Você está na página 1de 4

19

KITCHEN HOODS
Description
- Deslgned for ltratlon of hot alr and oll fumes, separated
ln case of thermal treatment of nutrltlve products.
- very sultable for kltchens ln restaurants.
Models
- Ck-A - wall type wlth posslblllty for exhaustlon of pol-
luted alr and supply of fresh alr.
- Ck-8 - wall type wlth posslblllty for extractlon of polluted
alr.
- - - lsland type - standard verslon ls wlth posslbll-
lty for exhaustlon of polluted alr and supply of fresh alr.
Upon customer's request can be produced modlcatlon
only for extractlon of polluted alr.
- Ck-S" (Show cooklng) - lsland or wall type wlth lmproved
deslgn. Standard verslon ls for extractlon of polluted alr
and for some models there ls posslblllty for supply of
fresh alr and lncorporatlon of llghts. Pllter cassettes for
thls serles are wlth dlnerent dlmenslons.
KITCHEN HOODS 02.04-01 CK
Construction
- Produced ln two verslons:
- Models CK-A, CK-8 and CK-O made of galvanlzed met-
al sheets wlth electrostatlc palntlng ln whlte color (PAL
90l0),
- Serles CK-S` - stalnless metal sheet |NOX 304 (mat or
pollshed).
- Completed wlth metal lters - look at sectlon 02.03:
- APC-MM - wlre mesh lter cassettes,
- APC-ML - labyrlnth lter cassettes,
- APC-MC - comblned lter cassettes.
- As standard equlpment for kltchen hoods are produced
regulatlon dampers wlth manual control.
Installation
- 1olned to the alr duct system by a nange type connectlon.
- wall lnstallatlon wlth anchor bolts (wall plugs) or hanglng
to celllng wlth studs, rope or chaln.
20
02.04-02 KITCHEN HOODS CK
CK-A, CK-B and - wall and island type kitchen hoods
Overall and joined dimensions
Type
Overall dimensions [mm] Joined dimensions [mm]
IiIters
number
Length, L Depth Height Extraction Supply
-
l000 700 450+250 250/400 l50/400 2
l500 700 450+250 250/400 l50/400 3
CK-8
l000 700 450+250 250/400 - 2
l500 700 450+250 250/400 - 3
- l000 l400 450+250 400/400 2xl50/400 4
Pressure drop P [] at length L=1000 mm
Air ow [m
3
/h]
IiIter type
Ck-A or Ck-8 Ck-O
600 800 1000 1200 1600 2000 2400
AIC-MM wire net Iter l7 24 3l 43 25 32 45
AIC-ML Iabyrinth type Iter 24 33 46 55 34 48 58
AIC-MC combined cassette 3l 40 58 72 4l 59 75
Note:
- Nomlnal alr volume and LP for kltchen hoods are shown ln shadowed columns.
- Upon customer's request could be produced kltchen hoods wlth dlnerent dlmenslons, electrostatlc palntlng wlth dlnerent
PAL color or from stalnless metal sheets |NOX 304.
21
KITCHEN HOODS 02.04-03 CK
CK-S1, CK-S2 island type, type Show cooking
Overall and joined dimensions
Type
Overall dimensions [mm]
Joining opening,
extraction [mm]
IiIters
number
Length, L Depth Height
Ck-S1
l000 l200 450+250 400/400 4
l500 l200 450+250 400/400 6
2000 l200 450+250 2x400/400 8
Ck-S2
l000 lll0 480+80 250 4
2000 lll0 480+80 2x250 8
Pressure drop P [] at length L=1000 mm
Air ow [m
3
/h]
Type of kitchen hood
Ck-S1 Ck-S2
1200 1600 2000 1200 1600 2000
AIC-MM wire mesh Iter 2l 29 37 20 27 35
AIC-ML Iabyrinth Iter 3l 42 56 29 39 57
AIC-MC combined cassette 38 48 69 36 45 65
Note:
- Nomlnal alr volume and LP for kltchen hoods are shown ln the shadowed column.
- Upon customer's request can be produced kltchen hoods wlth dlnerent dlmenslons.
- Type - lsland type wlth posslblllty for extractlon
- Materlal - |NOX 304
- Completed wlth three types lter cassettes wlth dlmen-
slons 500x375x30 mm
- Posslblllty for lncorporatlon of llghts - 220v
- Type - lsland type wlth posslblllty for extractlon
- Materlal - |NOX 304
- Completed wlth three types lter cassettes wlth dlmen-
slons 500x445x30 mm
22
02.04-04 KITCHEN HOODS CK
CK-S3 kitchen hood for wall installation, type Show cooking
Overall and joined dimensions
Pressure drop P [] at length L=1000 mm
Air ow [m
3
/h]
IiIter type
600 800 1000 1200
AIC-MM wire mesh Iter l9 25 36 50
AIC-ML Iabyrinth Iter 26 36 49 63
AIC-MC combined cassette 4l 48 6l 79
Note:
- Nomlnal alr volume and LP for kltchen hoods are shown ln the shadowed column.
- Upon customer request could be produced kltchen hoods wlth dlnerent dlmenslons.
- wall type wlth posslblllty for extractlon of polluted alr
and supply of fresh alr ln two places ln worklng zone.
- Materlal - |NOX 304
- Completed wlth three types lter cassettes wlth dlmen-
slons 500x375x30 mm
- Posslblllty for lncorporatlon of llghts - 220v
Type
Overall dimensions [mm] Joined openings [mm]
IiIter
number
Length, L Depth Height Extraction Supply
-S3
l000 950 425+l60 200/500 200/500 2
l500 950 425+l60 200/500 200/500 3
Order designation
CK - + 8 MM l000
Pllter cassettes type
MM - wlre mesh cassette
ML - labyrlnth cassette
MC - comblned cassette
Kltchen hood length: l000, l500, 2000
Model: A, 8, O, Sl, S2 or S3
Kltchen hood model