Soil Boring - geotechnical services

Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 1
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
CantiIever waII anaIysis
Input data
Project
Date : 11/2/2005
MateriaI of structure
Unit weight = 23.00 kN/m
3
Analysis of concrete structures carried out according to the standard EN 1992 1-1 (EC2).
Concrete : C 20/25
Cylinder compressive strength
Tensile strength
Elasticity modulus
f
ck
f
ct
E
cm
=
=
=
20.00
2.20
29000.00
MPa
MPa
MPa
Longitudinal steel : B500
Yield strength
Elasticity modulus
f
yk
E
=
=
500.00
200000.00
MPa
MPa
Geometry of structure
No.
Coordinate
X [m]
Depth
Z [m]
1
2
3
4
5
6
7
8
9
10
11
0.00
0.00
2.50
2.50
2.50
2.00
2.00
-1.60
-1.60
-0.60
-0.20
0.00
5.00
5.00
5.60
5.80
5.80
5.60
5.60
5.00
5.00
0.00
The origin [0,0] is located at the most upper right point of the wall.
Wall section area = 4.56 m
2
.

Name : Geometry Stage : 1
5.60
5.80
+.10
0.20
5.00
0.60
1.00 2.50
12.50:1
0.80
0.50
Basic soiI parameters
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 2
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
No. Name Pattern

ef
[]
c
ef
[kPa]

[kN/m
3
]

su
[kN/m
3
]

[]
1
2
3
Soil No. 1
Soil No. 2
Soil No. 3
29.00
31.50
27.00
10000.00
0.00
10.00
19.00
17.50
19.50
9.00
7.50
9.50
15.00
15.00
15.00
All soils are considered as cohesionless for at rest pressure analysis.

SoiI parameters
SoiI No. 1
Unit weight :
Stress-state :
Angle of internal friction :
Cohesion of soil :
Angle of friction struc.-soil :
Soil :
Saturated unit weight :

effective

ef
c
ef

cohesionless

sat
=
=
=
=
=
19.00
29.00
10000.00
15.00
19.00
kN/m
3

kPa

kN/m
3

SoiI No. 2
Unit weight :
Stress-state :
Angle of internal friction :
Cohesion of soil :
Angle of friction struc.-soil :
Soil :
Saturated unit weight :

effective

ef
c
ef

cohesionless

sat
=
=
=
=
=
17.50
31.50
0.00
15.00
17.50
kN/m
3

kPa

kN/m
3

SoiI No. 3
Unit weight :
Stress-state :
Angle of internal friction :
Cohesion of soil :
Angle of friction struc.-soil :
Soil :
Saturated unit weight :

effective

ef
c
ef

cohesionless

sat
=
=
=
=
=
19.50
27.00
10.00
15.00
19.50
kN/m
3

kPa

kN/m
3

GeoIogicaI profiIe and assigned soiIs
No.
Layer
[m]
Assigned soiI Pattern
1
2
3
2.30
1.70
-
Soil No. 1
Soil No. 2
Soil No. 3
Terrain profiIe
Terrain behind the structure is flat.

Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 3
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Name : Terrain Stage : 1
5.60
5.80
+.10
Water infIuence
Ground water table is located below the structure.

Resistance on front face of the structure
Resistance on front face of the structure: at rest
Soil on front face of the structure - Soil No. 1
Soil thickness in front of structure
Terrain in front of structure is flat.
h = 0.50 m
AppIied forces acting on the structure
No.
Force
new modification
Name Action
F
x
[kN/m]
F
z
[kN/m]
M
[kNm/m]
x
[m]
z
[m]
1 YES
Force
No. 1
permanent -30.00 0.00 0.00 -0.10 -0.20
GIobaI settings
Verification methodology : Analysis according to EN 1997
nput of patial factors : Standard
Design approach : 1 - reduction of actions and materials

PartiaI factors on actions (F) Fact.
Combination 1 [-]
UnfavourabIe FavourabIe
Combination 2 [-]
UnfavourabIe FavourabIe
Permanent actions
Variable actions
Water actions

w
1.35
1.50
1.30
1.00
0.00
1.00
1.30
1.00
1.00
0.00
PartiaI factors for soiI parameters (M) Fact.
Combination 1
[-]
Combination 2
[-]
Partial factor for intenal friction
Partial factor for effective cohesion
Partial factor for undrained shear strength
Partial factor for Poisson's ratio

mc

mcu

mv
1.00
1.00
1.00
1.00
1.25
1.25
1.40
1.00
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 4
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
PartiaI factors for variabIe actions Fact. [-]
Factor for combination value
Factor for frequent value
Factor for quasi-permanent value

2
0.70
0.50
0.30
Active earth pressure calculation - Coulomb
Passive earth pressure calculation - Caqout-Kerisel
Standard for concrete structures - EN 1992 1-1 (EC2)

Settings of the stage of construction
Combination : basic
The wall is free to move. Active earth pressure is therefore assumed.
The base key is considered as inclined footing bottom.

Verification No. 1
Pressure at rest on front face of the structure - partiaI resuIts
Layer
No.
Thickness
[m]

[]

d
[]
c
d
[kPa]

[kN/m
3
]
K
r
Comment
1 0.50 0.00 29.00 10000.00 19.00 0.515
Pressure at rest distribution on front face of the structure
Layer
No.
Start [m]
End [m]

Z
[kPa]

W
[kPa]
Pressure
[kPa]
Hor. comp.
[kPa]
Vert. comp.
[kPa]
1
0.00
0.50
0.00
9.50
0.00
0.00
0.00
4.89
0.00
4.89
0.00
0.00
Active pressure behind the structure - partiaI resuIts
Layer
No.
Thickness
[m]

[]

d
[]
c
d
[kPa]

[kN/m
3
]

d
[]
K
a
Comment
1
2
3
4
5
6
0.72
1.58
1.70
1.00
0.60
0.20
0.00
30.28
30.28
30.28
0.00
0.00
29.00
29.00
31.50
27.00
27.00
27.00
10000.00
10000.00
0.00
10.00
10.00
10.00
19.00
19.00
17.50
19.50
19.50
19.50
15.00
29.00
31.50
27.00
15.00
15.00
0.313
0.679
0.663
0.694
0.337
0.337
Active pressure distribution behind the structure (without surcharge)
Layer
No.
Start [m]
End [m]

Z
[kPa]

W
[kPa]
Pressure
[kPa]
Hor. comp.
[kPa]
Vert. comp.
[kPa]
1
2
3
4
5
6
0.00
0.72
0.72
2.30
2.30
4.00
4.00
5.00
5.00
5.60
5.60
5.80
0.00
13.65
13.65
43.70
43.70
73.45
73.45
92.95
92.95
104.65
104.65
108.55
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
28.97
48.69
42.07
55.61
20.68
24.63
24.63
25.95
0.00
0.00
0.00
0.00
13.70
23.02
22.74
30.06
19.98
23.79
23.79
25.06
0.00
0.00
0.00
0.00
25.53
42.91
35.40
46.79
5.35
6.37
6.37
6.72
Forces acting on construction - combination 1
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 5
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Coeff.
overtur.
Coeff.
sIiding
Coeff.
stress
Weight - wall
FF resistance
Weight - earth wedge
Active pressure
Force No. 1
0.00
-1.22
0.00
75.63
30.00
-1.34
-0.17
-2.00
-1.40
-5.80
104.88
0.00
99.17
104.09
0.00
1.80
0.00
2.44
3.41
1.50
1.000
1.000
1.000
1.000
1.350
1.000
1.000
1.000
1.350
1.350
1.350
1.000
1.350
1.350
1.350
Verification of compIete waII
Check for overturning stabiIity
Resisting moment
Overturning moment
M
res
M
ovr
=
=
785.35
340.68
kNm/m
kNm/m
WaII for overturning is SATISFACTORY
Check for sIip
Resisting horizontal force
Active horizontal force
H
res
H
act
=
=
209.16
124.42
kN/m
kN/m
WaII for sIip is SATISFACTORY
OveraII check - WALL is SATISFACTORY
Maximum stress in footing bottom :130.71kPa

Pressure at rest on front face of the structure - partiaI resuIts
Layer
No.
Thickness
[m]

[]

d
[]
c
d
[kPa]

[kN/m
3
]
K
r
Comment
1 0.50 0.00 23.91 8000.00 19.00 0.595
Pressure at rest distribution on front face of the structure
Layer
No.
Start [m]
End [m]

Z
[kPa]

W
[kPa]
Pressure
[kPa]
Hor. comp.
[kPa]
Vert. comp.
[kPa]
1
0.00
0.50
0.00
9.50
0.00
0.00
0.00
5.65
0.00
5.65
0.00
0.00
Active pressure behind the structure - partiaI resuIts
Layer
No.
Thickness
[m]

[]

d
[]
c
d
[kPa]

[kN/m
3
]

d
[]
K
a
Comment
1
2
3
4
5
6
0.72
1.58
1.70
1.00
0.60
0.20
0.00
30.28
30.28
30.28
0.00
0.00
23.91
23.91
26.12
22.18
22.18
22.18
8000.00
8000.00
0.00
8.00
8.00
8.00
19.00
19.00
17.50
19.50
19.50
19.50
12.37
23.91
26.12
22.18
12.32
12.32
0.382
0.722
0.702
0.739
0.407
0.407
Active pressure distribution behind the structure (without surcharge)
Layer
No.
Start [m]
End [m]

Z
[kPa]

W
[kPa]
Pressure
[kPa]
Hor. comp.
[kPa]
Vert. comp.
[kPa]
1
2
3
0.00
0.72
0.72
2.30
2.30
4.00
0.00
13.65
13.65
43.70
43.70
73.45
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
30.66
51.54
0.00
0.00
0.00
0.00
16.97
28.52
0.00
0.00
0.00
0.00
25.54
42.93
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 6
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Layer
No.
Start [m]
End [m]

Z
[kPa]

W
[kPa]
Pressure
[kPa]
Hor. comp.
[kPa]
Vert. comp.
[kPa]
4
5
6
4.00
5.00
5.00
5.60
5.60
5.80
73.45
92.95
92.95
104.65
104.65
108.55
0.00
0.00
0.00
0.00
0.00
0.00
46.75
61.17
28.41
33.18
33.18
34.77
28.49
37.27
27.76
32.41
32.41
33.97
37.07
48.50
6.06
7.08
7.08
7.42
Forces acting on construction - combination 2
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Coeff.
overtur.
Coeff.
sIiding
Coeff.
stress
Weight - wall
FF resistance
Weight - earth wedge
Active pressure
Force No. 1
0.00
-1.41
0.00
96.24
30.00
-1.34
-0.17
-2.00
-1.37
-5.80
104.88
0.00
99.17
106.38
0.00
1.80
0.00
2.44
3.42
1.50
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
Verification of compIete waII
Check for overturning stabiIity
Resisting moment
Overturning moment
M
res
M
ovr
=
=
794.21
305.77
kNm/m
kNm/m
WaII for overturning is SATISFACTORY
Check for sIip
Resisting horizontal force
Active horizontal force
H
res
H
act
=
=
153.58
109.55
kN/m
kN/m
WaII for sIip is SATISFACTORY
OveraII check - WALL is SATISFACTORY
Maximum stress in footing bottom :102.31kPa

Name : Verification Stage : 1; AnaIysis : 1
5.60
5.80
+.10
+x
+z
10+.88
+x
+z
1.22
+x
+z
99.17
+x
+z
128.66
+x
+z
30.00
Bearing capacity of foundation soiI
Forces acting at the centre of the footing bottom
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 7
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Number
Moment
[kNm/m]
Norm. force
[kN/m]
Shear Force
[kN/m]
Eccentricity
[m]
Stress
[kPa]
1 170.31 422.37 120.63 0.44 130.71
Bearing capacity of foundation soiI check
Eccentricity verification
Max. eccentricity of normal force
Maximum allowable eccentricity
e
e
alw
=
=
436.7
1354.6
mm
mm
Eccentricity of the normaI force is SATISFACTORY
Footing bottom bearing capacity verification
Max. stress at footing bottom
Bearing capacity of foundation soil

R
d
=
=
130.71
180.00
kPa
kPa
Bearing capacity of foundation soiI is SATISFACTORY
OveraII verification - bearing capacity of found. soiI is SATISFACTORY

Name : Bearing cap. Stage : 1
5.60
5.80
+.10
1
3
0
.
7
1
1
3
0
.
7
1
Dimensioning No. 1
Forces acting on construction - combination 1
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Coeff.
moment
Coeff.
norm.force
Coeff.
shear for.
Weight - wall
Pressure at rest
Force No. 1
0.00
118.80
30.00
-2.08
-1.65
-5.20
45.98
0.00
0.00
0.38
0.60
0.50
1.000
1.350
1.350
1.350
1.000
1.000
1.000
1.350
1.350
Forces acting on construction - combination 2
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Coeff.
moment
Coeff.
norm.force
Coeff.
shear for.
Weight - wall
Pressure at rest
Force No. 1
0.00
137.35
30.00
-2.08
-1.66
-5.20
45.98
0.00
0.00
0.38
0.60
0.50
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
1.000
WaII stem check
Reinforcement and dimensions of the cross-section
Bar diameter
Number of bars
Reinforcement cover
Cross-section width
=
=
=
=
20.0
14
30.0
1.00
mm
mm
m
Soil Boring - geotechnical services
Tiverton rd. 24
London, United Kingdom
tel:5478354125, fax:5478354126
www.soilboring.com, info@soilboring.com
Project: Shopping center - Black Rose
Soil Boring - geotechnical services, London 8
[GEO5 - Cantilever Wall | version 5.10.36.0 | hardware key 4001 / 1 | Fine s.r.o. | Copyright 2010 Fine spol. s r.o. All Rights Reserved | www.finesoftware.eu]
Cross-section depth = 0.60 m
Reinforcement ratio
Ultimate moment

M
Rd
=
=
0.79
933.56
%
kNm
>
>
0.13
471.29
%
kNm
=
=

min
M
Ed
Cross-section is SATISFACTORY.

Name : Dimensioning Stage : 1; Dimensioning : 1
5.60
5.80
+.10
+x
+z
+5.98
+x
+z
137.35
+x
+z
30.00
Dimensioning No. 2
Forces acting on construction - combination 1
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Design
coefficient
Weight - wall
FF resistance
Weight - earth wedge
Active pressure
Force No. 1
0.00
-1.22
0.00
75.63
30.00
-1.34
-0.17
-2.00
-1.40
-5.80
104.88
0.00
99.17
104.09
0.00
1.80
0.00
2.44
3.41
1.50
1.350
1.000
1.350
1.350
1.350
Forces acting on construction - combination 2
Name F
hor
[kN/m]
App.Pt.
Z [m]
F
vert
[kN/m]
App.Pt.
X [m]
Design
coefficient
Weight - wall
FF resistance
Weight - earth wedge
Active pressure
Force No. 1
0.00
-1.41
0.00
96.24
30.00
-1.34
-0.17
-2.00
-1.37
-5.80
104.88
0.00
99.17
106.38
0.00
1.80
0.00
2.44
3.42
1.50
1.000
1.000
1.000
1.000
1.000
Front waII jump check
Reinforcement and dimensions of the cross-section
Bar diameter
Number of bars
Reinforcement cover
Cross-section width
Cross-section depth
=
=
=
=
=
16.0
6
30.0
1.00
0.60
mm
mm
m
m
Reinforcement ratio
Ultimate moment

M
Rd
=
=
0.21
284.46
%
kNm
>
>
0.13
93.38
%
kNm
=
=

min
M
Ed
Cross-section is SATISFACTORY.