Introduction to scripts Applying scripts VSWR using Anritsu Site Master CTU1 TX Calibration CTU2 TX Calibration Cable configuration
BTS CALIBRATION
Command Scripts :
Scripts for TX and RX calibration are required to be added to Procom Plus to make the activity easier and less time consuming. These are list of commands for specific activities, which run automatically on a single click, and the desired output is achieved Scripts Location:
Add the script files to the following location C:\ Program Files\ Procom Plus\Aspect All scripts are automatically picked up from Aspect file by Procom plus software
Meta Keys:
Meta Keys are user defined buttons to directly execute a script or a command
A.BOURI
Page 2
BTS CALIBRATION
A.BOURI
Page 3
BTS CALIBRATION
VSWR TEST
A.BOURI
Page 4
BTS CALIBRATION
Steps to perform :
Turn on Site Master by pressing ON/OFF Press Enter to Continue Press RECALL SETUP and select GSM900 or DCS 1800 accordingly Move to Level 3 and lock all DRIs of the sector in which sweep test (VSWR) is required Remove feeder cable from the respective DRIs DUP and connect it with RF OUT port of site master Wait for 10 seconds and graphical display will appear showing the reflection throughout cable length. Press MARKER, select M1 and then press EDIT, now u can move the marker through the cable length and check reflections at any desired distance To save a current reflection, press SAVE DISPLAY, save by site name and fault location for easy access in future To view a previous display, press RECALL DISPLAY
Setting to GSM900 :
Press MODE Select FREQ-SWR and press ENTER Press F1 and enter lower limit Example F1 = 830.00 MHZ Press F2 and enter upper limit Example F2= 1000.00 MHZ (Now frequencies are set) Press MODE again Select DTF-SWR (DTF stands for distance to fault) press ENTER Press D1 to enter start distance D1= 0.0 m Press D2 to enter end distance (estimate the length of the cable, it should not be less) Example D2= 140 m (Now distance is set) To set up the amplitude, Press AMPLITUDE Select TOP and enter limit 1.5 Now select BOTTOM and enter 1 (amplitude cannot be lesser than 1) Finally, to save the settings, press SAVE SETUP Check your saved settings for GSM 900 by RECALL SETUP
Page 5
A.BOURI
BTS CALIBRATION
Remarque 1: we will use our sitemaster (equipped with option 5) + Anritsu RF Wattmeter Power Monitor.
A.BOURI
Page 6
BTS CALIBRATION
Move to level 3 by using chg_l " command Login to BSC as follows Press Ctrl + n Write the command Rlogin 1 0114h (0114h to 0119h) Again press Ctrl + n , now you are in BSC, it can be verified by disp_site, BSC ID is 0 Change to level 3 Write the command Store <site id> to enable calibration data Now write disp_cal_data <id> dri x y to check for Store Calibration Data: enabled
Lock the sector by the command Lock <Site Id> dri x y, Repeat the same for all DRIs of the particular sector. While locking a radio, it must be noted to lock the DRI with RTF 0 at the last. RTF 0 of each sector contains BCCH
A.BOURI
Page 7
BTS CALIBRATION
RFI0 SECT A
BTS CALIBRATION
A.BOURI
Page 9
BTS CALIBRATION
Calibration of one radio (CTU1) is complete. Repeat the same process for all radios to be calibrated. After completing the last DRI, remove power meter from that DRI and connect back RF cable (All radios that are calibrated are still locked) Now login to BSC and Change level by chg_l Clear calibration data of all DRIs that are calibrated by the command Clear_cal_data <site Id> dri x y Give hard reset to the radios (Must in CTU1) In service all radios by command: o Ins <Site ID> dri x y TX Calibration is complete, Note that offsets increasing 6 indicates that the particular CTU1 is faulty and may alter power again shortly. Check through disp_cal_data <id> dri x y command that offsets have changed, if offset value is changed, then TX calibration of that DRI is successful.
A.BOURI
Page 10
BTS CALIBRATION
Login to site through MCUF Check site id by disp_site command State Radios by State <id> dri * * Check alarms at site disp_act <id> Check equipage and antenna select of radios by disp_eq <id> dri x y
Move to level 3 by using chg_l " command Login to BSC as follows Press Ctrl + n Write the command Rlogin 1 0114h (0114h to 0119h) Again press Ctrl + n , now you are in BSC, it can be verified by disp_site, BSC ID is 0 Change to level 3 and Write the command Store <site id> to enable calibration data Now write disp_cal_data <id> dri x y to check for Store Calibration Data: enabled
A.BOURI
Page 11
BTS CALIBRATION
Lock the sector by the command Lock <Site Id> dri x y, repeat the same for all DRIs of the particular sector. While locking a radio, it must be noted to lock The DRI with RTF 0 at the last. RTF 0 of each sector contains BCCH
Remove RF cable from dup and connect Power meter sensor in between. Position of sensor should be such that the arrow should direct towards the antenna. Connect the jumper cable with power meter and turn it on If power meter is showing values in dbm, convert them to Watt from the front display Now that the power meter is connected to the DUP, in service one radio and keep its associated radio locked, normally , in a CTU2 with two radios, the 1st one is in-serviced and the 2nd one is left locked (0 0 in-serviced and 0 1 locked)
A.BOURI
Page 12
BTS CALIBRATION
Login to DRI using EQCP cable (no need to reset clock to 0 in case of CTU2). Run script TX_double or TX_single accordingly, depending weather theCTU2 is double density or single density Adjust the power by giving offsets through U and D keys. For GSM 900, power should be 20 Watts (>=20 W & <21 W). For DCS 1800, power should be 16 Watts (>=16 W & <17 W). To increase power use key U and to decrease power use the Key D Press Q to quit after power finally adjusted as above
CTU2 TX Scripts:
To run TX_Double/TX_Single script for CTU2
Press Alt+F3 to open Aspect file window Select TX Select CTU2 Highlight TX_Double or TX_single, depending upon radios single or double density click compile and run
Store the calibration by command cal_store 1, it will show PASS after executing this command Login back to H2SC and get the calibrated DRI locked Remove Power meter and connect back the RF cable Login to BSC
Page 13
A.BOURI
BTS CALIBRATION
Clear previous calibration data by command clear_cal_data <Site ID> dri x y Check that the calibration data is cleared by disp_cal_data <Site ID> dri x y It should show no calibration data Now finally, in-service the radios o ins <ID> dri x y
Verifying successful
If the offset value is changed after Power calibration (using this command), calibration successful If the frequencies (in hexa decimals) have changed after RX calibration calibration successful
A.BOURI
Page 14
BTS CALIBRATION
Cble Configurations :
A.BOURI
Page 15