

Set DC [%] xx

Set Freq [Hz] xxxxxxx

Set Time [min] xxx

Freq:xxxxxxx [Hz] Time:xxx [min] Run Sweep

Mid freq:xxxxxxx Sweep:xxxxxx

BioZapper v2.1 Ready to start

Running Sweep F:xxxxxxx t:xxx

Stopped by timer

Stopped by User

Page 5 of 6

Bio Zapper v2.1


http://www.ekovortex.com/

3. Explanations Duty Circle With duty circle (DC) you can adjust what percentage of output signal will be above 0.25V. When DC is 10% average voltage on output is: 1.2V When DC is 50% average voltage on output is: 6 V When DC is 90% average voltage on output is: 10.8 V Average voltage is voltage that you will get if you measure output voltage with voltmeter. According to some people with highest DC you can increase zapping efficiency. Original DC on Dr. Hulda Clark zappers is 50% Formula: for calculating average output voltage is: 12 x (DC/100) More informations you can get from http://en.wikipedia.org/wiki/Duty_cycle Sweep function With sweep function you can run frequencies in some range. For example if you want to run frequencies from 29000 to 31000 Hz, then you need to do following: 1. Set middle frequency to 30000 Hz 2. Set time let say to 7 minutes 3. Set sweep to 1000 Hz 4. Start zapping Frequency increase is calculated: f_inc = sweep x 2 / time f_inc = 1000 x 2 / 7 = 286 Hz Start frequency is calculated: f_start = middle frequency sweep + (f_inc / 2) f_start = 30000 1000 + (386/2) = 29000 + 143 = 29143 Hz Stop frequency is calculated: f_end = f_start + (f_inc x (time 1)) f_end = 29143 + (286 x (time 1)) = 29143 + (286 x 6) = 30859 Hz Bio zapper will produce frequencies from 29143 to 30859 Hz on next way: 1 minute: 29143 Hz = 30000 10000 + (386/2) 1 minute: 29429 Hz = (29143 + 286) 1 minute: 29715 Hz = (29429 + 286) 1 minute: 30001 Hz = (29715 + 286) 1 minute: 30287 Hz = (30001 + 286) 1 minute: 30573 Hz = (30287 + 286) 1 minute: 30859 Hz = (30573 + 286)

Page 6 of 6