Você está na página 1de 2

COOLING TOWER MOTORS

INTRODUCTION

RANGE

HINDUSTAN Cooling tower motors are specially


designed flange mounted motors in totally enclosed
construction to suit air conditioning & refrigeration
industries. They are provided with special long shaft
construction with external threaded end to directly mount
the fan blades. This also helps in the better cooling of the
motor. Motors are compact in design & less in weight to
facilitate easy maintenance. They are available as
standard catalogue designs or as custom built.

Power :
0.37 to 22.0 kW
Polarity :
4P, 6P, 8P, 10P & 12P
Mounting : B5 flange mounted
Frame size : 71 to 280
Voltage :
415V 10% or as required
Frequency : 50Hz 5% or as required
Ambient :
45C.
Altitude :
upto 1000m above m. s. l.
Enclosure : Totally enclosed (TE)
Protection : IP55
Insu. class : Class F insulation with temp.
rise limited to class B.

MECHANICAL DIMENSIONS

Frame

D1

D2

D3

GA

L1

L2

71
80
90S
90L
100L
112M
132S
132M
160M
160L
180M
180L
200L
225MX
250MX
280MX

15
20
25
25
30
30
40
40
45
45
50
50
60
65
75
85

14
19
24
24
28
28
38
38
42
42
48
48
55
60
65
75

M12
M16
M16
M16
M24
M24
M30
M30
M30
M30
M30
M30
M30
M30
M36
M36

5
6
8
8
8
8
10
10
12
12
14
14
16
18
18
20

11
15.5
20
20
24
24
33
33
37
37
42.5
42.5
49
53
58
68

16
21.5
27
27
31
31
41
41
45
45
51.5
51.5
59
64
69
80

50
50
50
50
50
50
75
75
75
75
100
100
100
100
100
100

40
55
55
55
55
55
75
75
75
75
120
120
120
120
120
120

155
170
170
170
170
170
215
215
215
215
285
285
285
285
285
285

P
max
160
200
200
200
250
250
300
300
350
350
350
350
400
450
550
550

M
PCD
130
165
165
165
215
215
265
265
300
300
300
300
350
400
500
500

110
130
130
130
180
180
230
230
250
250
250
250
300
350
450
450

10
12
12
12
15
15
15
15
19
19
19
19
19
19
24
24

Z
No.
4
4
4
4
4
4
4
4
4
4
4
4
4
8
8
8

LA

3.5
3.5
3.5
3.5
4
4
4
4
5
5
5
5
5
5
5
5

9
10
10
10
11
11
12
12
13
13
13
13
15
16
18
18

35
45
45
45
45
45
65
65
65
65
110
110
110
110
110
110

331
368
380
405
432
446
515
553
614
658
727
765
846
850
920
1025

Electrical performance for Cooling Tower 3 Phase Sq. cage induction motors suitable for 415V10%, 50Hz5%,
ambient temperature 45C, Class 'F' insulation with class B temp. rise, IP 55 protection, totally enclosed (TE)
construction, continuous (S1) duty.
Output
KW

HP

0.37
0.75

0.50
1.0

1.1

1.5

1.5

2.0

2.2

3.0

3.7

5.0

5.5

7.5

7.5

10.0

9.3

12.5

11.0

15.0

15.0

20.0

18.5

25.0

22.0

30.0

Frame

Type
Designation

71
80
90S
90S
90L
100L
132S
90L
100L
112M
132S
132M
112M
132S
132M
160M
132S
132M
160M
160L
132M
160M
180M
180L
160M
160L
180L
180L
160L
180M
180L
180L
160L
180L
180L
200L
200L
200L
225MX
225MX
250MX
280MX

2HL1 713-04
2HL1 803-04
2HL1 900-06
2HL1 900-04
2HL1 906-06
2HL1 106-08
2HL1 130-12
2HL1 906-04
2HL1 106-06
2HL1 123-08
2HL1 130-10
2HL1 133-12
2HL1 123-06
2HL1 130-08
2HL1 133-10
2HL1 163-12
2HL1 130-06
2HL1 133-08
2HL1 163-10
2HL1 166-12
2HL1 133-06
2HL1 163-08
2HL1 183-10
2HL1 186-12
2HL1 163-06
2HL1 166-08
2HL1 186-10
2HL1 187-12
2HL1 166-06
2HL1 183-08
2HL1 187-10
2HL1 188-12
2HL1 167-06
2HL1 186-08
2HL1 188-10
2HL1 206-12
2HL1 206-08
2HL1 206-10
2HL1 223-12
2HL1 223-10
2HL1 253-12
2HL1 283-12

Speed Current Torque


(kgm)
(rpm)
(A)
1380
1415
925
1415
930
700
460
1420
940
705
555
460
945
710
555
465
950
710
560
465
950
720
560
470
960
720
565
470
965
725
570
470
970
725
570
485
725
575
480
575
485
485

1.05
1.75
2.0
2.5
2.9
3.0
3.8
3.3
3.5
3.9
4.5
4.9
4.9
5.2
5.7
6.0
7.5
8.6
9.0
10.0
11.0
12.0
14.0
15.0
15.0
15.7
18.0
20.0
17.5
20.0
22.0
23.0
20.5
24.0
25.0
33.0
31.0
34.0
40.0
43.0
54.0
56.0

0.26
0.52
0.79
0.76
1.15
1.53
2.33
1.03
1.55
2.07
2.63
3.18
2.27
3.02
3.86
4.61
3.79
5.08
6.44
7.75
5.64
7.44
9.57
11.40
7.61
10.15
12.93
15.54
9.39
12.49
15.89
19.27
11.05
14.78
18.80
22.09
20.15
25.41
30.44
31.34
37.15
44.18

Efficiency %

Power Factor

FL

3/4L

1/2L

FL

3/4L

1/2L

66.0
74.0
72.0
76.5
75.0
74.0
70.0
79.0
76.0
77.0
74.0
71.0
80.0
79.0
78.0
79.0
82.5
81.0
81.0
80.0
85.0
86.0
82.0
82.0
87.0
87.0
83.0
82.0
88.0
87.5
84.0
84.0
88.5
88.0
85.0
84.5
88.5
86.5
85.5
89.0
86.5
89.0

65.0
73.0
71.0
76.0
74.0
73.0
68.0
79.0
75.0
77.0
74.0
70.0
79.5
79.0
78.0
79.0
82.5
81.0
81.0
80.0
85.0
86.0
81.5
82.0
87.0
87.0
82.5
82.0
88.0
87.5
83.5
84.0
88.5
88.0
85.0
84.0
88.0
86.0
85.5
89.0
86.0
89.0

58.0
68.0
66.0
74.0
69.0
71.0
64.0
77.0
71.0
74.0
71.0
66.0
75.5
76.0
76.0
75.0
81.5
79.0
79.0
77.0
83.5
83.0
80.0
80.0
84.5
85.0
80.0
80.0
85.0
85.0
81.0
82.0
87.5
85.0
83.0
81.0
86.0
84.0
83.5
87.0
82.0
87.0

0.74
0.81
0.72
0.80
0.70
0.69
0.58
0.80
0.78
0.69
0.63
0.60
0.78
0.75
0.69
0.65
0.83
0.74
0.71
0.64
0.82
0.74
0.67
0.62
0.80
0.76
0.70
0.64
0.84
0.74
0.70
0.67
0.84
0.72
0.72
0.55
0.76
0.71
0.61
0.67
0.55
0.61

0.64
0.70
0.64
0.70
0.58
0.60
0.50
0.70
0.73
0.64
0.55
0.52
0.70
0.65
0.61
0.54
0.73
0.65
0.62
0.55
0.77
0.68
0.58
0.54
0.76
0.71
0.62
0.55
0.81
0.70
0.62
0.59
0.81
0.68
0.64
0.47
0.72
0.63
0.54
0.60
0.48
0.54

0.53
0.55
0.52
0.55
0.42
0.48
0.40
0.55
0.60
0.51
0.43
0.42
0.55
0.52
0.49
0.45
0.64
0.52
0.50
0.42
0.67
0.58
0.45
0.42
0.68
0.58
0.48
0.43
0.70
0.57
0.49
0.46
0.70
0.55
0.50
0.38
0.60
0.52
0.43
0.50
0.37
0.44

STA

STT

POT

GD
(kgm)

3.5
4.5
5.0
5.0
5.0
4.0
3.5
5.0
5.0
4.0
4.5
3.5
5.0
5.0
4.5
4.5
5.0
5.0
5.0
4.5
5.0
5.0
5.0
4.5
5.5
5.0
5.0
4.5
5.5
5.0
5.0
4.5
5.5
5.0
5.0
4.5
5.0
4.5
4.0
4.0
4.0
4.0

1.9
2.0
2.2
2.2
2.2
1.8
1.7
2.2
2.0
1.9
2.0
1.7
2.0
2.2
2.0
2.0
2.0
2.2
2.1
2.0
2.0
2.0
2.0
1.9
2.0
2.0
2.0
1.9
2.0
2.0
2.0
1.9
2.0
2.0
2.0
1.9
2.0
2.0
1.8
2.0
1.9
1.8

2.1
2.3
2.4
2.5
2.4
2.0
1.9
2.5
2.3
2.1
2.2
1.9
2.3
2.4
2.2
2.2
2.3
2.4
2.3
2.2
2.3
2.2
2.2
2.1
2.3
2.2
2.2
2.1
2.3
2.2
2.2
2.1
2.3
2.2
2.2
2.1
2.2
2.2
2.0
2.2
2.1
2.0

0.0022
0.0049
0.0095
0.0072
0.0122
0.0296
0.0826
0.0093
0.0269
0.0467
0.0826
0.1198
0.0047
0.0826
0.1198
0.2072
0.0826
0.1156
0.2072
0.2857
0.1156
0.2565
0.5057
0.5949
0.2625
0.3440
0.5949
0.6544
0.3440
0.5057
0.6544
0.7734
0.3440
0.5949
0.7734
1.2654
1.0123
1.2654
1.8378
1.8378
2.5127
5.2502

All figures are subject to tolerance as per IS: 325.


All the above ratings can be offered in flameproof enclosure wherever applicable

Authorised Dealer:

Admin. Office:
P.O. Box 18701, 32/A, Vidyavilla Comp., Old Nagardas Road,
Andheri (East), Mumbai - 400069.
Tel: 2838 0080, 2838 0081, 2836 0651, 2820 1316
Fax: 022 - 2838 0947. Email: sales @hindmotors.com
Website: www.hindmotors.com

Design & specifications are subject to change without prior notice.

Cat: T01
Print: 01/2006

Você também pode gostar