Você está na página 1de 4

Electromechanical Fuel Shutoff Valves

M25 and M50 Series

MV-94134B Revised 07-99 Catalog Section 55


(00-02-0124)

Model M5081

Instant Response to Shut Off Signal Positive Valve Closure Vents Gases Trapped After Shutdown Explosion-proof Models Available Models Available for Magneto, CD Ignition or 12/24 VDC Normally Energized Model Available
Options and Accessories
Diode Package (65010065) The Murphy 202 V diode package is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems. Sold separately (see How to Order). Magnetic Switch Adapter As ignition systems wear from usage their power output becomes less and less. Ignition may not have the capacity to reliably trip the fuel valve. Therefore, the use of a Magnetic Switch Adapter for CD ignition systems is recommended. The adapter stores energy from the CD ignition to trip the fuel valve. Three models are available: 65020126: For Negative Ground CD Ignitions up to 240 VDC 65020127: For Positive Ground CD Ignitions up to 450 VDC 65020155: For Negative Ground CD Ignitions 240 VDC to 450 VDC

Description
These fuel shutoff valves are semi-automatic devices for shutdown of natural gas fueled engines. The valve is opened manually and closes when the electromagnet is energized and trips the latch. The valve can be closed manually by turning the valves disconnect knob. A normally energized model is available that holds the valve open electrically and closes when the coil is de-energized. A vent in the valve body relieves trapped gas when the valve closes. A pop-out indicator button informs you when the valve is open or closed. The valves tripping power is provided by an engine ignition system or battery. Models are available for magneto, CD ignition or 12/24 V battery. The M2582 is a 1 inch (25 mm) valve with 1 NPT connections. It has one SPDT snap-switch. The valve body is made of sandcast aluminum. It does not include the open/close indicator button. M5081 is a 2 inch (51 mm) valve with 2 NPT connections. It has two SPDT snap-switches. The valve body is available in sandcast aluminum or cast steel (optional). M5081FS is the same as the M5081 but has a normally energized circuit. This circuit allows the valve to be held open electrically and close by interruption of the coils power circuit. A manual trip knob is not available on this model. An optional 2 in. (51 mm) steel flange pipe connection is available for M5081 and M5081FS steel body models (see Dimensions page 3).

Specifications
Valve Body: Sandcast aluminum, painted red (corrosion resistance). Optional cast steel available for M5081 and M5081FS models only. Valve Seat: Buna-N Maximum Pressure Rating: M2582: 80 psig (552 kPa) [5.52 bar] M5081: 100 psig (689 kPa) [6.89 bar] M5081FS: 100 psig (689 kPa) [6.89 bar] Coil Rating: Intermittent duty; coil type must match power source; CD ignition coil resistance: 72 CD primary voltage: 1.38 to 3.8 A M5081FS model: Energized to run (continuous-duty coil) coil resistance: 12 Volt model: 33 (0.36 A) 24 Volt model: 136 (0.17 A) Magneto ignition coil resistance: 0.5 Magneto primary voltage: 1 to 5 A Battery coil resistance : 7 12 or 24 VDC: 1.2 to 2.4 A Wiring (See Internal Wiring page 2): M2582: Wire leads M5081 and M5081FS: Terminal blocks Snap-switch Rating: 5 A @ 480 VAC Laboratory Approval: CSA listed for Class I, Groups C and D Hazardous Locations. 5 amps maximum; intermittent duty; models M5081 and M5081-CD engine ignition powered, and model M5081-B, 12 or 24 VAC or VDC; switch contacts rated 5 A @ 480 VAC maximum.

Warranty
A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Flow Rates
M2582
9.0 [228.6]

Internal Wiring
M2582

Inches water column (p) drop across valve. Millimeters water column in brackets [ ].

8.0 [203.2] 7.0 [177.8] 6.0 [152.4] 5.0 [127.0] 4.0 [101.6] 3.0 [76.2] 2.0 [50.8] 1.0 [25.4]

4 oz . (0. 11 k g.) 10 o 5 ps z. (0 ig (3 .28 k 4 kP g.) 10 p a) [ 0.34 sig (69 bar] kPa ) [0 20 .69 psi bar g (1 ] 38 kPa ) 30 [1. 38 psi bar g (2 ] 07 kPa ) [2 .07 bar ]

10.0 [254.0]

Optional Resistor (See Note) White Black

Red

Ground

250 500 750 1000 1250 1500 1750 2000 2250 2500 2750 3000 [7.08] [14.16] [21.24] [28.32] [35.40] [42.48] [4956] [56.64] [63.72] [70.80] [77.88] [84.96]

NOTE: For grounding the ignition (CD models only) through the fuel valves internal snap-switch, a Murphy Magnetic Switch adapter (see page 4) must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve).

Standard cubic feet per hour. Cubic meters per hour in brackets [ ].

M5081 and M5081FS


Inches water column (p) drop across valve. Millimeters water column in brackets [ ].

M5081 and M5081FS


M5081
10 oz 4o . (. z. 28 (.1 kg 1k .) g.)
Valve Coil Disconnect Switches Ignition 1 Ignition 2

M5081FS
Switch 2 Valve Coil (see Note) Switch 1

3.0 [76.2]

Ground

Ground

2.0 [50.8]

1.0 [25.4]

] bar [.69 ) a kP bar] (69 sig [1.38 10 p 38 kPa) 1 ] 7 bar sig ( ) [2.0 20 p 7 kPa 0 2 ( ig 30 ps
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 [14.16] [28.32] [42.48] [56.64] [70.80] [84.96] [99.12] [113.28] [127.44] [141.60]

10 9
Jumper

8 7 6

5
Jumper

3 2 1

10 9

8 7 6

3 2 1

Optional Resistor (See Note)

Standard cubic feet per hour. Cubic meters per hour in brackets [ ].

NOTE: For grounding the ignition (CD models only) through the fuel valves internal snap-switch, a Murphy Magnetic Switch adapter (see page 4) must be used in addition to a 100 ohm, 2 watt resistor (supplied with valve).

MV-94134B page 2 of 4

Dimensions

M2582
Latching Handle latches valve open Manual Disconnect knob trips valve 1/2 NPT Conduit Connection

Steel Flanged Option 3


(available on M5081 and M5081FS steel body configurations only)
3-5/8 in. (92 mm) diameter

1 NPT (2 places)

45

1/4 NPT Vent and Plug 3-3/32 in. (79 mm) 5-1/2 in. (140 mm)

7-5/16 in. (186 mm) 3/4 in. (19 mm) dia. (4 places) each end equally spaced on a 4-3/4 in. (121 mm) b.c. (bolt circle)

14-25/64 to 14-29/64 in. (366/367 mm)

2 in. (51 mm) dia. 2 places 150# RF (raised face) pipe flange

M5081 and M5081FS

Manual Disconnect knob trips valve Latching Handle (M5081 only) latches valve open 1/2 NPT Conduit Inlet Breather

1/2 NPT Conduit Connection (2 plcs.)

1-3/8 in. (35 mm)

10-5/16 in. (262 mm) 3-7/16 in. (87 mm)

Valve Open/Close Indicator Button

Vent and Plug 1/2 NPT 9-3/8 in. (238 mm)

2 NPT (2 places) 3 in. (76 mm) 7-3/4 in. (197 mm)

4-1/16 in. (103 mm)

MV-94134B page 3 of 4

How to Order
To order your valve, use the diagram below to specify your model and options. Example: M5081-A-2

Accessories
Specify part number when ordering. Magnetic Switch Adapter
65020126: For Negative Ground CD Ignitions up to 240 VDC 65020127: For Positive Ground CD Ignitions up to 450 VDC 65020155: For Negative Ground CD Ignitions 240 VDC to 450 VDC

_____ __ __
Base Models M2582 M5081 M5081FS Body Material Blank = Aluminum 2 = Steel (M5081 and M5081FS only) 3 = Steel body with steel flange mounting (M5081 and M5081FS only)

Trip Coil A = Magneto ignition B = Battery C = CD ignition Coil for M5081FS model only A = 12 VDC B = 24 VDC

Diode Package
65010065: For use with dual Magneto Ignition systems.

Shipping Information
Shipping Weights:
M2582: 5 lbs 8 oz. (2.49 kg) M5081: 14 lbs 8 oz. (6.58 kg) M5081-2: 40 lbs (18.14 kg) M5081-3: 56 lbs (25.40 kg) M5081FS: 14 lbs 8 oz. (6.58 kg) M5081FS-2: 40 lbs (18.14 kg) M5081FS-3: 56 lbs (25.40 kg)

Service Parts
Specify part number when ordering.
M2582
Coil Assembly Battery CD Ignition Magneto Ignition FS Coil Assembly 12 VDC 24 VDC Latch Block Assembly Latch block assembly Latch block switch and coil assembly Latch block switch and mounting bracket assembly Handle and Latch Kit Handle and latch kit Handle kit Manual DIsconnect Assembly Snap-switch Assembly Close/Open Indicator Assembly Stem and Seat Kit Top Works Complete Valve Less Body and Vent Vent Bushing Assembly Diaphragm Assembly Pilot Diaphragm Diode Package for Dual Magneto Ignitions Magnetic Switch Adapter for CD Ignitions Single/Dual ign. negative ground up to 240 VDC Single/Dual ign. positive ground up to 450 VDC Single/Dual ign. negative ground up to 450 VDC 65020126 65020127 65020155 65020126 65020127 65020155 55000093 55000146 55000143 55000095 55000144 55000074 55000118 55000102 55000096 55000097 55000098 55000137 55000072 5500-0138 55000075 55000131 55000132 55000160 55000138 55000135
55000161 (12V) 55000194 (24V)

M5081
55000126 55000127 55000080

M5081FS

55000128 55000129 55000094

55000158 55000159

Shipping Dimensions:
M2582: 8 x 8 x 7 in. (203 x 203 x 178 mm) M5081: 12 x 12 x 9-5/16 in. (305 x 305 x 237 mm) M5081-2: 12 x 12 x 9-5/16 in. (305 x 305 x 237 mm) M5081-3: 18 x 12 x 13-1/2 in. (457 x 305 x 343 mm) M5081FS: 12 x 12 x 9-5/16 in. (305 x 305 x 237 mm) M5081FS-2: 12 x 12 x 9-5/16 in. (305 x 305 x 237 mm) M5081FS-3: 18 x 12 x 13-1/2 in. (457 x 305 x 343 mm)

55000102

55000132

65010065

FW MURPHY

CONTROL SYSTEMS & SERVICES DIVISION

COMPUTRONIC CONTROLS, LTD

P.O. Box 470248 Tulsa, Oklahoma 74147 USA +1 918 317 4100 Fax: +1 918 317 4266 E-mail: sales@fwmurphy.com
INDUSTRIAL PANEL DIVISION

P.O. Box 1819 Rosenberg, Texas 77471 USA Phone: +1 281 633 4500 Fax: +1 281 633 4588 E-mail: sales@fwmurphy.com
FRANK W. MURPHY, LTD

41 - 43 Railway Terrace Nechells Birmingham B7 5NG UK Phone: +44 121 327 8500 Fax: +44 121 327 8501 E-mail: info@computroniccontrols.com Web site: www.computroniccontrols.com
FW MURPHY INSTRUMENTS (HANGZHOU) CO. LTD

Fax: +1 918 317 4124 E-mail: ipdsales@fwmurphy.com


MURPHY POWER IGNITION

Web site: www.murphy-pi.com

Church Rd Laverstock Salisbury SP1 1QZ UK Phone: +44 172 241 0055 Fax: +44 172 241 0088 E-mail: sales@fwmurphy.co.uk Web site: www.fwmurphy.co.uk

77 23rd Street Hangzhou Economic & Technological Development Area Hangzhou, Zhejiang 310018 China Phone: +86 571 8788 6060 Fax: +86 571 8684 8878
Printed in U.S.A.

www. fwmurphy .com MV-94134B page 4 of 4