Você está na página 1de 18

BG2 Range - MANUAL CALL POINT

Exed, Intrinsically Safe (Exia), Weatherproof Features


Zone 0, Zone 1 and Zone 2 use. Exed, Exia or weatherproof. ATEX approved Ex II 1G (Exia) Ex II 2G (Exed) BASEEFA certified. IP66 and IP67. Certified temperature: 40C to +50C*. Corrosion resistant red painted GRP . Retained stainless steel cover screws. Optional lift flap. Key operated test facility. Lightweight and robust. Breakglass hammer available. (Contact sales office for details)

*Depending on version.

Introduction
This manual fire alarm call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where lightweight combined with a high level of corrosion resistance is required.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS029/L

Specification
BG2W Protection: Certification: Dust-tight and Weatherproof Not Applicable BG2E Explosion Protected Exed (Increased Safety) CENELEC EN50014, 018, 019, 028 Cert. No. BAS02ATEX2105X ExedIICT6 (switch only) ExedmIICT4 (other versions) Suitable for use in Zones 1 & 2 American Bureau of Shipping Type Approval Up to 250V (Switch only) Up to 24V (Resistors & Switch) 20C to +50C IP66 & 67. BS 5839 : Part 2 : 1983 (BG). BG2I Explosion Protected Exia (Intrinsically Safe) CENELEC EN50014, 020 Cert. No. Baseefa03ATEX0084X Exia IIC T4 Suitable for use in Zones 0, 1 & 2

Voltage: Certified Temperature: Ingress Protection: British Standard for Call Points: Switch Ratings:

Up to 254V 40C to +55C IP66 & 67. BS 5839 : Part 2 : 1983 (BG).

Up to 28V (IS) 40C to +50C IP66 & 67. BS 5839 : Part 2 : 1983 (BG). NOT APPLICABLE 470R Minimum* 6 x 2.5mm2

d.c.: 0-30V 5A (resistive) or 3A (inductive) 30V-50V 1A resistive or inductive a.c.: 0-254V 5A resistive or inductive 100R Minimum* 6 x 2.5mm2 100R Minimum, 39k Maximum* 2 x M20 bottom. 6 x 2.5mm2 1.2 Kg. U.V. resistant glass reinforced polyester. Painted Red

Resistor Values: Cable Enries: Terminals: Weight: Material: Finish:

1. Switch Only

2. End of Line Resistor / Diode R1/D1

1 2 3 4 5 6

1 2 3 4 5 6

ALL CIRCUITS SHOWN WITH GLASS INTACT 3. In Line Resistor / Diode R2/D2 4. In Line & End of Line Resistor / Diode R1/D1 R2/D2 1 2 3 4 5 6
ALL DIMENSIONS IN MILLIMETERS

1 2 3 4 5 6

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. For standard products, available ex-stock, contact sales office for details.
Model Options Flap Finish

The MEDC BG Range of Manual Alarm Call Points caters for numerous options such as variety of colours, LED indication, earth continuity, double switch, etc. See separate catalogue sheet for details.

Model BG2W a.c. or d.c. BG2I Up to 28V (I.S.) BG2E d.c. BG2E a.c.

Code BG2WNN BG2INN BG2EDC BG2EAC

Options Code Switch only 1 End of line resistor 2* In line resistor 3* In line and end of line resistor 4* 5 Diode (specify location & value)
* Specify resistor values.

Flap Fitted Not Fitted

Code F* N

Finish Red Painted

Code R

* Polycarbonate lift flap.

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

BG3 Range - MANUAL CALL POINT

Intrinsically Safe (Exia), Weatherproof Features


Zone 0, Zone 1 and Zone 2 use. Exia IIC T4. ATEX Approved Ex II 1 G. BASEEFA certified. Chinese (CQST) certified. Designed in accordance with EN54-11. IP66 and IP67. Certified temperature: 55C to +55C. Corrosion free GRP . Optional in line/end of line resistors/diodes. Optional LED indicator. Optional lift flap. Key operated test facility. Various body colours available.

Introduction
This manual fire alarm call point has been designed in accordance with the latest draft European Call Point Standard (EN54-11). Weatherproof to IP66 and IP67 and available certified intrinsically safe, simple apparatus or uncertified. The units are manufactured from glass reinforced polyester (GRP) which provides a robust, corrosion free construction and ensures effective and reliable operation in harsh industrial and offshore environments. Units are supplied in natural red GRP or painted to customer specification. 'Burning House' duty label is provided as standard, other duty and tag labels may be supplied to customer specification.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS100/M

Specification
BG3I Protection: Certification: Explosion Protected Exi (Intrinsically Safe) CENELEC EN50014, 020 BASEEFA Exia IIC T4 Cert No. BAS00ATEX1067X Suitable for use in Zones 0, 1 & 2 Chinese Certification CQST Exia IIC T4 Up to 28V (IS) -55C to +55C IP66 & IP67 EN54-11 6 x 4.0mm2 Not Applicable BG3W Dust-tight & Weatherproof

Not applicable

Voltage: Certified Temperature: Ingress protection: European Standard for Call Points: Terminals: Switch Ratings:

Up to 250V a.c. Not applicable IP66 & IP67 EN54-11 6 x 4.0mm2 d.c. 0V - 30V 3A resistive or inductive 30V - 50V 1A resistive or inductive a.c. 0 - 250V 3A resistive or inductive 270R Minimum 2 x M20 top or bottom 0.5Kg UV resistant glass reinforced polyester Natural Red GRP or Painted GRP to Customer requirements Plastic as standard

Resistor Values: Cable Entries: Weight: Material: Finish: Duty/Tag Labels:

470R Minimum 2 x M20 top or bottom 0.5Kg UV resistant glass reinforced polyester Natural Red GRP or Painted GRP to Customer requirements Stainless steel as standard

ALL DIMENSIONS IN MILLIMETERS

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details.
Model BG3 Certification Weatherproof Exia Chinese (CQST) Code W I Q Label Code Glass Label Fire Break Glass 'Press Here' 1 Break Glass 'Press Here' 2 Special 3* European Standard 4 Duty Label (special) 5* Burning House as standard Tag Label
* Specify wording * Please specify

Certification

Labels

Options

Entries

Finish

Not suitable for use in China on fire alarm systems.

6*

Options None Resistor Series Resistor EOL Diode Polycarbonate Lift flap Stainless steel Lift flap LED Double Changeover Plastic Element
(replaces break glass)

Code N S* E* D F C L T P

Entries 2 x M20 (bottom) 2 x M20 (top)

Code B T

For blanking plugs add P to code. e.g. BP , 2 x M20 bottom entries with one blanking plug.

Finish Natural Red Blue Green White Yellow Special


* Please specify

Code R B G W Y S*

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

MANUAL CALL POINTS

Exed, Intrinsically Safe (Exia), Weatherproof BG Range & PB Range Features


Polyester enclosure light, strong and not subject to corrosion. 2 models: Breakglass. Pushbutton. 4 basic versions available: (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro]) (2) Explosion protected Exi (ATEX, GOST R, GOST K, Chinese (CQST), Brazilian [Inmetro] or CSA), (3) Explosion protected: Class I, Div. 2, Groups A-D Class II, Div. 2, Groups F & G (PB only) Class I, Zone 2 (4) Weatherproof & Dust-tight/UL ordinary locations. In line and end of line resistors and/or zener diodes can be fitted. Variety of colours available. Up to 9 terminals available. Lift flap available for extra protection against inadvertent operation. Optional LED this indicates that the unit has been operated useful for testing purposes. Earth continuity option for metal glands. 1 or 2 changeover switches. Captive cover screws. SIL 2 Certified.

Introduction
These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS067/S

Features
Breakglass Model No hammer required the glass is covered by a membrane thus protecting the operator from glass fragments. A plastic Break glass or deformable operating element is available to replace the break glass*. Once the flexible element is pressed it bends but will not break. The unit is reset by repositioning the element. All other functions remain the same. Complies with the British Standard for call points. Key operated test facility simple but secure. Breakglass hammer available.

Pushbutton Model Stayput as standard or self reset available. Lift Flap as standard. (Not turn and push model).

*Note: Deformable operating element does not comply with BS5839 Part 2.

Specification
Model: Protection: BGW & PBW Weatherproof/ dust proof Weatherproof/ dust proof IP66/IP67 *BGUL & PBUL Explosion Protected Class I, Div 2 Class II, Div 2 UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629 UL listed for ordinary locations Listing No. S8117 *Refer to UL data sheet at rear of catalogue for complete information BGE & PBE Explosion Protected Exed (Increased Safety) ATEX approved Ex II 2GD BAS02ATEX2105X (PB only) ATEX approved Ex II 2G BAS02ATEX2105X (BG only) Exed IICT6 (switch only) Exedm IICT4 (other versions) CENELEC EN50014 EN50019 EN50018 EN50028 Suitable for use in Zones 1 & 2 Chinese Certification (PBE & BGE): CQST Exed IIC T6 (switch only) Exedm IIC T4 (other versions) GOST R Certification (PBE & BGE): Exedm IIC T6 Exedm IIC T4 (other versions) Russian Fire Approved Brazilian (Inmetro) Certification: BR-Ex emd IIC T4 or BR-Ex ed IIC T6 SIL 2 Certification to 61508. Cert. No. Sira 11013 (BGE only). American Bureau of Shipping Type Approval BGE only BGI & PBI Explosion Protected Exia (Intrinsically Safe) ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only) ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only) Exia IIC T4 CENELEC EN50014 CENELEC EN50020 Suitable for use in Zones 0, 1 & 2 CSA Certification to C22.2 (PBI only): Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 79120 GOST R Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved GOST K Certification (PBI only): Exia IIC T4 Chinese Certification (PBI & BGI): CQST Exia IIC T4 Brazilian (Inmetro) Certification: BR-Ex ia IIC T4 American Bureau of Shipping Type Approval Voltage: Certified Temp: Up to 254V 40C to +55C Weatherproof Up to 240V 25C to +55C (PBUL) 25C to +55C (BGUL) UL Version Switch Ratings: (1 or 2 changeover switches fitted) Note: UL versions Max Rating 240VAC, 3A Material: Finish: British Standard for Call Points: Weight: Ingress Protection: Entries: Terminals: Anti static U.V. resistant glass reinforced polyester. Red painted finish as standard or to Customer specification. BS 5839 : Part 2 : 1983 (BG). 1.2 kg. (Varies with model & entries). IP66 & IP67. Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version). 6 x 2.5mm2 standard (BGUL only). 7 x 2.5mm2 standard. 9 x 2.5mm2 optional up to 60V only. Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100PBE/BGE, 470PBI/BGI). Internal & external earth continuity is provided via an optional earth plate. A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions. BG Glass label - reads either (1) Fire Break glass press here (2) Break glass press here (3) Worded to customer requirements. PB & BG Duty label - worded to customer requirements. Rivetted on. PB & BG Tag label - worded to customer requirements. Screwed on.
1 2 3 4 5 6 1 2 3 4 5 6 SW1

Certification:

Up to 250V 20C to +50C

Up to 28V (IS) ATEX/CENELEC 40C to +70C (PBI) ATEX/CENELEC 40C to +50C (BGI) CSA 50C to +40C (PBI only) NOT APPLICABLE

d.c. - 0-30v 5A (resistive) or 3A (inductive) 30-50 1A resistive or inductive a.c. - 0-254V 5A resistive or inductive

Basic single changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units.

SW1

SW2

Risistors & Diodest: Earth Continuity: LED Indication: Labels:

Basic double changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units.

For versions containing inline and end of line resistors or diodes, please specify your requirements.

ALL DIMENSIONS IN INCHES & MILLIMETERS

ALL DIMENSIONS IN MILLIMETERS

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details.
Model Certification Entries Labels Voltage Switches Options Terminals Finish

BG PB

Certification Code ATEX/CENELEC Ex ed EB ATEX/CENELEC Exi IB CSA Exi (PBI only) IC UL Listed UL UL - Ordinary locations UW GOST R Exi IG* GOST R Ex ed EG* GOST K Exi (PBI only) IK CQST Ex ed EQ CQST Exi IQ Inmetro Ex ed EM Inmetro Exi IM Uncertified WN
* Russian Fire Approved as standard. Not suitable for use in China on fire alarm systems

Entries M16 M20 1/2" NPT


*Prefix entry size (see diagram above) with entry position code e.g. 1A, 2A, 4B, 6B. UL & CSA versions only available with 1/2" NPT entries.

Code *A *B *C

Voltage a.c. d.c.

Code A D

Labels None Glass label (1) reqd. Glass label (2) reqd. Glass label (3) reqd. Duty label reqd. Tag label reqd.

Code 0 1 2 3* 4* 5*

Options Code None N LED A Lift Flap (BG only) B Resistor Series C* Resistor EOL D* Diode E Earth Continuity F** Turn & Push (PB only) T Self reset (PB only) M Resistor Series & EOL S* Plastic element replaces Break glass P
* Specify values Not available for UL/CSA versions. Choose for BGE or PBE only on BGI/W or PBI/W choose C & D ** Must be selected when selecting CSA certification

Finish Code Red (Standard) R Natural Black N Blue B Yellow Y Grey G Yellow/Black X Stripes Special S*
* Please specify

* Specify wording on 3, 4 or 5 as required.

Switches Single changeover Double changeover

Code S D

Terminals Code 6 x 2.5mm2 (standard) 6* 7 x 2.5mm2 (standard) 7 9 x 2.5mm2 (optional) 9


* BGUL only availablewith six terminals

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

MANUAL CALL POINTS

Exed, Intrinsically Safe (Exia), Weatherproof BG Range & PB Range Features


Polyester enclosure light, strong and not subject to corrosion. 2 models: Breakglass. Pushbutton. 4 basic versions available: (1) Explosion protected Exe (ATEX, Chinese [CQST],Brazilian [Inmetro]) (2) Explosion protected Exi (ATEX, GOST R, GOST K, Chinese (CQST), Brazilian [Inmetro] or CSA), (3) Explosion protected: Class I, Div. 2, Groups A-D Class II, Div. 2, Groups F & G (PB only) Class I, Zone 2 (4) Weatherproof & Dust-tight/UL ordinary locations. In line and end of line resistors and/or zener diodes can be fitted. Variety of colours available. Up to 9 terminals available. Lift flap available for extra protection against inadvertent operation. Optional LED this indicates that the unit has been operated useful for testing purposes. Earth continuity option for metal glands. 1 or 2 changeover switches. Captive cover screws. SIL 2 Certified.

Introduction
These manual fire alarm call points have been designed for use in hazardous locations and harsh environmental conditions. The GRP enclosures are suitable for use offshore or onshore, where lightweight combined with a high level of corrosion resistance is required.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS067/S

Features
Breakglass Model No hammer required the glass is covered by a membrane thus protecting the operator from glass fragments. A plastic Break glass or deformable operating element is available to replace the break glass*. Once the flexible element is pressed it bends but will not break. The unit is reset by repositioning the element. All other functions remain the same. Complies with the British Standard for call points. Key operated test facility simple but secure. Breakglass hammer available.

Pushbutton Model Stayput as standard or self reset available. Lift Flap as standard. (Not turn and push model).

*Note: Deformable operating element does not comply with BS5839 Part 2.

Specification
Model: Protection: BGW & PBW Weatherproof/ dust proof Weatherproof/ dust proof IP66/IP67 *BGUL & PBUL Explosion Protected Class I, Div 2 Class II, Div 2 UL Listed to Class I, Div 2, Groups A-D BGUL & PBUL Class II, Div 2, Groups F & G (PBUL only) Listing No. E186629 UL listed for ordinary locations Listing No. S8117 *Refer to UL data sheet at rear of catalogue for complete information BGE & PBE Explosion Protected Exed (Increased Safety) ATEX approved Ex II 2GD BAS02ATEX2105X (PB only) ATEX approved Ex II 2G BAS02ATEX2105X (BG only) Exed IICT6 (switch only) Exedm IICT4 (other versions) CENELEC EN50014 EN50019 EN50018 EN50028 Suitable for use in Zones 1 & 2 Chinese Certification (PBE & BGE): CQST Exed IIC T6 (switch only) Exedm IIC T4 (other versions) GOST R Certification (PBE & BGE): Exedm IIC T6 Exedm IIC T4 (other versions) Russian Fire Approved Brazilian (Inmetro) Certification: BR-Ex emd IIC T4 or BR-Ex ed IIC T6 SIL 2 Certification to 61508. Cert. No. Sira 11013 (BGE only). American Bureau of Shipping Type Approval BGE only BGI & PBI Explosion Protected Exia (Intrinsically Safe) ATEX approved Ex II 1GD Baseefa 03ATEX0084X (PB only) ATEX approved Ex II 1G Baseefa 03ATEX0084X (BG only) Exia IIC T4 CENELEC EN50014 CENELEC EN50020 Suitable for use in Zones 0, 1 & 2 CSA Certification to C22.2 (PBI only): Nos.0-M, 0.4-M, 14-M, 25, 30-M, 94, 142-M1987, 157-M1987, 157-92, Enclosure Type 4. T4A Class I Groups A, B, C & D Cert. No. 79120 GOST R Certification (PBI & BGI): Exia IIC T4 Russian Fire Approved GOST K Certification (PBI only): Exia IIC T4 Chinese Certification (PBI & BGI): CQST Exia IIC T4 Brazilian (Inmetro) Certification: BR-Ex ia IIC T4 American Bureau of Shipping Type Approval Voltage: Certified Temp: Up to 254V 40C to +55C Weatherproof Up to 240V 25C to +55C (PBUL) 25C to +55C (BGUL) UL Version Switch Ratings: (1 or 2 changeover switches fitted) Note: UL versions Max Rating 240VAC, 3A Material: Finish: British Standard for Call Points: Weight: Ingress Protection: Entries: Terminals: Anti static U.V. resistant glass reinforced polyester. Red painted finish as standard or to Customer specification. BS 5839 : Part 2 : 1983 (BG). 1.2 kg. (Varies with model & entries). IP66 & IP67. Up to 4 entries, M16 or M20 top and bottom (1/2" NPT available on UL version). 6 x 2.5mm2 standard (BGUL only). 7 x 2.5mm2 standard. 9 x 2.5mm2 optional up to 60V only. Various configurations available on versions up to 24V and all "IS" versions. (Minimum Resistor value 100PBE/BGE, 470PBI/BGI). Internal & external earth continuity is provided via an optional earth plate. A high intensity red LED can be fitted as an optional extra to indicate operation on versions up to 24V and all "IS" versions. BG Glass label - reads either (1) Fire Break glass press here (2) Break glass press here (3) Worded to customer requirements. PB & BG Duty label - worded to customer requirements. Rivetted on. PB & BG Tag label - worded to customer requirements. Screwed on.
1 2 3 4 5 6 1 2 3 4 5 6 SW1

Certification:

Up to 250V 20C to +50C

Up to 28V (IS) ATEX/CENELEC 40C to +70C (PBI) ATEX/CENELEC 40C to +50C (BGI) CSA 50C to +40C (PBI only) NOT APPLICABLE

d.c. - 0-30v 5A (resistive) or 3A (inductive) 30-50 1A resistive or inductive a.c. - 0-254V 5A resistive or inductive

Basic single changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units.

SW1

SW2

Risistors & Diodest: Earth Continuity: LED Indication: Labels:

Basic double changeover switch wiring diagram. Note: additional terminal as standard for ATEX/CENELEC units.

For versions containing inline and end of line resistors or diodes, please specify your requirements.

ALL DIMENSIONS IN INCHES & MILLIMETERS

ALL DIMENSIONS IN MILLIMETERS

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box. Standard products available ex-stock. Please visit www.coopermedc.com for further details.
Model Certification Entries Labels Voltage Switches Options Terminals Finish

BG PB

Certification Code ATEX/CENELEC Ex ed EB ATEX/CENELEC Exi IB CSA Exi (PBI only) IC UL Listed UL UL - Ordinary locations UW GOST R Exi IG* GOST R Ex ed EG* GOST K Exi (PBI only) IK CQST Ex ed EQ CQST Exi IQ Inmetro Ex ed EM Inmetro Exi IM Uncertified WN
* Russian Fire Approved as standard. Not suitable for use in China on fire alarm systems

Entries M16 M20 1/2" NPT


*Prefix entry size (see diagram above) with entry position code e.g. 1A, 2A, 4B, 6B. UL & CSA versions only available with 1/2" NPT entries.

Code *A *B *C

Voltage a.c. d.c.

Code A D

Labels None Glass label (1) reqd. Glass label (2) reqd. Glass label (3) reqd. Duty label reqd. Tag label reqd.

Code 0 1 2 3* 4* 5*

Options Code None N LED A Lift Flap (BG only) B Resistor Series C* Resistor EOL D* Diode E Earth Continuity F** Turn & Push (PB only) T Self reset (PB only) M Resistor Series & EOL S* Plastic element replaces Break glass P
* Specify values Not available for UL/CSA versions. Choose for BGE or PBE only on BGI/W or PBI/W choose C & D ** Must be selected when selecting CSA certification

Finish Code Red (Standard) R Natural Black N Blue B Yellow Y Grey G Yellow/Black X Stripes Special S*
* Please specify

* Specify wording on 3, 4 or 5 as required.

Switches Single changeover Double changeover

Code S D

Terminals Code 6 x 2.5mm2 (standard) 6* 7 x 2.5mm2 (standard) 7 9 x 2.5mm2 (optional) 9


* BGUL only availablewith six terminals

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

PH1 Range - PULL HANDLE CALL POINT

Exd, Weatherproof Features


Zone 1 and Zone 2 use. Ex d IIC T6 Gb Ex tb IIIC T85C Db IECEx certified Gb, Db ATEX certified Ex II 2 GD IP66 & 67 Certified temperature: -55C to +70C Corrosion free GRP construction Optional in line, end of line resistors and diodes Retained stainless steel cover screws

Introduction
The PH1 double action pull handle call point has been designed for use in flammable atmospheres and harsh environmental conditions. The GRP enclosure is suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS130/A

Specification
Certification: Certified to IEC60079-0, IEC60079-1 and IEC60079-31 Certified to EN60079-0, EN60079-1 and EN60079-31 IECEx Cert. No. IECEx ITS 11.0021X Atex Cert. No. ITS11ATEX17308X Ex II 2 GD Ex d IIC T6 Gb, Ex tb IIIC T85C Db Body/covers/handles:- GRP (glass reinforced polyester) Fixings:- Stainless steel grade 316 Cover:- natural red, Body:- natural black. Handles:- natural white. Cover may be painted to customer's requirements. 0-50Vdc, 0-254Vac. 1 or 2 c/o switches, 254V, 3A max. Gross weight 3.2Kg. Net weight 2.6Kg -55C to +70C. IP66 & 67. Up to 2 x M20 or M25, up to 2 x 1/2 or 3/4 NPT. 6 x 2.5mm2 as standard. Contact Cooper MEDC for options. Earth continuity is provided by internal plate. 'Burning house' label fitted as standard on red units. Blank label fitted as standard on all other colour units. Tag & Duty label options, worded to customers requirements. Consult Cooper MEDC for options. Various configurations available, 470 Ohms minimum. Various configurations available.

Material: Finish:

Voltage: Switch Rating: Weight: Certified Temp: Ingress Protection: Entries: Terminals: Earth Continuity: Labels:

Addr. module: Resistors: Diodes:

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring switch only

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring c/w EOL resistor


R1 - EOL Resitor

SINGLE SWITCH

DOUBLE SWITCH

Standard wiring c/w series resistor or series & EOL resistor


R1 - Series Resitor R2 - EOL Resitor (if fitted)
ALL DIMENSIONS IN MILLIMETRES

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box.
Model PH1 Certification ATEX IECEx Code B J Entries M20 M25 1/2" NPT 3/4" NPT Code *B *C *M *N Switches Single changeover Double changeover Code S D Features None Series resistor EOL resistor Diode Tag label Duty label
* Please specify

Certification

Entries

Switches

Features

Finish

* Prefix entry size with entry position (see diagram above). E.g. 4B6B. Maximum 2 Entries

Code N G* H* E* T* D*

Finish Natural Red Special


* Please specify

Code R S*

NOTE: the units can be internally wired to suit customers specifications. Please discuss your requirements with us.
All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

SM87 BG & PB Range - MANUAL CALL POINTS

Intrinsically Safe (Exia), Exd, Weatherproof Features


Zone 0, Zone 1 and Zone 2 use*. Exia IIC T4 or Exd IIC T5/T6. ATEX aproved, Ex II 1G (Exia) Ex II 2GD (Exd). BASEEFA certified UL Listed (PB only), Class I, Div 1, Groups C & D. CSA certified. IECEx certified Gb, Db. GOST R & K* certified. Chinese (CQST) certified. Brazilian (Inmetro) certified. IP66 and IP67. Certified temperature: 55C to +70C*. Stainless steel or marine grade alloy. Robust yet lightweight. Easy to maintain.
*Depending on version.

Introduction
These manual fire alarm, emergency shutdown breakglass and pushbutton units have been designed for the most arduous environmental conditions. The units are both easy to install and maintain. Intrinsically safe Exia and flameproof Exd versions of each model are available. A choice of either stainless steel or alloy makes the range suitable for either the offshore or onshore industries.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS015/O

Specification
Type: Breakglass unit, latching Lift flap, Breakglass, latching Push button, latching, key reset Push button, self reset Type SM87BGL Type SM87LBGL Type SM87PBL Type SM87PBM

Certification:

Ex d certified to IEC60079-0, IEC60079-1, IEC60079-31 Ex d certified to EN60079-0, EN60079-1, EN60079-31 Exia certified to IEC60079-0, IEC60079-11, IEC60079-26 Exia certified to EN60079-0, EN60079-11, EN60079-26 Ex d ATEX Cert. No. Baseefa03ATEX0075 Ex II 2 GD Ex d IIC T5/T6 Gb, Ex tb IIIC T85C/T100C Db Exia ATEX Cert. No. Baseefa02ATEX0152X Ex II 1 G Ex ia IIC T4 Ga Ex d IECEx Cert. No. IECEx BAS 09.0060 Ex d IIC T5/6 Gb, Ex tb T85C/T100C Db Exia IECEx Cert. No. IECEx BAS 10.0033X Exia IIC T4 Ga UL Listed: Class I, Div1 Groups C & D (PBL only). Listing No: 186629. CSA Certification: Class I Groups A-D I.S. version (SM87 PBI only). Class I, Div 1 & 2, Group D (Exd SM87 PB & SM87 BG). GOST R Certification: 1Exib IIC T4, 1Exd IIC T4 Russian Fire Approval GOST K Certification: Exib IIC T4. Chinese Certification: CQST Exia IIC T4, Exd IIC T5/T6. Brazilian (Inmetro) Certification: BR-Ex d IIC T5/T6, BR-Ex ia IIC T4 Grade 316 ANC4B Stainless Steel or LM 25 TF Marine Grade Alloy. Paint finish as standard or to customer specification. Exd 24V a.c./d.c. Exia 28V. 2 amp.
ALL DIMENSIONS IN MILLIMETERS

Material: Finish: Voltage: Rating: Switches

2 pole c/o, wired to terminals. Optional up to 4 pole (UL version 2 pole only). Exd*55C to +70C. Exi*55C to +55C. 20C to +55C (LED version only). UL 55C to +70C, 20C to +55C (LED version only). CSA 50C to +55C (Exd), 50C to +40C (Exi). *Note: includes ATEX, IECEx, GOST, Brazilian & Chinese versions. 38 kg. steel (approx.) or 2.5 kg. alloy (approx.). Both the Exia units and the Exd units have the same external appearance. Also the internal components are identical throughout the range. Each unit can be wired for either NO, NC or CO contacts to customer specification. Entries: Terminals: Resistor Values: Up to 4 x M20 or M25 ISO Exd/Exia. Up to 4 x 1/2" or 3/4" NPT UL Will accept up to 25mm2 cable. 470R minimum (d.c. & I.S. units only).

Optional Indicator: A red high intensity LED can be fitted for alarm indication. Certified Temp:

Weight:

Ingress Protection: IP66 and IP67. SM87 PB IP68 (40m for 8 hours).

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box.
Unit SM87 *Model Code Breakglass Latching BGL Lift Flap Breakglass Latching LBGL Push Button Latching key reset PBL Push Button Only PBM Momentary Action
* UL version only available in PBL model.

Model

Material

Certification

Entries

Duty Label

Tag Label

Options

Finish

*Material Code Stainless Steel S Alloy A


* UL version only available in Alloy.

Certification Exia Exd IECEx Exi IECEx Exd UL CSA Exi CSA Exd GOST K Exi GOST R Exi GOST R Exd Chinese Exi Chinese Exd Inmetro Exi Inmetro Exd

Code I D IJ DJ UL IC DC IK IG* DG* IQ DQ IM DM

Entries M20 M25 1/2" NPT 3/4" NPT Other Position Top Bottom RHS LHS

Code 1 2 3 4 5

Duty Label Code Fire-Breakglass 1 Push Button 2 Fire-Push Button 3 ESDO-Abandon 4 Other O* None N
* Please specify

*T *B *R *L

Options Code Not required N LED A Resistor Series G* Resistor EOL H* Diode D* 3 Pole T c/o Switch 4 Pole F c/o Switch Other O*
* Please specify

Finish Code Red R Blue B Yellow Y Yellow/ X Black Stripes Special S*


* Please specify

* Prefix position with size code i.e. 1T 1B = 20mm Top and Bottom.

* Russian Fire Approval as standard. Not suitable for use in China on fire alarm systems

Label Code Required Y* Not Required N


* Please specify

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

SM87 BG & PB Range - MANUAL CALL POINTS

Intrinsically Safe (Exia), Exd, Weatherproof Features


Zone 0, Zone 1 and Zone 2 use*. Exia IIC T4 or Exd IIC T5/T6. ATEX aproved, Ex II 1G (Exia) Ex II 2GD (Exd). BASEEFA certified UL Listed (PB only), Class I, Div 1, Groups C & D. CSA certified. IECEx certified Gb, Db. GOST R & K* certified. Chinese (CQST) certified. Brazilian (Inmetro) certified. IP66 and IP67. Certified temperature: 55C to +70C*. Stainless steel or marine grade alloy. Robust yet lightweight. Easy to maintain.
*Depending on version.

Introduction
These manual fire alarm, emergency shutdown breakglass and pushbutton units have been designed for the most arduous environmental conditions. The units are both easy to install and maintain. Intrinsically safe Exia and flameproof Exd versions of each model are available. A choice of either stainless steel or alloy makes the range suitable for either the offshore or onshore industries.

Cooper MEDC Limited, Colliery Road, Pinxton, Nottingham NG16 6JF, UK.

Cooper MEDC (USA) 3413 North Sam Houston Parkway West Suite 212 Houston, TX 77086, USA

Sales Enq. UK: +44 (0)1773 864 100

Sales Enq. USA: +1 (713) 937- 9772

E-Mail: medc.sales@cooperindustries.com Web: www.coopermedc.com


6DS015/O

Specification
Type: Breakglass unit, latching Lift flap, Breakglass, latching Push button, latching, key reset Push button, self reset Type SM87BGL Type SM87LBGL Type SM87PBL Type SM87PBM

Certification:

Ex d certified to IEC60079-0, IEC60079-1, IEC60079-31 Ex d certified to EN60079-0, EN60079-1, EN60079-31 Exia certified to IEC60079-0, IEC60079-11, IEC60079-26 Exia certified to EN60079-0, EN60079-11, EN60079-26 Ex d ATEX Cert. No. Baseefa03ATEX0075 Ex II 2 GD Ex d IIC T5/T6 Gb, Ex tb IIIC T85C/T100C Db Exia ATEX Cert. No. Baseefa02ATEX0152X Ex II 1 G Ex ia IIC T4 Ga Ex d IECEx Cert. No. IECEx BAS 09.0060 Ex d IIC T5/6 Gb, Ex tb T85C/T100C Db Exia IECEx Cert. No. IECEx BAS 10.0033X Exia IIC T4 Ga UL Listed: Class I, Div1 Groups C & D (PBL only). Listing No: 186629. CSA Certification: Class I Groups A-D I.S. version (SM87 PBI only). Class I, Div 1 & 2, Group D (Exd SM87 PB & SM87 BG). GOST R Certification: 1Exib IIC T4, 1Exd IIC T4 Russian Fire Approval GOST K Certification: Exib IIC T4. Chinese Certification: CQST Exia IIC T4, Exd IIC T5/T6. Brazilian (Inmetro) Certification: BR-Ex d IIC T5/T6, BR-Ex ia IIC T4 Grade 316 ANC4B Stainless Steel or LM 25 TF Marine Grade Alloy. Paint finish as standard or to customer specification. Exd 24V a.c./d.c. Exia 28V. 2 amp.
ALL DIMENSIONS IN MILLIMETERS

Material: Finish: Voltage: Rating: Switches

2 pole c/o, wired to terminals. Optional up to 4 pole (UL version 2 pole only). Exd*55C to +70C. Exi*55C to +55C. 20C to +55C (LED version only). UL 55C to +70C, 20C to +55C (LED version only). CSA 50C to +55C (Exd), 50C to +40C (Exi). *Note: includes ATEX, IECEx, GOST, Brazilian & Chinese versions. 38 kg. steel (approx.) or 2.5 kg. alloy (approx.). Both the Exia units and the Exd units have the same external appearance. Also the internal components are identical throughout the range. Each unit can be wired for either NO, NC or CO contacts to customer specification. Entries: Terminals: Resistor Values: Up to 4 x M20 or M25 ISO Exd/Exia. Up to 4 x 1/2" or 3/4" NPT UL Will accept up to 25mm2 cable. 470R minimum (d.c. & I.S. units only).

Optional Indicator: A red high intensity LED can be fitted for alarm indication. Certified Temp:

Weight:

Ingress Protection: IP66 and IP67. SM87 PB IP68 (40m for 8 hours).

Ordering Requirements
The following code is designed to help in selection of the correct unit. Build up the reference number by inserting the code for each component into the appropriate box.
Unit SM87 *Model Code Breakglass Latching BGL Lift Flap Breakglass Latching LBGL Push Button Latching key reset PBL Push Button Only PBM Momentary Action
* UL version only available in PBL model.

Model

Material

Certification

Entries

Duty Label

Tag Label

Options

Finish

*Material Code Stainless Steel S Alloy A


* UL version only available in Alloy.

Certification Exia Exd IECEx Exi IECEx Exd UL CSA Exi CSA Exd GOST K Exi GOST R Exi GOST R Exd Chinese Exi Chinese Exd Inmetro Exi Inmetro Exd

Code I D IJ DJ UL IC DC IK IG* DG* IQ DQ IM DM

Entries M20 M25 1/2" NPT 3/4" NPT Other Position Top Bottom RHS LHS

Code 1 2 3 4 5

Duty Label Code Fire-Breakglass 1 Push Button 2 Fire-Push Button 3 ESDO-Abandon 4 Other O* None N
* Please specify

*T *B *R *L

Options Code Not required N LED A Resistor Series G* Resistor EOL H* Diode D* 3 Pole T c/o Switch 4 Pole F c/o Switch Other O*
* Please specify

Finish Code Red R Blue B Yellow Y Yellow/ X Black Stripes Special S*


* Please specify

* Prefix position with size code i.e. 1T 1B = 20mm Top and Bottom.

* Russian Fire Approval as standard. Not suitable for use in China on fire alarm systems

Label Code Required Y* Not Required N


* Please specify

All the above specifications, dimensions, weights and tolerances are nominal (typical) and Cooper MEDC reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use.

02/12

Você também pode gostar