Technical Manual
A42022-L5969-G51-1-7618
1 (150)
Technical Manual
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given as is and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright Nokia Siemens Networks 2007. All rights reserved.
2 (150)
Technical Manual
Statements of compliance
CE statement
The CE conformity declaration for the product is fulfilled when the system is built and cabled in line with the information given in the manual and the documentation specified within it, such as installation instructions, cable lists or the like. Where necessary project-specific documentation should be taken into consideration. Deviations from the specifications or independent modifications to the layout, such as use of cable types with lower screening values for example, can lead to violation of the CE protection requirements. In such cases the conformity declaration is invalidated. The responsibility for any problems which subsequently arise rests with the party responsible for deviating from the installation specifications.
3 (150)
Technical Manual
Contents
1 1.1 1.2 1.3 1.3.1 1.3.2 1.3.3 1.4 1.5 2 2.1 2.1.1 2.1.2 2.1.3 3 4 4.1 4.2 4.3 4.3.1 4.3.2 4.3.3 4.4 4.4.1 4.4.2 4.4.3 4.4.4 5 5.1 5.2 5.2.1 5.2.2 5.2.3 5.3 5.4 5.4.1 5.4.2 5.4.3 5.4.4 5.5 5.6 Notes on this Documentation............................................................... 9 Customer Documentation........................................................................ 9 Complementary Documents .................................................................. 10 Symbols Used in the Customer Documentation.................................... 10 Symbol for Warnings ............................................................................. 10 Symbols for Notes ................................................................................. 10 Symbols for Menu Displays and Text Inputs ......................................... 11 Notes on Licensed Software.................................................................. 11 Standard Compliance ............................................................................ 11 Introduction.......................................................................................... 13 Application Types .................................................................................. 14 Terminal Multiplexer Type ..................................................................... 14 Add/Drop Multiplexer Type .................................................................... 15 Local Cross-Connection Type ............................................................... 16 Overview of the Main Features........................................................... 17 Network Applications.......................................................................... 20 Terminal-to-Terminal Topologies........................................................... 20 Linear Topologies with Add/Drop Function............................................ 21 Ring Network Functionality.................................................................... 22 Single Ring ............................................................................................ 22 Dual Ring Interworking .......................................................................... 23 Multiple Ring Closure ............................................................................ 24 Data Service Applications...................................................................... 25 Ethernet Private Line ............................................................................. 26 Ethernet Virtual Private Line.................................................................. 26 Ethernet Private LAN............................................................................. 27 Ethernet Virtual Private LAN.................................................................. 29 System Description ............................................................................. 32 Subrack ................................................................................................. 32 Basic Functions ..................................................................................... 34 User Data Interfaces.............................................................................. 35 Switch Fabric Functions ........................................................................ 35 Multiplex and Mapping Functions .......................................................... 36 Ethernet Transparent or Layer 2 Functions........................................... 39 Clock Pulse Supply, Synchronization .................................................... 40 Available Timing Sources ...................................................................... 40 T0 System Clock ................................................................................... 41 Timing Output Interface ......................................................................... 42 Real Time Clock .................................................................................... 42 Retiming ................................................................................................ 42 Laser Safety Shut-down ........................................................................ 42
4 (150)
Technical Manual
5.7 5.8 5.9 5.10 5.10.1 5.10.2 5.11 5.12 5.12.1 5.12.2 5.12.3 5.12.4 6 6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.8.1 6.8.2 6.8.3 6.8.4 6.9 6.10 6.11 6.12 6.13 6.14 6.15 6.16 6.17 6.18 6.19 6.20 7 7.1 7.1.1
External Alarm Interfaces .......................................................................43 Engineering Order Wire..........................................................................43 Software/Firmware .................................................................................44 Protection Architecture ...........................................................................44 Traffic Protection ....................................................................................45 Equipment Protection .............................................................................46 Operating Terminal TNMS-M SURPASS hiT 7060 LCT ........................47 Connection to Network Management Systems ......................................47 SURPASS NE connect to TNMS ...........................................................47 SMA NE connect to TNMS.....................................................................48 Third-party DCC transparency ...............................................................49 Embedded Control Channel Applications...............................................50 Components of SURPASS hiT 7060 ...................................................52 Subrack and Slot Arrangement ..............................................................53 List of Cards Supported..........................................................................59 Power Supply Card: PWR ......................................................................61 Fan Tray .................................................................................................62 Air Filter ..................................................................................................62 System Controller Card: SC ...................................................................63 System Management Interface Panel ....................................................64 Cross-connection and Timing Card with one STM-16/4 optical interface: CCS16 ....................................................................................67 Cross-connection Architecture and Capacity .........................................68 Timing Function......................................................................................69 1 STM-16/4 Optical Interface ..............................................................69 Faceplate and LEDs...............................................................................71 Optical STM-16 Interface Card: 1 STM-16..........................................71 Optical/Electrical STM-4/1 Interface Card: 4 STM-4/STM-1 ...............74 Optical/Electrical STM-1 Interface Card: 2 STM-1 ..............................76 Electrical 155 Mbps Interface Card: 4 STM-1E (W/P), 4 STM-1EW (W/P), 4 STM-1E EC .........................................................77 Electrical 34/45 Mbps Interface Card: 3 E3/DS3 (W/P), 3 E3/DS3 EC .............................................................................................81 Electrical 2 Mbps Interface Card: 63 E1/R (W/P), 63 E1/R EC ..........................................................................................................85 Gigabit Ethernet and Fast Ethernet Interface Card: 2 GE + 8 FE/AE .....................................................................................................88 Gigabit Ethernet and Fast Ethernet Interface Card: 2 GE + 8 FE RPRE................................................................................................92 Gigabit Ethernet Interface Card: 2 GE/T .............................................96 Fast Ethernet Interface Card: 8 FE/T ..................................................99 Fast Ethernet Interface Card: 6 FE/L2 ..............................................101 Optical Amplifier Card: OA ...................................................................104 System Control and Monitoring........................................................108 Indicating and Operating Elements of the NE ......................................110 Operating Devices of SURPASS hiT 7060...........................................110
5 (150)
Technical Manual
7.1.2 7.2 7.2.1 7.2.2 7.3 7.4 7.4.1 7.4.2 7.4.3 7.4.4 7.4.5 7.5 8 8.1 8.2 9 9.1 9.1.1 9.1.2 9.1.3 9.1.4 9.1.5 9.1.6 9.1.7 9.1.8 9.1.9 9.1.10 9.1.11 9.2 9.3 9.3.1 9.3.2 9.3.3 9.3.4 9.4 9.4.1 9.4.2 9.5 9.5.1 9.5.2 9.5.3 9.6 9.7 9.7.1 9.7.2
Operating and Display Elements of the Cards .................................... 110 Control and Monitoring by TNMS-M Network Management System................................................................................................. 110 TNMS-M SURPASS hiT 7060 LCT ..................................................... 111 TNMS-M .............................................................................................. 112 Management System Protection ......................................................... 113 NE Software ........................................................................................ 114 Application Management Module ........................................................ 115 Hardware Driver Modules.................................................................... 116 Real-Time Multi-Task Operation System............................................. 116 SNMP Agent........................................................................................ 117 MIB Management Module ................................................................... 117 Management Protocols and DCC........................................................ 117 Commissioning and Maintenance ................................................... 119 Commissioning .................................................................................... 119 Maintenance ........................................................................................ 119 Technical Data ................................................................................... 120 Traffic Interfaces.................................................................................. 120 Optical STM-16 Interface..................................................................... 120 Optical STM-4 Interface....................................................................... 126 Optical STM-1 Interface....................................................................... 127 Electrical 155 Mbps Interface .............................................................. 128 Electrical 45 Mbps Interface ................................................................ 128 Electrical 34 Mbps Interface ................................................................ 129 Electrical 2 Mbps Interface .................................................................. 129 Gigabit Ethernet Interface, Optical ...................................................... 130 Fast Ethernet Interface 100 Base-T, Electrical.................................... 131 Electrical Ethernet Interface 10 Base-T............................................... 132 OA Interface ........................................................................................ 132 Control Interface .................................................................................. 136 Signalling Interface .............................................................................. 136 Fault Indication and Services Status LEDs ......................................... 136 Alarm Contacts .................................................................................... 137 MDI/MDO Interfaces for Customer-specific Channels......................... 137 EOW Interface ..................................................................................... 137 Interfaces for Network Clock Synchronization..................................... 138 2048 Kbps Interface ............................................................................ 138 2048 KHz Interface.............................................................................. 139 Switching and Delay Times ................................................................. 139 MS-SPRing Protection Switching ........................................................ 139 MSP Line Protection Switching ........................................................... 140 SNC/I and SNC/N Path Protection Switching...................................... 140 Power Supply ...................................................................................... 140 Environmental Conditions.................................................................... 142 Climatic Conditions.............................................................................. 142 ElectroMgnetic Compatibility ............................................................... 142
6 (150)
Technical Manual
9.8 9.9
7 (150)
Summary of changes
Summary of changes
Issue 1 Issue date October 2007 Remarks Initial version
8 (150)
1
1.1
Customer Documentation
The Customer Documentation of SURPASS hiT 7060 comprises the following descriptions and manuals: Technical Manual (TED) The Technical Manual gives an overview of the application, performance features, interfaces and functions of SURPASS hiT 7060. It also contains the most important technical data.
Note The Technical Manual does not contain any instructions to be carried out. Installation and Test Manual (ITMN) The Installation and Test Manual contains instructions on mounting, connecting, and commissioning SURPASS hiT 7060, and connecting and commissioning the Local Craft Terminal (LCT) operating terminals. Troubleshooting Manual (TSMN) The Troubleshooting Manual provides information about the alarm list SURPASS hiT 7060 supports and troubleshooting procedures. LCT User Manual The LCT User Manual provides information about the LCT (features, configuration, installation, etc.) and how to operate, monitor and maintain SURPASS hiT 7060 using the element manager software (application software) running on the LCT.
9 (150)
Note Besides the LCT User Manual, the Online Help of the SURPASS hiT 7060 software is of high importance for the operator.
1.2
Complementary Documents
In addition to the SURPASS hiT 7060 customer documentation listed in Chapter 1.1, there is further documentation:
This document identifies the specific version of SURPASS hiT 7060 and provides information on hardware, software, LCT components and the limitations of the release as well as important notes concerning the customer documentation.
1.3
1.3.1
This symbol identifies notes which, if ignored, can result in personal injury or in permanent damage to the equipment.
1.3.2
Note Information which extends beyond the immediate context. Cross reference to other chapters in this manual or reference to other manuals. Reference to the online help system of the element manager software.
Help
10 (150)
1.3.3
1.4
1.5
Standard Compliance
SURPASS hiT 7060 is in compliance with the following standards (as applicable): Electronic Industry Association (EIA) European Telecommunications Standards Institute (ETSI) Institute of Electrical and Electronics Engineers (IEEE)
Virtual Local Area Networks (VLAN) Traffic Class Expediting and Dynamic Multicast Filtering CSMA/CD Access Method
G.703 Physical/Electrical Characteristics of Hierarchical Digital Interfaces G.7041/Y1303 Generic Framing Procedure (GFP) G.7042/Y1305 Link Capacity Adjustment Scheme (LCAS) for Virtual Concatenated Signals G.707/Y1322 Network Node Interface (NNI) for the Synchronous Digital Hierarchy (SDH) G.774 View SDH Management Information Model for Network Element (NE)
11 (150)
Synchronization Layer Functions Characteristics of SDH Equipment Functional Blocks SDH Management SDH Transport Network Architecture Timing Characteristics of SDH Equipment Slave Clocks (SEC)
G.823 Control Of Jitter and Wander within Digital Networks which are Based On The 2048 Kbps Hierarchy G.825 The Control of Jitter and Wander Within Digital Networks which are based on SDH G.826 Error Performance Parameters and Objectives For International, Constant Bit Rate Digital Paths At Or Above The Primary Rate G.828 Error Performance Parameters and Objectives For International, Constant Bit Rate Synchronous Digital Paths G.829 Error Performance Events for SDH Multiplex and Regenerator Sections G.831 SDH Management Capabilities Of Transport Networks Based on
G.841 Types and Characteristics of SDH Network Protection Architectures G.842 G.957 Interworking of SDH Network Protection Architecture Optical Interfaces for Equipment and System Relating to SDH
G.958 Digital Line Systems Based on SDH for Use on Optical Fibre Cables G.691 Optical Interfaces for Single-Channel STM-64, STM-256, and Other SDH Systems with Optical Amplifiers G.664 Optical Safety Procedures and Requirements for Optical Transport System M.3010 Principles for a Telecommunications Management Network (TMN) M.3300 TMN F Interface Requirements
12 (150)
Introduction
Introduction
SURPASS hiT 7060 is a multi-service provisioning platform with add/drop, terminal and Cross-Connection (CC) functionality for universal installation at all network levels. All applications can be implemented using one main shelf with four extension shelves. Reconfiguration during operation is possible. SURPASS hiT 7060 transports data signals and standard voice based traffic over one single platform. For transporting data in the most economic way, the SURPASS hiT 70xx product line combines technologies such as GFP, LCAS and Resilient Packet Ring (RPR) with the reliability and robustness of SDH networks and a Quality of Service (QoS). SURPASS hiT 7060 provides full cross-connectivity between all interfaces. The capacity of the switching fabric is up to 160 x 160 VC-4 + 4032 x 4032 VC-12 equivalents. This applies to the VC-4, VC-3 and VC-12 layer and to all CC types (unidirectional, bidirectional and broadcast). SURPASS hiT 7060 can be used as:
in multi-service transport and aggregation/switching network applications. State-of-the-art protection switching mechanism is supported to enable an optimum network with very highest reliability possible - depending on the relevant network topology and the requirements of the network operator (see Chapter 5.10). One single SURPASS hiT 7060 main shelf supports up to four SURPASS hiT 7035 Extension Shelves which make it possible to support 1197 2 Mbps interfaces simultaneously add/drop in one platform.
Note For detailed information about the SURPASS hiT 7060 features, please refer to Chapter 3.
13 (150)
Introduction
2.1
Application Types
In Chapter 2.1.1 to 2.1.3, an overview on usage of SURPASS hiT 7060 is provided.
2.1.1
hiT 7060 155 Mbps (STM-1)/ 622 Mbps (STM-4)/ 2.5 Gbps (STM-16)
2 Mbps (PDH) 34/45 Mbps (PDH) 155 Mbps (Electrical) 155 Mbps (STM-1, Opt.) 622 Mbps (STM-4, Opt.) 2.5 Gbps (STM-16, Opt.) Fast Ethernet Gigabit Ethernet
Fig. 2.1
TMX Type
The TMX type (see Fig. 2.1) is equipped with a switching network thus provides cross-connectivity between all available line and tributary interfaces on VC-4, VC-3 and VC-12 levels as well as Ethernet interfaces. The capacity of the High Order (HO) switching network is 160 x 160 VC-4s and the capacity of the Low Order (LO) switching network is 4032 x 4032 VC12s. SURPASS hiT 7060 supports multiple line interfaces for star topology:
14 (150)
Introduction
Simultaneously support 4 STM-16 and 24 STM-1 line interfaces Simultaneously support 2 STM-16 and 8 STM-4 line interfaces as well as 24 STM-1 line interfaces Simultaneously support 2 STM-16 and 32 STM-1 line interfaces Simultaneously support 10 STM-4 and 24 STM-1 line interfaces Simultaneously support 1197 2 Mbps interfaces
2.1.2
West
East
hiT 7060
2 Mbps (PDH) 34/45 Mbps (PDH) 155 Mbps (Electrical) 155 Mbps (STM-1, Opt.) 622 Mbps (STM-4, Opt.) 2.5 Gbps (STM-16, Opt.) Fast Ethernet Gigabit Ethernet
Fig. 2.2
ADM Type
The ADM type (see Fig. 2.2) is equipped with a switching network and provides cross-connectivity between all line and tributary interfaces on VC-4, VC-3 and VC-12 levels as well as Ethernet interfaces. SURPASS hiT 7060 supports multiple ring terminations on a signal NE.
15 (150)
Introduction
2.1.3
SURPASS hiT 7060 can be used as LXC type (see Fig. 2.3).
hiT 7060
2 Mbps (PDH) 34/45 Mbps (PDH) 155 Mbps (Electrical) 155 Mbps (STM-1, Opt.) 622 Mbps (STM-4, Opt.) 2.5 Gbps (STM-16, Opt.) Fast Ethernet Gigabit Ethernet
Fig. 2.3
LXC Type
The LXC type provides full cross-connectivity for line-to-line, line-to-tributary and tributary-to-tributary connections. The capacity of the HO switching network is 160 160 VC-4s and the capacity of the LO switching network is 4032 4032 VC-12s. This is valid for the VC-4, VC-3 and VC-12 layers and all CC types (unidirectional, bi-directional and broadcast).
16 (150)
Subrack Type
Double-row subrack with 1 System Controller (SC) slot, 2 CC slots, 1 System Management Interface Panel, 2 power slots, 1 fan tray, 1 air filter, 6 I/O slots and 11 traffic slots Fully non-blocking switching fabric 25 Gbps switching capacity with VC-4 granularity and 10 Gbps switching capacity with VC-12 granularity STM-16 optical interfaces STM-4 optical interfaces STM-1 optical interfaces STM-1 electrical interfaces 34/45 Mbps electrical interfaces 2 Mbps electrical interfaces 1000 Base-X optical interfaces 10/100 Base-Tx electrical interfaces Optical Amplifier (OA) interfaces GFP Virtual Concatenation (VCAT) (VC-12, VC-3, VC-4, VC-4-4c and VC-4-16c) LCAS G.813 option 1 internal oscillator STM-N line timing Retiming
Switch Fabric
Interface Types
NE features
17 (150)
Transparent Data Communications Channel (DCC) (MS/RS/MS+RS) Near end performance monitoring Far end performance monitoring Automatic software download Auto link detection Integrated OA cards Traditional Engineering Order Wire (EOW) over E1/E2/F1 Voice Over Internet Protocol (VOIP) EOW over DCC 1 + 1 power unit protection 1 + 1 switch fabric and clock unit protection 1 + 1 hardware protection for STM-1E interfaces 1 + 1 hardware protection for E3/DS3 electrical interfaces 1 : N (N<=2) hardware protection for E1 electrical interfaces Multiplex Section Protection (MSP) (1 + 1) for STM-16/4/1/1E SNCP/I and SNCP/N for VC-12/VC-3/VC-4/VC-4-4c/VC-4-16c 2-fiber and multiple 2-fiber shared ring protection for STM-16/4 Two node Dual Node Interworking (DNI) between two Multiplex Section-Shared Protection Rings (MS-SPRing) (STM-16/4 ring) Transparent Local Area Networks (LAN) transport Jumbo packet supported (9600 bytes) IEEE 802.1q, VLAN double tagging Rapid Spanning Tree Protocol (RSTP) and Multiple Spanning Tree Protocol (MSTP) Flow control and rate limiting function Internet Group Management Protocol (IGMP) snooping Media Access Control (MAC) self learning MAC address aging time configurable Auto-negotiation Resilient Packet Ring (RPR)
Hardware Protection
Traffic Protection
Ethernet Functionality
TNMS-M Embedding
18 (150)
Single element management by TNMS-M SURPASS hiT 7060 LCT Service/network/element management by TNMS-M and TNMS Core
19 (150)
Network Applications
Network Applications
For SDH general logic applications, the NEs can be used in a straightforward way of creating point-to-point connections, linear chain configurations and ring configurations.
Terminal-to-terminal topologies (see Chapter 4.1) Linear topologies with add/drop function (chains) (see Chapter 4.2) Ring network functionality (see Chapter 4.3)
For SDH special applications to provide powerful services, the NEs can be used in a way of transporting data service.
4.1
Terminal-to-Terminal Topologies
Terminal-to-terminal links are supported by SURPASS hiT 7060 NEs in TMX application with the option of 1 + 1 MSP for STM-16/4/1 interfaces. Fig. 4.1 shows a straightforward point to point network with one TMX at the transmitting end and another at the receiving end. It is using MSP protection switching.
20 (150)
Network Applications
Tributary interfaces
Tributary interfaces
Fig. 4.1
Terminal-to-Terminal Link
At the TMX, the client equipment is connected to the TMX through the tributary interfaces (TDM or data traffic). The use of MSP between the NEs is preferred for redundancy reasons but not mandatory.
4.2
21 (150)
Network Applications
STM-1/ STM-4/ STM-16 Working hiT 7060 Line STM-1/ STM-4/ STM-16 Protection hiT 7060
STM-1/ STM-4/ STM-16 Working Line STM-1/ STM-4/ STM-16 Protection hiT 7060
Tributary interfaces
Tributary interfaces
Tributary interfaces
Fig. 4.2
An ADM is normally used at an intermediate site to add/drop client traffic. In Fig. 4.2 an ADM is located between two TMXs. At the ADM, the selected traffic is added/dropped at VC-4, VC-3 or VC-12 levels; while the through traffic is transparently passed through the node. The use of MSP between the adjacent NEs is preferred for redundancy reasons but not mandatory
4.3
4.3.1
Single Ring
The line speeds of the SURPASS hiT 7060 single ring can be STM-16, STM-4 or STM-1.
22 (150)
Network Applications
hiT 7060
hiT 7060
hiT 7060
Fig. 4.3
Single Ring
4.3.2
23 (150)
Network Applications
hiT 7060
hiT 7060
hiT 7060
hiT 7060
hiT 7060
hiT 7060
hiT 7060
hiT 7060
hiT 7060
Fig. 4.4
4.3.3
24 (150)
Network Applications
hit 7060
hit 7060
hit 7060
hit 7060
hit 7060
Fig. 4.5
4.4
Ethernet Private Line (EPL) Ethernet Virtual Private Line (EVPL) Ethernet Private LAN (EPLan) Ethernet Virtual Private LAN (EVPLan)
25 (150)
Network Applications
4.4.1
FE 8 WAN Ports
8 FE/T
hiT 7060
2 GE/T
GE
Fig. 4.6
4.4.2
26 (150)
Network Applications
switching capabilities to provide statistics multiplexing, per VLAN control and Spanning Tree Protocol (STP) function and Ethernet based rate limiting per VLAN or port. The EVPL is useful when creating hub-and-spoke architectures in which multiple remote offices all require access to a headquarter or multiple customers all require access to an Internet Service Providers (ISP) Point Of Presence (POP).
GE
FE
32 WAN ports
VC-4-Xv or VC-12-Xv
2 GE + 8 FE/AE hiT 7060 VC-4-Xv Headquarter VC-12-Xv FE hiT 7060 Remote Office 1 Remote Office 2 hiT 7060 2 GE + 8 FE (Client)
Fig. 4.7
4.4.3
27 (150)
Network Applications
from one customer can be received at one or more of the other customers. Each site (customer) is connected to a multipoint-to-multipoint Ethernet Virtual Concatenation (EVC) and uses dedicated resources so different customers Ethernet frames are not multiplexed together. As new sites (customers) are added, they are connected to the same multipoint EVC, thus simplifying provisioning and service activation. From a subscriber standpoint, an EPLan makes the MSTP network look like a LAN. The EPlan architecture differs from EPL in that rather than use a predefined mapping between VLAN tags and link connections, the operators network equipment, uses Ethernet switching (i.e. Bridge learning) to pass Ethernet frames to the appropriate link. However this makes it difficult to guarantee performance as network Ethernet switching introduces additional latency and probability of increased packet loss. SURPASS hiT 7060 brings multiple Wide Area Networks (WAN) interfaces into L2 switching. Customer service can be delivered through dedicated Virtual Concatenation Groups (VCG) with little latency and little packet loss. The WAN interface can be provisioned individually on TNMS-M.
28 (150)
Network Applications
FE
FE GE 32 WAN ports
hiT 7060
2 GE + 8 FE/AE
2 GE + 8 FE (Client)
FE
FE
2 WAN ports
hiT 7060
6 FE/L2
6 FE (Client) GEFE FE
Fig. 4.8
4.4.4
29 (150)
Network Applications
service delivery technologies providing customer frame encapsulation must be used such as Multi-Protocol Label Switching (MPLS), MAC-in-MAC and RPR. By merging RPR technology with Virtual Container (VC), GFP and MSTP, SURPASS hiT 7060 can add statistical multiplexing and traffic engineering to the VC-enabled MSTP equipment. The 2 GE + 8 FE RPRE card will encapsulate the RPR frames into the GFP frames. The GFP frames are then mapped into a virtual concatenation group VC-4-Xv (X= 1 to 8) which connects the consecutive WANs of these VC-4-Xvs in the MS-SPRing. The RPR will be provisioning over SDH. In RPR, three classes of services (high, medium and low) defined by IEEE 802.17 are transmitted over the ring architecture. RPR has the following features:
Auto-negotiation Flow control Rate limiting Spatial reuse Source weighted fairness Protection
30 (150)
Network Applications
FE .....
GE 2 WAN Ports
FE
GE
hiT 7060
..... FE GE
Fig. 4.9
31 (150)
System Description
5
5.1
System Description
This chapter gives a functional and technical overview of the main features of SURPASS hiT 7060 separated from the physical interfaces. For information about hardware relevant features, please refer to Chapter 6.
Subrack
A picture of SURPASS hiT 7060 subrack is shown in Fig. 5.1. The physical dimensions are 447 mm (wide) 566 mm (high) 329 mm (deep). It is designed to meet ETSI, EIA 300 and Network Equipment Building System (NEBS) requirements. All external interfaces are front access. It is designed for easy maintenance and installation, and supports 600 mm or 19 rack-mount installations. Up to two SURPASS hiT 7060 subracks can be installed into a 2200 mm or 2600 mm high ETSI rack or an EIA 310 19 rack. The space between the two adjacent subracks should be at least 5-rack-unit apart.
32 (150)
System Description
Fig. 5.1
33 (150)
System Description
5.2
Basic Functions
Fig. 5.2 shows the basic functional structure of SURPASS hiT 7060.
System Controller
Timing controller
Maintenance Panel
Tributary interfaces Line interfaces East STM-16/4/1 Interface MS Overhead Process RS Overhead Process
HOCC/LOCC
GFP
STM-1/4/16 Interface
RS OH Process
MS OH Process
Fig. 5.2
On the line side, the send/receive modules (SDH) carry out the conversion to optical/electrical signals. The SDH cards can be equipped with various transceiver modules (SFP modules) in several distance variants up to 2.5 Gbps. On the tributary side, SURPASS hiT 7060 supports various Plesiochronous Digital Hierarchy (PDH), Ethernet and STM-N interfaces. The central element of SURPASS hiT 7060 includes SC, CC, timing controller, and maintenance panel.
34 (150)
System Description
5.2.1
Tab. 5.1
User Interfaces
5.2.2
High Order Cross-Connection (HOCC): 25 Gbps (160 160 VC-4s) Low Order Cross-Connection (LOCC): 10 Gbps (4032 4032 VC-12s)
Cross-Connection All types of cross-connections are possible. The switch fabric is a non-blocking square structured fabric for point-to-point and point-to-multipoint connections. Granularity The configurable and simultaneously usable switching hierarchies of the fabric are VC-4, VC-3 and VC-12. HO and LO VC-n Connectivity The switching fabric allows the following connections:
Unidirectional connections Unidirectional point-to-multipoint (including 1 + 1 SNCP head end) Bidirectional connections
35 (150)
System Description
Broadcasting (HOCC 1 : 4, LOCC 1 : 63) Drop and continue (broadcast 1 to 2 + SNCP tail end) Selector 2 to 1 (protected tail end for 1 + 1 SNCP)
Concatenation Virtual concatenated VC-12, VC-3 and VC-4 signals are supported. Protection switching for virtual concatenated signals VC-4, VC-3 and VC-12 is also supported. The group of constituent paths that belong to a concatenated signal is determined by the Telecommunication Network Management (TNM) and written to an internal configuration table. Using this information, the SURPASS hiT 7060 software is able to set signal fail or signal degrade alarms for all paths of a concatenated signal channel. In order to keep the (differential) delay of the signals low, all constituent paths of a concatenated signal must be on the same optical trail. It results in a bundling rule for the TNM.
5.2.3
36 (150)
System Description
SDH
PDH
Nx STM-N AUG AU-4 VC-4 C-4 3x D34 TUG-3 7x TUG-2 3x TU-12 VC-12 C-12 D2 2 Mbps 1x TU-3 VC-3 C-3 D45 45 Mbps 34 Mbps
N = 1, 4 or 16
Fig. 5.3
5.2.3.1
SURPASS hiT 7060 implements the following HO/LO multiplexing and mapping methods:
VC-4 containers are aligned (with frame offset information) with an AU-4, according to ITU-T G.707. The AU-4 may further be mapped via AUG-1 into STM-1, or further via AUG-4 into STM-4. STM-16 follows the same pattern. VC-3 containers are aligned (with frame offset information) with a TU-3, according to ITU-T G.707. The TU-3 is further mapped via TUG-3 into VC-4. VC-12 containers are aligned (with frame offset information) with a TU12, according to ITU-T G.707. The TU-12 is further mapped via TUG-2 and TUG-3 into VC-4.
5.2.3.2
SURPASS hiT 7060 implements the following mapping of PDH signals on SDH containers:
37 (150)
System Description
2 Mbps signals are mapped into a VC-12 asynchronously, according to ITU-T G.707. The VC-12 is further mapped on a VC-4, via TU-12, TUG2 and TUG-3. 34 Mbps and 45 Mbps signals are mapped into a VC-3 asynchronously, according to ITU-T G.707. The VC-3 is further mapped on a VC-4, via TU-3 and TUG-3.
5.2.3.3
SURPASS hiT 7060 supports Ethernet frame mapping into SDH containers. So LAN traffic can be transported over different SDH payload sizes (requires encapsulation by using an appropriate protocol and mapping of the resulting frame into an SDH container). For encapsulation, the GFP (GFP-F according to ITU-T G.7041) is used. The encapsulated protocol frames can be mapped into different SDH containers using the virtual concatenation technique. Ethernet Mapping into SDH Containers SURPASS hiT 7060 supports a flexible mapping scheme:
Ethernet Mapping into HO virtually concatenated containers Encapsulated GFP-F frames can be mapped into different HO container sizes providing a scalable solution that can cover network applications with very different transport capacity requirements. Mapping into VC-4, VC-4-Xv (x = 1 to 7) The GE interface cards support this mapping function.
Ethernet Mapping into LO virtually concatenated containers Encapsulated GFP-F frames can be mapped into different LO container sizes providing a scalable solution that can cover network applications with very different transport capacity requirements. Mapping into:
VC3, VC-3-Xv (x=1 to 3 for FE or x=1 to 21 for GE) VC12, VC-12-Xv (x = 1 to 46)
The virtual concatenation for VC-3 supports both FE and GE. GFP-F Mapping GFP is supported by the FE interfaces. GFP provides a generic mechanism to adapt traffic from higher-layer client signals over an octet synchronous transport network. This is a simple and robust encapsulation method for packet traffic. All of the relevant MAC layer information, from destination address through Frame Check Sequence (FCS) inclusive, is preserved intact by the mapping.
38 (150)
System Description
SURPASS hiT 7060 uses a Protocol Data Unit (PDU) oriented, frame-mapped adaptation mode (GFP-F) for the client signal adaptation. GFP-F does not rely on flag characters, and associated control escape octet, for frame delineation purposes as High level Data Link Control (HDLC) does. Instead, GFP-F uses a variation of the Header Error Control (HEC) based frame delineation mechanism defined for Asynchronous Transfer Mode (ATM). This avoids non-deterministic expansion of the client signal due to insertion of control escape characters.
5.3
For the 6 FE/L2 card, the LAN port rate limit ranges are from 200 Kbps to 100 Mbps in the step of 1 Kbps. For 2 GE + 8 FE/AE card, the LAN port rate limit ranges are from 64 Kbps to 100 Mbps for FE interfaces and from 64 Kbps to 1000 Mbps for GE interfaces in the step of 64 Kbps.
Link aggregation SURPASS hiT 7060 supports link aggregation function on FE ports for LAN or WAN side.
39 (150)
System Description
Jumbo frame SURPASS hiT 7060 supports up to 9.6 K bytes long MAC frame which substantially facilitates the transmission of bandwidth-demanding service such as video and broadband access.
5.4
T3 T2 T1 Selection SETS
T4
T0
Fig. 5.4
5.4.1
From any STM-1/4/16 ports (T1) From any one of 2 Mbps interfaces in E1 card (T2) From any external station clock input ports (T3). From the internal Stratum 3 clock (ITU-T G.813 Option 1)
40 (150)
System Description
A SURPASS hiT 7060 NE can run in free running, holdover, or locked mode. The normal synchronous mode is locked mode. If all of the reference sources fail, the system will switch to the holdover mode. The accuracy of the local oscillator is 12 ppm. A Synchronization Status Message (SSM) signal can be used to transfer the signal quality level throughout a network. This will guarantee that all NEs will always be synchronized to the highest quality clock available. SURPASS hiT 7060 supports SDH SSM algorithm on all STM-N interfaces and on the framed 2 Mbps synchronization output signal (connected to the station output clock):
SSM function support can be user provisioned as enabled or disabled. When the SSM function is disabled in the NE, all STM-N interfaces and the framed 2 Mbps synchronization output signal interfaces will send out a DNU (do not use for sync) signal. There are 4 possible quality levels specified in the SSM for timing reference sources: PRC, SSU-A, SSU-B, and SEC. In addition, DNU is specified in SSM. The quality of each timing reference source can either be retrieved from the incoming the SSM or provisioned from the network management system. SURPASS hiT 7060 supports the synchronization source switching algorithm based on SSM defined in ITU-T G.781. The wait-to-restore (WTR) time for the timing reference source is between 0-12 minutes and can be set from the network management system in minute increments. The default value is 5 minutes.
5.4.2
T0 System Clock
The T0 system clocks are used in the NE for traffic processing, OH/DCC busses, internal system communication between the SC card and each card, and for the distribution of the absolute time. T0 clocks to each LC and MC slot include the following three signals:
Clock signal 77 MHz; point to point distribution. Frame clock signal 2 kHz; point to point distribution. Absolute time signal 1 Hz; point to point distribution. Clock signal 19 MHz; point to point distribution. Frame clock signal 2 kHz; point to point distribution. Absolute time signal 1 Hz; point to point distribution.
41 (150)
System Description
5.4.3
5.4.4
5.5
Retiming
In the retiming mode, the transmitter eliminates wander and jitter in the incoming clock. While the rate of the outgoing 2 Mbps signal is normally equal to the rate of the 2 Mbps signal going into the SDH network, occasionally this relationship disappears. A retiming function is necessary for suppression of jitter and wander which the 2 Mbps signal suffers during transmission in SDH and which makes the signal useless for carrying the synchronous frequency to the PDH domain. To retime an outgoing 2 Mbps signal, means simply to retime this signal with the internal clock of the multiplexer equipment in which the desynchronization takes place. This can be done by reading the recovered 2 Mbps signal into an elastic store and timing the output of the elastic store with the system clock. When the device is set in the retiming mode all jitter and wander due to the multiplexing or demultiplexing process in the transmission is eliminated.
5.6
42 (150)
System Description
be switched off automatically. After the receiver receives a valid signal again, the laser transmitter is then switched on automatically.
5.7
Major urgent alarm (triggered by any Critical or Major alarms) Minor non-urgent alarm (triggered by any Minor alarms)
5.8
43 (150)
System Description
Note Traditional EOW over E1/E2/F1 is available for SURPASS hiT 7060. This solution is based on management mode. In this mode SURPASS hiT 70 XOW can be managed via LCT or TNMS-M. Operators can assign or manage the telephone numbers in the box through the LCT or Telecommunication Network Management System (TNMS). At the same time the TNMS can obtain the state and events from the box. SURPASS hiT 7060 uses VoIP technology to provide EOW function over DCC. When the Data Communication Network (DCN) tunnel function is enabled, VoIP is not recommended to be used.
5.9
Software/Firmware
The SC card is equipped with micro controllers for monitoring, controlling, and maintaining status information. They are programmed with embedded firmware held in Flash-EPROMs. A Compact Flash (CF) card is provided which can be installed in the SC card. All the software load of the NE is embedded in the CF card at the beginning. System gets the software from CF card while booting the NE for the first time. A new CF card with upgraded software will be provided during the system upgrade. A software download facility is available. The download can be done remotely or locally via the element manager or LCT. The internal configuration database of the system can be uploaded and downloaded. It is stored redundantly and robust to any card failure. Besides the configuration database, there are two embedded software images in the SC card. One is used by the active software and the other is for backup. During the system upgrade, new software will be downloaded and stored into the backup image memory bank. It will then be activated and the active image will be set as the new backup. Two software image designs can efficiently protect the system from system errors caused by wrong operation.
5.10
Protection Architecture
SURPASS hiT 7060 provides powerful network and equipment protection functions.
44 (150)
System Description
5.10.1
Traffic Protection
SURPASS hiT 7060 supports the following traffic protection functions:
Note Traffic protection functions are partly coupled with equipment protection features. This is generally achieved by including some hardware components (e.g. SFP modules) within a protected signal section. Each of the protection function is described as follows: SNCP SURPASS hiT 7060 supports both unidirectional and bidirectional SNCP protection on STM cards at VC-12, VC-3, VC-4, VC-4-4c and VC-4-16c levels. SNCP protection includes both inherently monitored SNCP/I and nonintrusively monitored SNCP/N. The protection switching time for SNCP is less than 50 ms. MSP SURPASS hiT 7060 supports 1 + 1 MSP function on STM-1, STM-1E, STM-4 and STM-16 interfaces. In 1 + 1 MSP, one dedicated channel is reserved to protect only one working channel. The client traffic is always transmitted over the working and protection path simultaneously. In the case of the fiber break, the incoming traffic from the protection path will be selected automatically. All STM optical ports support both unidirectional and bidirectional 1 + 1 MSP functions in revertive and non-revertive modes. 2-fiber MS-SPRing 2-fiber MS-SPRing is a bidirectional ring in which both directions of traffic transmission use the same set of nodes under normal conditions. In the case of the failure on the working path, the traffic will be switched to the protection path. SURPASS hiT 7060 supports MS-SPRing at STM-16/4 level. The protection (detection and switching) is guaranteed to be finished within 50 ms. The WTR time is user configurable with a default value of 5 minutes. DNI SURPASS hiT 7060 supports DNI protection between two MS-SPRings.
45 (150)
System Description
5.10.2
Equipment Protection
SURPASS hiT 7060 provides the equipment protections as follows: 1 : N protection for electrical 2 Mbps interfaces SURPASS hiT 7060 supports an optional 1 : N (N=1 to 2) protection for the 2 Mbps PDH interface cards. The automatic protection switching related information coming from the 63 x E1 working card (or protection card) is sent to the SC unit. When an E1 1 : N protection related defect is reported on the 63 x E1 working card (or protection card) and correlated by software as a valid Protection Switch Request (PSR), the SC module initiates a switch to the protection card (or the working card). As a result, the customer traffic will be forwarded through the protection bus to the protection card. The switch matrix will then select the traffic from the protection card. 1 + 1 protection for electrical 34/45 Mbps and STM-1E interfaces SURPASS hiT 7060 supports an optional 1 + 1 protection for the 34/45 Mbps PDH interfaces and STM-1 electrical interfaces. The automatic protection switching related information coming from the 3 E3/DS3 or 4 x STM-1E working card (or protection card) is sent to the SC unit. When an E3/DS3 or STM-1E 1 + 1 protection related defect is reported on working card (or protection card) and correlated by software as a valid PSR, the SC module initiates a switch to the protection card (or the working card). As a result, the customer traffic will be forwarded through the protection bus to the protection card. The switch matrix will then select the traffic from the protection card. Switch fabric, clock unit and power unit protection In SURPASS hiT 7060 the SETS is integrated as a module inside the switch fabric card. Every NE can always be equipped with working and protection fabric/clock cards. All the transmission functions and information within the working switching fabric will be duplicated and stored within the protection switching fabric, so that in case of failure, the protection switching fabric will take over the task of the defect switching fabric without any major delay. From the SETS point of view, the working card will be configured as a master and synchronized to a reference source, while the protection card will be operating as a slave and synchronized to the working card. In the event of failure of the working card, the protected card will take over the synchronization function from the defect card. SURPASS hiT 7060 provides 1 + 1 power unit protection. In the event of failure of working power card, the protection power card will take over the power function from the defect card.
46 (150)
System Description
5.11
5.12
5.12.1
47 (150)
System Description
IP over OsiLight
IP over OsiLight
hiT 7060
Fig. 5.5
5.12.2
48 (150)
System Description
SMA 1/4
LADP / GRE
hiT 7060
IP based DCC
hiT 7060
LADP / GRE
SMA 1/4
Fig. 5.6
While the systems DCC works in GRE bypass mode, the system will transparently forward the DCC packet to another port regardless of any L2 or above protocol (either LAPD/OSI or HDLC/PPP).
5.12.3
49 (150)
System Description
Third party NE
DCC transparency
Third party NE
Fig. 5.7
5.12.4
50 (150)
System Description
Fig. 5.8
ECC Applications
51 (150)
52 (150)
SURPASS hiT 7060 Hardware ETS System Rack SURPASS hiT 7060 Subrack Fan PWR SC CCS16 (1) 1 STM-16 (1) 4 STM-4/STM-1 (1) 2 STM-1 (1) 4 STM-1E (W/P) 4 STM-1EW (W/P) 4 STM-1E/EC 3 E3/DS3 (W/P) 3 E3/DS3 EC (75 Ohm) 63 E1/R (W/P) 63 E1/EC (75 Ohm and 120 Ohm) 2 GE/T (1) 2 GE + 8 FE/AE (1) 2 GE + 8 FE RPRE (1) 8 FE/T 6 FE/L2 OA (1) Can be equipped with various pluggable optical transceiver modules (SFP) Software Package TNMS-M LCT TNMS-M LCT Hardware TNMS-M LCT Software
Fig. 6.1
6.1
53 (150)
The Main shelf consists of 1 SC slot, 2 power slots, 2 CC slots, 11 traffic slots and 6 IO slots, which can be flexibly configured for interface cards usage. The subrack layout is shown in Fig. 6.2. The Extension Shelf is named as SURPASS hiT 7035 Extension Shelf and it is designed to simultaneously support 252 E1 to add/drop in single subrack. For details about Extension Shelf, please refer to the SURPASS hiT 7035 Extension Shelf Technical Manual.
System Management Interface panel Power Slot (1) Power Slot (2)
SC Slot
2 x CC Slots
Fig. 6.2
The SURPASS hiT 7060 Main Shelf slot arrangement and Extension Shelf connectivity diagram are shown in Fig. 6.3 and Fig. 6.4, and card availability for each slot is depicted in Tab. 6.1.
54 (150)
P W R 1
E C 1
E C 2
E C 3
L C 1 C C 1 C C 2
L C 2
E C 4
E C 5
E C 6
P W R 2
L C 3
L C 4
L C 5
L C 6
L C 7
L C 8
L L L S C C C C 9 10 11
Fig. 6.3
55 (150)
252 2 Mbps
252 2 Mbps
252 2 Mbps
252 2 Mbps
Fig. 6.4
56 (150)
Slots
SC
CC 1 to
LC 1 to 2
LC 3
LC 4
LC 5 to 6
LC 7 to 8
LC 9 to 10
LC 11
EC 1
EC 2
EC 3
EC 4
EC 5
EC 6
PWR 1 to 2
F A N
Cards SC PWR FAN CCS16 1 STM-16 4 STM-4 4 STM-1 2 STM-1 4 STM-1E (W/P) 4 STM1E/EC 4 STM-1EW (W/P) 2 3 E3/DS3 (W/P) 3 E3/DS3 EC 63 E1/R (W/P) 4 63 E1/EC 4 2 GE + 8 FE/AE 2 GE + 8 FE RPRE 2 GE/T 8 FE/T 6 FE/L2 OA
1 1
3
Tab. 6.1
57 (150)
Note
1. 2.
While the 4 STM-4 card is equipped in LC1, LC2, LC5 or LC6 slot, only the first port is supported, and this card would be seemed as 1 STM-4. The 4 STM-1EW card has the same functions as the 4 STM-1E card except the E1/E2 and F1 overhead supported. Both of these two function cards can only interwork with the same type to provision 1 + 1 hardware protection. The 2 GE + 8 FE/AE and 2 GE + 8 FE RPRE cards have the same functions as the old data service cards (2 GE+ 8 FE/A, 2 GE + 8 FE RPR). The only distinguishing feature is that the enhanced cards, which include the capital letter E in the name, can be reused in SURPASS hiT 7060 release 4.x subracks.
The 63 E1/R (W/P) and 63 E1/EC cards are long cards. The slot arrangement is shown in Fig. 6.5.
3.
4.
58 (150)
P W R 1 L C 4 L C 3 L C 5 L C 6
L C 1 C C 1 L C 7 C C 2
L C 2 L C 9 L C 8 L L C C 10 11
P W R 2
S C
Fig. 6.5
6.2
59 (150)
Card Name Power Supply FAN Unit Air Filter SC CCS16 1 STM-16 4 STM-4/STM-1 2 STM-1 4 STM-1E (W/P) 4 STM-1EW (W/P) 4 STM-1E/EC 3 E3/DS3 (W/P) 3 E3/DS3 EC 63 E1/R (W/P) 63 E1/EC 2 GE/T 2 GE + 8 FE/AE 2 GE + 8 FE RPRE 6 FE/L2 8 FE/T OA
Explanation -48 V (range -40 V ~ -72 V) DC power supply Fan unit Air filter System Controller Cross-Connection and timing function card with 1 STM-16 or 1 STM-4 optical interface 1 STM-16 optical interface card 4 STM-4/1 optical interfaces card 2 STM-1 optical interface card 4 STM-1 electrical interfaces card with 1 + 1 protection function, but the E1/E2 and F1 overhead are not supported. 4 STM-1 electrical interfaces card with 1 + 1 protection function, E1/E2 and F1 overhead are supported. 4 STM-1 electrical interfaces card 3 E3/DS3 electrical interfaces card with up to 1 : 2 protection function 3 E3/DS3 electrical interfaces card, 75 Ohm impedance 63 E1 electrical interfaces card with retiming function 63 E1 electrical interfaces card, 120 Ohm or 75 Ohm impedance 2 GE transparent optical interfaces card 2 GE optical interfaces and 8 FE/AE electrical interfaces card with L2 functions 2 GE optical interfaces and 8 FE electrical interfaces card with RPR functions 6 FE/L2 electrical interfaces card with L2 functions 8 FE electrical interfaces card with transparent transmission 1 channel uni-directional optical amplifier, can be used as pre-, post-, or inline amplification applications
Tab. 6.2
For more detailed information about the modules and cards, please refer to the following chapters.
60 (150)
6.3
Fig. 6.6
61 (150)
LEDs
LED Name Power Fault Color Green Red Status ON OFF ON OFF Functional Description Power is on. Power is off. There are fault conditions presented in this card This card is in normal condition
Tab. 6.3
6.4
Fan Tray
SURPASS hiT 7060 has one fan tray to support subrack cooling. The fan tray is equipped with 8 fans and is located at the bottom of the subrack. The fan tray is replaceable when the system is in service. Faceplate
Fig. 6.7
6.5
Air Filter
The air filter provides air filtering function. The air filter is located at the bottom of the SURPASS hiT 7060 subrack. Faceplate
62 (150)
Fig. 6.8
6.6
Fig. 6.9
SC Card Faceplate
63 (150)
LEDs
Name CF ACTIVE PWR Color Green Green Green Status ON OFF ON OFF ON OFF ON OFF Functional Description CF card is equipped CF card is unequipped This module is in the active mode This module is in the standby mode Power is available to the system Power is off There are fault condition on this module There is no alarm on this module
FAULT
Yellow
Tab. 6.4
SC Card LEDs
6.7
Alarm LEDs: CR MJ MN
64 (150)
Fig. 6.10
Interfaces The following table lists the interface and control buttons on this panel:
65 (150)
EOW1/2
RJ 45 connector to provide 2 EOW channels It is possible to provision slot and port that the interface will connect with SUPRASS hiT 70 XOW for communicate with the remote station. Each provides a 64 Kbps channel.
EOW3/4
RJ 45 connector to provide 2 EOW channels. It is possible to provision slot and port that the interface will connect with SUPRASS hiT 70 XOW for communicate with the remote station. Each provides a 64 Kbps channel.
MDI
1 RJ 45 connector to provide 4 MDI ports. MDIs are used to read the status of external alarm-points. Both the MDI description and severities are provisionable on the management system.
MDO
1 RJ 45 connector to provide 2 MDO ports. MDOs are used to drive external devices. MDO actions are activated or deactivated manually by the management system.
1 RJ 45 connector, providing 2 alarm outputs LED test button The alarm outputs will be cut off or switched by pushing the button once a time. System indicators (critical/major/minor LEDs) on the NE are not suppressed; all alarm output to bay-top-alarming-module will be cut off. On the panel the existing alarms will not be shown on the system and the rack-top alarm panel when the button is pushed a time. The new alarm will still be output. A one state suppress button to suppress the current alarm output on the audible and visual indicators. The alarm indicators (critical/major/minor LEDs) of both NE system and rack-top alarm panel are also suppressed.
Tab. 6.5
66 (150)
LEDs
LED name PWR Color Green Status On Off On Flashing Description The power supply is on and working in normal condition There is no power One or more critical alarms are present One or more critical communication alarms are present CR Red Or any card is mismatch or faulty (Major alarm LED will flash at the same time) No critical communication alarms are present, and card/system is in service When any optional service card is mismatch or faulty, Major alarm LED and Critical alarm LED will flash at the same time There are one or more major alarms present No major alarms There are one or more minor alarms present No Minor alarms Off (Note: warning and indeterminate alarms wont turn the LED on.)
Tab. 6.6
6.8
Cross-connection and Timing Card with one STM16/4 optical interface: CCS16
This module integrates cross-connection fabric and one STM-16/4 optical interface. The optical interface working modes (STM-16 or STM-4) can be configured through LCT. In addition, the card provides a cross-connection function and timing function. The following sub-chapters describe its functions.
67 (150)
6.8.1
P W R
E C 1
E C 2
E C 3
L C 1
L C 2
E C 4
E C 5
E C 6
P W R
2 x 155 Mbps
L C 3
L C 4
L C 5
L C 6
L C 7
2.5 Gbps
L C 8
L C 9
L C 10
L C 11
S C
Fig. 6.11
68 (150)
6.8.2
Timing Function
The Timing function selects a recovered clock from one of the line inputs, a station clock from the central office (two independent connections are provided), an E1 tributary input, or an internal Stratum 3 (supports ITU-T G.813 Option 1 Stratum 3) reference (on the cross-connection and timing module) as the system-timing reference. Operator can provision any of the clock inputs as a primary or secondary timing source. Operator can identify up to four timing references, which can be prioritized to provide protection. A slow-reference tracking loop allows the timing function to synchronize to the recovered clock, which provides holdover if the reference is lost. For detailed information about timing function, please refer to Chapter 5.4.
6.8.3
69 (150)
External Interfaces
Interface STM-16 optical interface Description LC connector
STM-16 SFP options: STM-16 (L16.3, 80 Km) STM-16 (L16.2, 80 Km) STM-16 (L16.1, 40 Km) STM-16 (S16.1, 15 Km) DWDM 2.5 G SFP, 120 Km CWDM 2.5 G SFP STM-16 (L-16.2, 120 Km, with 13 dBm booster amplifier) STM-16 (L-16.2, 160 Km, with 18 dBm booster amplifier) DWDM SFP, 180 Km, with 18dBm booster amplifier at TX, DCM and Pre-optical amplifier at RX
DWDM options:
LC connector
STM-4 SFP options: STM-4 (V4.2 120 Km) STM-4 (L4.2 80 Km) STM-4 (L4.1 40 Km) STM-4 (S4.1 15 Km) Bidirectional STM-4 SFP
Tab. 6.7
70 (150)
6.8.4
Fig. 6.12
LEDs
LED Name PWR ACT Color Green Green Status ON OFF ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off The card is in working state The card in standby state There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.8
6.9
71 (150)
The current optical line interface on this module uses SFP with multiple SFPs for different transmission distance applications. The optical line interfaces also support ALS function, and support optical performance monitoring including bias current, input and output optical power. For the traffic slots available for this card, please see Tab. 6.1.
Faceplate
Fig. 6.13
72 (150)
External Interfaces
Interface STM-16 optical interface Description LC connector
STM-16 SFP options: STM-16 (L16.3, 80 Km) STM-16 (L16.2, 80 Km) STM-16 (L16.1, 40 Km) STM-16 (S16.1, 15 Km) DWDM 2.5 G SFP, 120 Km CWDM 2.5 G SFP STM-16 (L-16.2, 120 Km, with 13 dBm booster amplifier) STM-16 (L-16.2, 160 Km, with 18 dBm booster amplifier) DWDM SFP, 180 Km, with 18dBm booster amplifier at TX, DCM and Pre-optical amplifier at RX
DWDM options:
Tab. 6.9
LEDs
LED Name PWR Color Green Status ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.10
73 (150)
6.10
Faceplate
Fig. 6.14
External Interfaces This STM-4/1 interfaces support both optical and electrical SFP modules. In this version, system only supports electrical SFP modules for STM-1 rates.
74 (150)
Description LC connector
STM-4 SFP options: STM-4 (V-4.2 120Km) STM-4 (L-4.2 80Km) STM-4 (L-4.1 40Km) STM-4 (S-4.1 15Km) STM-1 (V-1.2 120Km) STM-1 (L-1.2 80Km) STM-1 (L-1.1 40Km) STM-1 (S-1.1 15Km)
DIN 1.0/2.3 75 Ohm, SFP Electrical Interface module: Typical cable length: 100 meter (attenuation at 78 MHz must be less than 13.7 dB)
Tab. 6.11
LEDs
LED Name PWR Color Green Status ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.12
75 (150)
Note It is not possible to mix STM-1 and STM-4 modes at the same time in the same card.
6.11
Faceplate
Fig. 6.15
External Interfaces This STM-1 interfaces support both optical and electrical SFP modules.
76 (150)
Description LC connector
STM-1 SFP options: STM-1 (V-1.2 120Km) STM-1 (L-1.2 80Km) STM-1 (L-1.1 40Km) STM-1 (S-1.1 15Km)
DIN 1.0/2.3 75 Ohm, SFP Electrical Interface module: Typical cable length: 100 meter (attenuation at 78 MHz must be less than 13.7 dB)
Tab. 6.13
LEDs
LED Name FAULT Color Red Status ON OFF LINK Green ON OFF Description There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
Tab. 6.14
6.12
Electrical 155 Mbps Interface Card: 4 STM-1E (W/P), 4 STM-1EW (W/P), 4 STM-1E EC
Function SURPASS hiT 7060 offers 4 STM-1 electrical interface cards which support redundant (1 + 1) 4 STM-1E module protection.
77 (150)
The redundant (1 + 1) 4 STM-1E protection modules include two functional cards, 4 STM-1E (W/P) or 4 STM-1EW (W/P) and one interface card, 4 STM-1E EC.
The 4 STM-1E (W/P) or 4 STM-1EW (W/P) function cards perform 4 STM-1E signal mapping and framing function. The 4 STM-1E EC card provides 4 STM-1E interfaces. This card is connected to both 4 STM-1E working card and protection card simultaneously.
The 4 STM-1EW (W/P) card has the same functions as the 4 STM-1E (W/P) card except the E1/E2 and F1 support. Either of these function cards should be Interworking with the same type function cards to provision 1 + 1 hardware protection. The following section will take the 4 STM-1E (W/P) card as example. Fig. 6.16 depicts the functional block diagram of 4 STM-1E (W/P) protection modules.
4 STM-1E (W) 4 x STM-1E transceiver & Framing function
4 STM-1E EC
Selector Relay
To CC board via Backplane 4 STM-1E (P) 4x STM-1E transceiver & Framing function
SC
Fig. 6.16
The SURPASS hiT 7060 chassis supports two groups of 4 STM-1E protection module under 25 Gbps/10 Gbps CC module configuration.
78 (150)
The allowable slots for the 4 STM-1E (W/P) interface modules are summarized in Tab. 6.15 for protection.
Protection Pair 1 Card Name 4 STM-1E/EC 4 STM-1E (W/P) (3 slots) Allowable Slots EC2 LC5 (W) LC6 (P) Protection Pair 2 (3 slots) Allowable Slots EC4 LC1 (W) LC2 (P)
Tab. 6.15
For no protection, the 4 x STM-1E (W/P) interface modules are only allowable in the LC1 and LC5 slot. Any pair of STM-1 electrical ports in the same or different 4 STM-1E (W/P) cards can be set to support MSP. Faceplate
Fig. 6.17
79 (150)
Fig. 6.18
Fig. 6.19
External Interface
Interface STM-1E electrical interface Description CC4 connector Transmission distance: 0 to 53 m (-15 dB receiving sensitivity)
Tab. 6.16
LEDs
LED Name PWR ACT Color Green Green Status ON OFF ON Description Power is available to the card Power is off The card is in working state
80 (150)
LED Name
Color
Status OFF
Description The card in standby state There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
ON OFF
LINK
Green
ON OFF
Tab. 6.17
6.13
81 (150)
3 E3/DS3 EC
Selector Relay
SC
Fig. 6.20
The SURPASS hiT 7060 chassis supports four 3 E3/DS3 module protection pairs. The allowable slots for the 3 E3/DS3 (W/P) interface modules are summarized in Tab. 6.18 for protection.
82 (150)
Card Name
LC1 (W)
LC2 (P)
LC5 (W)
LC6 (P)
LC3 (W)
LC4 (P)
Tab. 6.18
For no protection, the 3 x E3/DS3 (W/P) interface modules are only allowable in the LC1, LC3, LC5 and LC9 slot. Faceplate
Fig. 6.21
83 (150)
Fig. 6.22
External Interfaces
Interface E3/D3 interface Description CC4 connector Transmission distances: 0 to 667 m (-20 dB receiving sensitivity)
Tab. 6.19
LEDs
LED Name PWR ACT Color Green Green Status ON OFF ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off The card is in working state The card in standby state There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.20
84 (150)
6.14
63 E1/R (W/P) function card. This card provides ITU-T G.707 asynchronies mapping of E1 signal into a VC-12 container and retiming function.
63 E1/R EC (Electrical Connector) interface card. This card is connected with 63 E1/R (W/P) card to provide 63 E1 interfaces using nine 2 mm connectors. Each E1 interface is a 2.048 Mbits/s electrical interface and is in compliance with the ITU-T G.703 standard. Two different card types for balanced 120 Ohm or unbalanced 75 Ohm signal lines are available for this module.
The 63 E1/R (W/P) and 63 E1/R EC card could work together to provide 63 E1 interface with up to 1 : 2 protection function. The 1 : 2 protection group supports up to 126 E1 ports (Fig. 6.23).
Back Plane
LC4 63 E1 63 E1 (protection)
LC5 63 E1 63 E1 (working)
LC6 63 E1 63 E1 (working)
LC9
LC10
LC11
63 E1 EC 63 E1 EC 63 E1 EC
63 E1 (extra traffic)
63 E1 (working)
63 E1 (working)
Fig. 6.23
85 (150)
In 1 : N protection configuration, SURPASS hiT 7060 supports the extra traffic application. While the LC4 slot is in protection mode the interface card in the LC9 slot can carry extra traffic. However if the LC4 slot shifts to working mode, the LC9 slot will discontinue service, dropping the extra traffic. The retiming function can be supported on any of all 63 E1 ports. It can be enabled or disabled (base on port) through the LCT or TNMS-M. The function block is shown in Fig. 6.24.
Fig. 6.24
Faceplate
63 x E1 / R
Fig. 6.25
86 (150)
Fig. 6.26
63 x E1 / EC ( 120
Fig. 6.27
Fig. 6.28
Fig. 6.29
External Interfaces
Interface Description
87 (150)
Interface E1 interface, electrical, 120 Ohm, balanced E1 interface, electrical, 75 Ohm, unbalanced
Description Using 2 mm Connectors, 1-21, 22-42, 45-63 Transmission distance: 0 to 730 m (-15 dB receiving sensitivity) Using 2 mm Connectors, 1-21, 22-42, 45-63 Transmission distance: 0 to 535 m (-15 dB receiving sensitivity)
Tab. 6.21
LEDs
LED Name PWR ACT Color Green Green Status ON OFF ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off The card is in working state The card in standby state There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.22
6.15
88 (150)
VC-4s; when it is equipped in slot LC 7/8, the bandwidth would be up to 8 VC-4s. The bandwidth of the GE WAN port supports VC-4-Xv (X=17), and the bandwidth of each FE WAN port supports VC-12-Xv (X=146). The functional block diagram of this module is depicted in Fig. 6.30.
Client Interfaces
Network Side 1 GE
2 GE
31 FEs
8 FE
FE PHY
Fig. 6.30
WAN ports aggregation, converging Ethernet traffic streams from different SDH network sides into single port then issue out Multicast IGMP snooping VLAN and double VLAN tagging, providing increased number of VLANs ACL based on MAC addresses Providing per port rate limiting function: the rate range of each port is from 64 Kbps to 100 Mbps (FE) or from 64 Kbps to 1 Gbps (GE), and the rate provisioning granularity is 64 Kbps Providing per VLAN rate limiting function: The rate range of each VLAN is from 64 Kbps to 100 Mbps (FE) or from 64 Kbps to 1 Gbps (GE), and the rate provisioning granularity is 64 Kbps.
89 (150)
Each card has a shareable memory space for both FE and GE interfaces, this memory can accommodate up to 2048 K bytes, which includes the input buffers and output buffers of every FE and GE interfaces. Each interface has also 4 output queues, each of which can accommodate up to 240 K bytes to be sent out. The FE and GE interfaces have different input buffer size, for FE interface the maximum receive buffer is 256 K bytes, and for GE interface it is 750 K bytes. The FE ports support auto negotiation, flow control, IEEE 802.3 and Ethernet II frame structure. GFP encapsulation (ITU-T G.7041/Y.1303) GE WAN port supports VC-4-Xv (X=7 for slots LC7/8, X=4 for Slots LC 1/2/5/6 ) and LCAS function FE WAN ports support VC-12-Xv (X=146) and LCAS function SDH and Ethernet performance monitoring and alarms Up to 60 MSTP ports
Faceplate
Fig. 6.31
There are 4 RJ 45 interfaces supporting up to 8 FE traffic. Each RJ 45 provides 1 or 2 FE interfaces via an external splitter.
Note Each RJ 45 interface has two LEDS to indicate the data receiving and transmitting status for 2 FE interfaces. Take the 1(5) RJ 45 interface as an example, the left LED is used for FE 1 and the right LED is used for FE 5.
90 (150)
External Interfaces
Interface Description
LC Connector
GE Optical SFP Options: GE-ZX (80 Km) GE E (35 Km) GE-LX (10 Km) GE-SX (500 m)
GE optical interfaces
Standard compliance:
Cables:
1000 BASE-T: supports 1000 Mbps data-rate up to 100 meters reach over unshielded twisted-pair Category 6 cable
10 Base-T (IEEE 802.3) 100 Base-T (IEEE 802.3u) 10 Mbps (half-duplex, duplex, and flow control) 100 Mbps (half-duplex, duplex, and flow control) 10 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m 100 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m
FE electrical interfaces
Cables:
Tab. 6.23
91 (150)
Pin Number 1 2 3 4 5 6 7 8
Signal Description TX+ TXRX+ TX+ TXRXRX+ RXTransmit Data+ Transmit DataReceive Data+ Transmit Data+ Transmit DataReceive DataReceive Data+ Receive Data-
FE Port A A A B B A B B
Tab. 6.24
LEDs
LED Name PWR Color Green Status ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.25
6.16
92 (150)
module supports L2 switching, RPR MAC, GFP, VCAT, and LCAS. There are two WAN ports on the network side. For the traffic slots available for this card, please see Tab. 6.1.
The bandwidth of each port is VC-4-Xv (X=18). The total available bandwidth on the network side is 16 VC-4s. The functional block diagram of this module is depicted in Fig. 6.32.
VC-4-Xv (X=18)
2 GE
8 FE
FE PHY
VC-4-Xv (X=18)
Fig. 6.32
The L2 functions:
VLAN and double VLAN tagging, providing increased number of VLANs ACL based on MAC addresses Providing per port rate limiting function: the rate range of each port is from 64 Kbps to 100 Mbps (FE) or from 64 Kbps to 1 Gbps (GE), and the rate provisioning granularity is 64 Kbps.
93 (150)
Providing per VLAN rate limiting function: the rate range of each VLAN is from 64 Kbps to 100 Mbps (FE) or from 64 Kbps to 1 Gbps (GE), and the rate provisioning granularity is 64 Kbps. Source weighted fairness 3 service of classes (class A, class B, and class C). Class A traffic can occupy up to 75% of total RPR bandwidth and only the class A traffic supports strict order transmission. RPR layer protection: steering or wrap protection, provisional Topology discovery The FE ports support auto negotiation, flow control, IEEE 802.3 and Ethernet II frame structure GFP encapsulation (ITU-T G.7041/Y.1303) VC-4-Xv (X=18) and LCAS function SDH and Ethernet performance monitoring and alarms
RPR functions:
Faceplate
Fig. 6.33
There are 4 RJ 45 interfaces supporting up to 8 FE traffic. Each RJ 45 provides 1 or 2 FE interfaces via an external splitter.
Note Each RJ 45 interface has two LEDS to indicate the data receiving and transmitting status for 2 FE interfaces. Take the 1(5) RJ 45 interface as an example, the left LED is used for FE 1 and the right LED is used for FE 5.
94 (150)
External Interfaces
Interface Description
LC Connector
GE Optical SFP Options: GE-ZX (80 Km) GE E (35 Km) GE-LX (10 Km) GE-SX (500 m)
GE optical interfaces
Standard compliance:
Cables:
1000 BASE-T: supports 1000 Mbps data-rate up to 100 meters reach over unshielded twisted-pair Category 6 cable
10 Base-T (IEEE 802.3) 100 Base-T (IEEE 802.3u) 10 Mbps (half-duplex, duplex, and flow control) 100 Mbps (half-duplex, duplex, and flow control) 10 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m 100 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m
FE electrical interfaces
Cables:
Tab. 6.26
95 (150)
Pin Number 1 2 3 4 5 6 7 8
Signal Description TX+ TXRX+ TX+ TXRXRX+ RXTransmit Data+ Transmit DataReceive Data+ Transmit Data+ Transmit DataReceive DataReceive Data+ Receive Data-
FE Port A A A B B A B B
Tab. 6.27
LEDs
LED Name PWR Color Green Status ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.28
6.17
96 (150)
This module can be installed in any slots from LC1, 2, 5, 6, 7 and 8. When it is equipped into slot LC1/2/5/6, the shared bandwidth would be 4 x VC-4s on its network side; when it is equipped into slot LC7/8 , the shared bandwidth would be up to 16 x VC-4s. The functional block diagram of this module is depicted in Fig. 6.34.
GE SFP 1 Dual 1000 Base-X PHY GE SFP 2 EOS (GFP, LAPS, VC-4-Xv)
Network side: Total 16 VC4 bandwidth (to CC module through the backplane)
Fig. 6.34
The GE ports support auto negotiation, flow control, IEEE 802.3 and Ethernet II frame structure. GFP encapsulation (ITU-T G.7041/Y.1303) VC-4-Xv (X=1 to 7 for slots LC7 and 8, X=1 to 4 for slots LC1/2/5/6 ) mapping VC-3-Xv (X= 1 to 21 for slots LC7/8, X=1 to 12 for slots LC1/2/5/6 ) mapping SDH and Ethernet performance monitoring and alarms Jumbo frames
Faceplate
97 (150)
Fig. 6.35
External Interfaces
Interface Description
LC Connector
GE Optical SFP Options: GE-ZX (80 Km) GE E (35 Km) GE-LX (10 Km) GE-SX (500 m)
GE optical interfaces
Standard compliance:
Cables:
1000 BASE-T: supports 1000 Mbps data-rate up to 100 meters reach over unshielded twisted-pair Category 6 cable
Tab. 6.29
98 (150)
LEDs
LED Name PWR Color Green Status ON OFF ON OFF LINK Green ON OFF Description Power is available to the card Power is off There are fault conditions presented in this module This module is in normal condition Optical link is normal Optical link is off
FAULT
Red
Tab. 6.30
6.18
Supports GFP encapsulation (ITU-T G.7041/Y.1303) Scalable bandwidth through VC-12-Xv (X=146), VC-3-Xv (X=1..3) and LCAS
Minimal equipment investment this Ethernet module still provides very attractive services to the end customers, like:
Scalable bandwidth without having to change interfaces A transparent LAN service that hides the complexity of the WAN for end users (a WAN that looks like a LAN) High availability LAN service because of end-to-end SDH protection switching
99 (150)
8 RJ 45 connector s
Fig. 6.36
For the traffic slots available for this card, please see Tab. 6.1.
Faceplate
Fig. 6.37
100 (150)
External Interfaces
Interface Description
10 Base-T (IEEE 802.3) 100 Base-T (IEEE 802.3u) 10 Mbps (half-duplex, duplex, and flow control) 100 Mbps (half-duplex, duplex, and flow control) 10 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m 100 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m
Cables:
Tab. 6.31
LEDs
Name Color Green FE port LED Yellow Status On OFF ON OFF Functional Description The link is up. The link is down. Transmitting or receiving data. No data.
Tab. 6.32
6.19
101 (150)
The FE interface cards provide the means to map FE client signals of type 10/100 BASE Tx into VC-12-Xv for transport. This card has 6 10/100 M Base-T IEEE 802.3 compatible Ethernet interface ports, and can provide traffic aggregation and transmission for up to 2 uplink connections. There are two WAN ports on the network side. Up to 6 10/100 Mbps traffic can be aggregated to 1 or 2 WAN ports and forwarded to an SDH line interface for transmission. Given bursty nature of data traffic, aggregation of multiple port traffic into a single group of virtually concatenated containers allows a more efficient use of the available bandwidth. This module supports following features:
GFP encapsulation (ITU-T G.7041/Y.1303) LO VCAT VC-12-Xv (X=146), the total available bandwidth on the network side is 1 VC-4, VC-3-Xv (X=1...3) LCAS Auto negotiation, flow control, IEEE 802.3 and Ethernet II frame structure Ethernet performance monitoring and alarms VLAN and double VLAN tagging, providing increased number of VLANs ACL based on MAC addresses Rapid Spanning Tree (802.1w), dramatically reducing restoration time L2 multicast functions Providing per port rate limiting function: the rate range of each port is from 200 Kbps to 100 Mbps (FE), and the rate provisioning granularity is 1 Kbps. Providing per VLAN rate limiting function if the VLAN is assigned to a dedicated port: the rate range of each VLAN is from 200 Kbps to 100 Mbps (FE), and the rate provisioning granularity is 1 Kbps. Providing 802.1p QoS/CoS based on Ethernet port and/or VLAN
Each card has a shareable memory space which can accommodate up to 16384 K bytes, which includes the input buffers and output buffers of every FE interface. The buffer is packet based, every packet will occupy 1536 bytes buffer, regardless of the packet size length, e.g. one 64 bytes packet will also occupy 1536 bytes buffer. Each interface has also 4 output queues, each of which can accommodate up to 96 packets to be sent out. The maximum receive buffer is 256 packets.
102 (150)
LAN Port
WAN Port
1 1 2 3 6 RJ 45 4 5 6 Octal 100 Base-T PHY EOS (GFP, LCAS, VC-12-Xv) Total 1 VC-4 to CC via backplane
Layer 2 Function
Fig. 6.38
For the traffic slots available for this card, please see Tab. 6.1.
Faceplate
Fig. 6.39
103 (150)
External Interfaces
Interface Description
10 Base-T (IEEE 802.3) 100 Base-T (IEEE 802.3u) 10 Mbps (half-duplex, duplex, and flow control) 100 Mbps (half-duplex, duplex, and flow control) 10 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m 100 Base-T: 100 Ohm-two pairs shielded twisted pair cable (STP) and two pairs of unshielded twisted pair cable (Category 6 UTP). The reaching distance is up to 100 m
Cables:
Tab. 6.33
LEDs
Name Color Green FE port LED Yellow Status On OFF ON OFF Functional Description The link is up. The link is down. Transmitting or receiving data. No data.
Tab. 6.34
6.20
104 (150)
This OA card provides uni-directional single optical amplifier function with optical performance monitoring capabilities. This card is designed to compensate losses in the entire C band as Booster Optical Amplifier (BOA) or Pre-Optical Amplifier (POA) in the transmission networks. The OA card can be ordered (with different part numbers) to provide the following applications:
Post-amplifier, 13 dBm output power Post-amplifier, 15 dBm output power Post-amplifier, 18 dBm output power Pre-amplifier, 20 dB gain
OA Card Safety Procedures The OA card safety procedures are described in Tab. 6.35.
Feature ALS Description After 500 ms or more of continuous presence of the LOS defect, the laser will automatically shutdown. The reduction of the optical output power at OA input port occurs within 800 ms from the moment loss of optical signal occurs at OA output port. Whenever the OAs input signal vanishes, the OAs optical output signal will be shut down. When the input signal returns, the output power will be restored. The minimum optical signal restore delay is 100 s. The activation for Transmitter/Receiver is less than 0.85 s. The maximum deactivation time of booster is 100 ms. The maximum activation time of an booster is 100 ms. The maximum activation time of preamplifier is 300 ms. Manual Restore "Manual restart" or "Manual restart for test" can only be activated when the laser is shut down.
OA ALS
Tab. 6.35
For the traffic slots available for this card, please see Tab. 6.1.
Faceplate
105 (150)
Fig. 6.40
Fig. 6.41
Fig. 6.42
106 (150)
Fig. 6.43
External Interfaces
Interface Optical Interface Description Connector Type Input power range LC connector Pre-amp Booster amp -35 to -10 dBm -10 to +3 dBm
Tab. 6.36
LEDs
Name LINK Color Green Status ON OFF ON OFF Functional Description The OA optical link is normal The optical link is down There are fault conditions presented in this module This module is in normal condition
FAULT
Red
Tab. 6.37
OA Card LEDs
107 (150)
Fault Management Configuration Management Performance Management Security Management Alarm processing (e.g. AIS, FTP) for localizing faulty equipment in the transmission network. Fault diagnosis at card level (e.g. localizing a faulty card). Specifying and storing configuration data; these can be entered and requested by the network management system or the LCT.
108 (150)
Determining the quality parameters according to the ITU-T Recommendation G.826. Administration of the access authorization in the LCT for various user classes with passwords.
General Fault Management Functions Fault Management is concerned with the detection, localization, isolation, and reporting of failures of the transmission signals processed by SURPASS hiT 7060 and of its equipment. The failures and the failure processing are differentiated in two failure classes: Transmission Failures and Equipment Failures In addition to these two failure categories, SURPASS hiT 7060 supports external alarm contacts, which can be used for signaling any kind of failure. Failures are reported via the management interface and may also lead to alarm indications at the LCT (card indications, NE indications, and transport functions indications). The tasks of the fault management function are listed below:
Detect anomalies Derive defects by eliminating spurious anomalies and to report some of them to the fault management function Trigger automatic maintenance actions (AIS insertion, Laser shutdown, etc.) Perform alarm reduction through correlation of defects Perform further alarm reduction through adjustable persistence checks Time stamp alarm events using the system real time clock Issue spontaneous alarm event notifications to the LCT/OS Use configurable alarm forwarding to prevent the report of unwanted alarm event notifications Report alarms to the local alarm system Indicate fault states of replaceable units Store alarm events and the alarm states in the current problem list for later retrieval Support fault location for diagnosis and maintenance assistance
109 (150)
7.1
7.1.1
7.1.2
A red FAULT LED to indicate card-internal alarms. A green PWR status LED to indicate card power supply status. In addition to the red and green LEDs which have the same behavior as on other cards, the Ethernet cards contain yellow and green LEDs for each port giving information about link status and link activity to the operator and service technicians.
Operating Elements of the Cards No hardware settings have to be made on the printed circuit cards of the cards. The cards are configured by software commands from the operating terminal or from a network management system when commissioning or in the case of later changes. Help Configuration of the cards using software is explained in the TNMS-M SURPASS hiT 7060 LCT Use Manual and in online help.
7.2
110 (150)
SNMP over TCP/IP Sub-network TCP/IP/ PPP/DCC hiT 7060 hiT 7060
Fig. 7.1
7.2.1
111 (150)
Windows Server 2003 or Windows XP operation system SURPASS hiT 7060 LCT software package
For details on SURPASS hiT 7060 LCT software components, please refer to the SURPASS hiT 7060 LCT User Manual.
7.2.2
TNMS-M
The TNMS-M provides both element management and sub-network management functions. It is compliant with the ITU-T Fault Configuration Accounting Performance Security (FCAPS) function and extends these functions to the sub-network level. The TNMS-M not only provides SDH layer management functions, but also supports the management of Ethernet, Resilient Packet Ring (RPR), and ATM services, as well as other data interfacesThe TNMS-M offers a TMF814 northbound Common Object Request Broker Architecture (CORBA) interface to interact with the TNMS Core. More detailed information of the TNMS-M is provided below: TNMS-M Architecture TNMS-M is based on a distributed client, server and database architecture. The implementation technology is independent of operating systems, which enhances system compatibility. The modular software design allows the TNMS-M to provide integrated management of SDH, ATM, RPR, and Ethernet/IP networks in one platform and enables scalability for introducing additional new technologies. The TNMS-M allows multiple TNMS-M clients to manage the same network at the same time. Management at the Network Management Level by The TNMS-M or other higher-level network management system can be reached via the TNMS-M's TMF 814 northbound CORBA interface. Element Management Function TNMS-M offers an advanced graphical interface to facilitate the configuration of each NE. Operations on NEs are shown directly on a graphical chassis view. A graphical interface of the NE shows modules and ports, which directly correspond to the real ones being managed. This gives the operator real-time status information, facilitating the management process. TNMS-M provides standard-based TMN capabilities, including
Fault Management Configuration Management Performance Management Security Management System Administration
112 (150)
Network Management Function TNMS-M provides layered management capabilities. Networks and services of different technologies (TDM, ATM, RPR, Ethernet, etc.) carried over the same MSTP platform can be managed and optimized independently through graphical management interfaces, appearing as if they were independent networks. One network of MSTP equipment will appear to the user as three different networks: an SDH network, an IP/Ethernet network, and an ATM network. The TNMS-M offers a total view of the managed MSTP NEs. It provides many sophisticated network level functions in a user-friendly fashion. Graphical End-to-End Provisioning and Maintenance TNMS-M supports multi-service (TDM, ATM, RPR, Ethernet, etc.), graphical, end-to-end, and fast service provisioning. This makes the creation, maintenance and management of services significantly simpler for operators. Utilization Statistics of Network Resources and Bandwidth This helps service providers optimize their networks by discovering potential bottlenecks. Topology Management TNMS-M provides a variety of network topology information. For instance, the SDH synchronization topology enables direct view and real-time monitoring of the timing status and timing relationship between NEs. The TNMS-M shows the topology map with different icons to indicate different types of NEs and by using different lines to indicate different bandwidth and various other userfriendly features. Correlation Analysis among Circuits, Performance Management Data and Alarms TNMS-M provides intelligent alarm correlation analysis to enhance troubleshooting. NEs Auto-Discovery and Network Auto-Construction For details on TNMS-M software components, please refer to the TNMS-M User Manual.
7.3
Database backup and recovery The TNMS-M is designed to allow operators to select the database backup as either a backup per request, or to perform backups
113 (150)
periodically (using pre-defined tasks). All backups will be maintained in the backup table. Operators can retrieve any backup copies as needed. The database backup tool can work independently of the network management system. This feature ensures that even if the network management system does not run, the database can still be backed up in time.
Management Information Base (MIB) backup and recovery A copy of the MIB in an NE can be transmitted to and saved at the Synchronization Network Manager (SNM) or kept in the NE. When the MIB fails, the backup copy of the MIB can be downloaded to the NE for use. The TNMS-M provides the switch over from the current MIB to the backup MIB. The system provides a separate MIB backup tool (integrated with database backup tool), which can do periodic backup and management.
NE software recovery The TNMS-M supports remote NE software download and switch over between NE software loads.
7.4
NE Software
The SURPASS hiT 7060 NE software architecture is highlighted in Fig. 7.2.
114 (150)
TNMS-M, or TNMS-M SURPASS hiT 7060 LCT SURPASS hiT 7060 SNMP Agent
Hardware Drivers
Fig. 7.2
7.4.1
115 (150)
TM (Timing Management) module IFM (Interface Management) module Data management module MSP, MS-SPRing and SNCP service protection module
Each software sub-system can be divided into two layers: Manager and Agent. The main function of the Manager is to receive requests from the network management system, and then convert them into operating commands, which will be sent to the Agent. The Agent then receives operating commands from the Manager, and fulfills the configuration function via the interface provided by the hardware driven module. In addition, the Agent is in charge of collecting hardware information (for example, hardware failure and and performance statistics), and sending them to the Manger. After related processing, the Manager converts this data into information the network management software can read and sends it to network management software.
7.4.2
Hardware initialization System auto testing Hardware configuration Interruption service Hardware information inquiring Alarm/Performance monitoring data collection and reporting
7.4.3
116 (150)
7.4.4
SNMP Agent
The SURPASS hiT 7035 embedded software includes a standard SNMP agent module. The SNMP agent is responsible for responding to all EMS/SNM requests including information requests and action requests. It will also automatically generate event reports to the EMS/SNM. The SNMP communication protocol includes 3 operations: Get, Set, and Trap. Through these 3 combined operations, the SNMP Agent can fulfill all configuration management and alarm monitoring functions by communicating with the MIB in the NE. The intercommunication process among the SNMP Agent, the MIB management module, and the application management module is as follows: the SNMP Agent receives requests from network management software, and then sends these requests to the MIB management module. When the MIB management module receives requests it will cause the application management module to do the related operations. At the same time, hardware driven modules and some application management modules may generate related events and data, which will be needed to report to network management software. This information will be sent to the network management software via the application management module invoking interfaces provided by the SNMP Agent and transmitting them by Trap.
7.4.5
7.5
Regeneration section DCC (D1-D3 bytes) Multiplex section DCC (D4-D12 bytes)
117 (150)
In SURPASS hiT 7060, DCC is supported on all STM-N interfaces. TNMS-M or TNMS-M SURPASS hiT 7060 LCT enables the user to select which DCC is used on each STM-N interface. TNMS-M supports TMF 814 CORBA northbound interface.
118 (150)
8
8.1
Commissioning
If SURPASS hiT 7060 has to be configured on initial commissioning, an LCT has to be connected to the Ethernet interface of SURPASS hiT 7060. The hardware and software requirements at the craft terminal are described in the SURPASS hiT 7060 LCT User manual. The craft terminal offers a graphical, menu-driven user interface. Detailed information for commissioning the SURPASS hiT 7060 equipment and the operating terminals is given in the SURPASS hiT 7060 Installation and Test Manual.
8.2
Maintenance
The system provides sufficient alarm information to localize and clear the fault at card level. No maintenance at regular intervals is required. Maintenance measures (e.g. fault localizing) can be carried out locally via the local management interface (LCT/TNMS-M) or under remote control via the TCP/IP over DCC (LCT or a network management system). Maintenance of the SURPASS hiT 7060 equipment is described in the SURPASS hiT 7060 Troubleshooting Manual and in the online help system.
119 (150)
Technical Data
9
9.1
Technical Data
SURPASS hiT 7060 performance specifications for all interfaces, protection switching, power consumption, environment conditions and so on comply with the ITU-T recommendations and IEEE standards.
Traffic Interfaces
The following sub-chapters provide information about the SURPASS hiT 7060 TDM and packet interfaces.
9.1.1
120 (150)
Technical Data
Parameters Application Code Supported Distance[km] Laser Types Central Wavelength [nm] Max. Spectral Width [nm] Min. SMSR [dB] Average Launch Power [dBm] Extinction Ratio [dB] Receiver Types Mini. Overload [dBm] Receiver Sensitivity Optical Path Penalty [dB] Max. Reflect. of receiver [dB] Max. Dispersion [ps/nm] Digital Diagnostics Function Note: 1. 2. Single-Longitudinal Mode Side Mode Suppression Ratio
2)
Classification of STM-16/2.5Gbps
S-16.1 ~15 SLM
1)
L-16.1 ~40 SLM 1261~1360 -20dB=1 30 -2 ~ 3 8.2 APD -9 -27 1 -27 NA Yes
L-16.2 ~80 SLM 1480 ~ 1580 -20dB=1 30 -2 ~ 3 8.2 APD -9 -28 2 -27 1600 Yes
Tab. 9.1
121 (150)
Technical Data
Parameters Supported Distance[km] Application Code Data Bit Rate Laser Types Central Wavelength [nm] Channel Spacing [nm] Maximum central wavelength deviation [nm] Max. Spectral Width [nm] Min. SMSR [dB] Average Launch Power [dBm] Extinction Ratio [dB] Output optical eye Receiver Types Mini. Overload [dBm] Receiver Sensitivity [dBm] Optical Path Penalty [dB] Max. Reflect. of receiver [dB] Dispersion [ps/nm] Digital Diagnostics Function Note: 1. 2. 3. 4.
Specifications ~80 C8L1-0D2/ C8L1-1D21) 1.25Gbps/2.67Gbps2) SLM 1471+20m m = 0 to 73) 20 6.5 -20dB=1 30 0~5 8.2 Acc.IEEE802.3/ITU-T G.957 APD -9 -284) 2.5 -27 1600 Yes
C8L1-1D2 for STM-16 application and C8L1-0D2 for GE application. It can support multi-rate applications: STM-16 and GE. 8 channels CWDM SFP are supported. Its optical performance is compliant with G.695. Their wavelengths are 1471 nm,1491 nm, 1511 nm, 1531 nm, 1551 nm, 1571 nm, 1591 nm, 1611 nm. The Rx sensitivity is based on 2.48832 bps bit rate.
Tab. 9.2
122 (150)
Technical Data
Wavelength [nm] 1471 1491 1511 1531 1551 1571 1591 1611
Tab. 9.3
123 (150)
Technical Data
Parameters Application Code Data bit rate Laser Type Wavelength range Wavelength stability Spectral width (-20dB) modulated Side mode suppression ratio Average launch power Extinction ratio Output optical eye Receiver Types Minimum overload Rx sensitivity Path Penalty Receiver reflectance Dispersion tolerance Digital diagnostic function Note: 1.
Specifications V16.2 2.48832 to 2.666057 Gbps Cooled SLM 100 GHz channel grid in the Cband:191.70-196.0THz, Wavelength selected1) For 100 GHz spacing: 12.5 GHz ( 100 pm) 0.5nm > 30 dB 0 dBm + 4 dBm 8.2 dB Acc.ITU-T G.957 APD -7dBm -28dBm 3 dB < -27 dB -2400 ps/nm + 2400 ps/nm Yes U16.2 2.48832 to 2.666057 Gbps Cooled SLM 192.70 THz2) For 100 GHz spacing: 12.5 GHz ( 100 pm) 0.5nm > 30 dB 4 dBm + 7 dBm 8.2 dB Acc.ITU-T G.957 APD -10dBm -28dBm 2 dB < -27 dB -1200 ps/nm + 3600 ps/nm Yes
44 channels DWDM SFP are supported. It can support STM-16 V16.2 applications. Its channel spacing is 100 GHz. Its wavelength table is as follows. DWDM SFP is compatible with DWDM SFP Multi Source Agreement (MSA) (Sept., 2005). Currently, 192.7 THz (1555.75 nm) DWDM SFP will be supported for the U16.2 application. 120km transmission can be supported with U-16.2 SFP plus 13 dBm booster amplifier on G.652 fiber. 160km transmission can be supported with U-16.2 SFP plus 18 dBm booster amplifier on G.652 fiber. 180km transmission can be supported with U-16.2 SFP plus 18 dBm booster amplifier in transmitter, plus the 1555.75 nm filter POA at the receiver on G.652 fiber.
2. 3. 4. 5.
Tab. 9.4
124 (150)
Technical Data
Frequency (THz) 196.00 195.9 195.8 195.7 195.6 195.5 195.4 195.3 195.2 195.1 195.0 194.9 194.8 194.7 194.6 194.5 194.4 194.3 194.2 194.1 194.0 193.9
Wavelength (nm) 1529.55 1530.33 1531.12 1531.90 1532.68 1533.47 1534.25 1535.04 1535.82 1536.61 1537.40 1538.19 1538.98 1539.77 1540.56 1541.35 1542.14 1542.94 1543.73 1544.53 1545.32 1546.12
Frequency (THz) 193.8 193.7 193.6 193.5 193.4 193.3 193.2 193.1 193.0 192.9 192.8 192.7 192.6 192.5 192.4 192.3 192.2 192.1 192.0 191.9 191.8 191.7
Wavelength (nm) 1546.92 1547.72 1548.51 1549.32 1550.12 1550.92 1551.72 1552.52 1553.33 1554.13 1554.94 1555.75 1556.55 1557.36 1558.17 1558.98 1559.79 1560.61 1561.42 1562.23 1563.05 1563.86
Tab. 9.5
125 (150)
Technical Data
9.1.2
Parameters
Application Code Supported Distance[km] Laser Types Central Wavelength [nm] Max. Spectral Width [nm] Min. SMSR [dB] Average Launch Power [dBm] Extinction Ratio [dB] Output optical eye Receiver Types Mini. Overload [dBm] Receiver Sensitivity [dBm] Optical Path Penalty [dB] Max. Reflect. of receiver [dB] Digital Diagnostics Function Note: 1. Multi-Longitudinal Mode
Tab. 9.6
126 (150)
Technical Data
9.1.3
Parameters
Application Code Supported Distance Range [km] Laser Types Central Wavelength [nm] Max. Spectral Width [nm] Min. SMSR [dB] Average Launch Power [dBm] Extinction Ratio [dB] Output optical eye Receiver Types Mini. Overload [dBm] Receiver Sensitivity [dBm] Optical Path Penalty [dB] Max. Reflect. of receiver [dB] Digital Diagnostics Function
Tab. 9.7
127 (150)
Technical Data
Pair(s) in each direction Test load impedance Peak-to-peak voltage Rise time between 10% and 90% amplitudes of the measured steady state amplitude Transition timing tolerance referred to the mean value of the 50% amplitude points of negative transitions Return loss Maximum peak-to-peak jitter at an output port
Tab. 9.8
9.1.5
Bit rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . Bit rate accuracy. . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . Code. . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . Pulse shape. . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . Pulse amplitude (isolated pulse). . . . . . . . . . . . . .. . . . . . . . Jitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pairs in each direction. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . Test load impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
128 (150)
Technical Data
9.1.6
Bit rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Bit rate accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pulse shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nominal peak voltage of a mark (pulse). . . . . . . . . . . . . . Peak voltage of a space (no mark). . . . . . . . . . . . . . . . . . Nominal pulse width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Jitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Return loss 860 kHz to 1 720 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . 1720 kHz to 34 368 kHz . . . . . . . . . . . . . . . . . . . . . . . . . 34 368 kHz to 51 550 kHz . . . . . . . . . . . . . . . . . . . . . . . . Pairs in each direction . . . . . . . . . . . . . . . . . . . . . . . . . . . Test load impedance . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permissible cable attenuation at 17 184 kHz . . . . . . . .
9.1.7
Bit rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Frequency tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Permissible cable attenuation at 1024 kHz . . . . . . . . . . . . Nominal impedance (input and output) according to ITU-T G.703. . . . . . . . . . . . . . . . . . . . . . . . . .
Return loss 51 kHz to 102 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 kHz to 2 048 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2048 kHz to 3 072 kHz . . . . . . . . . . . . . . . . . . . . . . . . . . . .
129 (150)
Technical Data
9.1.8
Parameters
Application Code Supported Distance[km] Laser Types Central Wavelength [nm] Max. Spectral Width [nm]
1000Base-SX ~0.5 MLM 770 ~ 860 RMS=0.85 N/A -9.5 ~ -3 9 10% PIN 0 -20 -19 -17 1 -12 Yes
1000Base-LX ~10 MLM 1270~1355 RMS=4 N/A -9.5 ~ -3 9 15% PIN -3 -22 -21 -19 1 -12 Yes
1000Base ~35 MLM/SLM 1270~1355 RMS=2/ -20dB=1 30 -4 ~ 0 9 15% PIN -3 -24 -23 -22 1 -12 Yes
1000Base-ZX ~80 SLM 1480 ~ 1580 -20dB=1 30 0~4 9 15% PIN -3 -24 -23 -22 2 -25 Yes
Min. SMSR [dB] Average Launch Power [dBm] Extinction Ratio [dB] IEEE802.3 Mask Margin Receiver Types Mini. Overload [dBm] Receiver Sensitivity @BOL Receiver Sensitivity @ HT Receiver Sensitivity @EOL Optical Path Penalty [dB] Max. Reflect of receiver [dB] Digital Diagnostics Function
Note
1.
The1000 Base with extension distance about 35 km and 80 km is a customized product that we will provide to our customs. But according to IEEE802.3, only two standard types (1000 Base-SX and 1000 Base-LX) are defined clearly. Measured at bit error rate (BER) of 10e-12, using 27-1 PRBS test data pattern. To consider of aging factor, we define the receiver sensitivity at the beginning of life (BOL) should be 2~3 dB better than the standard values listed in the ITU-T G.957, according to the application code.
2.
3.
Tab. 9.9
130 (150)
Technical Data
9.1.9
100 Base-T Fast Ethernet poet acc. to IEEE 803.3u Distance variants Nominal bitrate Frequency tolerance Code Connector receptacle Transmitter behavior Output impedance Return loss 100 differential 2 MHz f 30 MHz: > 16 dB 30 MHz f 60 MHz: [16 20 * log(f /30 MHz)] dB 60 MHz f 80 MHz: > 10 dB Level Single amplitude symmetry Rise/fall time Duty cycle DCD Output jitter Overshoot Receiver behavior Output impedance Return loss 100 differential 2 MHz f 30 MHz: > 16 dB 30 MHz f 60 MHz: [16 20 * log(f /30 MHz)] dB 60 MHz f 80 MHz: > 10 dB Signal detect Assert-Time < 1000 ms De-assert-Time < 350 ms BER < 1E-2 Cable behavior Connector plug Cable type Operating distance Shielded RJ45 S/UTP Category 5 < 100 m (9501050)mV 0.98 to 1.02 3 ns c t r,f 5 ns, (10 to 90%) < 0.5 ns (referred to 50 % of Vout) < 1.4 ns peak-peak 0.05 * Vout 100Base-T User class as per IEEE 802.3u 125.000 kBaud 100ppm 4B/5B. scrambled, MLT3 Shielded RJ45
131 (150)
Technical Data
100 Base-T Fast Ethernet poet acc. to IEEE 803.3u Insertion loss 19 dB (12.5 MHz, 100 m)
Tab. 9.10
9.1.10
All details regarding the 10 Base-T physical layer can be found in clauses 7 and 14 of IEEE 802.3.
9.1.11
Parameters
OA Interface
Min. 0 -40 700/85% Max. 65 85 Units C C V/-
Tab. 9.11
132 (150)
Technical Data
Parameters Wavelength Range Pump Laser Configuration Gain Flattening Control Modes Transient Suppress Control Application Types Notes: 1. 2. 3.
Description 1528nm~1562nm Uncooled pump Single or Dual pump, single stage without GFF APC, AGC, and ACC Transient Suppress Circuit Booster or Preamplifier
Note 1 2 3
This wavelength range is specified as the max. wavelength range for the erbium-doped fiber amplifier using in single channel SDH application; This configuration is designed for single channel SDH system up to now; dual pump or dual stages may be required for obtaining high gain or large output power; For single channel SDH application, the GFF (gain flatten filter) is not required for obtaining the fine gain flatness.
Tab. 9.12
BOA Interface
133 (150)
Technical Data
Parameters Wavelength Range Noise Figure Optical Power Detection Accuracy Polarization Mode dispersion Polarization Dependent Gain Return loss Transient Overshoot (5 dB Add/Drop) Transient Suppress Speed (5 dB Add/Drop) Post-amp: 13 dBm output power Input Power Range Small Signal Gain @Pin=-10 dBm Saturation Power @ Pin>-5 dBm Post-amp: 15dBm output power Input Power Range Small Signal Gain @Pin=-10 dBm Saturation Power @ Pin>-5 dBm Post-amp: 18 dBm output power Input Power Range Small Signal Gain @Pin=-10 dBm Saturation Power @ Pin>-5 dBm Notes: 1. The Maximum small signal gain
Min. 1528
Type
Max. 1562
Unit nm dB dB
Notes
General Specifications (for all types Booster) 5.0 0.5 0.3 0.2 45 0.5 0.5 1.0 0.5 0.5 5.5 3
ps dB dB dB ms
3 18
dBm dB dBm 1 2
3 20
dBm dB dBm 1 2
3 23
dBm dB dBm 1 2
13 dBm Booster: when input power<= -5 dBm, maximum small signal gain can be up to 18 dB. 15 dBm Booster: when input power<= -5 dBm, maximum small signal gain can be up to 20 dB. 18 dBm Booster: when input power<= -5 dBm, maximum small signal gain can be up to 23 dB. 2. 3. The Saturation Power is specified at the Maximum Gain Value when the Input Power is larger than -5 dBm; The typical value of Noise Figure is specified at the Maximum Gain and input power of 0 dBm.
Tab. 9.13
Post-amplifier Specifications
134 (150)
Technical Data
POA Interface
Parameters Center Wavelength Wavelength range (Filter Pass-band window @3 dB) Input Power Range Small Signal Gain (include filter attenuation ) Output Power Range @ PIN= -15 dBm Gain flatness Noise Figure Optical Power Detection Accuracy Input Power: -35 to -20 dBm Output Power: -20 to 0 dBm Polarization Mode dispersion Polarization Dependent Gain Return loss Transient Overshoot (5 dB input variance @Constant Power) Transient Suppress Speed (5 dB input variance @Constant Power) Auto-shutdown Hysteresis 0.5 2 dB 2 0.5 ms 40 0.5 1.0 0.3 0.2 0.5 0.5 0.5 0.5 dB dB ps dB dB dB 5.0 -15 -35 -15 20 -10 N/A 6.0 dBm dB dBm dB dB 1 4 -0.25 Min. Typ 1555.75 +0.25 Max. Unit nm nm 3 Notes
Notes:
1. 2. 3. For single channel SDH application, gain flatness is not required. The same as Booster amplifier. A fixed filter (1555.75 nm 0.25 nm @3 dB) which is put after the output of OA to improve OSNR and sensitivity of PA is integrated in PA. DWDM SFP with fixed wavelength 1555.75 nm (both 100 G and 200 GHz grid) will be used when PA is added before optical receiver. Error-free long term transmission should be guaranteed under worst case when input power of PA is -35 dBm ~ -20 dBm and bit rate is 2.5 Gbps.
4.
Tab. 9.14
Pre-amplifier Specifications
135 (150)
Technical Data
9.2
Control Interface
Control interfaces include two network management interfaces for SNM and LCT connections on SI and one system debug interface for Command Line Interface (CLI) connection on SC. SNMP/TCP/IP/Ethernet for Network Management System
10/100 Mbps RJ 45
9.3
Signalling Interface
Signalling interfaces include one external alarm interface for station alarm output, four Miscellaneous Discrete Input (MDI) and two Miscellaneous Discrete Output (MDO) interfaces on the system management interface panel.
9.3.1
SC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 LED (green) PWR 1 LED (red) FAULT 1 LED (green) ACT 1 LED (green) CF
1 LED (green) PWR 1 LED (red) FAULT 1 LED (green) LINK 1 LED (green) ACT
FE Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EC Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
136 (150)
Technical Data
9.3.2
Alarm outputs
Alarm Contacts
Critical/Major . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Minor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical characteristics Switch Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . Load Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inactive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
urgent alarm non-urgent alarm max. 30 VDC/30 VAC max. 500 mA short cut open
9.3.3
MDI Output Interface electrical characteristics Voltage Range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Active. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inactive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MDO Output Interface electrical characteristics Switch Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Load Current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Active. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inactive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.3.4
EOW Interface
VOIP in DCC or E1, E2 channel, please refer to Chapter 9.1.9 for interface specifications.
137 (150)
Technical Data
9.4
9.4.1
Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input Interface T3 Input frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . Balanced mode Input impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage U0P . . . . . . . . . . . . . . . . . . . . . . . . . Unbalanced mode Input impedance. . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage U0P . . . . . . . . . . . . . . . . . . . . . . . . . Output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . Output Interface T4 Output frequency. . . . . . . . . . . . . . . . . . . . . . . . . . Output voltage U0P With balanced load (120 in parallel with 60 pF) . With unbalanced load (75 ) . . . . . . . . . . . . . . . .
138 (150)
Technical Data
9.4.2
Reference. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input Interface T3 Input frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . Balanced mode Input impedance . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage U0P . . . . . . . . . . . . . . . . . . . . . . . . . Unbalanced mode Input impedance . . . . . . . . . . . . . . . . . . . . . . . . . . Input voltage U0P . . . . . . . . . . . . . . . . . . . . . . . . . Output Interface T4 Output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . Output voltage U0P With balanced load (120 Ohm) . . . . . . . . . . . . . . . With unbalanced load (75 Ohm) . . . . . . . . . . . . . .
9.5
9.5.1
Switching time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External switch requests . . . . . . . . . . . . . . . . . . . . . . . . . Internal switch requests . . . . . . . . . . . . . . . . . . . . . . . . . . SD (from MS-DEG) Switching type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wait-to-restore time (for revertive operation). . . . . . . . . . Operation type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
139 (150)
Technical Data
9.5.2
Switching time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External switch requests . . . . . . . . . . . . . . . . . . . . . . . . . Internal switch requests . . . . . . . . . . . . . . . . . . . . . . . . . . SD (from MS-DEG) Switching type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wait-to-restore time (for revertive operation). . . . . . . . . . Operation type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.5.3
External switch requests . . . . . . . . . . . . . . . . . . . . . . . . . . Internal switch requests. . . . . . . . . . . . . . . . . . . . . . . . . . . Switching type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configurable persistency (hold-off time) . . . . . . . . . . . . . . Operation type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.6
Power Supply
140 (150)
Technical Data
Input DC voltage (according to ETS 300 132-2) . . . . . . . . . . . . . . . . Input DC current (according to ETS 300 132-2) . . . . . . . . . . . . . . . . Power consumption (worst case equipped) . . . .. . . . . . . . . . . Maximum power consumption of cards: PWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System Management Interface Panel . . . . . . . . . . . . . . . . . . . CCS16 . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STM-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1E (W/P) . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . 4 STM-1EW (W/P) . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . 4 STM-1E/EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E3/DS3 (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E3/DS3 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/R (W/P). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE/AE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE RPRE . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . 2 GE/T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FE/T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 FE/L2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 dBm OA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 dBm OA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 dBm OA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 dB OA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
141 (150)
Technical Data
9.7
Environmental Conditions
9.7.1
Climatic Conditions
ETS 300 019-1-3 Class 3.1e -5 oC ~ 45 oC 10% ~ 90% (40 oC ) -10 oC ~ 50 oC 5% ~ 95% (40 oC ) ETS 300 019 Class 1.2 -20 oC ~ 60 oC 2% ~ 98% ETS 300 019 Class 2.3 -20 oC ~ 60 oC 2% ~ 98%
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Long term Temperature . . . . . . . . . . . . . . . . . . . . Long term Relative Humidity . . . . . . . . . . . . . . . . Short term Temperature . . . . . . . . . . . . . . . . . . . . Short term Relative Humidity. . . . . . . . . . . . . . . . . Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relative Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . Transport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Relative Humidity. . . . . . . . . . . . . . . . . . . . . .. . . .
9.7.2
ElectroMgnetic Compatibility
ETSI EN 300 386 (2005/04) V1.3.3, Class A EN 55022 (1998) EN 55022 (1998) EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6
Electromagnetic compatibility in compliance with. . . . . . . . . . . . . . . Emission Radiation Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conducted Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Immunity Electrostatic Discharge Immunity. . . . . . . . . . . . . . . . . . . . . . . . . . . . Radiated Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Fast Transient/Burst Immunity. . . . . . . . . . . . . . . . . . . . . . Surges Immunity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Conducted Disturbances Immunity . . . . . . . . . . . . . . . . . . . . . . . . . .
Note This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
142 (150)
Technical Data
9.8
Dimensions in mm
600 2200 600 (W H D) 447 566.3 299 (W H D) (W H) 167 35.5 438 41.5 167 35.5 335 35.5 167 35.5 167 35.5 167 35.5 167 35.5 167 35.5 167 35.5 167 35.5 335 35.5 335 35.5 167 35.5 167 35.5 167 35.5 167 35.5 167 35.5 167 35.5
Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Subrack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cards: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CCS16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STM-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-4/STM-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 STM-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1E (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1E/EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E3/DS3 (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E3/DS3 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/R (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/EC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE/T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE/AE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE RPRE . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FE/T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 FE/L2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OA (all types) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9.9
Weights in kg
26 0.593 2.2
PWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
143 (150)
Technical Data
SC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CC + 1 STM-16/4 . . . . . . . . . . . . . . . . . . . . . . . . . 1 STM-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-4/1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 STM-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1E (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 STM-1E EC . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . 3 E3/DS3 (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E3/DS3 EC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/R (W/P) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 E1/R EC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE/T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE/AE. . . . . . . . . . . . . . . . . . . . . . . . . . 2 GE + 8 FE RPRE . . . . . . . . . . . . . . . . . . . . . . . 8 FE/T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 FE/L2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.365 0.707 0.336 0.351 0.241 0.315 0.263 0.252 0.267 0.680 0.805 0.353 0.386 0.386 0.270 0.270 0.500
OA (all types).. . . . . . . . . . . . . . . . . . . . . . . . . . . .
144 (150)
Abbreviations
Abbreviations
ADM ACL ALS ATM BOA CC CF CLI CLNP CLNS CORBA DC DCC DCCM DCCR DCN DNI ECC EIA EMC EMS EOW EPL EPLan ES-IS ETS ETSI EVC EVPL EVPLan F FCAPS Add/Drop Multiplexer Access Control List Automatic Laser Shutdown Asynchronous Transfer Mode Booster Optical Amplifier Cross-Connection Compact Flash Command Line Interface ConnectionLess Network Protocol ConnectionLess Network Service Common Object Request Broker Architecture Direct Current Data Communications Channel DCC Multiplex Section (bytes D4 to D12) DCC Regenerator Section (bytes D1 to D3) Data Communications Networks Dual Node Interworking Embedded Control Channel Electronic Industry Association ElectroMagnetic Compatibility Element Management System Engineering Order Wire Ethernet Private Line Ethernet Private LAN End System to Intermediate System Routing Exchange protocol European Telecommunications Standard European Telecommunications Standards Institute Ethernet Virtual Concatenation Ethernet Virtual Private Line Ethernet Virtual Private LAN Standardized Interface for the Connection to a Local Craft Terminal Fault Configuration Accounting Performance Security
145 (150)
Abbreviations
FE FTP GE GFP GRE GVRP HDLC HO HOCC IEEE IGMP IP ISP ITMN ITU-T L2 LAN LAPD LC LCT LCAS LED LO LOCC MAC MIB MDI MDO MSOH MSP MS-SPRing MSTP NE
Fast Ethernet File Transfer Protocol Gigabit Ethernet Generic Framing Procedure Generic Routing Encapsulation Generic VLAN Registration Protocol High-Level Data Link Control High Order (SDH Traffic) High Order Cross-Connection Institute of Electrical and Electronics Engineers Internet Group Management Protocol Internet Protocol (G.784) Internet Service Provider Installation and Test Manual International Telecommunication Union-Telecommunication Layer 2 Local Area Networks Link Access Protocol on D Channel Line Card Local Craft Terminal Link Capacity Adjustment Scheme Light Emitting Diode Low Order (SDH Traffic) Low Order Cross-Connection Media Access Control (ISO/IEC) Management Information Base Miscellaneous Discrete Input Miscellaneous Discrete Output Multiplex Section OverHead Multiplex Section Protection Multiplex Section-Shared Protection Ring Multiple Spanning Tree Protocol Network Element
146 (150)
Abbreviations
NEBS NNI OA OH OS OSI PDH PDU POA POP PPP PRC PSR QoS RPR RSOH RSTP SC SDH SETS SFP SNCP SNM SNMP SOH SSM STM STM-N STP TCP TDM TED TMN
Network Equipment Building System Network Node Interface Optical Amplifier Overhead Operating System Open System Interconnection Plesiochronous Digital Hierarchy Protocol Data Unit Pre-Optical Amplifier Point Of Presence Point to Point Protoco Primary Reference Clock Protection Switch Request Quality of Service Resilient Packet Ring Regenerator Section OverHead Rapid Spanning Tree Protocol System Controller Synchronous Digital Hierarchy Synchronous Equipment Timing Source SF Signal Fail (G.783) Small Form-factor Pluggable (Optical Modules) Sub-Network Connection Protection Synchronization Network Manager Simple Network Management Protocol Section Over Head (G.782) Synchronization Status Message Synchronous Transport Module (G.782/G.783/G.784) Synchronous Transport Module, Level N Spanning Tree Protocol Transmission Control Protocol Time Division Multiplex Technical Manual Telecommunications Management Networks (G.782, G.783, G.784)
147 (150)
Abbreviations
TMX TNM TNMS TSMN VC VCAT VCG VLAN VOIP WAN WTR
Terminal Multiplexer Telecommunication Network Management Telecommunication Network Management System Troubleshooting Maunal Virtual Container Virtual Concatenation Virtual Concatenation Group Virtual Local Area Networks Voice Over Internet Protocol Wide Area Networks Wait-To-Restore
148 (150)
Index
Index
External Alarm Interface, 43
ACL, 39 Add/Drop Multiplexer, 15 Air Filter, 62 Application Type, 14 Available Timing Source, 40 Fan Tray, 62 Fast Ethernet Interface, 131 Fast Ethernet Interface Card, 99, 101 Flow control, 39
Gigabit Ethernet and Fast Ethernet Interface Card, 88, 92 Gigabit Ethernet Interface, 130 Gigabit Ethernet Interface Card, 96
Cards Supported, 59 CC + 1 STM-16/4 Optical Interface, 69 Climatic Condition, 142 Commissioning, 119 Commissioning and Maintenance, 119 Component, 52 Control and Monitoring, 110 Control Interface, 136 Cross-connection, 68 Cross-connection and Timing Card, 67
Hardware Protection, 18
Jumbo frame, 40
Laser Safety Shut-down, 42 Linear with Add/Drop Function, 21 Link aggregation, 39 Local Cross-Connection, 16
ECC Application, 50 Electrical 155 Mbps Interface, 128 Electrical 155 Mbps Interface Card, 77 Electrical 2 Mbps Interface, 129 Electrical 2 Mbps Interface Card, 85 Electrical 34 Mbps Interface, 129 Electrical 34/45 Mbps Interface Card, 81 Electrical 45 Mbps Interface, 128 ElectroMagnetic Compatibility, 142 Engineering Order Wire, 43 Environmental Condition, 142 Equipment Protection, 46 Ethernet, 39 Ethernet Functionality, 18 Ethernet Interface, 132 Ethernet Private LAN, 27 Ethernet Private Line, 26 Ethernet Virtual Private LAN, 29 Ethernet Virtual Private Line, 26
MAC address forwarding, 39 Main Feature, 17 Maintenance, 119 Management System Protection, 113 MSP, 45, 140 MS-SPRing, 45, 139 Multiple Ring, 24 Multiplex and Mapping, 36
149 (150)
Index
OA Interface, 132 Operating Terminal, 47 Optical Amplifier Card, 104 Optical STM-1 Interface, 127 Optical STM-16 Interface, 120 Optical STM-16 Interface Card, 71 Optical STM-4 Interface, 126 Optical/Electrical STM-1 Interface Card, 76 Optical/Electrical STM-4/1 Interface Card, 74
SURPASS NE connect to TNMS, 47 Switch Fabric, 17, 35 Synchronization, 40 Synchronization Interface, 138 System Control and Monitoring, 108 System Controller Card, 63 System Description, 32 System Management Interface Panel, 64
T0 System Clock, 41 Technical Data, 120 Terminal Multiplexer, 14 Terminal-to-Terminal, 20 Timing Function, 69 Timing Output Interface, 42 TNMS-M, 112 TNMS-M Embedding, 18 TNMS-M SURPASS hiT 7060 LCT, 111 Traffic Interface, 120 Traffic Protection, 18, 45 Transparent LAN, 39
POA Interface, 135 Power Supply, 140 Power Supply Card, 61 Protection Architecture, 44
User Data Interface, 35
Signalling Interface, 136 Single Ring, 22 Slot Arrangement, 53 SMA NE connect to TNMS, 48 SNCP, 45, 140 Software/Firmware, 44 Standard Compliance, 11 Subrack, 17, 32
VLAN, 39
Weight, 143
150 (150)