Escolar Documentos
Profissional Documentos
Cultura Documentos
Overview
Auxiliaries Safety
Sensors Evaluation Unit Actuators
Pitch Yaw
Contactor Frequency Converter
MSS PLC
Turbine Control
Yaw Cooling
Extreme Requirements
Consulting
e .g. at Pitch
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 2 2013-10 Technical Concepts with Switchgears I IA CE S V
Controlling of Auxiliaries
Controlling of Auxiliaries Requirements SIRIUS System Compact Motor Starter Monitoring with IO-Link Extreme Requirements Safety Main Power Circuit Consulting for Panel Builders 3 4 5 6 8 11 17 23 28
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 3 2013-10 Technical Concepts with Switchgears I IA CE S V
Requirements e. g. Yaw
4 till 12 Motors
Turning of the nacelle has to be extreme reliable. Robust and despite of this cost efficient concepts are needed, which work 20 years for sure. Established technologies, which approved the reliability of operation are in demand here. Preserve mechanics and permanent monitoring of loads is needed for preventive maintenance.
Fast, easy and safe assembly thanks to spring-loaded connection system, infeed systems and function modules
18.5 kW on 45 mm width
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 5 2013-10 Technical Concepts with Switchgears I IA CE S V
Highlights
Compact Up to 15 kW (32 A at 400 V AC) Reliably CPS in IEC 60947-6-2 (Control & Protective Switching Device) Even at a short circuit: No welding of contacts Remote-Reset after a temporarily motor-overload possible (e.g. by software) Connection with spring-loaded terminals safe connection even at vibrations and extreme temperature changings Easy Less cabling simple installation
Technical Concept
45 mm
A Compact Starter combines functional switching, overload and short-circuit current protection Contactor, circuit breaker, overload relay
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 6 2013-10 Technical Concepts with Switchgears I IA CE S V
170 mm
PROFINET 400V ~ Optional: Soft Starter preserve mechanics Load Control current, voltage Limiter more shortcircuit current prevention ET200S
IO-Link
IO-Link
Compact Starter
Components
enclosed xls-File
YawMotors
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 7 2013-10 Technical Concepts with Switchgears I IA CE S V
ET200S
Topics
All operating data available (Current, Voltage, Load, Energy, Earth fault)
24V IO
IO-Link: 3 simple wires (signal, plus, minus) replaces many single wires and transfers extensive Data Compact & well proved standards Could similar be used for pumps, fans
...
Short Circuit Motor Protection Contactor Monitoring Relay: Overload, Energy IO-Link
Components
see enclosed xls-File Unrestricted / Siemens AG 2013. All Rights Reserved. Page 8 2013-10
Benefits, Summary
IO-Link Only one 3-wire-cable per 4-motors-groupe is needed to transfer all parameters. All data are available at the PLC e.g. controller SIMATIC S7 Diagnosis & preventive maintenance. Compact Starter Remote or auto reset possible. Variants enormous reduced: UL and IEC. Wide spread. Overload Class 10 or 20 Vibrations are no danger: With Cage Clamp technology you get a firm connection At each single motor the following parameters are monitored all the time: Switching status, end of service life, overload, short circuit and more Soft Starter Preserve mechanics and avoiding electric current peaks while starting of motors. Additional increasing of compact starters life-time (switching operations).
Extreme Requirements
Controlling of Auxiliaries Extreme Requirements Pitch 4 10 11
Short Circuit Case, 400...690V 13 Safety Main Power Circuit Consulting for Panel Builders 17 23 28
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 10 2013-10 Technical Concepts with Switchgears I IA CE S V
Pitch Extreme Requirements: Vibrations & Centrifugal Force Offshore & Salt-containig Air
In case of a network collapse, the rotor is able to reach the maximum speed and the contactors switch off even with maximum acceleration (up to 7*g)! Operation under radial acceleration is supported up to 70m/s (confirmed by comprehensive tests)!
Contactor
Confirmation Bestaetigung
enclosed dpf-File
These proven product characteristics distinguish Siemens from other and facilitate the industrial controls' safe application in wind turbines.
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 12 2013-10 Technical Concepts with Switchgears I IA CE S V
No transformer & Energy Saving Approved Switchgear Combinations for extreme Short Circuit Current
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 13 2013-10 Technical Concepts with Switchgears I IA CE S V
Breaker Limiter
Breaker
Diesel Generator
Lift
Service Power
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 14 2013-10 Technical Concepts with Switchgears I IA CE S V
Further Benefits
No 400 V- Transformer (only 230 V, PLC) much smaller cabinet Safe energy (e.g. 3% of all auxiliaries) Safe costs
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 15 2013-10 Technical Concepts with Switchgears I IA CE S V
Load Feeder
enclosed pdf-File
Safety
Controlling of Auxiliaries Extreme Requirements Safety Process Single Functions Overall Concept Main Power Circuit Consulting for Panel Builders 4 11 16 17 18 20 23 28
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 16 2013-10 Technical Concepts with Switchgears I IA CE S V
Process
Start End Yes
Hazard identification
Risk estimation
Risk evaluation
No
Risk reduction
Technical Concepts
Sensors Evaluation Unit Actuators
Pitch
Frequency Converter
Yaw
Contactor
MSS PLC
Turbine Control
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 17 2013-10 Technical Concepts with Switchgears I IA CE S V
400 V ~
Rotary Encoder Modular Safety System (MSS) Safety Relay 3SK1 Azimut Gear Wheel
PL c / d
CW CCW Rotating
direction
PL d
Yaw
Motors
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 18 2013-10 Technical Concepts with Switchgears I IA CE S V
Speed
Sensor
Srew Heads
Shock
e.g. in control cabinet 3SE5 MSS 3SK1
Pitch
Yaw
Ball in Ring
Shock Sensor
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 19 2013-10 Technical Concepts with Switchgears I IA CE S V
Cable Twisting
Shock Sensor
Safety Signals
Frequency Converter
Contactor
Pitch
Yaw
Turbine Control
Components
enclosed xls-File
Rotor Speed 1
Rotor Speed 2
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 20 2013-10 Technical Concepts with Switchgears I IA CE S V
High flexibility and reliability of planning: Modular design More space in the control cabinet and lower costs thanks to a highly modular quantity structure More functionality and time saving through a parameterizable software system Extensive diagnostics on site and project documentation using the MSS ES software
Simple thanks to a clear product portfolio and universal functionality Flexible thanks to a modular product concept and versatile parameterization Economical thanks to little variance and low wiring costs
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 21 2013-10 Technical Concepts with Switchgears I IA CE S V
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 22 2013-10 Technical Concepts with Switchgears I IA CE S V
Infeed panel
Transformer
Main power circuit (Converter)
Generator
Transformer
20 kV
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 23 2013-10 Technical Concepts with Switchgears I IA CE S V
Gear
ASG
Gear
ASG
Gear
SG
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 24 2013-10 Technical Concepts with Switchgears I IA CE S V
DFIG
Contactor
Circuit Breaker
Examples
2 Contactors 3RT14, 3 Contactors 3RT14, 3 Contactors 3TF69, each 690 A * 1,8 (Derating) = 1.200 A each 690 A * 2,5 (Derating) = 1.700 A each 910 A * 2,5 (Derating) = 2.300 A 1,6 MW Turbine 2,4 MW Turbine 3,0 MW Turbine
Components
enclosed xls-File
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 25 2013-10 Technical Concepts with Switchgears I IA CE S V
Converter
(sometimes several modules parallel)
Contactor
Circuit Breaker
Examples
3 Contactors 3RT14, each 690 A * 2,5 (Derating) = 1.700 A 3 Contactors 3TF69, each 910 A * 2,5 (Derating) = 2.300 A Contactors are used parallel at 690V, AC1 1,2 MW per Converter module 1,6 MW per Converter module
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 26 2013-10 Technical Concepts with Switchgears I IA CE S V
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 27 2013-10 Technical Concepts with Switchgears I IA CE S V
Unrestricted / Siemens AG 2013. All Rights Reserved. Page 29 2013-10 Technical Concepts with Switchgears I IA CE S V