Você está na página 1de 2

DIAMETER-WISE RECOMMENDED

FISCHER ANCHOR PROPERTIES

NOTES
1)
2)
3)
4)
5)

Load values for concrete grade M25. For different concrete grades use influencing factors as in handbook.
Load values on Single Anchor - ie characteristic axial spacing & edge distance.
For anchor row, reduction factors for spacings & edge distances between Characteristic value & Minimum value are given in Handbook
Price of any one diameter depends on the length of the anchor - as required for different base plate thicknesses
Loads are for galvanizedanchors.

Dia

Description

Recommended tension
load (KN)

Recommended Shear
Load (KN)

Effective
Anchorage
depth

Characteristic
axial spacing

Minimum
Axial
Spacing

Characteristic
Edge Distance

Minimum
Edge
Distance

Minimum
thickness
of member

List Price range as per


anchorlength for diff.
baseplate thickness
requirements
min.length
max.length

Un-cracked
zone
1.5
3.6

cracked
zone
-

Un-cracked
zone
3.6

cracked
zone
-

25.0
40.0

75.0
120.0

25.0
40.0

40.0
60.0

25.0
35.0

100.0
100.0

3.90
23.70

27.40

6
6

EA M6
FBN 6

8
8
8
8

EA M8
FAZ II 8
FBN II 8
RG M8

3.0
5.1
6.1
8.3

4.3
-

10.0
6.1
5.4

10.0
-

30.0
45.0
40.0
80.0

90.0
140.0
106.0
160.0

30.0
40.0
40.0
40.0

45.0
70.0
53.0
80.0

30.0
40.0
40.0
40.0

100.0
100.0
100.0
130.0

5.15
38.70
25.70
36.50

54.00
32.75
50.00

10
10
10
10
10
10

EA M10
FZA 10 M6
FH 10 B
FAZ II 10
FBN II 10
RG M10

4.5
6.7
6.8
8.4
8.5
11.7

4.3
3.8
6.7
-

4.6
7.7
16.0
8.5
8.6

4.6
6.1
16.0
-

40.0
40.0
50.0
60.0
50.0
90.0

120.0
120.0
150.0
180.0
126.0
180.0

40.0
40.0
50.0
40.0
50.0
45.0

60.0
60.0
75.0
90.0
63.0
90.0

40.0
35.0
50.0
45.0
50.0
45.0

120.0
100.0
100.0
120.0
100.0
140.0

6.90
66.90
70.40
57.25
24.50
47.10

110.00
78.40
38.00
103.00

12
12
12
12
12
12

EA M12
FZA 12 M8
FH II 12 S
FBN II 12
FAZ II 12
RG M12

6.5
6.7
11.2
12.6
12.7
17.2

4.3
7.0
9.5
-

7.2
14.3
11.8
23.4
12.5

5.6
14.3
23.4
-

50.0
40.0
60.0
65.0
70.0
110.0

150.0
120.0
180.0
150.0
210.0
220.0

50.0
40.0
50.0
70.0
50.0
55.0

75.0
60.0
90.0
75.0
105.0
110.0

50.0
40.0
60.0
70.0
55.0
55.0

120.0
100.0
120.0
120.0
140.0
160.0

13.30
120.00
135.00
41.10
82.80
78.00

152.00
60.00
151.30
118.00

14
15
16
16
16
16
16

FZA 14X40 M10


FH II 15 B
EA M16
FBN II 16
FAZ II 16
FHB-A DYN 16
RG M16

6.7
14.1
9.5
17.2
20.7
23.0
26.1

4.3
10.0
13.4
23.0
-

7.2
22.9
22.6
37.6
17.0
23.3

5.6
20.1
37.6
17.0
-

40.0
70.0
65.0
80.0
85.0
130.0
125.0

120.0
210.0
195.0
192.0
260.0
375.0
250.0

70.0
60.0
65.0
90.0
60.0
100.0
65.0

60.0
105.0
100.0
96.0
130.0
190.0
125.0

70.0
70.0
65.0
90.0
65.0
100.0
65.0

100.0
140.0
160.0
160.0
170.0
250.0
175.0

113.70
170.65
34.50
96.60
161.00
589.60
103.00

223.70
111.30
359.00
506.00

18
18

FH II 18 B
FZA 18X80 M12

18.9
18.9

12.2
12.3

33.7
19.3

24.5
19.3

80.0
80.0

240.0
240.0

70.0
80.0

120.0
120.0

80.0
70.0

160.0
160.0

252.00
292.00

304.40

DIAMETER-WISE RECOMMENDED
FISCHER ANCHOR PROPERTIES
NOTES
1)
2)
3)
4)
5)

Load values for concrete grade M25. For different concrete grades use influencing factors as in handbook.
Load values on Single Anchor - ie characteristic axial spacing & edge distance.
For anchor row, reduction factors for spacings & edge distances between Characteristic value & Minimum value are given in Handbook
Price of any one diameter depends on the length of the anchor - as required for different base plate thicknesses
Loads are for galvanized anchors.

Dia

Description

Recommended tension
load (KN)

Recommended Shear
Load (KN)

Effective
Anchorage
depth

Characteristic
axial spacing

Minimum
Axial
Spacing

Characteristic
Edge Distance

Minimum
Edge
Distance

Minimum
thickness
of member

List Price range as per


anchorlength for diff.
baseplate thickness
requirements
min.length
max.length

Un-cracked
zone
13.0
24.0
25.8
44.4

cracked
zone
16.2
-

Un-cracked
zone
40.0
38.2
36.4

cracked
zone
40.0
-

80.0
100.0
105.0
170.0

240.0
300.0
300.0
340.0

80.0
95.0
120.0
85.0

120.0
150.0
150.0
170.0

80.0
130.0
120.0
85.0

200.0
200.0
200.0
220.0

65.00
385.00
236.25
193.10

698.00
1178.00

20
20
20
20

EA M20
FAZ II 20
FBN II 20
RG M20

22
22

FZA 22X100 M16


FZA 22X125 M16

26.4
36.9

17.1
24.0

35.9
35.9

34.3
35.9

100.0
125.0

300.0
380.0

100.0
125.0

150.0
190.0

100.0
125.0

200.0
250.0

680.00
774.90

24
24
24

FAZ II 24
FH II 24/25 B
RG M24

33.5
34.0
65.8

24.0
17.1
-

49.1
48.0
52.4

49.1
34.3
-

125.0
100.0
210.0

380.0
300.0
420.0

120.0
80.0
105.0

190.0
150.0
210.0

150.0
100.0
105.0

250.0
200.0
260.0

810.00
501.00
474.00

821.40
1180.00

28
30
32

FH II 28 B
RG M30
FH II 32 B

36.9
85.2
48.5

24.0
31.5

73.8
83.3
97.0

47.9
63.0

125.0
280.0
150.0

375.0
560.0
450.0

375.0
140.0
450.0

190.0
280.0
225.0

375.0
140.0
450.0

250.0
330.0
300.0

966.00
739.80
1335.90

1428.00
1606.30

1245.00
1440.00

57.75
56.70
75.00
98.00
182.00
295.00
344.50

Chemicals
FIS - Vinylester - 360 ml - Shuttle Cartridge
FIS - Epoxy -390 ml - Shuttle Cartridge
RM - Resin Mortar Capsules
RM 8
RM 10
RM 12
RM 16
RM 20
RM 24
RM 32

To be used with RG M threaded rod or Rebar Steel (Construction steel)


To be used with RG M threaded rod or Rebar Steel (Construction steel)
To be used with RG M threaded rod