(c) Loads are applied on the structure and load combinations are created.
(b) Imported drawing is converted into structural components.
(e) ADAPT-Modeler automatically generates Design Strips (tributaries) for each user-defined Support Line.
(d) Support Lines are generated in two orthogonal directions.
0
(f) Design Strips are exported to ADAPT-PT.
(g) All the information required to make an ADAPT-PT run is already entered in the Input Editor, and the program is ready to calculate.
(h) The program finds a Post-Tensioning Solution based on the design parameters entered by the user. In the Recycling Screen, the user can quickly adjust the provided tendon profile or force to refine the solution.
(i) The user can also find a solution by defining the number of tendons and their position along the support line.
(j) Calculated stresses along the Design Strip are displayed against the background of the allowable stress envelope.
200 300 400 378.8 -535.3 -500 -400 -300 -200 -100 0 100 Span 1 Span 2 Span 3 Span 4 Span 5 Stress Diagrams Project: Pineapple Grove / Support Line 7 / Load Case: Service Tensile Stress Positive S t r e s s
[ p s i ] 1.00 x Selfweight + 1.00 x Dead load + 1.00 x Live load + 1.00 x Prestressing A Allowable Stress Top Allowable Stresses Calculated Stress ADAPT - STRUCTURAL CONCRETE SOFTWARE SYSTEM ADAPT-PT Version 6.18 Date: 2/ 24/2004 Time: 2: 55:28 PM File: Support Line 4 1- PROJECT TITLE Peoples 1.1 DESIGN STRIP Support Line 4 Current_plane 2 - MEMBER ELEVATION [ft] 6.00 20.00 25.00 20.00 6.00 3 - TOP REBAR 3.1 User selected 3.2 User selected 3.3 ADAPT selected 3.4 ADAPT selected 1 8#4X8' 6" 2 15#4X11' 0" 3 9#4X11' 0" 4 9#4X5'6" 7 8#4X8' 6" 4 - TENDON PROFILE 4.2 Datum Line 4.3 CGS Distance [in] 4.5 Force 3.25 3.94 5.50 [296.448 kips] 5.50 1.75 5.50 [296.448 kips] 5.50 1.00 5.50 [296.448kips] 5.50 1.75 5.50 [296.448 ki ps] 5.503.94 3.25 [296.448kips] 5 - BOTTOM REBAR 5.1 User selected 5.2 User selected 5.3 ADAPT selected 5.4 ADAPT selected 5 12#4X13' 6" 6 11#4X9'6" 6 - REQUIRED & PROVIDED BARS 6.1 Top Bars [ in 2 ] required provided 6.2 Bottom Bars max max 0.0 1.8 3.6 2.3 4.6 1.46 0.00 2.85 0.00 2.77 4.56 3.46 0.00 1.46 0.00
(k) Reinforcement for each design strip is automatically selected by the program and displayed, specifying the location, number and length of bars. M_pictorial10.doc