Você está na página 1de 12

Release Notes

November 2012

Analyzer Update

1 In this version
This release contains support for new and updated file formats. There are updates for most technologies that Actix supports, with changes falling under the following categories:

New collection device support: Added support for the Hisilicon chipset in TEMS file format. Added support for Nokia 6720 device in TEMS file format. Added support for Agilent 1.925 GHz scanner. Added support for PCTEL EX V2 UMTS scanner in Ding Li file format. Added support for the DaTang8142 device in Ding Li file format. Added support for LTE TDD PCTel scanner in Ding Li file format.

Application layer improvements: Added a new Spotlight analysis for LTE inter-technology (GSM and UMTS) neighbour list.

Platform improvements: A problem with the Text Import feature preventing all rows from being imported has been corrected. A problem with the Delta Plot feature has been corrected.

Actix Analyzer Update

October 2012

2 New collection device or technology support


2.1 Agilent AOD support

[Case 71062] Added support for Iperf data testing. [Case 70966] Added support for Agilent 1.925 GHz scanner.

2.2 Ascom TEMS support

Added support for the Hisilicon chipset. [Case 70882] A problem has been resolved that caused Analyzer to crash while loading TEMS logfiles with UnspecifiedQualcommDiagnosticsResponse message inside. [Case 49638] Added support for Nokia 6720 handset.

2.3 Couei support

[Case 68755, 68657] Hysteresis attribute has been added for LTE. [Case 68657] A3-Offset attribute value calculation has been fixed.

2.4 Ding Li support

[Case 70348] Added support for PCTEL EX V2 UMTS scanner in Ding Li file format. [Case 70717] Added support for the DaTang8142 device in Ding Li file format. Added support for LTE TDD PCTel scanner in Ding Li file format. HSPA attributes decoding have been improved for Ding Li file format. CQI max and average attributes have been added.

2.5 Ericsson CT support

NAS Security Mode and Authentication events have been added. Support of new fields and messages has been added for V7 logfiles.

Actix Analyzer Update

October 2012

2.6 Huawei CT support

GEO Location for start of the call event has been improved. RSRP and RSRQ attributes for SectorHandle have been added.

2.7 KnowYou support

[Case 62938] Added support for the Mark Info for indoor drivetests.

2.8 Nemo support

[Case 68591] An issue with corrupted Stream Name has been fixed. [Case 70963] An issue has been fixed that made Analyzer show wrong measurements on Ant port 0. [Case 69816] LTE_UE_Power_Tx attribute for Qualcomm chipset has been added. [Case 70399] A problem has been resolved that caused Analyzer to crash while working with Nemo indoor files with corrupted latitude/longitude information. [Case 63941] An issue has been solved that made Analyzer incorrectly calculate MOS_LQO_DL and MOS_LQO_UL attributes. [Case 49730] A problem has been resolved that caused Analyzer to crash while loading Nemo 6.1 and 6.3 logfiles.

2.9 Qualcomm support

[Case 70161] Attribute LTE_UE_OutOfSync_UL has been added.

2.10 Rohde & Schwarz support

[Case 1515] Following attributes are now separated by each EARFCN Bandwidth EARFCN RSRP RSRQ

Actix Analyzer Update

October 2012

2.11 Swissqual support

[Case 68075] Following attributes support have been added: Uu_RLC_DL_AM_PDU_Error_Percentage Uu_RLC_UL_AM_PDU_ReTX_Percentage LLC_UL_retransmissions LLC_DL_retransmissions LTE_UE_RLC_NumNACKs_UL LTE_UE_RLC_ReTxPDUs_UL_RB

[Case 71222] An issue has been solved that made Analyzer set call drops as a normal event in the case of a following cell update procedure. [Case 69962] An issue has been solved that made Analyzer calculate the App_Tput_DL_Mean_HTTP attribute incorrectly. [Case 69077] Support of Virtual Active Set measurements has been added. The following attributes have been added: Uu_VirtualActiveSet_Count Uu_VirtualActiveSet_EcNo Uu_VirtualActiveSet_SC Uu_VirtualActiveSet_RSCP

2.12 Verizon DataPro support

[Case 49706] An issue have been solved that made Analyzer to show incorrect RSRP and RSRQ values.

2.13 Wider Networks support

[Case 69609] Support for GSM v1.2 and UMTS v1.2 logfiles have been added.

2.14 ZK Celltest

[Case 67428] Where the new indoor feature from the October release is being used, dummy GPS coordinates from the log file will now be ignored.

2.15 Generic

16 bit Cell Identity support has been added for all file formats. [Case 70895] An improvement has been made in order to set the EDPDCH-MaxChannelisationCodes attribute for releases 7 and 8.

Actix Analyzer Update

October 2012

3 Application layer improvements


3.1 Generic

Some attribute spelling mistakes have been corrected.

3.2 Spotlight

A new Spotlight LTE KPI 4G 3G/2G Missing Neighbor Analysis has been implemented in order to help building the GSM and UMTS neighbour list of the LTE cells in a network. At every location bin, Spotlight determines the best sector for each EARFCN from either LTE scanner or handset data (LTE handset data is only used if no LTE scanner data is available). If the strongest LTE sector is weaker than a threshold, Spotlight uses the GSM and UMTS scanner data to determine what neighbours should be added, retained or removed from the intertechnology neighbour list.

Actix Analyzer Update

October 2012

The following parameters can be configured: LTE coverage criteria applied on each bin: it may not be required to look for possible inter-technology neighbours in places where LTE coverage is good. GSM and UMTS coverage criteria: a cell is not a suitable intertechnology neighbor for an LTE cell if its signal is too weak, if it is too far from the LTE cell, or if it is seen only rarely as a possible neighbour. The maximum number of GSM and UMTS neighbours that can be defined for the LTE cells is also configurable.

[Case 66837] The Missing Neighbours tab has been improved in order to be populated with correct results for all known logfiles.

Actix Analyzer Update

October 2012

4 Platform improvements
4.1 Analyzer

[Case 69635] A problem with the Text Import feature preventing all rows from being imported has been corrected. [Case 69767, 14733] A problem with the Delta Plot feature has been corrected.

Actix Analyzer Update

October 2012

5 Documentation

None

Actix Analyzer Update

October 2012

6 Known Issues / Obsolescence

None

Actix Analyzer Update

October 2012

10

Previous Release Notes


You can find release notes for earlier Analyzer updates in the folder below this one, Individual Notes.

Actix Analyzer Update

October 2012

11

US:

T +1 703 707 4777 F +1 703 707 4778 T +86 21 5396 0670 F +86 21 5396 0676 T +49 351 40429 0 F +49 351 40429-50 T +852 2295 6677 F +852 2295 6687 T +91 11 41683064 F +91 11 41683080 T +81 (3)6860 8262 F +81 (3)6860 8201 T +65 6333 7428 F +65 6333 5540 T +46 42 38 99 00 F +46 42 21 05 85 T +44 (0)20 8735 6300 F +44 (0)20 8735 6301

CN:

DE:

HK:

IN:

JP:

SG:

SE:

UK:

Você também pode gostar