Você está na página 1de 5

Page 1 of 6

Digital modules

SM 321 digital input module

Overview

Digital inputs For connecting standard switches and two-wire proximity switches (BERO)

Area of application Digital input modules can be used to connect the PLC to digital process signals. They are suitable for connecting standard switches and two-wire proximity switches (BERO). Design Digital input modules feature the following mechanical characteristics:

Compact design: The rugged plastic housing contains: Green LEDs for indicating the signal status at the inputs. Socket for the front connector, protected, behind the front door. Labeling field on the front door. Easy installation: There are no slot rules, the addresses of the inputs are determined by the slot. When used in ET 200M in combination with active bus modules, hot swapping is possible. User-friendly wiring.

The modules are available with 8, 16, 32, or 64 channels. Functions Digital input modules convert the level of the external digital signals from the process to the internal signal level of the controller. Various input voltages support the connection of different process signals:

24 V DC 48 to 125 V DC 120/230V AC For use in isochronous mode Process and diagnostic alarms Use for current sourcing or current sinking

Apart from cost-effective, easy-to-handle modules, modules with special functions are also available:

Special modules are also available for process engineering which, for example, support the NAMUR standard. Technical specifications
Supply voltages Load voltage L+ Rated value (DC) Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Current consumption/power loss Power loss, typ. Connection point 6ES7 321-1BH020AA0 24V 25mA 10mA 3.5W 6ES7 321-1BH500AA0 24V 10mA 3.5W 6ES7 321-1BL000AA0 24V 15mA 6.5W 6ES7 321-1BP000AA0 24V 100mA 7W 6ES7 321-1BH100AA0 24V 110mA 3.8W

Page 2 of 6

required front connectors

20-pin

20-pin

40-pin

Cable: 6ES7 3924Bxx0-0AA0 terminal blocks: 6ES7 392-1xN000AA0 No 64 64 32 32 Yes 24V -30...5 13...30 4.2mA; typical No 1.2ms 4.8ms 1000m 600m No

20-pin

Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs horizontal installation up to 40 C, max. up to 60 C, max. vertical installation up to 40 C, max. Input characteristic curve to IEC 1131, Typ 1 Input voltage Rated value, DC for signal "0" for signal "1" Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs programmable at " to "1", min. at "0" to "1", max. Cable length cable length, shielded, max.

No 16 16 16 Yes 24V -30 to +5 V 13 to 30 V 7mA 1.2ms 4.8ms 1000m

No 16 16 16 Yes 24V -5 to +30 V -13 to -30 V 7mA 1.2ms 4.8ms 1000m 600m Yes 1.5mA

No 32 32 16 32 Yes 24V -30 to +5 V 13 to 30 V 7mA 1.2ms 4.8ms 1000m 600m Yes 1.5mA

Yes 16 16 16 Yes 24V -30 to +5 V 13 to 30 V 7mA 25s 75s 1000m 600m Yes 1.5mA

Cable length unshielded, 600m max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Yes 1.5mA

Status information/alarms/diagnostics Alarms Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus No No Yes 500 VDC No 16 Yes; Optocoupler

No No Yes 500 VDC No 16 Yes; Optocoupler

No No Yes 500 VDC No 16 Yes; Optocoupler

No No No No Yes 500 VDC No 16 Yes

No No Yes 500 VDC No 16 Yes; Optocoupler

Page 3 of 6

Dimensions Dimensions Width Height Depth Weights Weight, approx.

40mm 125mm 120mm 200g

40mm 125mm 120mm 200g

40mm 125mm 120mm 260g

40mm 125mm 112mm 230g; approx.

40mm 125mm 120mm 200g

Supply voltages Load voltage L+ Rated value (DC) Load voltage L1 Rated value (AC)

6ES7 321-7BH01-0AB0 24V

6ES7 321-1CH00-0AA0 24V 24V

6ES7 321-1CH20-0AA0 48V

6ES7 321-1FH00-0AA0 230V; 120/230 V AC; all load voltages must have the same phase. 29mA 4.9W 20-pin No 16 16 16 Yes 230V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz 6.5mA; (120V, 60Hz), 16mA (230V, 50Hz) No 25ms 1000m

Current consumption from load voltage L+ (without load), max. from backplane bus DC 5 V, max. Current consumption/power loss Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs horizontal installation up to 50 C, max. up to 60 C, max. vertical installation up to 40 C, max. Input characteristic curve to IEC 1131, Typ 1 Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, AC Rated value, DC for signal "0" for signal "1" Frequency range Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs programmable at " to "1", min. at "0" to "1", max. Cable length cable length, shielded,

90mA 130mA 4W 20-pin Yes 16 16 16 Yes 24V -30 to +5 V 13 to 30 V 7mA Yes; 0.1 / 0.5 / 3 / 15 / 20 ms 1000m

100mA 1.5W; at 24 V; 2,8 W at 48 V 40-pin No 16 16 16 Yes 24V; AC 24 or 48 V 24V; DC 24 or 48 V -5 to +5 V AC 14 to 60 V AC 0 to 63 Hz 2.7mA No 16ms 1000m

40mA 4.3W 20-pin No 16 8 8; 6 to Ue 146 V 8 Yes 48V; DC 48 to 125 V -146 to +15 V DC 30 to 146 V DC 3.5mA 0.1ms 3.5ms 1000m

Page 4 of 6

max. Cable length unshielded, 600m max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Yes 2mA 600m Yes 1mA 600m Yes 1mA 600m Yes 2mA

Status information/alarms/diagnostics Alarms Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostics indication LED Status indicator digital input (green) Isolation Isolation checked with Isolation Galvanic isolation, digital inputs between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. Yes Yes; Parameterizable Yes; parameterizable Yes; parameterizable Yes 500 VDC No 16 Yes; Optocoupler 40mm 125mm 120mm 200g

No No No No Yes 1500 V AC Yes 1 Yes; Optocoupler 40mm 125mm 120mm 260g

No No No No Yes 1500 V DC No 8 Yes; Optocoupler 40mm 125mm 120mm 200g

No No No No Yes 4000 VDC No 4 Yes; Optocoupler 40mm 125mm 120mm 240g

Supply voltages Load voltage L1 Rated value (AC)

6ES7 321-1EL00-0AA0 120V

6ES7 321-1FF01-0AA0 230V; 120/230 V AC

6ES7 321-1FF10-0AA0 230V; 120/230 V AC; all load voltages must have the same phase. 100mA 4.9W 40-pin No 8 8

Current consumption from backplane bus DC 5 V, max. Power loss, typ. Connection point required front connectors Isochronous mode Isochronouos mode Digital inputs Number of digital inputs Number of simultanneously controllable inputs horizontal installation up to 40 C, max. up to 60 C, max.

16mA

29mA 4.9W 20-pin No 8 8

Current consumption/power loss 4W 40-pin No 32 32 24

Page 5 of 6

vertical installation up to 40 C, max. Input characteristic curve to IEC 1131, Typ 1 Input characteristic curve to IEC 1131, Typ 2 Input voltage Rated value, AC for signal "0" for signal "1" Frequency range Input current for signal "1", typ. Input delay (for rated value of input voltage) for standard inputs programmable at "0" to "1", max. Cable length cable length, shielded, max. Cable length unshielded, max. Encoder Connectable encoders 2-wire BEROS permissible quiescent current (2-wire BEROS), max. Status information/alarms/diagnostics Alarms Alarms Diagnostic alarm Process alarm Diagnoses Diagnostic functions Diagnostics indication LED

32 Yes 120V 0 to 20 V 74 to 132 V 47 to 63 Hz 21mA No 15ms 1000m 600m Yes 4mA

8 Yes 230V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz 6.5mA; (120 V); 11mA (230 V) No 25ms 1000m 600m Yes 2mA

8 Yes 120V; 120/230 V AC 0 to 40 V 79 to 264 V 47 to 63 Hz 7.5mA; (120 V); 17.3 mA (230 V) No 25ms 1000m 600m Yes 2mA

No No No No

No No No No Yes 4000 VDC No 2 Yes; Optocoupler 40mm 125mm 120mm 240g

No No No No Yes 1500 VAC Yes 1 Yes; Optocoupler 40mm 125mm 120mm 240g

Status indicator digital input Yes; Per channel (green) Isolation Isolation checked with Isolation between the channels between the channels, in groups of between the channels and the backplane bus Dimensions Dimensions Width Height Depth Weights Weight, approx. 2500 V DC No 8 Yes; Optocoupler 40mm 125mm 120mm 300g

Galvanic isolation, digital inputs