Você está na página 1de 2

Feeder Protection 7SC80

5 6 7 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 8 9 10 11 12 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | 13 14 15 16 L | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |

ORDER NUMBER.:

7SC8 0
6

Basic functions
Housing, 12 BI, 8 BO, 1 Life contact

Specification of CT and VT measuring inputs


3 x I LPS/LoPo, 1 x V 4 x I 1 A/5 A, 1 x V 3 x I LPS/LoPo, 4 x V 4 x I 1 A/5 A, 4 x V 3 x I 1A/5A, 1 x Iee (sensitive) = 0,001 to 1,6A/0,005 to 8A, 1 x V 3 x I 1A/5A, 1 x Iee (sensitive) = 0,001 to 1,6A/0,005 to 8A, 4 x V
6) 6)

1 2 3 4 5 6

Rated auxiliary voltage


60 V to 250 V DC; 115 V AC; 230 V AC DC 24 V/48 V DC 24 V/48 V, Battery Monitoring
5)

1 2 3

Unit version
Surface mounting housing Surface/Flush mounting housing with HMI Surface mounting housing with detached HMI

A B C

Region-specific default- and language settings


Region DE, IEC, language German Region World, IEC/ANSI, language English Region US, ANSI, language US-English Region World, IEC/ANSI, language Spanish Region World, IEC/ANSI, language Russian
4) 4) 4) 4) 4)

10

A B C E G

Systeminterface
100 Mbit Ethernet, electrical, 2 x RJ45 connector 100 Mbit Ethernet, with integrated switch, optical, 2 x LC connector multimode 100 Mbit Ethernet, with integrated switch, optical, 2 x LC connector singlemode 24 km
1) 2) 2)

11

9 9 9

| | |
| | | |

| | | | | | |
| |

| | | | | | |
| |

| | | | | | |
| |

| | | | | | |
| |

L L L | | 0 2 3 4

R S T

Protocol for Systeminterface


IEC 61850 IEC61850 + DNP3 TCP IEC61850 + PROFINET IO IEC61850 + IEC60870-5-104
3)

| | |

|
| | | | |

|
| | | | | 14

|
| | | | | 15

|
| | | | | 16

Additional interfaces
no module GPS module

12

0 7

Functionality
MLFB - number 13, 14, 15, 16 for optional features

13

=>"packages"

1) 2) 3) 4) 5) 6)

already contained in position 6 surcharge for optical interface only with 100 Mbit Ethernet electrical and multimode language selectable in preparation The mentioned sensors in chapter "FCM" can be used. For protection related purpose the usability of the sensors have to be checked.

Feeder Protection 7SC80


5 6 7 8 9 10 11 12 13 3 14 F | 15 | | | | |
4)

15

16

ORDER NUMBER:

7SC8 0

ANSI-Nr. Base Package A 50/51 Time-overcurrent protection phase I>, I>>, I>>>, Ip 50N/51N Time overcurrent protection ground IE >, IE >>, IE >>>, IEp 50N(s)/51N(s) Sensitive ground fault protection IEE >, IEE >>, IEEp 50BF Circuit breaker failure protection 46 Negative sequence / unbalanced load protection 49 Thermal Overload protection 87N High impedance REF 74TC Trip circuit supervision 37 undercurrent 51c Cold load pickup 86 Lockout 60CTS CT supervision Parameter changeover Monitoring functions Control of circuit-breaker Flexible protection functions (current parameters) Under- / overfreq Inrush restraint Fault recording, average values, min/max values ANSI-Nr. 67 67N 67N(s) 27/59 81U/O 25 47 64/59N 60VTS 32/55/81R Base Package B (containing A) Directional overcurrent protection phase, I>, I>>, IEp Directional overcurrent protection ground, IE>, IE >>, IEp Directional sensitive ground fault protection, IEE>, IEE >>, IEEp Under-/overvoltage Under-/overfrequency, f<, f> Sync-check Phase rotation Displacement voltage VT supervision Flexible protection functions (current and voltage parameters) Protective function for voltage, power, power factor, frequency change Base Package N (containing R) SNTP-server/master functionality, no protection Base Package R pure RTU functionality, no protection

| | | |

3)

| | | | | | | | | | | | |
1)

| | |

4)

| | | | | | | | |
2) 5)

| | |

2)

| | | |

additional functions without with autoreclose 79 with fault locator 21FL with autoreclose and fault locator 79/21FL with single/triple pole autoreclose 79/TS 79/TS/21FL with single/triple pole autoreclose and fault locator

16

1) 1)

1)

0 1 2 3 4 5

1) Only with position 7 = 3, 4 or 6 2) Only with position 16 = 0 3) 87N (REF) only with sensitive ground current input (position 7 = 5 or 6) 4) Depending on the ground current input the function will be either sensitive (IEE) or non-sensitive (IE) 5) Only with position 12 = 7